Carabe-Lopez, J.
Normalized to: Carabe-Lopez, J.
2 article(s) in total. 52 co-authors, from 1 to 2 common article(s). Median position in authors list is 5,5.
[1]
oai:arXiv.org:1810.06703 [pdf] - 1875231
A Design for an Electromagnetic Filter for Precision Energy Measurements
at the Tritium Endpoint
Betti, M. G.;
Biasotti, M.;
Bosca, A.;
Calle, F.;
Carabe-Lopez, J.;
Cavoto, G.;
Chang, C.;
Chung, W.;
Cocco, A. G.;
Colijn, A. P.;
Conrad, J.;
D'Ambrosio, N.;
de Salas, P. F.;
Faverzani, M.;
Ferella, A.;
Ferri, E.;
Garcia-Abia, P.;
Gomez-Tejedor, G. Garcia;
Gariazzo, S.;
Gatti, F.;
Gentile, C.;
Giachero, A.;
Gudmundsson, J.;
Hochberg, Y.;
Kahn, Y.;
Lisanti, M.;
Mancini-Terracciano, C.;
Mangano, G.;
Marcucci, L. E.;
Mariani, C.;
Martinez, J.;
Messina, M.;
Molinero-Vela, A.;
Monticone, E.;
Nucciotti, A.;
Pandolfi, F.;
Pastor, S.;
Pedros, J.;
Heros, C. Perez de los;
Pisanti, O.;
Polosa, A.;
Puiu, A.;
Raitses, Y.;
Rajteri, M.;
Rossi, N.;
Santorelli, R.;
Schaeffner, K.;
Strid, C. F.;
Tully, C. G.;
Zhao, F.;
Zurek, K. M.
Submitted: 2018-10-15
We present a detailed description of the electromagnetic filter for the
PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB).
Starting with an initial estimate for the orbital magnetic moment, the
higher-order drift process of ExB is configured to balance the gradient-B drift
motion of the electron in such a way as to guide the trajectory into the
standing voltage potential along the mid-plane of the filter. As a function of
drift distance along the length of the filter, the filter zooms in with
exponentially increasing precision on the transverse velocity component of the
electron kinetic energy. This yields a linear dimension for the total filter
length that is exceptionally compact compared to previous techniques for
electromagnetic filtering. The parallel velocity component of the electron
kinetic energy oscillates in an electrostatic harmonic trap as the electron
drifts along the length of the filter. An analysis of the phase-space volume
conservation validates the expected behavior of the filter from the adiabatic
invariance of the orbital magnetic moment and energy conservation following
Liouville's theorem for Hamiltonian systems.
[2]
oai:arXiv.org:1808.01892 [pdf] - 1728123
PTOLEMY: A Proposal for Thermal Relic Detection of Massive Neutrinos and
Directional Detection of MeV Dark Matter
Baracchini, E.;
Betti, M. G.;
Biasotti, M.;
Bosca, A.;
Calle, F.;
Carabe-Lopez, J.;
Cavoto, G.;
Chang, C.;
Cocco, A. G.;
Colijn, A. P.;
Conrad, J.;
D'Ambrosio, N.;
de Salas, P. F.;
Faverzani, M.;
Ferella, A.;
Ferri, E.;
Garcia-Abia, P.;
Gomez-Tejedor, G. Garcia;
Gariazzo, S.;
Gatti, F.;
Gentile, C.;
Giachero, A.;
Gudmundsson, J.;
Hochberg, Y.;
Kahn, Y.;
Lisanti, M.;
Mancini-Terracciano, C.;
Mangano, G.;
Marcucci, L. E.;
Mariani, C.;
Martinez, J.;
Mazzitelli, G.;
Messina, M.;
Molinero-Vela, A.;
Monticone, E.;
Nucciotti, A.;
Pandolfi, F.;
Pastor, S.;
Pedros, J.;
Heros, C. Perez de los;
Pisanti, O.;
Polosa, A.;
Puiu, A.;
Rajteri, M.;
Santorelli, R.;
Schaeffner, K.;
Tully, C. G.;
Raitses, Y.;
Rossi, N.;
Zhao, F.;
Zurek, K. M.
Submitted: 2018-08-06
We propose to achieve the proof-of-principle of the PTOLEMY project to
directly detect the Cosmic Neutrino Background (CNB). Each of the technological
challenges described in [1,2] will be targeted and hopefully solved by the use
of the latest experimental developments and profiting from the low background
environment provided by the LNGS underground site. The first phase will focus
on the graphene technology for a tritium target and the demonstration of TES
microcalorimetry with an energy resolution of better than 0.05 eV for low
energy electrons. These technologies will be evaluated using the PTOLEMY
prototype, proposed for underground installation, using precision HV controls
to step down the kinematic energy of endpoint electrons to match the
calorimeter dynamic range and rate capabilities. The second phase will produce
a novel implementation of the EM filter that is scalable to the full target
size and which demonstrates intrinsic triggering capability for selecting
endpoint electrons. Concurrent with the CNB program, we plan to exploit and
develop the unique properties of graphene to implement an intermediate program
for direct directional detection of MeV dark matter [3,4]. This program will
evaluate the radio-purity and scalability of the graphene fabrication process
with the goal of using recently identified ultra-high radio-purity CO2 sources.
The direct detection of the CNB is a snapshot of early universe dynamics
recorded by the thermal relic neutrino yield taken at a time that predates the
epochs of Big Bang Nucleosynthesis, the Cosmic Microwave Background and the
recession of galaxies (Hubble Expansion). Big Bang neutrinos are believed to
have a central role in the evolution of the Universe and a direct measurement
with PTOLEMY will unequivocally establish the extent to which these predictions
match present-day neutrino densities.