sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Cavalieri, David A.

Normalized to: Cavalieri, D.

2 article(s) in total. 33 co-authors, from 1 to 2 common article(s). Median position in authors list is 8,5.

[1]  oai:arXiv.org:1609.04411  [pdf] - 1481118
The iLocater cryostat: design and thermal control strategy for precision radial velocity measurements
Comments: 10 pages, 7 figures
Submitted: 2016-09-14
The current generation of precision radial velocity (RV) spectrographs are seeing-limited instruments. In order to achieve high spectral resolution on 8m class telescopes, these spectrographs require large optics and in turn, large instrument volumes. Achieving milli-Kelvin thermal stability for these systems is challenging but is vital in order to obtain a single measurement RV precision of better than 1m/s. This precision is crucial to study Earth-like exoplanets within the habitable zone. iLocater is a next generation RV instrument being developed for the Large Binocular Telescope. Unlike seeing-limited RV instruments, iLocater uses adaptive optics (AO) to inject a diffraction-limited beam into single-mode fibers. These fibers illuminate the instrument spectrograph, facilitating a diffraction-limited design and a small instrument volume compared to present-day instruments. This enables intrinsic instrument stability and facilitates precision thermal control. We present the current design of the iLocater cryostat which houses the instrument spectrograph and the strategy for its thermal control. The spectrograph is situated within a pair of radiation shields mounted inside an MLI lined vacuum chamber. The outer radiation shield is actively controlled to maintain instrument stability at the sub-mK level and minimize effects of thermal changes from the external environment. An inner shield passively dampens any residual temperature fluctuations and is radiatively coupled to the optical board. To provide intrinsic stability, the optical board and optic mounts will be made from Invar and cooled to 58K to benefit from a zero coefficient of thermal expansion (CTE) value at this temperature. Combined, the small footprint of the instrument spectrograph, the use of Invar, and precision thermal control will allow long-term sub-milliKelvin stability to facilitate precision RV measurements.
[2]  oai:arXiv.org:1609.04412  [pdf] - 1481119
iLocater: A Diffraction-limited Doppler Spectrometer for the Large Binocular Telescope
Comments: 13 pages, 11 figures
Submitted: 2016-09-14
We are developing a stable and precise spectrograph for the Large Binocular Telescope (LBT) named "iLocater." The instrument comprises three principal components: a cross-dispersed echelle spectrograph that operates in the YJ-bands (0.97-1.30 microns), a fiber-injection acquisition camera system, and a wavelength calibration unit. iLocater will deliver high spectral resolution (R~150,000-240,000) measurements that permit novel studies of stellar and substellar objects in the solar neighborhood including extrasolar planets. Unlike previous planet-finding instruments, which are seeing-limited, iLocater operates at the diffraction limit and uses single mode fibers to eliminate the effects of modal noise entirely. By receiving starlight from two 8.4m diameter telescopes that each use "extreme" adaptive optics (AO), iLocater shows promise to overcome the limitations that prevent existing instruments from generating sub-meter-per-second radial velocity (RV) precision. Although optimized for the characterization of low-mass planets using the Doppler technique, iLocater will also advance areas of research that involve crowded fields, line-blanketing, and weak absorption lines.