Normalized to: Cavaliere, F.
[1]
oai:arXiv.org:2006.14889 [pdf] - 2122751
A chemically etched corrugated feedhorn array for D-band CMB
observations
Mandelli, Stefano;
Manzan, Elenia;
Mennella, Aniello;
Cavaliere, Francesco;
Viganò, Daniele;
Franceschet, Cristian;
de Bernardis, Paolo;
Bersanelli, Marco;
Castellano, Maria Gabriella;
Coppolecchia, Alessandro;
Cruciani, Angelo;
Gervasi, Massimo;
Lamagna, Luca;
Limonta, Andrea;
Masi, Silvia;
Paiella, Alessandro;
Passerini, Andrea;
Pettinari, Giorgio;
Piacentini, Francesco;
Tommasi, Elisabetta;
Volpe, Angela;
Zannoni, Mario
Submitted: 2020-06-26
We present the design, manufacturing, and testing of a 37-element array of
corrugated feedhorns for Cosmic Microwave Background (CMB) measurements between
$140$ and $170$ GHz. The array was designed to be coupled to Kinetic Inductance
Detector arrays, either directly (for total power measurements) or through an
orthomode transducer (for polarization measurements). We manufactured the array
in platelets by chemically etching aluminum plates of $0.3$ mm and $0.4$ mm
thickness. The process is fast, low-cost, scalable, and yields high-performance
antennas compared to other techniques in the same frequency range. Room
temperature electromagnetic measurements show excellent repeatability with an
average cross polarization level about $-20$ dB, return loss about $-25$ dB,
first sidelobes below $-25$ dB and far sidelobes below $-35$ dB. Our results
qualify this process as a valid candidate for state-of-the-art CMB experiments,
where large detector arrays with high sensitivity and polarization purity are
of paramount importance in the quest for the discovery of CMB polarization
$B$-modes.
[2]
oai:arXiv.org:2005.01187 [pdf] - 2089273
Progress report on the Large Scale Polarization Explorer
Lamagna, L.;
Addamo, G.;
Ade, P. A. R.;
Baccigalupi, C.;
Baldini, A. M.;
Battaglia, P. M.;
Battistelli, E.;
Baù, A.;
Bersanelli, M.;
Biasotti, M.;
Boragno, C.;
Boscaleri, A.;
Caccianiga, B.;
Caprioli, S.;
Cavaliere, F.;
Cei, F.;
Cleary, K. A.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
Corsini, D.;
Cuttaia, F.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Petris, M.;
Del Torto, F.;
Fafone, V.;
Farooqui, Z.;
Farsian, F.;
Fontanelli, F.;
Franceschet, C.;
Gaier, T. C.;
Gatti, F.;
Genova-Santos, R.;
Gervasi, M.;
Ghigna, T.;
Grassi, M.;
Grosso, D.;
Gualtieri, R.;
Incardona, F.;
Jones, M.;
Kangaslahti, P.;
Krachmalnicoff, N.;
Mainini, R.;
Maino, D.;
Mandelli, S.;
Maris, M.;
Masi, S.;
Matarrese, S.;
May, A.;
Mena, P.;
Mennella, A.;
Molina, R.;
Molinari, D.;
Morgante, G.;
Nati, F.;
Natoli, P.;
Pagano, L.;
Paiella, A.;
Paonessa, F.;
Passerini, A.;
Perez-de-Taoro, M.;
Peverini, O. A.;
Pezzotta, F.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Polastri, L.;
Polenta, G.;
Poletti, D.;
Presta, G.;
Realini, S.;
Reyes, N.;
Rocchi, A.;
Rubiño-Martin, J. A.;
Sandri, M.;
Sartor, S.;
Schillaci, A.;
Signorelli, G.;
Siri, B.;
Soria, M.;
Spinella, F.;
Tapia, V.;
Tartari, A.;
Taylor, A.;
Terenzi, L.;
Tomasi, M.;
Tommasi, E.;
Tucker, C.;
Vaccaro, D.;
Vigano, D. M.;
Villa, F.;
Virone, G.;
Vittorio, N.;
Volpe, A.;
Watkins, B.;
Zacchei, A.;
Zannoni, M.
Submitted: 2020-05-03, last modified: 2020-05-05
The Large Scale Polarization Explorer (LSPE) is a cosmology program for the
measurement of large scale curl-like features (B-modes) in the polarization of
the Cosmic Microwave Background. Its goal is to constrain the background of
inflationary gravity waves traveling through the universe at the time of
matter-radiation decoupling. The two instruments of LSPE are meant to
synergically operate by covering a large portion of the northern microwave sky.
LSPE/STRIP is a coherent array of receivers planned to be operated from the
Teide Observatory in Tenerife, for the control and characterization of the
low-frequency polarized signals of galactic origin; LSPE/SWIPE is a
balloon-borne bolometric polarimeter based on 330 large throughput multi-moded
detectors, designed to measure the CMB polarization at 150 GHz and to monitor
the polarized emission by galactic dust above 200 GHz. The combined performance
and the expected level of systematics mitigation will allow LSPE to constrain
primordial B-modes down to a tensor/scalar ratio of $10^{-2}$. We here report
the status of the STRIP pre-commissioning phase and the progress in the
characterization of the key subsystems of the SWIPE payload (namely the
cryogenic polarization modulation unit and the multi-moded TES pixels) prior to
receiver integration.
