oai:arXiv.org:1001.4743 [pdf] - 33184
Design, development and verification of the 30 and 44 GHz front-end
modules for the Planck Low Frequency Instrument
Davis, R. J.;
Wilkinson, A.;
Davies, R. D.;
Winder, W. F.;
Roddis, N.;
Blackhurst, E. J.;
Lawson, D.;
Lowe, S. R.;
Baines, C.;
Butlin, M.;
Galtress, A.;
Shepherd, D.;
Aja, B.;
Artal, E.;
Bersanelli, M.;
Butler, R. C.;
Castelli, C.;
Cuttaia, F.;
D'Arcangelo, O.;
Gaier, T.;
Hoyland, R.;
Kettle, D.;
Leonardi, R.;
Mandolesi, N.;
Mennella, A.;
Meinhold, P.;
Pospieszalski, M.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zonca, A.
Submitted: 2010-01-26
We give a description of the design, construction and testing of the 30 and
44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the
Planck mission to be launched in 2009. The scientific requirements of the
mission determine the performance parameters to be met by the FEMs, including
their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in
which the signal from the sky is compared with a 4-K blackbody load. The Low
Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High
Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel
phase-switch design which gives excellent amplitude and phase match across the
band.
The noise temperature requirements are met within the measurement errors at
the two frequencies. For the most sensitive LNAs, the noise temperature at the
band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively.
For some of the FEMs, the noise temperature is still falling as the ambient
temperature is reduced to 20 K. Stability tests of the FEMs, including a
measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all
critical aspects. The most sensitive LNAs have reached new limits of noise
temperature for HEMTs at their band centres. The FEMs have well-defined linear
polarization characteristcs.
[2]
oai:arXiv.org:astro-ph/0307116 [pdf] - 57829
Advanced pseudo-correlation radiometers for the Planck-LFI instrument
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Maino, D.;
Mandolesi, N.;
Morgante, G.;
Valenziano, L.;
Villa, F.;
Gaier, T.;
Seiffert, M.;
Levin, S.;
Lawrence, C.;
Meinhold, P.;
Lubin, P.;
Tuovinen, J.;
Varis, J.;
Karttaavi, T.;
Hughes, N.;
Jukkala, P.;
Sjman, P.;
Kangaslahti, P.;
Roddis, N.;
Kettle, D.;
Winder, F.;
Blackhurst, E.;
Davis, R.;
Wilkinson, A.;
Castelli, C.;
Aja, B.;
Artal, E.;
de la Fuente, L.;
Mediavilla, A.;
Pascual, J. P.;
Gallegos, J.;
Martinez-Gonzalez, E.;
de Paco, P.;
Pradell, L.
Submitted: 2003-07-07
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is
constituted by an array of radiometric detectors actively cooled at 20 K in the
30-70 GHz frequency range in the focal plane of the Planck telescope. In this
paper we present an overview of the LFI instrument, with a particular focus on
the radiometer design. The adopted pseudo-correlation scheme uses a software
balancing technique (with a tunable parameter called gain modulation factor)
which is effective in reducing the radiometer susceptibility to amplifier
instabilities also in presence of small non-idealities in the radiometric chain
components, provided that the gain modulation factor is estimated with an
accuracy of the order of 0.2%. These results have been recently confirmed by
experimental laboratory measurements conducted on the LFI prototype radiometers
at 30, 70 and 100 GHz.
[3]
oai:arXiv.org:astro-ph/9711027 [pdf] - 99160
Final performances of the X-ray Mirrors of the JET-X telescope
Poretti, E.;
Campana, S.;
Citterio, O.;
Conconi, P.;
Ghigo, M.;
Mazzoleni, F.;
Tagliaferri, G.;
Cusumano, G.;
La Rosa, G.;
Brauninger, W.;
Burkert, W.;
Castelli, C. M.;
Willingale, R.
Submitted: 1997-11-04
The Joint European Telesscope (JET-X) is one of the core scientific
instruments of the SPECTRUM-X-Gamma mission. JET-X was designed to study X-ray
emissions in the band 0.3-10 KeV. Its angular resolution is better than 20
arcsec; the values of the effective areas are 161 cm2 at 1.5 KeV and 69 cm2 at
8 Kev (for one telescope). The value of the HEW circle in function of the
off-axis angle is presented; it is found to be below 20 arcsec at 1.5 Kev and
around 23 arcsec at 8 KeV up to an off-axis angle of 12 arcmin.