Normalized to: Cerdeño, D.
[1]
oai:arXiv.org:2005.14067 [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a
surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration;
Amaral, D. W.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Banik, S.;
Barker, D.;
Bathurst, C.;
Bauer, D. A.;
Bezerra, L. V. S.;
Bhattacharyya, R.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Chen, R.;
Chott, N.;
Cooley, J.;
Coombes, H.;
Corbett, J.;
Cushman, P.;
De Brienne, F.;
di Vacri, M. L.;
Diamond, M. D.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fouts, K.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hines, B. A.;
Hollister, M. I.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Li, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
MacFarlane, D. B.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mayer, A. J.;
Michaud, É. M.;
Michielin, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nagorny, S.;
Nelson, J.;
Neog, H.;
Novati, V.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Pakarha, P.;
Partridge, R.;
Podviianiuk, R.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Rau, W.;
Reid, E.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sattari, A.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Sincavage, D. J.;
Stanford, C.;
Stein, M.;
Street, J.;
Toback, D.;
Underwood, R.;
Verma, S.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wills, L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Yu, T. C.;
Zhang, E.;
Zhang, H. G.;
Zhao, X.;
Zheng, L.
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark
matter inelastically scattering off of electrons, and on dark photon and
axion-like particle absorption, using a second-generation SuperCDMS
high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV
phonon energy resolution; for a detector bias of 100 V, this corresponds to a
charge resolution of 3% of a single electron-hole pair. The energy spectrum is
reported from a blind analysis with 1.2 gram-days of exposure acquired in an
above-ground laboratory. With charge carrier trapping and impact ionization
effects incorporated into the dark matter signal models, the dark
matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter
masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50
eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the
axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90%
confidence-level upper limits within the above mentioned mass ranges are
$\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$,
$\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]
oai:arXiv.org:1806.07043 [pdf] - 1944785
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in
Germanium with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwal, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Banik, S.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-06-19, last modified: 2019-08-16
Future direct searches for low-mass dark matter particles with germanium
detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds
from radioactive isotopes activated by cosmogenic radiation inside the
germanium. There are limited experimental data available to constrain
production rates and a large spread of theoretical predictions. We examine the
calculation of expected production rates, and analyze data from the second run
of the CDMS low ionization threshold experiment (CDMSlite) to estimate the
rates for several isotopes. We model the measured CDMSlite spectrum and fit for
contributions from tritium and other isotopes. Using the knowledge of the
detector history, these results are converted to cosmogenic production rates at
sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H,
1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
[3]
oai:arXiv.org:1808.09098 [pdf] - 1873743
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood
Fit
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
De Brienne, F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Neog, H.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-08-27, last modified: 2019-04-25
The Cryogenic Dark Matter Search low ionization threshold experiment
(CDMSlite) searches for interactions between dark matter particles and
germanium nuclei in cryogenic detectors. The experiment has achieved a low
energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark
matter particles. We present an analysis of the final CDMSlite data set, taken
with a different detector than was used for the two previous CDMSlite data
sets. This analysis includes a data "salting" method to protect against bias,
improved noise discrimination, background modeling, and the use of profile
likelihood methods to search for a dark matter signal in the presence of
backgrounds. We achieve an energy threshold of 70 eV and significantly improve
the sensitivity for dark matter particles with masses between 2.5 and 10
GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark
matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$
cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous
CDMSlite result.
[4]
oai:arXiv.org:1701.08134 [pdf] - 1581301
Reopening the Higgs portal for Singlet Scalar Dark Matter
Submitted: 2017-01-27, last modified: 2017-02-22
A real singlet scalar, connected to the Standard Model sector through a
portal with the Higgs boson, is one of the simplest and most popular models for
dark matter (DM). However, the experimental advances in direct and indirect DM
searches, together with the latest results from the LHC, have ruled out vast
areas of the parameter space of this scenario, and are expected to probe it
completely within the next years, ruling it out if no signal is found.
Motivated by the simplicity of this model, in this article we address a
minimal, renormalizable extension that could evade detection, consisting of the
addition of an extra real singlet scalar field in the dark sector. We analyze
the physical constraints on the model and show that the new annihilation and/or
coannihilation channels involving the extra singlet allow to reproduce the
correct DM relic abundance while avoiding the bounds from direct and indirect
searches for any DM mass above 50 GeV. We also show that, in some interesting
regions of the parameter space, the extra particle can be integrated-out,
leaving a "clever" effective theory (just involving the DM particle and the
Higgs), that essentially reproduces the results.
[5]
oai:arXiv.org:1610.00006 [pdf] - 1561019
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Arnquist, I.;
Baker, W.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hong, Z.;
Hoppe, E.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2016-09-30
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly
detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter
by using cryogenic detectors of two types (HV and iZIP) and two target
materials (germanium and silicon). The experiment is being designed with an
initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$
for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue
exploration to both smaller masses and better sensitivities. The phonon
sensitivity of the HV detectors will be sufficient to detect nuclear recoils
from sub-GeV dark matter. A detailed calibration of the detector response to
low energy recoils will be needed to optimize running conditions of the HV
detectors and to interpret their data for dark matter searches. Low-activity
shielding, and the depth of SNOLAB, will reduce most backgrounds, but
cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be
present in the detectors at some level. Even if these backgrounds are x10
higher than expected, the science reach of the HV detectors would be over three
orders of magnitude beyond current results for a dark matter mass of 1
GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in
detector response and backgrounds, and will provide better sensitivity for dark
matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and
iZIP), and targets (germanium and silicon), planned for the experiment, as well
as flexibility in how the detectors are operated, will allow us to maximize the
low-mass reach, and understand the backgrounds that the experiment will
encounter. Upgrades to the experiment, perhaps with a variety of
ultra-low-background cryogenic detectors, will extend dark matter sensitivity
down to the "neutrino floor", where coherent scatters of solar neutrinos become
a limiting background.
[6]
oai:arXiv.org:1504.05871 [pdf] - 1293576
Improved WIMP-search reach of the CDMS II germanium data
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yang, X.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-04-22, last modified: 2015-10-13
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were
reprocessed with an improved charge-pulse fitting algorithm. Two new analysis
techniques to reject surface-event backgrounds were applied to the 612 kg days
germanium-detector WIMP-search exposure. An extended analysis was also
completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to
increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there
were zero candidate events above a deposited energy of 10 keV and 6 events in
the lower-threshold analysis. This yielded minimum WIMP-nucleon
spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and
$1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$
WIMPs, respectively. This improves the previous CDMS II result by a factor of
2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.