[3]
oai:arXiv.org:1912.10841 [pdf] - 2052103
Wideband 67-116 GHz receiver development for ALMA Band 2
Yagoubov, P.;
Mroczkowski, T.;
Belitsky, V.;
Cuadrado-Calle, D.;
Cuttaia, F.;
Fuller, G. A.;
Gallego, J. -D.;
Gonzalez, A.;
Kaneko, K.;
Mena, P.;
Molina, R.;
Nesti, R.;
Tapia, V.;
Villa, F.;
Beltran, M.;
Cavaliere, F.;
Ceru, J.;
Chesmore, G. E.;
Coughlin, K.;
De Breuck, C.;
Fredrixon, M.;
George, D.;
Gibson, H.;
Golec, J.;
Josaitis, A.;
Kemper, F.;
Kotiranta, M.;
Lapkin, I.;
Lopez-Fernandez, I.;
Marconi, G.;
Mariotti, S.;
McGenn, W.;
McMahon, J.;
Murk, A.;
Pezzotta, F.;
Phillips, N.;
Reyes, N.;
Ricciardi, S.;
Sandri, M.;
Strandberg, M.;
Terenzi, L.;
Testi, L.;
Thomas, B.;
Uzawa, Y.;
Vigano, D.;
Wadefalk, N.
Submitted: 2019-12-20, last modified: 2020-02-20
ALMA has been operating since 2011, but has not yet been populated with the
full suite of intended frequency bands. In particular, ALMA Band 2 (67-90 GHz)
is the final band in the original ALMA band definition to be approved for
production. We aim to produce a wideband, tuneable, sideband-separating
receiver with 28 GHz of instantaneous bandwidth per polarisation operating in
the sky frequency range 67-116 GHz. Our design anticipates new ALMA
requirements following the recommendations in the 2030 ALMA Development
Roadmap. The cryogenic cartridge is designed to be compatible with the ALMA
Band 2 cartridge slot, where the coldest components -- the feedhorns, orthomode
transducers, and cryogenic low noise amplifiers -- operate at a temperature of
15 K. We use multiple simulation methods and tools to optimise our designs for
both the passive optics and the active components. The cryogenic cartridge
interfaces with a room temperature cartridge hosting the local oscillator (LO)
and the downconverter module. This warm cartridge is largely based on GaAs
semiconductor technology and is optimised to match the cryogenic receiver
bandwidth with the required instantaneous LO tuning range. Our collaboration
has designed, fabricated, and tested multiple technical solutions for each of
the components, producing a state-of-the-art receiver covering the full ALMA
Band 2 & 3 atmospheric window. The receiver is suitable for deployment on ALMA
in the coming years, and is capable of dual-polarisation, sideband-separating
observations in intermediate frequency bands spanning 4-18 GHz, for a total of
28 GHz on-sky bandwidth per polarisation channel. We conclude that the 67-116
GHz wideband implementation for ALMA Band 2 is now feasible, and this receiver
is a compelling instrumental upgrade that will enhance observational
capabilities and scientific reach.
[4]
oai:arXiv.org:2001.10272 [pdf] - 2065386
QUBIC: the Q & U Bolometric Interferometer for Cosmology
Battistelli, E. S.;
Ade, P.;
Alberro, J. G.;
Almela, A.;
Amico, G.;
Arnaldi, L. H.;
Auguste, D.;
Aumont, J.;
Azzoni, S.;
Banfi, S.;
Battaglia, P.;
Baù, A.;
Bèlier, B.;
Bennett, D.;
Bergè, L.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bleurvacq, N.;
Bonaparte, J.;
Bonis, J.;
Bottani, A.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Charlassier, R.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Dheilly, S.;
Di Donato, A.;
Dumoulin, L.;
Etchegoyen, A.;
Fasciszewski, A.;
Ferreyro, L. P.;
Fracchia, D.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Ganga, K.;
Garcìa, B.;
Redondo, M. E. Garcìa;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Gilles, V.;
Giraud-Heraud, Y.;
Berisso, M. Gòmez;
Gonzàlez, M.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. -Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillè, S.;
Hoang, D. T.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Luterstein, R.;
Maffei, B.;
Marnieros, S.;
Marty, W.;
Masi, S.;
Mattei, A.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Mennella, A.;
Montier, L.;
Mousset, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
Nati, F.;
Olivieri, E.;
Oriol, C.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perbost, C.;
Perciballi, M.;
Pezzotta, F.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Platino, M.;
Polenta, G.;
Prèle, D.;
Puddu, R.;
Rambaud, D.;
Ringegni, P.;
Romero, G. E.;
Salatino, M.;
Salum, J. M.;
Schillaci, A.;
Scòccola, C.;
Scully, S.;
Spinelli, S.;
Stankowiak, G.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Thermeau, J. -P.;
Timbie, P.;
Tomasi, M.;
Torchinsky, S.;
Tristram, M.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Viganò, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2020-01-28
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative
experiment designed to measure the polarization of the Cosmic Microwave
Background and in particular the signature left therein by the inflationary
expansion of the Universe. The expected signal is extremely faint, thus extreme
sensitivity and systematic control are necessary in order to attempt this
measurement. QUBIC addresses these requirements using an innovative approach
combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with
the deep control of systematics characteristic of interferometers. This makes
QUBIC unique with respect to others classical imagers experiments devoted to
the CMB polarization. In this contribution we report a description of the QUBIC
instrument including recent achievements and the demonstration of the
bolometric interferometry performed in lab. QUBIC will be deployed at the
observation site in Alto Chorrillos, in Argentina at the end of 2019.
