Normalized to: Case, S.
[1]
oai:arXiv.org:2001.04046 [pdf] - 2034602
First demonstration of OH suppression in a high efficiency near-infrared
spectrograph
Ellis, S. C.;
Bland-Hawthorn, J.;
Lawrence, J. S.;
Horton, A. J.;
Content, R.;
Roth, M. M.;
Pai, N.;
Zhelem, R.;
Case, S.;
Hernandez, E.;
Leon-Saval, S. G.;
Haynes, R.;
Min, S. S.;
Giannone, D.;
Madhav, K.;
Rahman, A.;
Betters, C.;
Haynes, D.;
Couch, W.;
Kewley, L. J.;
McDermid, R.;
Spitler, L.;
Sharp, R. G.;
Veilleux, S.
Submitted: 2020-01-12
Ground-based near-infrared astronomy is severely hampered by the forest of
atmospheric emission lines resulting from the rovibrational decay of OH
molecules in the upper atmosphere. The extreme brightness of these lines, as
well as their spatial and temporal variability, makes accurate sky subtraction
difficult. Selectively filtering these lines with OH suppression instruments
has been a long standing goal for near-infrared spectroscopy. We have shown
previously the efficacy of fibre Bragg gratings combined with photonic lanterns
for achieving OH suppression. Here we report on PRAXIS, a unique near-infrared
spectrograph that is optimised for OH suppression with fibre Bragg gratings. We
show for the first time that OH suppression (of any kind) is possible with high
overall throughput (18 per cent end-to-end), and provide examples of the
relative benefits of OH suppression.
[2]
oai:arXiv.org:1903.02464 [pdf] - 1859121
4MOST: Project overview and information for the First Call for Proposals
de Jong, R. S.;
Agertz, O.;
Berbel, A. Agudo;
Aird, J.;
Alexander, D. A.;
Amarsi, A.;
Anders, F.;
Andrae, R.;
Ansarinejad, B.;
Ansorge, W.;
Antilogus, P.;
Anwand-Heerwart, H.;
Arentsen, A.;
Arnadottir, A.;
Asplund, M.;
Auger, M.;
Azais, N.;
Baade, D.;
Baker, G.;
Baker, S.;
Balbinot, E.;
Baldry, I. K.;
Banerji, M.;
Barden, S.;
Barklem, P.;
Barthélémy-Mazot, E.;
Battistini, C.;
Bauer, S.;
Bell, C. P. M.;
Bellido-Tirado, O.;
Bellstedt, S.;
Belokurov, V.;
Bensby, T.;
Bergemann, M.;
Bestenlehner, J. M.;
Bielby, R.;
Bilicki, M.;
Blake, C.;
Bland-Hawthorn, J.;
Boeche, C.;
Boland, W.;
Boller, T.;
Bongard, S.;
Bongiorno, A.;
Bonifacio, P.;
Boudon, D.;
Brooks, D.;
Brown, M. J. I.;
Brown, R.;
Brüggen, M.;
Brynnel, J.;
Brzeski, J.;
Buchert, T.;
Buschkamp, P.;
Caffau, E.;
Caillier, P.;
Carrick, J.;
Casagrande, L.;
Case, S.;
Casey, A.;
Cesarini, I.;
Cescutti, G.;
Chapuis, D.;
Chiappini, C.;
Childress, M.;
Christlieb, N.;
Church, R.;
Cioni, M. -R. L.;
Cluver, M.;
Colless, M.;
Collett, T.;
Comparat, J.;
Cooper, A.;
Couch, W.;
Courbin, F.;
Croom, S.;
Croton, D.;
Daguisé, E.;
Dalton, G.;
Davies, L. J. M.;
Davis, T.;
de Laverny, P.;
Deason, A.;
Dionies, F.;
Disseau, K.;
Doel, P.;
Döscher, D.;
Driver, S. P.;
Dwelly, T.;
Eckert, D.;
Edge, A.;
Edvardsson, B.;
Youssoufi, D. El;
Elhaddad, A.;
Enke, H.;
Erfanianfar, G.;
Farrell, T.;
Fechner, T.;
Feiz, C.;
Feltzing, S.;
Ferreras, I.;
