Normalized to: Cancelo, G.
[1]
oai:arXiv.org:2004.11378 [pdf] - 2083499
SENSEI: Direct-Detection Results on sub-GeV Dark Matter from a New
Skipper-CCD
Barak, Liron;
Bloch, Itay M.;
Cababie, Mariano;
Cancelo, Gustavo;
Chaplinsky, Luke;
Chierchie, Fernando;
Crisler, Michael;
Drlica-Wagner, Alex;
Essig, Rouven;
Estrada, Juan;
Etzion, Erez;
Moroni, Guillermo Fernandez;
Gift, Daniel;
Munagavalasa, Sravan;
Orly, Aviv;
Rodrigues, Dario;
Singal, Aman;
Haro, Miguel Sofo;
Stefanazzi, Leandro;
Tiffenberg, Javier;
Uemura, Sho;
Volansky, Tomer;
Yu, Tien-Tien
Submitted: 2020-04-23
We present the first direct-detection search for eV-to-GeV dark matter using
a new ~2-gram high-resistivity Skipper-CCD from a dedicated fabrication batch
that was optimized for dark-matter searches. Using 24 days of data acquired in
the MINOS cavern at the Fermi National Accelerator Laboratory, we measure the
lowest rates in silicon detectors of events containing one, two, three, or four
electrons, and achieve world-leading sensitivity for a large range of sub-GeV
dark matter masses. Data taken with different thicknesses of the detector
shield suggest a correlation between the rate of high-energy tracks and the
rate of single-electron events previously classified as "dark current." We
detail key characteristics of the new Skipper-CCDs, which augur well for the
planned construction of the ~100-gram SENSEI experiment at SNOLAB.
[2]
oai:arXiv.org:2004.07599 [pdf] - 2078813
Low Threshold Acquisition controller for Skipper CCDs
Cancelo, Gustavo;
Chavez, Claudio;
Chierchie, Fernando;
Estrada, Juan;
Moroni, Guillermo Fernandez;
Paolini, Eduardo Emilio;
Haro, Miguel Sofo;
Soto, Angel;
Stefanazzi, Leandro;
Tiffenberg, Javier;
Treptow, Ken;
Wilcer, Neal;
Zmuda, Ted
Submitted: 2020-04-16
The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been
a major technological breakthrough for sensing very weak ionizing particles.
The sensor allows to reach the ultimate sensitivity of silicon material as a
charge signal sensor by unambiguous determination of the charge signal
collected by each cell or pixel, even for single electron-hole pair ionization.
Extensive use of the technology was limited by the lack of specific equipment
to operate the sensor at the ultimate performance. In this work a simple,
single-board Skipper-CCD controller is presented, aimed for the operation of
the detector in high sensitivity scientific applications. The article describes
the main components and functionality of the Low Threshold Acquisition (LTA)
together with experimental results when connected to a Skipper-CCD sensor.
Measurements show unprecedented deep sub-electron noise of 0.039
e$^-_{rms}$/pix for 5000 pixel measurements.
[3]
oai:arXiv.org:1907.12628 [pdf] - 2076614
Constraints on Light Dark Matter Particles Interacting with Electrons
from DAMIC at SNOLAB
Aguilar-Arevalo, A.;
Amidei, D.;
Baxter, D.;
Cancelo, G.;
Vergara, B. A. Cervantes;
Chavarria, A. E.;
Darragh-Ford, E.;
Neto, J. R. T. de Mello;
D'Olivo, J. C.;
Estrada, J.;
Gaïor, R.;
Guardincerri, Y.;
Hossbach, T. W.;
Kilminster, B.;
Lawson, I.;
Lee, S. J.;
Letessier-Selvon, A.;
Matalon, A.;
Mello, V. B. B.;
Mitra, P.;
Mobarak, Y. S.;
Molina, J.;
Paul, S.;
Piers, A.;
Privitera, P.;
Ramanathan, K.;
Da Rocha, J.;
Settimo, M.;
Smida, R.;
Thomas, R.;
Tiffenberg, J.;
Machado, D. Torres;
Vilar, R.;
Virto, A. L.