[5]
oai:arXiv.org:1911.12418 [pdf] - 2011325
QUBIC: using NbSi TESs with a bolometric interferometer to characterize
the polarisation of the CMB
Piat, M.;
Bélier, B.;
Bergé, L.;
Bleurvacq, N.;
Chapron, C.;
Dheilly, S.;
Dumoulin, L.;
González, M.;
Grandsire, L.;
Hamilton, J. -Ch.;
Henrot-Versillé, S.;
Hoang, D. T.;
Marnieros, S.;
Marty, W.;
Montier, L.;
Olivieri, E.;
Oriol, C.;
Perbost, C.;
Prêle, D.;
Rambaud, D.;
Salatino, M.;
Stankowiak, G.;
Thermeau, J. -P.;
Torchinsky, S.;
Voisin, F.;
Ade, P.;
Alberro, J. G.;
Almela, A.;
Amico, G.;
Arnaldi, L. H.;
Auguste, D.;
Aumont, J.;
Azzoni, S.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bennett, D.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bonaparte, J.;
Bonis, J.;
Bottani, A.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Charlassier, R.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Di Donato, A.;
Etchegoyen, A.;
Fasciszewski, A.;
Ferreyro, L. P.;
Fracchia, D.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Ganga, K.;
García, B.;
Redondo, M. E. García;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Gilles, V.;
Giraud-Heraud, Y.;
Berisso, M. Gómez;
Gradziel, M.;
Harari, D.;
Haynes, V.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Luterstein, R.;
Maffei, B.;
Masi, S.;
Mattei, A.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Mennella, A.;
Mousset, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
Nati, F.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perciballi, M.;
Pezzotta, F.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Platino, M.;
Polenta, G.;
Puddu, R.;
Ringegni, P.;
Romero, G. E.;
Salum, J. M.;
Schillaci, A.;
Scóccola, C.;
Scully, S.;
Spinelli, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Tomasi, M.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Viganò, D.;
Vittorio, N.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2019-11-27, last modified: 2019-12-09
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international
ground-based experiment dedicated in the measurement of the polarized
fluctuations of the Cosmic Microwave Background (CMB). It is based on
bolometric interferometry, an original detection technique which combine the
immunity to systematic effects of an interferometer with the sensitivity of low
temperature incoherent detectors. QUBIC will be deployed in Argentina, at the
Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta
province.
The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors
(TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain
Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at
1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K
allowing to reach an unprecedented multiplexing (MUX) factor equal to 128.
The QUBIC experiment is currently being characterized in the lab with a
reduced number of detectors before upgrading to the full instrument. I will
present the last results of this characterization phase with a focus on the
detectors and readout system.
[6]
oai:arXiv.org:1812.00785 [pdf] - 1820173
QUBIC: Exploring the primordial Universe with the Q\&U Bolometric
Interferometer
Mennella, Aniello;
Ade, Peter;
Amico, Giorgio;
Auguste, Didier;
Aumont, Jonathan;
Banfi, Stefano;
Barbaràn, Gustavo;
Battaglia, Paola;
Battistelli, Elia;
Baù, Alessandro;
Bélier, Benoit;
Bennett, David G.;
Bergé, Laurent;
Bernard, Jean Philippe;
Bersanelli, Marco;
Sazy, Marie Anne Bigot;
Bleurvacq, Nathat;
Bonaparte, Juan;
Bonis, Julien;
Bunn, Emory F.;
Burke, David;
Buzi, Daniele;
Buzzelli, Alessandro;
Cavaliere, Francesco;
Chanial, Pierre;
Chapron, Claude;
Charlassier, Romain;
Columbro, Fabio;
Coppi, Gabriele;
Coppolecchia, Alessandro;
D'Agostino, Rocco;
D'Alessandro, Giuseppe;
De Bernardis, Paolo;
De Gasperis, Giancarlo;
De Leo, Michele;
De Petris, Marco;
Di Donato, Andres;
Dumoulin, Louis;
Etchegoyen, Alberto;
Fasciszewski, Adrián;
Franceschet, Cristian;
Lerena, Martin Miguel Gamboa;
Garcia, Beatriz;
Garrido, Xavier;
Gaspard, Michel;
Gault, Amanda;
Gayer, Donnacha;
Gervasi, Massimo;
Giard, Martin;
Héraud, Yannick Giraud;
Berisso, Mariano Gómez;
González, Manuel;
Gradziel, Marcin;
Grandsire, Laurent;
Guerard, Eric;
Hamilton, Jean Christophe;
Harari, Diego;
Haynes, Vic;
Versillé, Sophie Henrot;
Hoang, Duc Thuong;
Holtzer, Nicolas;
Incardona, Federico;
Jules, Eric;
Kaplan, Jean;
Korotkov, Andrei;
Kristukat, Christian;
Lamagna, Luca;
Loucatos, Soutiris;
Lowitz, Amy;
Lukovic, Vladimir;
Thibault, Louis;
Luterstein, Raùl Horacio;
Maffei, Bruno;
Marnieros, Stefanos;
Masi, Silvia;
Mattei, Angelo;
May, Andrew;
McCulloch, Mark;
Medina, Maria C.;
Mele, Lorenzo;
Melhuish, Simon J.;
Montier, Ludovic;
Mousset, Louise;
Mundo, Luis Mariano;
Murphy, John Anthony;
Murphy, James;
O'Sullivan, Creidhe;
Olivieri, Emiliano;
Paiella, Alessandro;
Pajot, Francois;
Passerini, Andrea;
Pastoriza, Hernan;
Pelosi, Alessandro;
Perbost, Camille;
Perciballi, Maurizio;
Pezzotta, Federico;
Piacentini, Francesco;
Piat, Michel;
Piccirillo, Lucio;
Pisano, Giampaolo;
Polenta, Gianluca;
Prêle, Damien;
Puddu, Roberto;
Rambaud, Damien;
Ringegni, Pablo;
Romero, Gustavo E.;
Salatino, Maria;
Schillaci, Alessandro;
Scóccola, Claudia G.;
Scully, Stephen P.;
Spinelli, Sebastiano;
Stolpovskiy, Michail;
Suarez, Federico;
Stankowiak, Guillaume;
Tartari, Andrea;
Thermeau, Jean Pierre;
Timbie, Peter;
Tomasi, Maurizio;
Torchinsky, Steve A.;
Tristram, Mathieu;
Tucker, Gregory S.;
Tucker, Carole E.;
Vanneste, Sylvain;
Viganò, Daniele;
Vittorio, Nicola;
Voisin, Fabrice;
Watson, Robert;
Wicek, Francois;
Zannoni, Mario;
Zullo, Antonio
Submitted: 2018-11-30, last modified: 2019-01-23
In this paper we describe QUBIC, an experiment that will observe the
polarized microwave sky with a novel approach, which combines the sensitivity
of state-of-the art bolometric detectors with the systematic effects control
typical of interferometers. QUBIC unique features are the so-called
"self-calibration", a technique that allows us to clean the measured data from
instrumental effects, and its spectral imaging power, i.e. the ability to
separate the signal in various sub-bands within each frequency band. QUBIC will
observe the sky in two main frequency bands: 150 GHz and 220 GHz. A
technological demonstrator is currently under testing and will be deployed in
Argentina during 2019, while the final instrument is expected to be installed
during 2020.