Feuerstein, D.;
Feuillet, D.;
Finoguenov, A.;
Ford, D.;
Fotopoulou, S.;
Fouesneau, M.;
Frenk, C.;
Frey, S.;
Gaessler, W.;
Geier, S.;
Fusillo, N. Gentile;
Gerhard, O.;
Giannantonio, T.;
Giannone, D.;
Gibson, B.;
Gillingham, P.;
González-Fernández, C.;
Gonzalez-Solares, E.;
Gottloeber, S.;
Gould, A.;
Grebel, E. K.;
Gueguen, A.;
Guiglion, G.;
Haehnelt, M.;
Hahn, T.;
Hansen, C. J.;
Hartman, H.;
Hauptner, K.;
Hawkins, K.;
Haynes, D.;
Haynes, R.;
Heiter, U.;
Helmi, A.;
Aguayo, C. Hernandez;
Hewett, P.;
Hinton, S.;
Hobbs, D.;
Hoenig, S.;
Hofman, D.;
Hook, I.;
Hopgood, J.;
Hopkins, A.;
Hourihane, A.;
Howes, L.;
Howlett, C.;
Huet, T.;
Irwin, M.;
Iwert, O.;
Jablonka, P.;
Jahn, T.;
Jahnke, K.;
Jarno, A.;
Jin, S.;
Jofre, P.;
Johl, D.;
Jones, D.;
Jönsson, H.;
Jordan, C.;
Karovicova, I.;
Khalatyan, A.;
Kelz, A.;
Kennicutt, R.;
King, D.;
Kitaura, F.;
Klar, J.;
Klauser, U.;
Kneib, J.;
Koch, A.;
Koposov, S.;
Kordopatis, G.;
Korn, A.;
Kosmalski, J.;
Kotak, R.;
Kovalev, M.;
Kreckel, K.;
Kripak, Y.;
Krumpe, M.;
Kuijken, K.;
Kunder, A.;
Kushniruk, I.;
Lam, M. I;
Lamer, G.;
Laurent, F.;
Lawrence, J.;
Lehmitz, M.;
Lemasle, B.;
Lewis, J.;
Li, B.;
Lidman, C.;
Lind, K.;
Liske, J.;
Lizon, J. -L.;
Loveday, J.;
Ludwig, H. -G.;
McDermid, R. M.;
Maguire, K.;
Mainieri, V.;
Mali, S.;
Mandel, H.;
Mandel, K.;
Mannering, L.;
Martell, S.;
Delgado, D. Martinez;
Matijevic, G.;
McGregor, H.;
McMahon, R.;
McMillan, P.;
Mena, O.;
Merloni, A.;
Meyer, M. J.;
Michel, C.;
Micheva, G.;
Migniau, J. -E.;
Minchev, I.;
Monari, G.;
Muller, R.;
Murphy, D.;
Muthukrishna, D.;
Nandra, K.;
Navarro, R.;
Ness, M.;
Nichani, V.;
Nichol, R.;
Nicklas, H.;
Niederhofer, F.;
Norberg, P.;
Obreschkow, D.;
Oliver, S.;
Owers, M.;
Pai, N.;
Pankratow, S.;
Parkinson, D.;
Parry, I.;
Paschke, J.;
Paterson, R.;
Pecontal, A.;
Phillips, D.;
Pillepich, A.;
Pinard, L.;
Pirard, J.;
Piskunov, N.;
Plank, V.;
Plüschke, D.;
Pons, E.;
Popesso, P.;
Power, C.;
Pragt, J.;
Pramskiy, A.;
Pryer, D.;
Quattri, M.;
Queiroz, A. B. de Andrade;
Quirrenbach, A.;
Rahurkar, S.;
Raichoor, A.;
Ramstedt, S.;
Rau, A.;
Recio-Blanco, A.;
Reiss, R.;
Renaud, F.;
Revaz, Y.;
Rhode, P.;
Richard, J.;
Richter, A. D.;
Rix, H. -W.;
Robotham, A. S. G.;
Roelfsema, R.;
Romaniello, M.;
Rosario, D.;
Rothmaier, F.;
Roukema, B.;
Ruchti, G.;
Rupprecht, G.;
Rybizki, J.;
Ryde, N.;
Saar, A.;
Sadler, E.;
Sahlén, M.;
Salvato, M.;
Sassolas, B.;
Saunders, W.;
Saviauk, A.;
Sbordone, L.;
Schmidt, T.;
Schnurr, O.;
Scholz, R. -D.;
Schwope, A.;
Seifert, W.;
Shanks, T.;
Sheinis, A.;
Sivov, T.;
Skúladóttir, Á.;
Smartt, S.;
Smedley, S.;
Smith, G.;
Smith, R.;
Sorce, J.;
Spitler, L.;
Starkenburg, E.;
Steinmetz, M.;
Stilz, I.;
Storm, J.;
Sullivan, M.;
Sutherland, W.;
Swann, E.;
Tamone, A.;
Taylor, E. N.;
Teillon, J.;
Tempel, E.;
ter Horst, R.;
Thi, W. -F.;
Tolstoy, E.;
Trager, S.;
Traven, G.;
Tremblay, P. -E.;
Tresse, L.;
Valentini, M.;
van de Weygaert, R.;