Submitted: 2019-07-29, last modified: 2020-04-08
We report direct-detection constraints on light dark matter particles
interacting with electrons. The results are based on a method that exploits the
extremely low levels of leakage current of the DAMIC detector at SNOLAB of
2-6$\times$10$^{-22}$ A cm$^{-2}$. We evaluate the charge distribution of
pixels that collect $<10~\rm{e^-}$ for contributions beyond the leakage current
that may be attributed to dark matter interactions. Constraints are placed on
so-far unexplored parameter space for dark matter masses between 0.6 and 100
MeV$c^{-2}$. We also present new constraints on hidden-photon dark matter with
masses in the range $1.2$-$30$ eV$c^{-2}$.
[4]
oai:arXiv.org:2004.04266 [pdf] - 2077337
Interplay between phonon downconversion efficiency, density of states at
Fermi energy, and intrinsic energy resolution for microwave kinectic
inductance detectors
Submitted: 2020-04-06
Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a
powerful new tool for single photon detection. These highly multiplexed
superconducting devices give timing and energy measurement for every detected
photon. However, the full potential of MKID single photon spectroscopy has not
been reached , the achieved energy resolution is lower than expected from first
principles. Here, we study the efficiency in the phonon downconversion process
following the absorption of energetic photons in MKIDs. Assuming previously
published material properties, we measure an average downconversion efficiency
for three TiN resonators is $\eta$=0.14. We discuss how this efficiency can
impact the intrinsic energy resolution of MKID, and how any uncertainty in the
unknown density of electron states at the Fermi energy directly affects the
efficiency estimations.
[5]
oai:arXiv.org:1906.02200 [pdf] - 2000205
Exploring low-energy neutrino physics with the Coherent Neutrino Nucleus
Interaction Experiment (CONNIE)
Aguilar-Arevalo, Alexis;
Bertou, Xavier;
Bonifazi, Carla;
Cancelo, Gustavo;
Castañeda, Alejandro;
Vergara, Brenda Cervantes;
Chavez, Claudio;
D'Olivo, Juan C.;
Anjos, João C. dos;
Estrada, Juan;
Neto, Aldo R. Fernandes;
Moroni, Guillermo Fernandez;
Foguel, Ana;
Ford, Richard;
Cuevas, Juan Gonzalez;
Hernández, Pamela;
Hernandez, Susana;
Izraelevitch, Federico;
Kavner, Alexander R.;
Kilminster, Ben;
Kuk, Kevin;
Lima, H. P.;
Makler, Martin;
Molina, Jorge;
Mota, Philipe;
Nasteva, Irina;
Paolini, Eduardo E.;
Romero, Carlos;
Sarkis, Y.;
Haro, Miguel Sofo;
Souza, Iruatã M. S.;
Tiffenberg, Javier;
Wagner, Stefan
Submitted: 2019-06-05, last modified: 2019-10-10
The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) uses low-noise
fully depleted charge-coupled devices (CCDs) with the goal of measuring
low-energy recoils from coherent elastic scattering (CE$\nu$NS) of reactor
antineutrinos with silicon nuclei and testing nonstandard neutrino interactions
(NSI). We report here the first results of the detector array deployed in 2016,
considering an active mass 47.6 g (8 CCDs), which is operating at a distance of
30 m from the core of the Angra 2 nuclear reactor, with a thermal power of 3.8
GW. A search for neutrino events is performed by comparing data collected with
reactor on (2.1 kg-day) and reactor off (1.6 kg-day). The results show no
excess in the reactor-on data, reaching the world record sensitivity down to
recoil energies of about 1 keV (0.1 keV electron-equivalent). A 95% confidence
level limit for new physics is established at an event rate of 40 times the one
expected from the standard model at this energy scale. The results presented
here provide a new window to low-energy neutrino physics, allowing one to
explore for the first time the energies accessible through the low threshold of
CCDs. They will lead to new constrains on NSI from the CE$\nu$NS of
antineutrinos from nuclear reactors.
