sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Carelli, G.

Normalized to: Carelli, G.

3 article(s) in total. 23 co-authors, from 1 to 3 common article(s). Median position in authors list is 8,0.

[1]  oai:arXiv.org:2003.11819  [pdf] - 2070577
An underground Sagnac gyroscope with sub-prad/s rotation rate sensitivity: toward General Relativity tests on Earth
Comments: 7 pages, 5 figures
Submitted: 2020-03-26
Measuring in a single location on Earth its angular rotation rate with respect to the celestial frame, with a sensitivity enabling access to the tiny Lense-Thirring effect is an extremely challenging task. GINGERINO is a large frame ring laser gyroscope, operating free running and unattended inside the underground laboratory of the Gran Sasso, Italy. The main geodetic signals, i.e., Annual and Chandler wobbles, daily polar motion and Length of the Day, are recovered from GINGERINO data using standard linear regression methods, demonstrating a sensitivity better than 1 prad/s, therefore close to the requirements for an Earth-based Lense-Thirring test.
[2]  oai:arXiv.org:1906.11338  [pdf] - 1995428
Identification and correction of Sagnac frequency variations: an implementation for the GINGERINO data analysis
Comments: 7 pages and 6 figure
Submitted: 2019-06-26, last modified: 2019-11-08
Ring laser gyroscopes are top sensitivity inertial sensors used in the measurement of angular rotation rates. It is well known that the response of such remarkable instruments can in principle access the very low frequency band, but the occurrence of nonlinear effects in the laser dynamics imposes severe limitations in terms of sensitivity and stability. We report here general relationships aimed at evaluating corrections able to effectively account for nonlinear laser dynamics. The so-derived corrections are applied to analyse thirty days of continuous operation of the large area ring laser gyroscope GINGERINO leading to duly reconstruct the Sagnac frequency $\omega_S$. The analysis shows that, on the average, the evaluated corrections affect the measurement of the Earth rotation rate $\Omega_E$ at the level of 1 part in $1.5\times10^{3}$. Among the identified corrections, the null shift term $\omega_{NS}$ is the dominant one. It turns out proportional to the optical losses $\mu$ of the ring cavity, which are changing in time at the level of $10\%$ within the considered period of thirty days. The time behaviour is reconstructed based on available signals (interferogram and mono-beam intensities), and the Allan deviation of the estimated $\Omega_E$ shows a remarkable long term stability, leading to a sensitivity better than $10^{-10}$rad/s with more than $10$s of integration time, and approaching $(8.5\pm 0.5)\times 10^{-12}$rad/s with $4.5\times10^{5}$s of integration time.
[3]  oai:arXiv.org:1412.6901  [pdf] - 911612
A ring-lasers array for fundamental physics
Comments: 11 pages, in Comptes Rendus Physique, Special Issue "The Sagnac effect: 100 years later"
Submitted: 2014-12-22
After reviewing the importance of light as a probe for testing the structure of space-time, we describe the GINGER project. GINGER will be a three-dimensional array of large size ring-lasers able to measure the de Sitter and Lense-Thirring effects. The instrument will be located at the underground laboratory of GranSasso, in Italy. We describe the preliminary actions and measurements already under way and present the full road map to GINGER. The intermediate apparatuses GP2 and GINGERino are described. GINGER is expected to be fully operating in few years.