Ancker, M. van den;
Veljanoski, J.;
Venkatesan, S.;
Wagner, L.;
Wagner, K.;
Walcher, C. J.;
Waller, L.;
Walton, N.;
Wang, L.;
Winkler, R.;
Wisotzki, L.;
Worley, C. C.;
Worseck, G.;
Xiang, M.;
Xu, W.;
Yong, D.;
Zhao, C.;
Zheng, J.;
Zscheyge, F.;
Zucker, D.
Submitted: 2019-03-06, last modified: 2019-04-01
We introduce the 4-metre Multi-Object Spectroscopic Telescope (4MOST), a new
high-multiplex, wide-field spectroscopic survey facility under development for
the four-metre-class Visible and Infrared Survey Telescope for Astronomy
(VISTA) at Paranal. Its key specifications are: a large field of view (FoV) of
4.2 square degrees and a high multiplex capability, with 1624 fibres feeding
two low-resolution spectrographs ($R = \lambda/\Delta\lambda \sim 6500$), and
812 fibres transferring light to the high-resolution spectrograph ($R \sim
20\,000$). After a description of the instrument and its expected performance,
a short overview is given of its operational scheme and planned 4MOST
Consortium science; these aspects are covered in more detail in other articles
in this edition of The Messenger. Finally, the processes, schedules, and
policies concerning the selection of ESO Community Surveys are presented,
commencing with a singular opportunity to submit Letters of Intent for Public
Surveys during the first five years of 4MOST operations.
[3]
oai:arXiv.org:1807.01938 [pdf] - 1711133
Veloce Rosso: Australia's new precision radial velocity spectrograph
Gilbert, James;
Bergmann, Christoph;
Bloxham, Gabe;
Boz, Robert;
Brookfield, Robert;
Carkic, Tom;
Carter, Brad;
Case, Scott;
Churilov, Vladimir;
Ellis, Michael;
Gausachs, Gaston;
Gers, Luke;
Gray, Doug;
Herrald, Nicholas;
Ireland, Michael;
Jones, Damien;
Kripak, Yevgen;
Lawrence, Jon;
O'Brien, Ellie;
Price, Ian;
Robertson, Matthew;
Schwab, Christian;
Tinney, Chris;
Vaccarella, Annino;
Vest, Colin;
Wright, Duncan;
Zhelem, Ross
Submitted: 2018-07-05
Veloce is an ultra-stable fibre-fed R4 echelle spectrograph for the 3.9 m
Anglo-Australian Telescope. The first channel to be commissioned, Veloce
'Rosso', utilises multiple low-cost design innovations to obtain Doppler
velocities for Sun-like and M-dwarf stars at <1 m/s precision. The spectrograph
has an asymmetric white-pupil format with a 100-mm beam diameter, delivering
R>75,000 spectra over a 580-950 nm range for the Rosso channel. Simultaneous
calibration is provided by a single-mode pulsed laser frequency comb in tandem
with a traditional arc lamp. A bundle of 19 object fibres provides a 2.4" field
of view for full sampling of stellar targets from the AAT site. Veloce is
housed in dual environmental enclosures that maintain positive air pressure at
a stability of +/-0.3 mbar, with a thermal stability of +/-0.01 K on the
optical bench. We present a technical overview and early performance data from
Australia's next major spectroscopic machine.