[6]
oai:arXiv.org:1803.10420 [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field
Spectrograph for High-Contrast Astronomy
Meeker, Seth R.;
Mazin, Benjamin A.;
Walter, Alex B.;
Strader, Paschal;
Fruitwala, Neelay;
Bockstiegel, Clint;
Szypryt, Paul;
Ulbricht, Gerhard;
Coiffard, Gregoire;
Bumble, Bruce;
Cancelo, Gustavo;
Zmuda, Ted;
Treptow, Ken;
Wilcer, Neal;
Collura, Giulia;
Dodkins, Rupert;
Lipartito, Isabel;
Zobrist, Nicholas;
Bottom, Michael;
Shelton, J. Chris;
Mawet, Dimitri;
van Eyken, Julian C.;
Vasisht, Gautam;
Serabyn, Eugene
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving
Superconducting Spectrophotometer), the first of several planned integral field
spectrographs to use optical/near-infrared Microwave Kinetic Inductance
Detectors (MKIDs) for high-contrast imaging. The photon counting and
simultaneous low-resolution spectroscopy provided by MKIDs will enable
real-time speckle control techniques and post-processing speckle suppression at
framerates capable of resolving the atmospheric speckles that currently limit
high-contrast imaging from the ground. DARKNESS is now operational behind the
PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at
Palomar Observatory. Here we describe the motivation, design, and
characterization of the instrument, early on-sky results, and future prospects.
[7]
oai:arXiv.org:1702.00873 [pdf] - 1581372
A measurement of the ionization efficiency of nuclear recoils in silicon
Izraelevitch, F.;
Amidei, D.;
Aprahamian, A.;
Arcos-Olalla, R.;
Cancelo, G.;
Casarella, C.;
Chavarria, A. E.;
Collon, P.;
Estrada, J.;
Moroni, G. Fernández;
Guardincerri, Y.;
Gutiérrez, G.;
Gyurjinyan, A.;
Kavner, A.;
Kilminster, B.;
Lathrop, A.;
Liao, J.;
Liu, Q.;
López, M.;
Molina, J.;
Privitera, P.;
Reyes, M. A.;
Scarpine, V.;
Siegl, K.;
Smith, M.;
Strauss, S.;
Tan, W.;
Tiffenberg, J.;
Villanueva, L.
Submitted: 2017-02-02, last modified: 2017-07-04
We have measured the ionization efficiency of silicon nuclear recoils with
kinetic energy between 1.8 and 20 keV. We bombarded a silicon-drift diode with
a neutron beam to perform an elastic-scattering experiment. A broad-energy
neutron spectrum was used and the nuclear recoil energy was reconstructed using
a measurement of the time of flight and scattering angle of the scattered
neutron. The overall trend of the results of this work is well described by the
theory of Lindhard et al. above 4 keV of recoil energy. Below this energy, the
presented data shows a deviation from the model. The data indicates a faster
drop than the theory prediction at low energies.
[8]
oai:arXiv.org:1611.03066 [pdf] - 1561044
First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter
with DAMIC at SNOLAB
Aguilar-Arevalo, A.;
Amidei, D.;
Bertou, X.;
Butner, M.;
Cancelo, G.;
Vázquez, A. Castañeda;
Vergara, B. A. Cervantes;
Chavarria, A. E.;
Chavez, C. R.;
Neto, J. R. T. de Mello;
D'Olivo, J. C.;
Estrada, J.;
Moroni, G. Fernandez;
Gaïor, R.;
Guardincerri, Y.;
Torres, K. P. Hernández;
Izraelevitch, F.;
Kavner, A.;
Kilminster, B.;
Lawson, I.;
Letessier-Selvon, A.;
Liao, J.;
Matalon, A.;
Mello, V. B. B.;
Molina, J.;
Privitera, P.;
Ramanathan, K.;
Sarkis, Y.;
Schwarz, T.;
Settimo, M.;
Haro, M. Sofo;
Thomas, R.;
Tiffenberg, J.;
Tiouchichine, E.;
Machado, D. Torres;
Trillaud, F.;
You, X.;
Zhou, J.
Submitted: 2016-11-09, last modified: 2017-04-11
We present direct detection constraints on the absorption of hidden-photon
dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC
experiment at SNOLAB. Under the assumption that the local dark matter is
entirely constituted of hidden photons, the sensitivity to the kinetic mixing
parameter $\kappa$ is competitive with constraints from solar emission,
reaching a minimum value of 2.2$\times$$10^{-14}$ at 17 eV$c^{-2}$. These
results are the most stringent direct detection constraints on hidden-photon
dark matter in the galactic halo with masses 3-12 eV$c^{-2}$ and the first
demonstration of direct experimental sensitivity to ionization signals $<$12 eV
from dark matter interactions.