[7]
oai:arXiv.org:1812.03687 [pdf] - 1795038
The STRIP instrument of the Large Scale Polarization Explorer: microwave
eyes to map the Galactic polarized foregrounds
Franceschet, C.;
Realini, S.;
Mennella, A.;
Addamo, G.;
Baù, A.;
Battaglia, P. M.;
Bersanelli, M.;
Caccianiga, B.;
Caprioli, S.;
Cavaliere, F.;
Cleary, K. A.;
Cuttaia, F.;
Del Torto, F.;
Fafone, V.;
Farooqui, Z.;
Santos, R. T. Génova;
Gaier, T. C.;
Gervasi, M.;
Ghigna, T.;
Incardona, F.;
Iovenitti, S.;
Jones, M.;
Kangaslahti, P.;
Mainini, R.;
Maino, D.;
Maris, M.;
Mena, P.;
Molina, R.;
Morgante, G.;
Passerini, A.;
Perez-de-Taoro, M.;
Peverini, O. A.;
Pezzotta, F.;
Pincella, C.;
Reyes, N.;
Rocchi, A.;
Rubiño-Martín, J. A.;
Sandri, M.;
Sartor, S.;
Soria, M.;
Tapia, V.;
Terenzi, L.;
Tomasi, M.;
Tommasi, E.;
Viganó, D. M.;
Villa, F.;
Virone, G.;
Volpe, A.;
Watkins, B.;
Zacchei, A.;
Zannoni, M.
Submitted: 2018-12-10
In this paper we discuss the latest developments of the STRIP instrument of
the "Large Scale Polarization Explorer" (LSPE) experiment. LSPE is a novel
project that combines ground-based (STRIP) and balloon-borne (SWIPE)
polarization measurements of the microwave sky on large angular scales to
attempt a detection of the "B-modes" of the Cosmic Microwave Background
polarization. STRIP will observe approximately 25% of the Northern sky from the
"Observatorio del Teide" in Tenerife, using an array of forty-nine coherent
polarimeters at 43 GHz, coupled to a 1.5 m fully rotating crossed-Dragone
telescope. A second frequency channel with six-elements at 95 GHz will be
exploited as an atmospheric monitor. At present, most of the hardware of the
STRIP instrument has been developed and tested at sub-system level.
System-level characterization, starting in July 2018, will lead STRIP to be
shipped and installed at the observation site within the end of the year. The
on-site verification and calibration of the whole instrument will prepare STRIP
for a 2-years campaign for the observation of the CMB polarization.
