sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Carter, M.

Normalized to: Carter, M.

9 article(s) in total. 105 co-authors, from 1 to 8 common article(s). Median position in authors list is 11,0.

[1]  oai:arXiv.org:1612.03506  [pdf] - 1533243
The calibration of read-out-streak photometry in the XMM-Newton Optical Monitor and the construction of a bright-source catalogue
Comments: Accepted for publication in MNRAS
Submitted: 2016-12-11
The dynamic range of the XMM-Newton Optical Monitor (XMM-OM) is limited at the bright end by coincidence loss, the superposition of multiple photons in the individual frames recorded from its micro-channel-plate (MCP) intensified charge-coupled device (CCD) detector. One way to overcome this limitation is to use photons that arrive during the frame transfer of the CCD, forming vertical read-out streaks for bright sources. We calibrate these read-out streaks for photometry of bright sources observed with XMM-OM. The bright source limit for read-out streak photometry is set by the recharge time of the MCPs. For XMM-OM we find that the MCP recharge time is 0.55 ms. We determine that the effective bright limits for read-out streak photometry with XMM-OM are approximately 1.5 magnitudes brighter than the bright source limits for normal aperture photometry in full-frame images. This translates into bright-source limits in Vega magnitudes of UVW2=7.1, UVM2=8.0, UVW1=9.4, U=10.5, B=11.5, V=10.2 and White=12.5 for data taken early in the mission. The limits brighten by up to 0.2 magnitudes, depending on filter, over the course of the mission as the detector ages. The method is demonstrated by deriving UVW1 photometry for the symbiotic nova RR Telescopii, and the new photometry is used to constrain the e-folding time of its decaying UV emission. Using the read-out streak method, we obtain photometry for 50 per cent of the missing UV source measurements in version 2.1 of the XMM-Newton Serendipitous UV Source Survey (XMM-SUSS 2.1) catalogue.
[2]  oai:arXiv.org:1503.06276  [pdf] - 1095626
PSR J1930-1852: a pulsar in the widest known orbit around another neutron star
Comments: 8 pages, 6 figures
Submitted: 2015-03-21
In the summer of 2012, during a Pulsar Search Collaboratory workshop, two high-school students discovered J1930$-$1852, a pulsar in a double neutron star (DNS) system. Most DNS systems are characterized by short orbital periods, rapid spin periods and eccentric orbits. However, J1930$-$1852 has the longest spin period ($P_{\rm spin}\sim$185 ms) and orbital period ($P_{\rm b}\sim$45 days) yet measured among known, recycled pulsars in DNS systems, implying a shorter than average and/or inefficient recycling period before its companion went supernova. We measure the relativistic advance of periastron for J1930$-$1852, $\dot{\omega}=0.00078$(4) deg/yr, which implies a total mass (M$_{\rm{tot}}=2.59$(4) M$_{\odot}$) consistent with other DNS systems. The $2\sigma$ constraints on M$_{\rm{tot}}$ place limits on the pulsar and companion masses ($m_{\rm p}<1.32$ M$_{\odot}$ and $m_{\rm c}>1.30$ M$_{\odot}$ respectively). J1930$-$1852's spin and orbital parameters challenge current DNS population models and make J1930$-$1852 an important system for further investigation.
[3]  oai:arXiv.org:1501.02433  [pdf] - 986616
The Swift-UVOT ultraviolet and visible grism calibration
Comments: 27 pages, 31 figures; MNRAS accepted 23 February 2015
Submitted: 2015-01-11, last modified: 2015-02-23
We present the calibration of the Swift UVOT grisms, of which there are two, providing low-resolution field spectroscopy in the ultraviolet and optical bands respectively. The UV grism covers the range 1700-5000 Angstrom with a spectral resolution of 75 at 2600 Angstrom for source magnitudes of u=10-16 mag, while the visible grism covers the range 2850-6600 Angstrom with a spectral resolution of 100 at 4000 Angstrom for source magnitudes of b=12-17 mag. This calibration extends over all detector positions, for all modes used during operations. The wavelength accuracy (1-sigma) is 9 Angstrom in the UV grism clocked mode, 17 Angstrom in the UV grism nominal mode and 22 Angstrom in the visible grism. The range below 2740 Angstrom in the UV grism and 5200 Angstrom in the visible grism never suffers from overlapping by higher spectral orders. The flux calibration of the grisms includes a correction we developed for coincidence loss in the detector. The error in the coincidence loss correction is less than 20%. The position of the spectrum on the detector only affects the effective area (sensitivity) by a few percent in the nominal modes, but varies substantially in the clocked modes. The error in the effective area is from 9% in the UV grism clocked mode to 15% in the visible grism clocked mode .
[4]  oai:arXiv.org:1309.4816  [pdf] - 1179345
The use and calibration of read-out streaks to increase the dynamic range of the Swift Ultraviolet/Optical Telescope
Comments: 11 pages, accepted for publication in MNRAS. Code available from the calibration link at http://www.mssl.ucl.ac.uk/www_astro/uvot
Submitted: 2013-09-18
The dynamic range of photon counting micro-channel-plate (MCP) intensified charged-coupled device (CCD) instruments such as the Swift Ultraviolet/Optical Telescope (UVOT) and the XMM-Newton Optical Monitor (XMM-OM) is limited at the bright end by coincidence loss, the superposition of multiple photons in the individual frames recorded by the CCD. Photons which arrive during the brief period in which the image frame is transferred for read out of the CCD are displaced in the transfer direction in the recorded images. For sufficiently bright sources, these displaced counts form read-out streaks. Using UVOT observations of Tycho-2 stars, we investigate the use of these read-out streaks to obtain photometry for sources which are too bright (and hence have too much coincidence loss) for normal aperture photometry to be reliable. For read-out-streak photometry, the bright-source limiting factor is coincidence loss within the MCPs rather than the CCD. We find that photometric measurements can be obtained for stars up to 2.4 magnitudes brighter than the usual full-frame coincidence-loss limit by using the read-out streaks. The resulting bright-limit Vega magnitudes in the UVOT passbands are UVW2=8.80, UVM2=8.27, UVW1=8.86, u=9.76, b=10.53, v=9.31 and White=11.71; these limits are independent of the windowing mode of the camera. We find that a photometric precision of 0.1 mag can be achieved through read-out streak measurements. A suitable method for the measurement of read-out streaks is described and all necessary calibration factors are given.