[4]
oai:arXiv.org:1805.10761 [pdf] - 1689889
Starbug fibre positioning robots: performance and reliability
enhancements
Brown, David M.;
Case, Scott;
Gilbert, James;
Goodwin, Michael;
Jacobs, Daniel;
Kuehn, Kyler;
Lawrence, Jon;
Lorente, Nuria P. F.;
Nichani, Vijay;
Saunders, Will;
Staszak, Nick;
Tims, Julia
Submitted: 2018-05-28
Starbugs are miniature piezoelectric walking robots that can be operated in
parallel to position many payloads like optical fibers across a telescopes
focal plane. They consist of two concentric piezoelectric ceramic tubes that
walk with micron step size. In addition to individual optical fibers, Starbugs
have moved a payload of 0.75kg at several millimeters per second. The
Australian Astronomical Observatory previously developed prototype devices and
tested them in the laboratory. Now we are optimizing the Starbug design for
production and deployment in the TAIPAN instrument, which will be capable of
configuring 300 optical fibers over a six degree field-of-view on the UK
Schmidt Telescope within a few minutes. The TAIPAN instrument will demonstrate
the technology and capability for MANIFEST (Many Instrument Fiber-System)
proposed for the Giant Magellan Telescope. Design is addressing: connector
density and voltage limitations, mechanical reliability and construction
repeatability, field plate residues and scratching, metrology stability, and
facilitation of improved motion in all aspects of the design for later
evaluation. Here we present the new design features of the AAO TAIPAN Starbug.
[5]
oai:arXiv.org:1509.00129 [pdf] - 1530302
First Light Results from the Hermes Spectrograph at the AAT
Sheinis, Andrew;
Anguiano, Borja;
Asplund, Martin;
Bacigalupo, Carlos;
Barden, Sam;
Birchall, Michael;
Bland-Hawthorn, Joss;
Brzeski, Jurek;
Cannon, Russell;
Carollo, Daniela;
Case, Scott;
Casey, Andrew;
Churilov, Vladimir;
Warrick, Couch;
Dean, Robert;
De Silva, Gayandhi;
D'Orazi, Valentina;
Duong, Ly;
Farrell, Tony;
Fiegert, Kristin;
Freeman, Kenneth;
Gabriella, Frost;
Gers, Luke;
Goodwin, Michael;
Gray, Doug;
Green, Andrew;
Heald, Ron;
Heijmans, Jeroen;
Ireland, Michael;
Jones, Damien;
Kafle, Prajwal;
Keller, Stefan;
Klauser, Urs;
Kondrat, Yuriy;
Kos, Janez;
Lawrence, Jon;
Lee, Steve;
Mali, Slavko;
Martell, Sarah;
Mathews, Darren;
Mayfield, Don;
Miziarski, Stan;
Muller, Rolf;
Pai, Naveen;
Patterson, Robert;
Penny, Ed;
Orr, David;
Schlesinger, Katharine;
Sharma, Sanjib;
Shortridge, Keith;
Simpson, Jeffrey;
Smedley, Scott;
Smith, Greg;
Stafford, Darren;
Staszak, Nicholas;
Vuong, Minh;
Waller, Lewis;
de Boer, Elizabeth Wylie;
Xavier, Pascal;
Zheng, Jessica;
Zhelem, Ross;
Zucker, Daniel;
Zwitter, Tomaz
Submitted: 2015-08-31
The High Efficiency and Resolution Multi Element Spectrograph, HERMES, is a
facility-class optical spectrograph for the Anglo-Australian Telescope (AAT).