[8]
oai:arXiv.org:1811.02296 [pdf] - 1779826
Thermal architecture for the QUBIC cryogenic receiver
May, A. J.;
Chapron, C.;
Coppi, G.;
D'Alessandro, G.;
de Bernardis, P.;
Masi, S.;
Melhuish, S.;
Piat, M.;
Piccirillo, L.;
Schillaci, A.;
Thermeau, J. -P.;
Ade, P.;
Amico, G.;
Auguste, D.;
Aumont, J.;
Banfi, S.;
Barbara, G.;
Battaglia, P.;
Battistelli, E.;
Bau, A.;
Belier, B.;
Bennett, D.;
Berge, L.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bleurvacq, N.;
Bonaparte, J.;
Bonis, J.;
Bordier, G.;
Breelle, E.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Charlassier, R.;
Columbro, F.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Di Donato, A.;
Dumoulin, L.;
Etchegoyen, A.;
Fasciszewski, A.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Garcia, B.;
Garrido, X.;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Giraud-Heraud, Y.;
Berisso, M. Gomez;
Gonzalez, M.;
Gradziel, M.;
Grandsire, L.;
Guerrard, E.;
Hamilton, J. -Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versille, S.;
Hoang, D. T.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Lowitz, A.;
Lukovic, V.;
Luterstein, R.;
Maffei, B.;
Marnieros, S.;
Mattei, A.;
McCulloch, M. A.;
Medina, M. C.;
Mele, L.;
Mennella, A.;
Montier, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
O'Sullivan, C.;
Olivieri, E.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Pezzotta, F.;
Piacentini, F.;
Pisano, G.;
Polenta, G.;
Prele, D.;
Puddu, R.;
Rambaud, D.;
Ringegni, P.;
Romero, G. E.;
Salatino, M.;
Scoccola, C. G.;
Scully, S.;
Spinelli, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Torchinsky, S. A.;
Tristram, M.;
Truongcanh, V.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Vigano, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2018-11-06
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming
instrument to measure the B-mode polarization anisotropy of the Cosmic
Microwave Background. The detection of the B-mode signal will be extremely
challenging; QUBIC has been designed to address this with a novel approach,
namely bolometric interferometry. The receiver cryostat is exceptionally large
and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK
using two pulse tube coolers, a novel 4He sorption cooler and a double-stage
3He/4He sorption cooler. We discuss the thermal and mechanical design of the
cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
[9]
oai:arXiv.org:1801.03730 [pdf] - 1616675
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to
look at the polarized Cosmic Microwave Background
Mennella, A.;
Ade, P. A. R.;
Aumont, J.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bélier, B.;
Bennett, D.;
Bergé, L.;
Bernard, J. Ph.;
Bersanelli, M.;
Bigot-Sazy, M. A.;
Bleurvacq, N.;
Bordier, G.;
Brossard, J.;
Bunn, E. F.;
Burke, D. P.;
Buzi, D.;
Buzzelli, A.;
Cammilleri, D.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Decourcelle, T.;
Del Torto, F.;
Dumoulin, L.;
Etchegoyen, A.;
Franceschet, C.;
Garcia, B.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Ghribi, A.;
Giard, M.;
Giraud-Héraud, Y.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillé, S.;
Holtzer, N.;
Incardona, F.;
Kaplan, J.;
Korotkov, A.;
Krachmalnicoff, N.;
Lamagna, L.;
Lande, J.;
Loucatos, S.;
Lowitz, A.;
Lukovic, V.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Montier, L.;
Murphy, A.;
Néel, D.;
Ng, M. W.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Préle, D.;
Puddu, R.;
Rambaud, D.;
Rigaut, O.;
Romero, G. E.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Torchinsky, S.;
Tristram, M.;
Tucker, C.;
Tucker, G.;
Viganò, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Zannoni, M.;
Zullo, A.
Submitted: 2018-01-11
In this paper we describe QUBIC, an experiment that takes up the challenge
posed by the detection of primordial gravitational waves with a novel approach,
that combines the sensitivity of state-of-the art bolometric detectors with the
systematic effects control typical of interferometers. The so-called
"self-calibration" is a technique deeply rooted in the interferometric nature
of the instrument and allows us to clean the measured data from instrumental
effects. The first module of QUBIC is a dual band instrument (150 GHz and 220
GHz) that will be deployed in Argentina during the Fall 2018.
[10]
oai:arXiv.org:1609.04372 [pdf] - 1576378
QUBIC Technical Design Report
Aumont, J.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bélier, B.;
Bennett, D.;
Bergé, L.;
Bernard, J. Ph.;
Bersanelli, M.;
Bigot-Sazy, M. A.;
Bleurvacq, N.;
Bordier, G.;
Brossard, J.;
Bunn, E. F.;
Buzi, D.;
Buzzelli, A.;
Cammilleri, D.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Coppi, G.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Petris, M.;
Decourcelle, T.;
Del Torto, F.;
Dumoulin, L.;
Etchegoyen, A.;
Franceschet, C.;
Garcia, B.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Ghribi, A.;
Giard, M.;
Giraud-Héraud, Y.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillé, S.;
Holtzer, N.;
Kaplan, J.;
Korotkov, A.;
Lamagna, L.;
Lande, J.;
Loucatos, S.;
Lowitz, A.;
Lukovic, V.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Melhuish, S.;
Mennella, A.;
Montier, L.;
Murphy, A.;
Néel, D.;
Ng, M. W.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Prêle, D.;
Puddu, R.;
Rambaud, D.;
Rigaut, O.;
Romero, G. E.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Tristram, M.;
Tucker, G.;
Viganò, D.;
Vittori, N.;
Voisin, F.;
Watson, B.;
Zannoni, M.;
Zullo, A.
Submitted: 2016-09-14, last modified: 2017-05-11
QUBIC is an instrument aiming at measuring the B mode polarisation
anisotropies at medium scales angular scales (30-200 multipoles). The search
for the primordial CMB B-mode polarization signal is challenging, because of
many difficulties: smallness of the expected signal, instrumental systematics
that could possibly induce polarization leakage from the large E signal into B,
brighter than anticipated polarized foregrounds (dust) reducing to zero the
initial hope of finding sky regions clean enough to have a direct primordial
B-modes observation. The QUBIC instrument is designed to address all aspects of
this challenge with a novel kind of instrument, a Bolometric Interferometer,
combining the background-limited sensitivity of Transition-Edge-Sensors and the
control of systematics allowed by the observation of interference fringe
patterns, while operating at two frequencies to disentangle polarized
foregrounds from primordial B mode polarization. Its characteristics are
described in details in this Technological Design Report.
