Normalized to: Cabak, J.
[1]
oai:arXiv.org:1807.10356 [pdf] - 1751926
The Keck Cosmic Web Imager Integral Field Spectrograph
Morrissey, Patrick;
Matuszewski, Matuesz;
Martin, D. Christopher;
Neill, James D.;
Epps, Harland;
Fucik, Jason;
Weber, Bob;
Darvish, Behnam;
Adkins, Sean;
Allen, Steve;
Bartos, Randy;
Belicki, Justin;
Cabak, Jerry;
Callahan, Shawn;
Cowley, Dave;
Crabill, Marty;
Deich, Willian;
Delecroix, Alex;
Doppman, Greg;
Hilyard, David;
James, Ean;
Kaye, Steve;
Kokorowski, Michael;
Kwok, Shui;
Lanclos, Kyle;
Milner, Steve;
Moore, Anna;
O'Sullivan, Donal;
Parihar, Prachi;
Park, Sam;
Phillips, Andrew;
Rizzi, Luca;
Rockosi, Constance;
Rodriguez, Hector;
Salaun, Yves;
Seaman, Kirk;
Sheikh, David;
Weiss, Jason;
Zarzaca, Ray
Submitted: 2018-07-26
We report on the design and performance of the Keck Cosmic Web Imager (KCWI),
a general purpose optical integral field spectrograph that has been installed
at the Nasmyth port of the 10 m Keck II telescope on Mauna Kea, HI. The novel
design provides blue-optimized seeing-limited imaging from 350-560 nm with
configurable spectral resolution from 1000 - 20000 in a field of view up to
20"x33". Selectable volume phase holographic (VPH) gratings and high
performance dielectric, multilayer silver and enhanced aluminum coatings
provide end-to-end peak efficiency in excess of 45% while accommodating the
future addition of a red channel that will extend wavelength coverage to 1
micron. KCWI takes full advantage of the excellent seeing and dark sky above
Mauna Kea with an available nod-and-shuffle observing mode. The instrument is
optimized for observations of faint, diffuse objects such as the intergalactic
medium or cosmic web. In this paper, a detailed description of the instrument
design is provided with measured performance results from the laboratory test
program and ten nights of on-sky commissioning during the spring of 2017. The
KCWI team is lead by Caltech and JPL (project management, design and
implementation) in partnership with the University of California at Santa Cruz
(camera optical and mechanical design) and the W. M. Keck Observatory
(observatory interfaces).
[2]
oai:arXiv.org:1609.02060 [pdf] - 1531506
Detailed Design of a Deployable Tertiary Mirror for the Keck I Telescope
Prochaska, J. Xavier;
Ratliff, Chris;
Cabak, Jerry;
Tripsas, Alex;
Adkins, Sean;
Bolte, Michael;
Cowley, David;
Dahler, Mike;
Deich, Will;
Lewis, Hilton;
Nelson, Jerry;
Park, Sam;
Peck, Michael;
Phillips, Drew;
Pollard, Mike;
Randolph, Bill;
Sanford, Dale;
Ward, Jim;
Wold, Truman
Submitted: 2016-09-07
Motivated by the ever increasing pursuit of science with the transient sky
(dubbed Time Domain Astronomy or TDA), we are fabricating and will commission a
new deployable tertiary mirror for the Keck I telescope (K1DM3) at the W.M.
Keck Observatory. This paper presents the detailed design of K1DM3 with
emphasis on the opto-mechanics. This project has presented several design
challenges. Foremost are the competing requirements to avoid vignetting the
light path when retracted against a sufficiently rigid system for
high-precision and repeatable pointing. The design utilizes an actuated swing
arm to retract the mirror or deploy it into a kinematic coupling. The K1DM3
project has also required the design and development of custom connections to
provide power, communications, and compressed air to the system. This NSF-MRI
funded project is planned to be commissioned in Spring 2017.
[3]
oai:arXiv.org:1407.8207 [pdf] - 1216027
ShaneAO: wide science spectrum adaptive optics system for the Lick
Observatory
Gavel, Donald;
Kupke, Renate;
Dillon, Daren;
Norton, Andrew;
Ratliff, Chris;
Cabak, Jerry;
Phillips, Andrew;
Rockosi, Connie;
McGurk, Rosalie;
Srinath, Srikar;
Peck, Michael;
Deich, William;
Lanclos, Kyle;
Gates, John;
Saylor, Michael;
Ward, Jim;
Pfister, Terry
Submitted: 2014-07-30
A new high-order adaptive optics system is now being commissioned at the Lick
Observatory Shane 3-meter telescope in California. This system uses a high
return efficiency sodium beacon and a combination of low and high-order
deformable mirrors to achieve diffraction-limited imaging over a wide spectrum
of infrared science wavelengths covering 0.8 to 2.2 microns. We present the
design performance goals and the first on-sky test results. We discuss several
innovations that make this system a pathfinder for next generation AO systems.
