Normalized to: Castel, J.
[1]
oai:arXiv.org:1910.13957 [pdf] - 2097246
The TREX-DM experiment at the Canfranc Underground Laboratory
Castel, J;
Cebrián, S;
Dafni, T;
Galán, J;
Irastorza, IG;
Luzón, G;
Margalejo, C;
Mirallas, H;
de Solórzano, A Ortiz;
Peiró, A;
Ruiz-Chóliz, E
Submitted: 2019-10-30, last modified: 2020-03-22
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for
low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using
light elements (Ne, Ar) as target in a high pressure TPC equipped with
Micromegas readouts. Here, a description of the detector, the first results
from commissioning data and the expected sensitivity from the developed
background model are briefly presented.
[2]
oai:arXiv.org:1812.04519 [pdf] - 1983798
Background assessment for the TREX Dark Matter experiment
Castel, J.;
Cebrian, S.;
Coarasa, I.;
Dafni, T.;
Galan, J.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Mirallas, H.;
de Solorzano, A. Ortiz;
Ruiz-Choliz, E.
Submitted: 2018-12-11, last modified: 2019-09-22
TREX-DM is conceived to look for low-mass Weakly Interacting Massive
Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas
readout planes at the Canfranc Underground Laboratory. The detector can hold in
the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30
kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered
acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low
background level in the lowest energy region is another essential requirement.
To assess the expected background, all the relevant sources have been
considered, including the measured fluxes of gamma radiation, muons and
neutrons at the Canfranc Laboratory, together with the activity of most of the
components used in the detector and ancillary systems, obtained in a complete
assay program. The background contributions have been simulated by means of a
dedicated application based on Geant4 and a custom-made code for the detector
response. The background model developed for the detector presently installed
in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region
of interest, making TREX-DM competitive in the search for low-mass WIMPs. A
roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
[3]
oai:arXiv.org:1906.01084 [pdf] - 1894436
First Results on the Search for Chameleons with the KWISP Detector at
CAST
Cuendis, S. Arguedas;
Baier, J.;
Barth, K.;
Baum, S.;
Bayirli, A.;
Belov, A.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Castel, J. F.;
Cetin, S. A.;
Dafni, T.;
Davenport, M.;
Dermenev, A.;
Desch, K.;
Döbrich, B.;
Fischer, H.;
Funk, W.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gninenko, S.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jakovčić, K.;
Kaminski, J.;
Karuza, M.;
Krieger, C.;
Lakić, B.;
Laurent, J. M.;
Luzón, G.;
Maroudas, M.;
Miceli, L.;
Neff, S.;
Ortega, I.;
Ozbey, A.;
Pivovaroff, M. J.;
Rosu, M.;
Ruz, J.;
Chóliz, E. Ruiz;
Schmidt, S.;
Schumann, M.;
Semertzidis, Y. K.;
Solanki, S. K.;
Stewart, L.;
Tsagris, I.;
Vafeiadis, T.;
Vogel, J. K.;
Vretenar, M.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2019-06-03
We report on a first measurement with a sensitive opto-mechanical force
sensor designed for the direct detection of coupling of real chameleons to
matter. These dark energy candidates could be produced in the Sun and stream
unimpeded to Earth. The KWISP detector installed on the CAST axion search
experiment at CERN looks for tiny displacements of a thin membrane caused by
the mechanical effect of solar chameleons. The displacements are detected by a
Michelson interferometer with a homodyne readout scheme. The sensor benefits
from the focusing action of the ABRIXAS X-ray telescope installed at CAST,
which increases the chameleon flux on the membrane. A mechanical chopper placed
between the telescope output and the detector modulates the incoming chameleon
stream. We present the results of the solar chameleon measurements taken at
CAST in July 2017, setting an upper bound on the force acting on the membrane
of $80$~pN at 95\% confidence level. The detector is sensitive for direct
coupling to matter $10^4 \leq\beta_m \leq 10^8$, where the coupling to photons
is locally bound to $\beta_\gamma \leq 10^{11}$.
[4]
oai:arXiv.org:1706.05818 [pdf] - 1598065
Cosmogenic production of tritium in dark matter detectors
Amare, J.;
Castel, J.;
Cebrian, S.;
Coarasa, I.;
Cuesta, C.;
Dafni, T.;
Galan, J.;
Garcia, E.;
Garza, J. G.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Martinez, M.;
Mirallas, H.;
Olivan, M. A.;
Ortigoza, Y.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Ruiz-Choliz, E.;
Sarsa, M. L.;
Villar, J. A.;
Villar, P.
Submitted: 2017-06-19, last modified: 2017-11-24
The direct detection of dark matter particles requires ultra-low background
conditions at energies below a few tens of keV. Radioactive isotopes are
produced via cosmogenic activation in detectors and other materials and those
isotopes constitute a background source which has to be under control. In
particular, tritium is specially relevant due to its decay properties (very low
endpoint energy and long half-life) when induced in the detector medium, and
because it can be generated in any material as a spallation product.
Quantification of cosmogenic production of tritium is not straightforward,
neither experimentally nor by calculations. In this work, a method for the
calculation of production rates at sea level has been developed and applied to
some of the materials typically used as targets in dark matter detectors
(germanium, sodium iodide, argon and neon); it is based on a selected
description of tritium production cross sections over the entire energy range
of cosmic nucleons. Results have been compared to available data in the
literature, either based on other calculations or from measurements. The
obtained tritium production rates, ranging from a few tens to a few hundreds of
nuclei per kg and per day at sea level, point to a significant contribution to
the background in dark matter experiments, requiring the application of
specific protocols for target material purification, material storing
underground and limiting the time the detector is on surface during the
building process in order to minimize the exposure to the most dangerous cosmic
ray components.