[11]
oai:arXiv.org:1307.5701 [pdf] - 1172881
Latest Progress on the QUBIC Instrument
Ghribi, A.;
Aumont, J.;
Battistelli, E. S.;
Bau, A.;
Bergé, L.;
Bernard, J-Ph.;
Bersanelli, M.;
Bigot-Sazy, M-A.;
Bordier, G.;
Bunn, E. T.;
Cavaliere, F.;
Chanial, P.;
Coppolecchia, A.;
Decourcelle, T.;
De Bernardis, P.;
De Petris, M.;
Drilien, A-A.;
Dumoulin, L.;
Falvella, M. C.;
Gault, A.;
Gervasi, M.;
Giard, M.;
Gradziel, M.;
Grandsire, L.;
Gayer, D.;
Hamilton, J-Ch.;
Haynes, V.;
Giraud-Héraud, Y.;
Holtzer, N.;
Kaplan, J.;
Korotkov, A.;
Lande, J.;
Lowitz, A.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
Mennella, A.;
Montier, L.;
Murphy, A.;
Ng, M. W.;
Olivieri, E.;
Pajot, F.;
Passerini, A.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Prêle, D.;
Rambaud, D.;
Rigaut, O.;
Rosset, C.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
O'Sullivan, C.;
Tartari, A.;
Timbie, P.;
Tucker, G.;
Vibert, L.;
Voisin, F.;
Watson, B.;
Zannoni, M.
Submitted: 2013-07-22, last modified: 2013-11-12
QUBIC is a unique instrument that crosses the barriers between classical
imaging architectures and interferometry taking advantage from both for high
sensitivity and systematics mitigation. The scientific target is the detection
of the primordial gravitational waves imprint on the Cosmic Microwave
Background which are the proof of inflation, holy grail of modern cosmology. In
this paper, we show the latest advances in the development of the architecture
and the sub-systems of the first module of this instrument to be deployed in
Dome Charlie Concordia base - Antarctica in 2015.
[12]
oai:arXiv.org:1307.6090 [pdf] - 715531
An improved upper limit to the CMB circular polarization at large
angular scales
Mainini, R.;
Minelli, D.;
Gervasi, M.;
Boella, G.;
Sironi, G.;
Bau', A.;
Banfi, S.;
Passerini, A.;
De Lucia, A.;
Cavaliere, F.
Submitted: 2013-07-23, last modified: 2013-09-04
Circular polarization of the Cosmic Microwave Background (CMB) offers the
possibility of detecting rotations of the universe and magnetic fields in the
primeval universe or in distant clusters of galaxies. We used the Milano
Polarimeter (MIPOL) installed at the Testa Grigia Observatory, on the italian
Alps, to improve the existing upper limits to the CMB circular polarization at
large angular scales. We obtain 95% confidence level upper limits to the degree
of the CMB circular polarization ranging between 5.0x10^{-4} and 0.7x10^{-4} at
angular scales between 8 and 24 deg, improving by one order of magnitude
preexisting upper limits at large angular scales. Our results are still far
from the nK region where today expectations place the amplitude of the V Stokes
parameter used to characterize circular polarization of the CMB but improve the
preexisting limit at similar angular scales. Our observations offered also the
opportunity of characterizing the atmospheric emission at 33 GHz at the Testa
Grigia Observatory.
[13]
oai:arXiv.org:1208.0164 [pdf] - 1150428
A coherent polarimeter array for the Large Scale Polarization Explorer
balloon experiment
Bersanelli, M.;
Mennella, A.;
Morgante, G.;
Zannoni, M.;
Addamo, G.;
Baschirotto, A.;
Battaglia, P.;
Baù, A.;
Cappellini, B.;
Cavaliere, F.;
Cuttaia, F.;
Del Torto, F.;
Donzelli, S.;
Farooqui, Z.;
Frailis, M.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gervasi, M.;
Gregorio, A.;
Kangaslahti, P.;
Krachmalnicoff, N.;
Lawrence, C.;
Maggio, G.;
Mainini, R.;
Maino, D.;
Mandolesi, N.;
Paroli, B.;
Passerini, A.;
Peverini, O. A.;
Poli, S.;
Ricciardi, S.;
Rossetti, M.;
Sandri, M.;
Seiffert, M.;
Stringhetti, L.;
Tartari, A.;
Tascone, R.;
Tavagnacco, D.;
Terenzi, L.;
Tomasi, M.;
Tommasi, E.;
Villa, F.;
Virone, G.;
Zacchei, A.
Submitted: 2012-08-01
We discuss the design and expected performance of STRIP (STRatospheric
Italian Polarimeter), an array of coherent receivers designed to fly on board
the LSPE (Large Scale Polarization Explorer) balloon experiment. The STRIP
focal plane array comprises 49 elements in Q band and 7 elements in W-band
using cryogenic HEMT low noise amplifiers and high performance waveguide
components. In operation, the array will be cooled to 20 K and placed in the
focal plane of a $\sim 0.6$ meter telescope providing an angular resolution of
$\sim1.5$ degrees. The LSPE experiment aims at large scale, high sensitivity
measurements of CMB polarization, with multi-frequency deep measurements to
optimize component separation. The STRIP Q-band channel is crucial to
accurately measure and remove the synchrotron polarized component, while the
W-band channel, together with a bolometric channel at the same frequency,
provides a crucial cross-check for systematic effects.
[14]
oai:arXiv.org:1208.0281 [pdf] - 544717
The Large-Scale Polarization Explorer (LSPE)
The LSPE collaboration;
Aiola, S.;
Amico, G.;
Battaglia, P.;
Battistelli, E.;
Baù, A.;
de Bernardis, P.;
Bersanelli, M.;
Boscaleri, A.;
Cavaliere, F.;
Coppolecchia, A.;
Cruciani, A.;
Cuttaia, F.;
Addabbo, A. D';
D'Alessandro, G.;
De Gregori, S.;
Del Torto, F.;
De Petris, M.;
Fiorineschi, L.;
Franceschet, C.;
Franceschi, E.;
Gervasi, M.;
Goldie, D.;
Gregorio, A.;
Haynes, V.;
Krachmalnicoff, N.;
Lamagna, L.;
Maffei, B.;
Maino, D.;
Masi, S.;
Mennella, A.;
Wah, Ng Ming;
Morgante, G.;
Nati, F.;
Pagano, L.;
Passerini, A.;
Peverini, O.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Ricciardi, S.;
Rissone, P.;
Romeo, G.;
Salatino, M.;
Sandri, M.;
Schillaci, A.;
Stringhetti, L.;
Tartari, A.;
Tascone, R.;
Terenzi, L.;
Tomasi, M.;
Tommasi, E.;
Villa, F.;
Virone, G.;
Withington, S.;
Zacchei, A.;
Zannoni, M.