[5]  oai:arXiv.org:1004.2448  [pdf] - 222203
Paper II: Calibration of the Swift ultraviolet/optical telescope
Comments: Accepted for publication in MNRAS. 15 pages, 21 figures, 4 tables
Submitted: 2010-04-14
The Ultraviolet/Optical Telescope (UVOT) is one of three instruments onboard the Swift observatory. The photometric calibration has been published, and this paper follows up with details on other aspects of the calibration including a measurement of the point spread function with an assessment of the orbital variation and the effect on photometry. A correction for large scale variations in sensitivity over the field of view is described, as well as a model of the coincidence loss which is used to assess the coincidence correction in extended regions. We have provided a correction for the detector distortion and measured the resulting internal astrometric accuracy of the UVOT, also giving the absolute accuracy with respect to the International Celestial Reference System. We have compiled statistics on the background count rates, and discuss the sources of the background, including instrumental scattered light. In each case we describe any impact on UVOT measurements, whether any correction is applied in the standard pipeline data processing or whether further steps are recommended.
[6]  oai:arXiv.org:0812.2943  [pdf] - 19546
Swift-UVOT captures the earliest ultraviolet spectrum of a Gamma Ray Burst
Comments: 4 pages, 4 figures, accepted by MNRAS letters
Submitted: 2008-12-15, last modified: 2009-01-28
We present the earliest ever ultraviolet spectrum of a gamma-ray burst (GRB) as observed with the Swift-UVOT. The GRB 081203A spectrum was observed for 50 seconds with the UV grism starting 251 seconds after the Swift-BAT trigger when the GRB was of u ~13.4 mag and still rising to its peak optical brightness. The UV grism spectrum shows a damped Ly-alpha line, Ly-beta, and the Lyman continuum break at a redshift z = 2.05 +/- 0.01. A model fit to the Lyman absorption implies log N(HI) = 22.0 +/- 0.2 cm-2, which is typical for GRB host galaxies with damped Ly-alpha absorbers. This observation of GRB 081203A demonstrates that for GRBs brighter than v ~14 mag and with 0.5 < z < 3.5 the UVOT will be able to provide redshifts, and probe for damped Ly-alpha absorbers within 4-6 minutes from the time of the Swift-BAT trigger.
[7]  oai:arXiv.org:0708.2259  [pdf] - 254895
Photometric Calibration of the Swift Ultraviolet/Optical Telescope
Comments: Minor improvements after referees report. Accepted for publication in MNRAS
Submitted: 2007-08-16, last modified: 2007-11-09
We present the photometric calibration of the Swift UltraViolet/Optical Telescope (UVOT) which includes: optimum photometric and background apertures, effective area curves, colour transformations, conversion factors for count rates to flux, and the photometric zero points (which are accurate to better than 4 per cent) for each of the seven UVOT broadband filters. The calibration was performed with observations of standard stars and standard star fields that represent a wide range of spectral star types. The calibration results include the position dependent uniformity, and instrument response over the 1600-8000A operational range. Because the UVOT is a photon counting instrument, we also discuss the effect of coincidence loss on the calibration results. We provide practical guidelines for using the calibration in UVOT data analysis. The results presented here supersede previous calibration results.
[8]  oai:arXiv.org:astro-ph/0507413  [pdf] - 386220
The Swift Ultra-Violet/Optical Telescope
Comments: 55 Pages, 28 Figures, To be published in Space Science Reviews
Submitted: 2005-07-18
The UV/Optical Telescope (UVOT) is one of three instruments flying aboard the Swift Gamma-ray Observatory. It is designed to capture the early (approximately 1 minute) UV and optical photons from the afterglow of gamma-ray bursts in the 170-600 nm band as well as long term observations of these afterglows. This is accomplished through the use of UV and optical broadband filters and grisms. The UVOT has a modified Ritchey-Chretien design with micro-channel plate intensified charged-coupled device detectors that record the arrival time of individual photons and provide sub-arcsecond positioning of sources. We discuss some of the science to be pursued by the UVOT and the overall design of the instrument.
[9]  oai:arXiv.org:astro-ph/0011216  [pdf] - 253440
The XMM-Newton Optical/UV Monitor Telescope
Comments: Accepted by A&A for publication in the Special Issue on 1st science with XMM Newton, 9 pages
Submitted: 2000-11-10
The XMM-OM instrument extends the spectral coverage of the XMM-Newton observatory into the ultraviolet and optical range. It provides imaging and time-resolved data on targets simultaneously with observations in the EPIC and RGS. It also has the ability to track stars in its field of view, thus providing an improved post-facto aspect solution for the spacecraft. An overview of the XMM-OM and its operation is given, together with current information on the performance of the instrument.