[9]
oai:arXiv.org:1607.07410 [pdf] - 1511851
Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC
experiment at SNOLAB
Aguilar-Arevalo, A.;
Amidei, D.;
Bertou, X.;
Butner, M.;
Cancelo, G.;
Vázquez, A. Castañeda;
Vergara, B. A. Cervantes;
Chavarria, A. E.;
Chavez, C. R.;
Neto, J. R. T. de Mello;
D'Olivo, J. C.;
Estrada, J.;
Moroni, G. Fernandez;
Gaïor, R.;
Guandincerri, Y.;
Torres, K. P. Hernández;
Izraelevitch, F.;
Kavner, A.;
Kilminster, B.;
Lawson, I.;
Letessier-Selvon, A.;
Liao, J.;
Molina, J.;
Peña, J. R.;
Privitera, P.;
Ramanathan, K.;
Sarkis, Y.;
Schwarz, T.;
Sengul, C.;
Settimo, M.;
Haro, M. Sofo;
Thomas, R.;
Tiffenberg, J.;
Tiouchichine, E.;
Machado, D. Torres;
Trillaud, F.;
You, X.;
Zhou, J.
Submitted: 2016-07-25, last modified: 2016-11-09
We present results of a dark matter search performed with a 0.6 kg day
exposure of the DAMIC experiment at the SNOLAB underground laboratory. We
measure the energy spectrum of ionization events in the bulk silicon of
charge-coupled devices down to a signal of 60 eV electron equivalent. The data
are consistent with radiogenic backgrounds, and constraints on the
spin-independent WIMP-nucleon elastic-scattering cross section are accordingly
placed. A region of parameter space relevant to the potential signal from the
CDMS-II Si experiment is excluded using the same target for the first time.
This result obtained with a limited exposure demonstrates the potential to
explore the low-mass WIMP region (<10 GeV/$c^{2}$) of the upcoming DAMIC100, a
100 g detector currently being installed in SNOLAB.
[10]
oai:arXiv.org:1510.00044 [pdf] - 1323491
Status of the DAMIC direct dark matter search experiment
DAMIC Collaboration;
Aguilar-Arevalo, A.;
Amidei, D.;
Bertou, X.;
Boule, D.;
Butner, M.;
Cancelo, G.;
Vázquez, A. Castañeda;
Chavarría, A. E.;
Neto, J. R. T. de Melo;
Dixon, S.;
D'Olivo, J. C.;
Estrada, J.;
Moroni, G. Fernandez;
Torres, K. P. Hernández;
Izraelevitch, F.;
Kavner, A.;
Kilminster, B.;
Lawson, I.;
Liao, J.;
López, M.;
Molina, J.;
Moreno-Granados, G.;
Pena, J.;
Privitera, P.;
Sarkis, Y.;
Scarpine, V.;
Schwartz, T.;
Haro, M. Sofo;
Tiffenberg, J.;
Machado, D. Torres;
Trillaud, F.;
You, X.;
Zhou, J.
Submitted: 2015-09-30, last modified: 2015-12-08
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for
dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and
excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to
identify and suppress radioactive backgrounds, having an unrivaled sensitivity
to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction
of a 100 g detector, DAMIC100, currently being installed at SNOLAB. This
contribution discusses the installation progress, new calibration efforts near
the threshold, a preliminary result with 2014 data, and the prospects for
physics results after one year of data taking.
[11]
oai:arXiv.org:1510.02126 [pdf] - 1449866
The DAMIC dark matter experiment
Aguilar-Arevalo, A.;
Amidei, D.;
Bertou, X.;
Bole, D.;
Butner, M.;
Cancelo, G.;
Vázquez, A. Castañeda;
Chavarria, A. E.;
Neto, J. R. T. de Mello;
Dixon, S.;
D'Olivo, J. C.;
Estrada, J.;
Moroni, G. Fernandez;
Torres, K. P. Hernández;
Izraelevitch, F.;
Kavner, A.;
Kilminster, B.;
Lawson, I.;
Liao, J.;
López, M.;
Molina, J.;
Moreno-Granados, G.;
Pena, J.;
Privitera, P.;
Sarkis, Y.;
Scarpine, V.;
Schwarz, T.;
Haro, M. Sofo;
Tiffenberg, J.;
Machado, D. Torres;
Trillaud, F.;
You, X.;
Zhou, J.