Submitted: 2012-08-01
The LSPE is a balloon-borne mission aimed at measuring the polarization of
the Cosmic Microwave Background (CMB) at large angular scales, and in
particular to constrain the curl component of CMB polarization (B-modes)
produced by tensor perturbations generated during cosmic inflation, in the very
early universe. Its primary target is to improve the limit on the ratio of
tensor to scalar perturbations amplitudes down to r = 0.03, at 99.7%
confidence. A second target is to produce wide maps of foreground polarization
generated in our Galaxy by synchrotron emission and interstellar dust emission.
These will be important to map Galactic magnetic fields and to study the
properties of ionized gas and of diffuse interstellar dust in our Galaxy. The
mission is optimized for large angular scales, with coarse angular resolution
(around 1.5 degrees FWHM), and wide sky coverage (25% of the sky). The payload
will fly in a circumpolar long duration balloon mission during the polar night.
Using the Earth as a giant solar shield, the instrument will spin in azimuth,
observing a large fraction of the northern sky. The payload will host two
instruments. An array of coherent polarimeters using cryogenic HEMT amplifiers
will survey the sky at 43 and 90 GHz. An array of bolometric polarimeters,
using large throughput multi-mode bolometers and rotating Half Wave Plates
(HWP), will survey the same sky region in three bands at 95, 145 and 245 GHz.
The wide frequency coverage will allow optimal control of the polarized
foregrounds, with comparable angular resolution at all frequencies.
[15]
oai:arXiv.org:1107.1157 [pdf] - 382247
W-band prototype of platelet feed-horn array for CMB polarisation
measurements
Del Torto, Francesco;
Bersanelli, Marco;
Cavaliere, Francesco;
De Rosa, Adriano;
D'Arcangelo, Ocleto;
Franceschet, Cristian;
Gervasi, Massimo;
Mennella, Aniello;
Pagana, Enrico;
Simonetto, Alessandro;
Tartari, Andrea;
Villa, Fabrizio;
Zannoni, Mario
Submitted: 2011-07-06
We present the design and performance of a 2x2 prototype array of corrugated
feed-horns in W-band. The module is fabricated using a so-called "platelet"
technique by milling Aluminum plates. This technique is suitable for low-cost
and scalable high performance applications. Room temperature Return Loss
measurements show a low (<-30 dB) reflection over a 30% bandwidth with a
maximum matching of -42 dB at 100 GHz for all four antennas. Beam pattern
measurements indicate good repeatability and a low (-25 dB) sidelobe and
crosspolarisation levels. This work is particularly relevant for future Cosmic
Microwave Background polarisation measurements, which require large microwave
cryogenic detector arrays coupled to high performance corrugated feed horns.
[16]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[17]
oai:arXiv.org:1001.4644 [pdf] - 33160
Cryogenic environment and performance for testing the Planck radiometers
Terenzi, L.;
Lapolla, M.;
Laaninen, M.;
Battaglia, P.;
Cavaliere, F.;
De Rosa, A.;
Hughes, N.;
Jukkala, P.;
Kilpiä, V. -H.;
Morgante, G.;
Tomasi, M.;
Varis, J.;
Bersanelli, M.;
Butler, R. C.;
Ferrari, F.;
Franceschet, C.;
Leutenegger, P.;
Mandolesi, N.;
Mennella, A.;
Silvestri, R.;
Stringhetti, L.;
Tuovinen, J.;
Valenziano, L.;
Villa, F.
Submitted: 2010-01-26
This paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst
The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two
dedicated cryogenic facilities. In this paper the facilities and the related
instrumentation are described. The main satellite thermal interfaces for the
single chains have to be reproduced and stability requirements have to be
satisfied. Setup design, problems occurred and improving solutions implemented
are discussed. Performance of the cryogenic setup are reported.
[18]
oai:arXiv.org:1001.4778 [pdf] - 33192
Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
Valenziano, Luca;
Cuttaia, Francesco;
De Rosa, Adriano;
Terenzi, Luca;
Brighenti, Alberto;
Cazzola, GianPaolo;
Garbesi, Anna;
Mariotti, Sergio;
Orsi, Giordano;
Pagan, Luca;
Cavaliere, Francesco;
Lapini, Roberto;
Biggi, Matteo;
Panagin, Enzo;
Paola, Battaglia;
Butler, Chris;
Bersanelli, Marco;
D'Arcangelo, Ocleto;
Levin, Steve;
Mandolesi, Nazzareno;
Mennella, Aniello;
Morgante, Gianluca;
Morigi, Gabriele;
Sandri, Maura;
Simonetto, Alessandro;
Tomasi, Maurizio;
Villa, Fabrizio;
Frailis, Marco;
Galeotta, Samuele;
Gregorio, Anna;
Leonardi, Rodrigo;
Lowe, Stuart;
Maris, Michele;
Meinhold, Peter;
Mendes, Luis;
Stringhetti, Luca;
Zonca, Andrea;
Zacchei, Andrea
Submitted: 2010-01-26
The LFI radiometers use a pseudo-correlation design where the signal from the
sky is continuously compared with a stable reference signal, provided by a
cryogenic reference load system. The reference unit is composed by small
pyramidal horns, one for each radiometer, 22 in total, facing small absorbing
targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately
4.5 K. Horns and targets are separated by a small gap to allow thermal
decoupling. Target and horn design is optimized for each of the LFI bands,
centered at 70, 44 and 30 GHz. Pyramidal horns are either machined inside the
radiometer 20K module or connected via external electro-formed bended
waveguides. The requirement of high stability of the reference signal imposed a
careful design for the radiometric and thermal properties of the loads.