It is designed primarily for Galactic Archaeology, the first major attempt to
create a detailed understanding of galaxy formation and evolution by studying
the history of our own galaxy, the Milky Way. The goal of the GALAH survey is
to reconstruct the mass assembly history of the Milky Way through a detailed
chemical abundance study of one million stars. The spectrograph is based at the
AAT and is fed by the existing 2dF robotic fiber positioning system. The
spectrograph uses volume phase holographic gratings to achieve a spectral
resolving power of 28,000 in standard mode and also provides a high-resolution
mode ranging between 40,000 and 50,000 using a slit mask. The GALAH survey
requires an SNR greater than 100 for a star brightness of V ?= 14 in an
exposure time of one hour. The total spectral coverage of the four channels is
about 100 nm between 370 and 1000 nm for up to 392 simultaneous targets within
the 2-degree field of view. HERMES has been commissioned over three runs,
during bright time in October, November, and December 2013, in parallel with
the beginning of the GALAH pilot survey, which started in November 2013. We
present the first-light results from the commissioning run and the beginning of
the GALAH survey, including performance results such as throughput and
resolution, as well as instrument reliability.
[6]
oai:arXiv.org:1212.1201 [pdf] - 650886
GNOSIS: the first instrument to use fibre Bragg gratings for OH
suppression
Trinh, Christopher Q.;
Ellis, Simon C.;
Bland-Hawthorn, Joss;
Lawrence, Jon S.;
Horton, Anthony J.;
Leon-Saval, Sergio G.;
Shortridge, Keith;
Bryant, Julia;
Case, Scott;
Colless, Matthew;
Couch, Warick;
Freeman, Kenneth;
Loehmannsroeben, Hans-Gerd;
Gers, Luke;
Glazebrook, Karl;
Haynes, Roger;
Lee, Steve;
O'Byrne, John;
Miziarski, Stan;
Roth, Martin M.;
Schmidt, Brian;
Tinney, Christopher G.;
Zheng, Jessica
Submitted: 2012-12-05, last modified: 2013-04-11
GNOSIS is a prototype astrophotonic instrument that utilizes OH suppression
fibres consisting of fibre Bragg gratings and photonic lanterns to suppress the
103 brightest atmospheric emission doublets between 1.47-1.7 microns. GNOSIS
was commissioned at the 3.9-meter Anglo-Australian Telescope with the IRIS2
spectrograph to demonstrate the potential of OH suppression fibres, but may be
potentially used with any telescope and spectrograph combination. Unlike
previous atmospheric suppression techniques GNOSIS suppresses the lines before
dispersion and in a manner that depends purely on wavelength. We present the
instrument design and report the results of laboratory and on-sky tests from
commissioning. While these tests demonstrated high throughput and excellent
suppression of the skylines by the OH suppression fibres, surprisingly GNOSIS
produced no significant reduction in the interline background and the
sensitivity of GNOSIS and IRIS2 is about the same as IRIS2. It is unclear
whether the lack of reduction in the interline background is due to physical
sources or systematic errors as the observations are detector noise-dominated.
OH suppression fibres could potentially impact ground-based astronomy at the
level of adaptive optics or greater. However, until a clear reduction in the
interline background and the corresponding increasing in sensitivity is
demonstrated optimized OH suppression fibres paired with a fibre-fed
spectrograph will at least provide a real benefits at low resolving powers.