Submitted: 2015-10-07
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific
grade CCDs to search for dark matter. The CCD's low electronic noise allows an
unprecedently low energy threshold of a few tens of eV that make it possible to
detect silicon recoils resulting from interactions of low mass WIMPs. In
addition the CCD's high spatial resolution and the excellent energy response
results in very effective background identification techniques. The experiment
has a unique sensitivity to dark matter particles with masses below 10
GeV/c$^2$. Previous results have demonstrated the potential of this technology,
motivating the construction of DAMIC100, a 100 grams silicon target detector
currently being installed at SNOLAB. In this contribution, the mode of
operation and unique imaging capabilities of the CCDs, and how they may be
exploited to characterize and suppress backgrounds will be discussed, as well
as physics results after one year of data taking.
[12]
oai:arXiv.org:1506.02562 [pdf] - 1505514
Measurement of radioactive contamination in the high-resistivity silicon
CCDs of the DAMIC experiment
Aguilar-Arevalo, A.;
Amidei, D.;
Bertou, X.;
Bole, D.;
Butner, M.;
Cancelo, G.;
Vázquez, A. Castañeda;
Chavarria, A. E.;
Neto, J. R. T. de Mello;
Dixon, S.;
D'Olivo, J. C.;
Estrada, J.;
Moroni, G. Fernandez;
Torres, K. P. Hernández;
Izraelevitch, F.;
Kavner, A.;
Kilminster, B.;
Lawson, I.;
Liao, J.;
López, M.;
Molina, J.;
Moreno-Granados, G.;
Pena, J.;
Privitera, P.;
Sarkis, Y.;
Scarpine, V.;
Schwarz, T.;
Haro, M. Sofo;
Tiffenberg, J.;
Machado, D. Torres;
Trillaud, F.;
You, X.;
Zhou, J.
Submitted: 2015-06-08, last modified: 2015-07-09
We present measurements of radioactive contamination in the high-resistivity
silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search
for dark matter particles. Novel analysis methods, which exploit the unique
spatial resolution of CCDs, were developed to identify $\alpha$ and $\beta$
particles. Uranium and thorium contamination in the CCD bulk was measured
through $\alpha$ spectroscopy, with an upper limit on the $^{238}$U
($^{232}$Th) decay rate of 5 (15) kg$^{-1}$ d$^{-1}$ at 95% CL. We also
searched for pairs of spatially correlated electron tracks separated in time by
up to tens of days, as expected from $^{32}$Si-$^{32}$P or
$^{210}$Pb-$^{210}$Bi sequences of $\beta$ decays. The decay rate of $^{32}$Si
was found to be $80^{+110}_{-65}$ kg$^{-1}$ d$^{-1}$ (95% CI). An upper limit
of $\sim$35 kg$^{-1}$ d$^{-1}$ (95% CL) on the $^{210}$Pb decay rate was
obtained independently by $\alpha$ spectroscopy and the $\beta$ decay sequence
search. These levels of radioactive contamination are sufficiently low for the
successful operation of CCDs in the forthcoming 100 g DAMIC detector.
[13]
oai:arXiv.org:1405.5761 [pdf] - 1209685
Charge Coupled Devices for detection of coherent neutrino-nucleus
scattering
Submitted: 2014-05-22, last modified: 2014-09-19
This article details the potential for using Charge Coupled Devices (CCD) to
detect low-energy neutrinos through their coherent scattering with nuclei. The
detection of neutrinos through this standard model process has not been
accessible because of the small energy deposited in such interactions with the
detector nuclei. Typical particle detectors have thresholds of a few keV, and
most of the energy deposition expected from coherent scattering is well below
this level. The devices we discuss can be operated at a threshold of
approximately 30 eV, making them ideal for observing this signal. For example,
the number of coherent scattering events expected on a 52 gram CCD array
located next to a power nuclear reactor is estimated as approximately 626
events/year. The results of our study show that detection at a confidence level
of 99% can be reached within three months for this kind of detector array.