Materials used for the manufacturing have been characterized for thermal, RF
and mechanical properties. We describe in this paper the design and the
performance of the reference system.
[19]
oai:arXiv.org:1001.4562 [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and
expected scientific performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R. J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Lawrence, C. R.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Morgante, G.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Valenziano, L.;
Villa, F.;
Zacchei, A.;
Zonca, A.;
Balasini, M.;
Franceschet, C.;
Battaglia, P.;
Lapolla, P. M.;
Leutenegger, P.;
Miccolis, M.;
Pagan, L.;
Silvestri, R.;
Aja, B.;
Artal, E.;
Baldan, G.;
Bastia, P.;
Bernardino, T.;
Boschini, L.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
de La Fuente, L.;
Edgeley, J.;
Falvella, M. C.;
Ferrari, F.;
Fogliani, S.;
Franceschi, E.;
Gaier, T.;
Gomez, F.;
Herreros, J. M.;
Hildebrandt, S.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Lawson, D.;
Leahy, P.;
Levin, S.;
Lilje, P. B.;
Maino, D.;
Malaspina, M.;
Manzato, P.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Pasian, F.;
Pascual, J. P.;
Pecora, M.;
Peres-Cuevas, L.;
Platania, P.;
Pospieszalsky, M.;
Poutanen, T.;
Rebolo, R.;
Roddis, N.;
Salmon, M.;
Seiffert, M.;
Simonetto, A.;
Sozzi, C.;
Tauber, J.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck
Low Frequency Instrument (LFI) measured during the ground cryogenic test
campaign. These parameters characterise the instrument response and constitute
our best pre-launch knowledge of the LFI scientific performance. The LFI shows
excellent $1/f$ stability and rejection of instrumental systematic effects;
measured noise performance shows that LFI is the most sensitive instrument of
its kind. The set of measured calibration parameters will be updated during
flight operations through the end of the mission.
[20]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.
[21]
oai:arXiv.org:0912.2558 [pdf] - 31711
1st Roman Young Researchers Meeting Proceedings
Cannuccia, E.;
Migliaccio, M.;
Pietrobon, D.;
Stellato, F.;
Veneziani, M.;
Sabbatini, L.;
Dall'Oglio, G.;
Pizzo, L.;
Cavaliere, F.;
Miriametro, A.;
Gallerani, S.;
Santini, P.;
D'Ammando, F.;
Vercellone, S.;
Donnarumma, I.;
Pacciani, L.;
Pucella, G.;
Tavani, M.;
Vittorini, V.;
Bulgarelli, A.;
Chen, A. W.;
Giuliani, A.;
Longo, F.;
Paggi, A.;
Turriziani, S.;
Abundo, P.;
Armisi, L.;
Gori, F.;
Rosato, N.;
Cattani, G.;
Racioppi, A.;
Tarantino, W.
Submitted: 2009-12-13
During the last few decades scientists have been able to test the bases of
the physics paradigms, where the quantum mechanics has to match the
cosmological scales. Between the extremes of this scenario, biological
phenomena and their complexity take place, challenging the laws we observe in
the atomic and sub-atomic world. In order to explore the details of this world,
new huge experimental facilities are under construction. These projects involve
people coming from several countries and give physicists the opportunity to
work together with chemists, biologists and other scientists. The Roman Young
Researchers Meeting is a conference, organised by Ph. D. students and young
postdocs connected to the Roman area. It is aimed primarily at graduate
students and post-docs, working in physics. The 1st conference has been held on
the 21st of July 2009 at the University of Roma Tor Vergata. It was organised
in three sessions, devoted to Astrophysics and Cosmology, Soft and Condensed
Matter Physics and Theoretical and Particle Physics. In this proceeding we
collect the contributions which have been presented and discussed during the
meeting, according to the specific topics treated.
[22]
oai:arXiv.org:astro-ph/0301350 [pdf] - 54321
A dual output polarimeter devoted to the study of the Cosmic Microwave
Background
Submitted: 2003-01-17, last modified: 2003-01-21
We have developed a correlation radiometer at 33 GHz devoted to the search
for residual polarization of the Cosmic Microwave Background (CMB). The two
instruments`s outputs are linear combination of two Stokes Parameters (Q and U
or U and V). The instrument is therefore directly sensitive to the polarized
component of the radiation (respectively linear and circular). The radiometer
has a beam-width oif 7 or 14 deg, but it can be coupled to a telescope
increasing the resolution. The expected CMB polarization is at most a part per
milion. The polarimeter has been designed to be sensitive to this faint signal,
and it has been optimized to improve its long term stability, observing from
the ground. In this contribution the performances of the instrument are
presented, together with the preliminary test and observations.
[23]
oai:arXiv.org:astro-ph/0301354 [pdf] - 54325
Search for distortions in the spectrum of the Cosmic Microwave Radiation
Submitted: 2003-01-17
We present preliminary results of TRIS, an experiment dedicated to the search
of deviations from a pure planckian distribution in the spectrum of the Cosmic
Microwave Background at frequencies close to 1 GHz