[7]
oai:arXiv.org:1301.0670 [pdf] - 610414
CYCLOPS2: the fibre image slicer upgrade for the UCLES high resolution
spectrograph
Horton, Anthony;
Tinney, C. G.;
Case, Scott;
Farrell, Tony;
Gers, Luke;
Jones, Damien;
Lawrence, Jon;
Miziarski, Stan;
Staszak, Nick;
Orr, David;
Vuong, Minh;
Waller, Lew;
Zhelem, Ross
Submitted: 2013-01-03
CYCLOPS2 is an upgrade for the UCLES high resolution spectrograph on the
Anglo-Australian Telescope, scheduled for commissioning in semester 2012A. By
replacing the 5 mirror Coud\'e train with a Cassegrain mounted fibre-based
image slicer CYCLOPS2 simultaneously provides improved throughput, reduced
aperture losses and increased spectral resolution. Sixteen optical fibres
collect light from a 5.0 arcsecond^2 area of sky and reformat it into the
equivalent of a 0.6 arcsecond wide slit, delivering a spectral resolution of R
= 70000 and up to twice as much flux as the standard 1 arcsecond slit of the
Coud\'e train. CYCLOPS2 also adds support for simultaneous ThAr wavelength
calibration via a dedicated fibre. CYCLOPS2 consists of three main components,
the fore-optics unit, fibre bundle and slit unit. The fore optics unit
incorporates magnification optics and a lenslet array and is designed to mount
to the CURE Cassegrain instrument interface, which provides acquisition,
guiding and calibration facilities. The fibre bundle transports the light from
the Cassegrain focus to the UCLES spectrograph at Coud\'e and also includes a
fibre mode scrambler. The slit unit consists of the fibre slit and relay optics
to project an image of the slit onto the entrance aperture of the UCLES
spectrograph. CYCLOPS2 builds on experience with the first generation CYCLOPS
fibre system, which we also describe in this paper. We present the science case
for an image slicing fibre feed for echelle spectroscopy and describe the
design of CYCLOPS and CYCLOPS2.
[8]
oai:arXiv.org:1206.6551 [pdf] - 1124455
Suppression of the near-infrared OH night sky lines with fibre Bragg
gratings - first results
Ellis, S. C.;
Bland-Hawthorn, J.;
Lawrence, J.;
Horton, A. J.;
Trinh, C.;
Leon-Saval, S. G.;
Shortridge, K.;
Bryant, J.;
Case, S.;
Colless, M.;
Couch, W.;
Freeman, K.;
Gers, L.;
Glazebrook, K.;
Haynes, R.;
Lee, S.;
Loehmannsroeben, H. -G.;
Byrne, J. O.;
Miziarski, S.;
Roth, M.;
Schmidt, B.;
Tinney, C. G.;
Zheng, J.
Submitted: 2012-06-27
The background noise between 1 and 1.8 microns in ground-based instruments is
dominated by atmospheric emission from hydroxyl molecules. We have built and
commissioned a new instrument, GNOSIS, which suppresses 103 OH doublets between
1.47 - 1.7 microns by a factor of ~1000 with a resolving power of ~10,000. We
present the first results from the commissioning of GNOSIS using the IRIS2
spectrograph at the AAT. The combined throughput of the GNOSIS fore-optics,
grating unit and relay optics is ~36 per cent, but this could be improved to
~46 per cent with a more optimal design. We measure strong suppression of the
OH lines, confirming that OH suppression with fibre Bragg gratings will be a
powerful technology for low resolution spectroscopy. The integrated OH
suppressed background between 1.5 and 1.7 microns is reduced by a factor of 9
compared to a control spectrum using the same system without suppression. The
potential of low resolution OH suppressed spectroscopy is illustrated with
example observations.
The GNOSIS background is dominated by detector dark current below 1.67
microns and by thermal emission above 1.67 microns. After subtracting these we
detect an unidentified residual interline component of ~ 860 +/ 210
ph/s/m^2/micron/arcsec^2. This component is equally bright in the suppressed
and control spectra. We have investigated the possible source of the interline
component, but were unable to discriminate between a possible instrumental
artifact and intrinsic atmospheric emission. Resolving the source of this
emission is crucial for the design of fully optimised OH suppression
spectrographs. The next generation OH suppression spectrograph will be focussed
on resolving the source of the interline component, taking advantage of better
optimisation for a FBG feed. We quantify the necessary improvements for an
optimal OH suppressing fibre spectrograph design.