Normalized to: Cardani, L.
[1]
oai:arXiv.org:1606.04565 [pdf] - 1579984
High sensitivity phonon-mediated kinetic inductance detector with
combined amplitude and phase read-out
Bellini, F.;
Cardani, L.;
Casali, N.;
Castellano, M. G.;
Colantoni, I.;
Cosmelli, C.;
Cruciani, A.;
D'Addabbo, A.;
Di Domizio, S.;
Martinez, M.;
Tomei, C.;
Vignati, M.
Submitted: 2016-06-14, last modified: 2016-12-14
The development of wide-area cryogenic light detectors with good energy
resolution is one of the priorities of next generation bolometric experiments
searching for rare interactions, as the simultaneous read-out of the light and
heat signals enables background suppression through particle identification.
Among the proposed technological approaches for the phonon sensor, the
naturally-multiplexed Kinetic Inductance Detectors (KIDs) stand out for their
excellent intrinsic energy resolution and reproducibility. To satisfy the large
surface requirement (several cm$^2$) KIDs are deposited on an insulating
substrate that converts the impinging photons into phonons. A fraction of
phonons is absorbed by the KID, producing a signal proportional to the energy
of the original photons. The potential of this technique was proved by the
CALDER project, that reached a baseline resolution of 154$\pm$7 eV RMS by
sampling a 2$\times$2 cm$^2$ Silicon substrate with 4 Aluminum KIDs. In this
paper we present a prototype of Aluminum KID with improved geometry and quality
factor. The design improvement, as well as the combined analysis of amplitude
and phase signals, allowed to reach a baseline resolution of 82$\pm$4 eV by
sampling the same substrate with a single Aluminum KID.
[2]
oai:arXiv.org:1604.03314 [pdf] - 1389056
New application of superconductors: high sensitivity cryogenic light
detectors
Cardani, L.;
Bellini, F.;
Casali, N.;
Casellano, M. G.;
Colantoni, I.;
Coppolecchia, A.;
Cosmelli, C.;
Cruciani, A.;
D'Addabbo, A.;
Di Domizio, S.;
Martinez, M.;
Tomei, C.;
Vignati, M.
Submitted: 2016-04-12
In this paper we describe the current status of the CALDER project, which is
developing ultra-sensitive light detectors based on superconductors for
cryogenic applications. When we apply an AC current to a superconductor, the
Cooper pairs oscillate and acquire kinetic inductance, that can be measured by
inserting the superconductor in a LC circuit with high merit factor.
Interactions in the superconductor can break the Cooper pairs, causing sizable
variations in the kinetic inductance and, thus, in the response of the LC
circuit. The continuous monitoring of the amplitude and frequency modulation
allows to reconstruct the incident energy with excellent sensitivity. This
concept is at the basis of Kinetic Inductance Detectors (KIDs), that are
characterized by natural aptitude to multiplexed read-out (several sensors can
be tuned to different resonant frequencies and coupled to the same line),
resolution of few eV, stable behavior over a wide temperature range, and ease
in fabrication. We present the results obtained by the CALDER collaboration
with 2x2 cm2 substrates sampled by 1 or 4 Aluminum KIDs. We show that the
performances of the first prototypes are already competitive with those of
other commonly used light detectors, and we discuss the strategies for a
further improvement.
[3]
oai:arXiv.org:1209.2519 [pdf] - 621874
The low energy spectrum of TeO2 bolometers: results and dark matter
perspectives for the CUORE-0 and CUORE experiments
Alessandria, F.;
Ardito, R.;
Artusa, D. R.;
Avignone, F. T.;
Azzolini, O.;
Balata, M.;
Banks, T. I.;
Bari, G.;
Beeman, J.;
Bellini, F.;
Bersani, A.;
Biassoni, M.;
Bloxham, T.;
Brofferio, C.;
Bucci, C.;
Cai, X. Z.;
Canonica, L.;
Capelli, S.;
Carbone, L.;
Cardani, L.;
Carrettoni, M.;
Casali, N.;
Chott, N.;
Clemenza, M.;
Cosmelli, C.;
Cremonesi, O.;
Creswick, R. J.;
Dafinei, I.;
Dally, A.;
Datskov, V.;
De Biasi, A.;
Decowski, M. P.;
Deninno, M. M.;
Di Domizio, S.;
di Vacri, M. L.;
Ejzak, L.;
Faccini, R.;
Fang, D. Q.;
Farach, H. A.;
Ferri, E.;
Ferroni, F.;
Fiorini, E.;
Franceschi, M. A.;
Freedman, S. J.;
Frossati, G.;
Fujikawa, B. K.;
Giachero, A.;
Gironi, L.;
Giuliani, A.;
Goett, J. J.;
Gorla, P.;
Gotti, C.;
Guardincerri, E.;
Gutierrez, T. D.;
Haller, E. E.;
Han, K.;
Heeger, K. M.;
Huang, H. Z.;
Kadel, R.;
Kazkaz, K.;
Keppel, G.;
Kogler, L.;
Kolomensky, Yu. G.;
Lenz, D.;
Li, Y. L.;
Ligi, C.;
Liu, X.;
Ma, Y. G.;
Maiano, C.;
Maino, M.;
Martinez, M.;
Maruyama, R. H.;
Moggi, N.;
Morganti, S.;
Napolitano, T.;
Newman, S.;
Nisi, S.;
Nones, C.;
Norman, E. B.;
Nucciotti, A.;
Orio, F.;
Orlandi, D.;
Ouellet, J. L.;
Pallavicini, M.;
Palmieri, V.;
Pattavina, L.;
Pavan, M.;
Pedretti, M.;
Pessina, G.;
Pirro, S.;
Previtali, E.;
Rampazzo, V.;
Rimondi, F.;
Rosenfeld, C.;
Rusconi, C.;
Sangiorgio, S.;
Scielzo, N. D.;
Sisti, M.;
Smith, A. R.;
Stivanello, F.;
Taffarello, L.;
Tenconi, M.;
Tian, W. D.;
Tomei, C.;
Trentalange, S.;
Ventura, G.;
Vignati, M.;
Wang, B. S.;
Wang, H. W.;
Whitten, C. A.;
Wise, y T.;
Woodcraft, A.;
Zanotti, L.;
Zarra, C.;
Zhu, B. X.;
Zucchelli, S.
Submitted: 2012-09-12, last modified: 2013-02-01
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three
of them we were able to set the energy threshold around 3 keV using a new
analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3
keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak
is presently unknown, but its presence is confirmed by a reanalysis of 62.7
kg.days of data from the finished CUORICINO experiment. Finally, we report the
expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers)
experiments to a WIMP annual modulation signal.