These include a unique woofer-tweeter control that provides full dynamic range
correction from tip/tilt to 16 cycles, variable pupil sampling wavefront
sensor, new enhanced silver coatings developed at UC Observatories that improve
science and LGS throughput, and tight mechanical rigidity that enables a
multi-hour diffraction- limited exposure in LGS mode for faint object
spectroscopy science.
[4]
oai:arXiv.org:1407.8209 [pdf] - 1216029
Opto-Mechanical Design of ShaneAO: the Adaptive Optics System for the
3-meter Shane Telescope
Ratliff, Christopher;
Cabak, Jerry;
Gavel, Donald;
Kupke, Renate;
Dillon, Daren;
Gates, Elinor;
Deich, William;
Ward, Jim;
Cowley, David;
Pfister, Terry;
Saylor, Mike
Submitted: 2014-07-30
A Cassegrain mounted adaptive optics instrument presents unique challenges
for opto-mechanical design. The flexure and temperature tolerances for
stability are tighter than those of seeing limited instruments. This criteria
requires particular attention to material properties and mounting techniques.
This paper addresses the mechanical designs developed to meet the optical
functional requirements. One of the key considerations was to have
gravitational deformations, which vary with telescope orientation, stay within
the optical error budget, or ensure that we can compensate with a steering
mirror by maintaining predictable elastic behavior. Here we look at several
cases where deformation is predicted with finite element analysis and Hertzian
deformation analysis and also tested. Techniques used to address thermal
deformation compensation without the use of low CTE materials will also be
discussed.
[5]
oai:arXiv.org:1402.6684 [pdf] - 1203597
APF - The Lick Observatory Automated Planet Finder
Vogt, Steven S.;
Radovan, Matthew;
Kibrick, Robert;
Butler, R. Paul;
Alcott, Barry;
Allen, Steve;
Arriagada, Pamela;
Bolte, Mike;
Burt, Jennifer;
Cabak, Jerry;
Chloros, Kostas;
Cowley, David;
Deich, William;
Dupraw, Brian;
Earthman, Wayne;
Epps, Harland;
Faber, Sandra;
Fischer, Debra;
Gates, Elinor;
Hilyard, David;
Holden, Brad;
Johnston, Ken;
Keiser, Sandy;
Kanto, Dick;
Katsuki, Myra;
Laiterman, Lee;
Lanclos, Kyle;
Laughlin, Greg;
Lewis, Jeff;
Lockwood, Chris;
Lynam, Paul;
Marcy, Geoffrey;
McLean, Maureen;
Miller, Joe;
Misch, Tony;
Peck, Michael;
Pfister, Terry;
Phillips, Andrew;
Rivera, Eugenio;
Sandford, Dale;
Saylor, Mike;
Stover, Richard;
Thompson, Matthew;
Walp, Bernie;
Ward, James;
Wareham, John;
Wei, Mingzhi;
Wright, Chris
Submitted: 2014-02-26
The Automated Planet Finder (APF) is a facility purpose-built for the
discovery and characterization of extrasolar planets through high-cadence
Doppler velocimetry of the reflex barycentric accelerations of their host
stars. Located atop Mt. Hamilton, the APF facility consists of a 2.4-m
telescope and its Levy spectrometer, an optical echelle spectrometer optimized
for precision Doppler velocimetry. APF features a fixed format spectral range
from 374 nm - 970 nm, and delivers a "Throughput" (resolution * slit width
product) of 114,000 arc-seconds, with spectral resolutions up to 150,000.
Overall system efficiency (fraction of photons incident on the primary mirror
that are detected by the science CCD) on blaze at 560 nm in planet-hunting mode
is 15%. First-light tests on the RV standard stars HD 185144 and HD 9407
demonstrate sub-meter per second precision (RMS per observation) held over a
3-month period. This paper reviews the basic features of the telescope, dome,
and spectrometer, and gives a brief summary of first-light performance.