oai:arXiv.org:1812.06972 [pdf] - 1800071
Sample clock frequency offset (SCFO) Resolution Team 3 (RT-3)
investigation
Submitted: 2018-12-18
This Resolution Team 3 (RT-3) report contains the results of the
investigation of key aspects of the proposed Sample Clock Frequency Offset
(SCFO) scheme for the Mid SKA1 telescope. This is a scheme, first proposed by
one author (Carlson) at a meeting at the SKAO 25-Jan-2013, to digitize the
analog signal at each antenna at a slightly different sample rate and transmit
the data to the CSP Mid.CBF for subsequent digital re-sampling to a common
sample clock frequency before channelization, correlation, and beamforming. The
primary purpose for doing this is to cause de-correlation of sample
clock-related self-interference to be able to improve correlated and beamformed
signal quality. This report includes an investigation of the efficacy of the
method, investigation of its implementation by SADT, DISH, and CSP,
presentation of further supporting modeling results augmenting the original
modeling work, a note on expansion to SKA-2, as well as possible draw-backs and
concerns. Finally, there are potential additional benefits in signal quality in
implementing the SCFO scheme, in particular de-correlation of aliased RFI
(particularly for Nyquist Zone-2 digitized signals) as well as relaxation of
signal-chain anti-aliasing filters transition band roll-off and reject band
attenuation prior to digitization in the antenna.
[2]
oai:arXiv.org:1408.4406 [pdf] - 1216393
NFIRAOS First Facility AO System for the Thirty Meter Telescope
Herriot, Glen;
Andersen, David;
Atwood, Jenny;
Boyer, Corinne;
Byrnes, Peter;
Caputa, Kris;
Ellerbroek, Brent;
Gilles, Luc;
Hill, Alexis;
Ljusic, Zoran;
Pazder, John;
Rosensteiner, Matthias;
Smith, Malcolm;
Spano, Paolo;
Szeto, Kei;
Véran, Jean-Pierre;
Wevers, Ivan;
Wang, Lianqi;
Wooff, Robert
Submitted: 2014-08-19
NFIRAOS, the Thirty Meter Telescope's first adaptive optics system is an
order 60x60 Multi-Conjugate AO system with two deformable mirrors. Although
most observing will use 6 laser guide stars, it also has an NGS-only mode.
Uniquely, NFIRAOS is cooled to -30 C to reduce thermal background. NFIRAOS
delivers a 2-arcminute beam to three client instruments, and relies on up to
three IR WFSs in each instrument. We present recent work including: robust
automated acquisition on these IR WFSs; trade-off studies for a common-size of
deformable mirror; real-time computing architectures; simplified designs for
high-order NGS-mode wavefront sensing; modest upgrade concepts for