[5]
oai:arXiv.org:1709.10062 [pdf] - 1589033
Status of the TREX-DM experiment at the Canfranc Underground Laboratory
Aznar, F;
Castel, J;
Cebrian, S;
Coarasa, I;
Dafni, T;
Galan, J;
Garza, JG;
Iguaz, FJ;
Irastorza, IG;
Luzon, G;
Mirallas, H;
de Solorzano, A Ortiz;
Ruiz-Choliz, E;
Villar, JA
Submitted: 2017-09-28
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a
gas time projection chamber equipped with novel micromegas readout planes at
the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized
gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg
of Ne. The micromegas will be read with a self-triggered acquisition, allowing
for effective thresholds below 0.4 keV (electron equivalent). The preliminary
background model, following a complete material screening program, points to
levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest,
making TREX-DM competitive. The status of the commissioning, description of the
background model and the corresponding WIMP sensitivity will be presented here.
[6]
oai:arXiv.org:1509.06190 [pdf] - 1323484
A Micromegas-based low-background x-ray detector coupled to a
slumped-glass telescope for axion research
Aznar, F.;
Castel, J.;
Christensen, F. E.;
Dafni, T.;
Decker, T. A.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Giomataris, I.;
Gracia, J. G.;
Hailey, C. J.;
Hill, R. M.;
Iguaz, F. J.;
Irastorza, I. G.;
Jakobsen, A. C.;
Luzon, G.;
Mirallas, H.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Ruz, J.;
Vafeiadis, T.;
Vogel, J. K.
Submitted: 2015-09-21
We report on the design, construction and operation of a low background x-ray
detection line composed of a shielded Micromegas (micromesh gaseous structure)
detector of the microbulk technique. The detector is made from radiopure
materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m
focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of
thermally-formed (or "slumped") glass substrates deposited with multilayer
coatings. The system has been conceived as a technological pathfinder for the
future International Axion Observatory (IAXO), as it combines two of the
techniques (optic and detector) proposed in the conceptual design of the
project. It is innovative for two reasons: it is the first time an x-ray optic
has been designed and fabricated specifically for axion research, and the first
time a Micromegas detector has been operated with an x-ray optic. The line has
been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and
is currently looking for solar axions. The combination of the XRT and
Micromegas detector provides the best signal-to-noise ratio obtained so far by
any detection system of the CAST experiment with a background rate of
5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and
signal spot area.
[7]
oai:arXiv.org:1501.01626 [pdf] - 918886
Characterization of a Spherical Proportional Counter in argon-based
mixtures
Submitted: 2015-01-07
The Spherical Proportional Counter is a novel type of radiation detector,
with a low energy threshold (typically below 100 eV) and good energy
resolution. This detector is being developed by the network NEWS, which
includes several applications. We can name between many others Dark Matter
searches, low level radon and neutron counting or low energy neutrino detection
from supernovas or nuclear reactors via neutrino-nucleus elastic scattering. In
this context, this works will present the characterization of a spherical
detector of 1 meter diameter using two argon-based mixtures (with methane and
isobutane) and for gas pressures between 50 and 1250 mbar. In each case, the
energy resolution shows its best value in a wide range of gains, limited by the
ballistic effect at low gains and by ion-backflow at high gains. Moreover, the
best energy resolution shows a degradation with pressure. These effects will be
discussed in terms of gas avalanche properties. Finally, the effect of an
electrical field corrector in the homogenity of the gain and the energy
threshold measured in our setup will be also discussed.
[8]
oai:arXiv.org:1501.01466 [pdf] - 918435
Lowering the background level and the energy threshold of Micromegas
x-ray detectors for axion searches
Iguaz, F. J.;
Aune, S.;
Aznar, F.;
Castel, J. F.;
Dafni, T.;
Davenport, M.;
Ferrer-Ribas, E.;
Galan, J.;
Garcia, J. A.;
Garza, J. G.;
Giomataris, I.;
Irastorza, I. G.;
Papaevangelou, T.;
Rodriguez, A.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2015-01-07
Axion helioscopes search for solar axions by their conversion in x-rays in
the presence of high magnetic fields. The use of low background x-ray detectors
is an essential component contributing to the sensitivity of these searches. In
this work, we review the recent advances on Micromegas detectors used in the
CERN Axion Solar Telescope (CAST) and proposed for the future International
Axion Observatory (IAXO). The actual setup in CAST has achieved background
levels below 10$^{-6}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$, a factor 100 lower than
the first generation of Micromegas detectors. This reduction is based on active
and passive shielding techniques, the selection of radiopure materials, offline
discrimination techniques and the high granularity of the readout. We describe
in detail the background model of the detector, based on its operation at CAST
site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4
simulations. The best levels currently achieved at LSC are low than 10$^{-7}$
keV$^{-1}$ cm$^{-2}$ s$^{-1}$ and show good prospects for the application of
this technology in IAXO. Finally, we present some ideas and results for
reducing the energy threshold of these detectors below 1 keV, using
high-transparent windows, autotrigger electronics and studying the cluster
shape at different energies. As a high flux of axion-like-particles is expected
in this energy range, a sub-keV threshold detector could enlarge the physics
case of axion helioscopes.