[14]
oai:arXiv.org:1407.0347 [pdf] - 845006
DAMIC at SNOLAB
Chavarria, Alvaro;
Tiffenberg, Javier;
Aguilar-Arevalo, Alexis;
Amidei, Dan;
Bertou, Xavier;
Cancelo, Gustavo;
D'Olivo, Juan Carlos;
Estrada, Juan;
Moroni, Guillermo Fernandez;
Izraelevitch, Federico;
Kilminster, Ben;
Langisetty, Yashmanth;
Liao, Junhui;
Molina, Jorge;
Privitera, Paolo;
Salazar, Carolina;
Sarkis, Youssef;
Scarpine, Vic;
Schwarz, Tom;
Haro, Miguel Sofo;
Trillaud, Frederic;
Zhou, Jing
Submitted: 2014-06-30
We introduce the fully-depleted charge-coupled device (CCD) as a particle
detector. We demonstrate its low energy threshold operation, capable of
detecting ionizing energy depositions in a single pixel down to 50 eVee. We
present results of energy calibrations from 0.3 keVee to 60 keVee, showing that
the CCD is a fully active detector with uniform energy response throughout the
silicon target, good resolution (Fano ~0.16), and remarkable linear response to
electron energy depositions. We show the capability of the CCD to localize the
depth of particle interactions within the silicon target. We discuss the mode
of operation and unique imaging capabilities of the CCD, and how they may be
exploited to characterize and suppress backgrounds. We present the first
results from the deployment of 250 um thick CCDs in SNOLAB, a prototype for the
upcoming DAMIC100. DAMIC100 will have a target mass of 0.1 kg and should be
able to directly test the CDMS-Si signal within a year of operation.
[15]
oai:arXiv.org:1310.6688 [pdf] - 737451
DAMIC: a novel dark matter experiment
The DAMIC Collaboration;
Aguilar-Arevalo, Alexis A.;
Bertou, Xavier;
Butner, Melissa J.;
Cancelo, Gustavo;
Chavarria, Alvaro;
D'Olivo, Juan Carlos;
Vigil, Juan Cruz Estrada;
Moroni, Guillermo Fernandez;
Izraelevitch, Federico;
Kilminster, Ben;
Lawson, Ian T.;
Marsal, Fernando;
Molina, Jorge;
Privitera, Paolo;
Schwarz, Tom;
Haro, Miguel Sofo;
Tiffenberg, Javier;
Trillaud, Frederic;
Zhou, Jing
Submitted: 2013-10-24
DAMIC (Dark Matter in CCDs) is a novel dark matter experiment that has unique
sensitivity to dark matter particles with masses below 10 GeV. Due to its low
electronic readout noise (R.M.S. ~3 e-) this instrument is able to reach a
detection threshold below 0.5 keV nuclear recoil energy, making the search for
dark matter particles with low masses possible. We report on early results and
experience gained from a detector that has been running at SNOLAB from Dec
2012. We also discuss the measured and expected backgrounds and present the
plan for future detectors to be installed in 2014.
[16]
oai:arXiv.org:1107.0925 [pdf] - 381106
Deep sub electron noise readout in CCD systems using digital filtering
techniques
Submitted: 2011-07-05
Scientific CCDs designed in thick high resistivity silicon (Si) are excellent
detectors for astronomy, high energy and nuclear physics, and instrumentation.
Many applications can benefit from CCDs ultra low noise readout systems. The
present work shows how sub electron noise CCD images can be achieved using
digital signal processing techniques. These techniques allow readout bandwidths
of up to 10 K pixels per second and keep the full CCD spatial resolution and
signal dynamic range.
[17]
oai:arXiv.org:1106.1839 [pdf] - 1077180
Achieving sub-electron readout noise in Skipper CCDs
Submitted: 2011-06-09, last modified: 2011-06-14
The readout noise for Charge-Coupled Devices (CCDs) has been the main
limitation when using these detectors for measuring small amplitude signals. A
readout system for a new scientific, low noise CCD is presented in this paper.
The Skipper CCD architecture, and its advantages for low noise applications are
discussed. A technique for obtaining sub-electron readout noise levels is
presented, and its noise and signal characteristics are derived. We demonstrate
a very low readout noise of $0.2e^{-}$ RMS. Also, we show the results using the
detector in a low-energy X-ray detection experiment.