sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Carpentier, E. Aller

Normalized to: Carpentier, E.

2 article(s) in total. 7 co-authors, from 1 to 2 common article(s). Median position in authors list is 3,0.

[1]  oai:arXiv.org:1203.4931  [pdf] - 1117467
Speckle Temporal Stability in eXtreme Adaptive Optics Coronagraphic Images
Comments: A&A accepted
Submitted: 2012-03-22
The major noise source limiting high-contrast imaging is due to the presence of quasi-static speckles. Speckle noise originates from wavefront errors caused by various independent sources, and it evolves on different timescales pending to their nature. An understanding of quasi-static speckles originating from instrumental errors is paramount for the search of faint stellar companions. Instrumental speckles average to a fixed pattern, which can be calibrated to a certain extent, but their temporal evolution ultimately limit this possibility. This study focuses on the laboratory evidence and characterization of the quasi-static pinned speckle phenomenon. Specifically, we examine the coherent amplification of the static speckle contribution to the noise variance in the scientific image, through its interaction with quasi-static speckles. The analysis of a time series of adaptively corrected, coronagraphic images recorded in the laboratory enables the characterization of the temporal stability of the residual speckle pattern in both direct and differential coronagraphic images. We estimate that spoiled and fast-evolving quasi-static speckles present in the system at the angstrom/nanometer level are affecting the stability of the static speckle noise in the final image after the coronagraph. The temporal evolution of the quasi-static wavefront error exhibits linear power law, which can be used in first order to model quasi-static speckle evolution in high-contrast imaging instruments.
[2]  oai:arXiv.org:0810.5678  [pdf] - 18059
Design, analysis and test of a microdots apodizer for the Apodized Pupil Lyot Coronagraph
Comments: A&A accepted, 8 pages
Submitted: 2008-10-31
Coronagraphic techniques are required to detect exoplanets with future Extremely Large Telescopes. One concept, the Apodized Pupil Lyot Coronagraph (APLC), is combining an apodizer in the entrance aperture and a Lyot opaque mask in the focal plane. This paper presents the manufacturing and tests of a microdots apodizer optimized for the near IR. The intent of this work is to demonstrate the feasibility and performance of binary apodizers for the APLC. This study is also relevant for any coronagraph using amplitude pupil apodization. A binary apodizer has been designed using a halftone dot process, where the binary array of pixels with either 0% or 100% transmission is calculated to fit the required continuous transmission, i.e. local transmission control is obtained by varying the relative density of the opaque and transparent pixels. An error diffusion algorithm was used to optimize the distribution of pixels that best approximates the required field transmission. The prototype was tested with a coronagraphic setup in the near IR. The transmission profile of the prototype agrees with the theoretical shape within 3% and is achromatic. The observed apodized and coronagraphic images are consistent with theory. However, binary apodizers introduce high frequency noise that is a function of the pixel size. Numerical simulations were used to specify pixel size in order to minimize this effect, and validated by experiment. This paper demonstrates that binary apodizers are well suited for being used in high contrast imaging coronagraphs. The correct choice of pixel size is important and must be adressed considering the scientific field of view.