Normalized to: Buzulutskov, A.
[1]
oai:arXiv.org:2006.11017 [pdf] - 2118344
Electroluminescence and electron avalanching in two-phase detectors
Submitted: 2020-06-19
Electroluminescence and electron avalanching are the physical effects used in
two-phase argon and xenon detectors for dark mater search and neutrino
detection, to amplify the primary ionization signal directly in cryogenic
noble-gas media. We review the concepts of such light and charge signal
amplification, including a combination thereof, both in the gas and in the
liquid phase. Puzzling aspects of the physics of electroluminescence and
electron avalanching in two-phase detectors are explained and detection
techniques based on these effects are described.
[2]
oai:arXiv.org:2004.13355 [pdf] - 2127466
Observation of unusual slow components in electroluminescence signal of
two-phase argon detector
Submitted: 2020-04-28, last modified: 2020-05-08
Proportional electroluminescence (EL) in noble gases is used in two-phase
detectors for dark matter search to record ionization signals in the gas phase
induced by particle scattering in the liquid phase (S2 signals). In this work,
the EL pulse-shapes in a two-phase argon detector have for the first time been
studied systematically in a wide range of reduced electric field, varying from
3 to 9 Td. The pulse-shapes were studied at different readout configurations
and spectral ranges: using cryogenic PMTs and SiPMs, with and without a
wavelength shifter (WLS), in the VUV and visible range. We observed the fast
component and two unusual slow components, with time constants of about 5
$\mu$s and 40 $\mu$s. The unusual characteristic property of slow components
was that their contribution and time constants increased with electric field.
[3]
oai:arXiv.org:2004.13296 [pdf] - 2127465
Observation of primary scintillations in the visible range in liquid
argon doped with methane
Submitted: 2020-04-28
Neutron veto detector based on liquid scintillator containing hydrogen atoms
is an integral part of any underground experiment for dark matter search. So
far, a flammable mixture of liquid hydrocarbons was used as a liquid
scintillator in such detectors. A safe alternative might be a liquid
scintillator based on liquid argon doped with methane. In this work, we have
studied the primary scintillations in pure liquid argon and its mixtures with
methane, the CH4 content varying from 100 ppm to 5%. The primary scintillations
have for the first time been observed in liquid argon doped with methane, in
the visible and near infrared range, and their relative light yields have been
measured as a function of the CH4 content.
[4]
oai:arXiv.org:2004.02024 [pdf] - 2075899
SiPM-matrix readout of two-phase argon detectors using
electroluminescence in the visible and near infrared range
The DarkSide collaboration;
Aalseth, C. E.;
Abdelhakim, S.;
Agnes, P.;
Ajaj, R.;
Albuquerque, I. F. M.;
Alexander, T.;
Alici, A.;
Alton, A. K.;
Amaudruz, P.;
Ameli, F.;
Anstey, J.;
Antonioli, P.;
Arba, M.;
Arcelli, S.;
Ardito, R.;
Arnquist, I. J.;
Arpaia, P.;
Asner, D. M.;
Asunskis, A.;
Ave, M.;
Back, H. O.;
Barbaryan, V.;
Olmedo, A. Barrado;
Batignani, G.;
Bisogni, M. G.;
Bocci, V.;
Bondar, A.;
Bonfini, G.;
Bonivento, W.;
Borisova, E.;
Bottino, B.;
Boulay, M. G.;
Bunker, R.;
Bussino, S.;
Buzulutskov, A.;
Cadeddu, M.;
Cadoni, M.;
Caminata, A.;
Canci, N.;
Candela, A.;
Cantini, C.;
Caravati, M.;
Cariello, M.;
Carnesecchi, F.;
Castellani, A.;
Castello, P.;
Cavalcante, P.;
Cavazza, D.;
Cavuoti, S.;
Cebrian, S.;
Ruiz, J. M. Cela;
Celano, B.;
Cereseto, R.;
Chashin, S.;
Cheng, W.;
Chepurnov, A.;
Cicalò, C.;
Cifarelli, L.;
Citterio, M.;
Coccetti, F.;
Cocco, V.;
Colocci, M.;
Vidal, E. Conde;
Consiglio, L.;
Cossio, F.;
Covone, G.;
Crivelli, P.;
D'Antone, I.;
D'Incecco, M.;
Rolo, M. D. Da Rocha;
Dadoun, O.;
Daniel, M.;
Davini, S.;
De Cecco, S.;
De Deo, M.;
De Falco, A.;
De Gruttola, D.;
De Guido, G.;
De Rosa, G.;
Dellacasa, G.;
Demontis, P.;
De Pasquale, S.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Noto, L.;
Di Pietro, G.;
Di Stefano, P.;
Dionisi, C.;
Dolganov, G.;
Dordei, F.;
Downing, M.;
Edalatfar, F.;
Empl, A.;
Diaz, M. Fernandez;
Filip, C.;
Fiorillo, G.;
Fomenko, K.;
Franceschi, A.;
Franco, D.;
Frolov, E.;
Froudakis, G. E.;
Funicello, N.;
Gabriele, F.;
Gabrieli, A.;
Galbiati, C.;
Garbini, M.;
Abia, P. Garcia;
Fora, D. Gascón;
Gendotti, A.;
Ghiano, C.;
Ghisi, A.;
Giampa, P.;
Giampaolo, R. A.;
Giganti, C.;
Giorgi, M. A.;
Giovanetti, G. K.;
Gligan, M. L.;
Gorchakov, O.;
Grab, M.;
Diaz, R. Graciani;
Grassi, M.;
Grate, J. W.;
Grobov, A.;
Gromov, M.;
Guan, M.;
Guerra, M. B. B.;
Guerzoni, M.;
Gulino, M.;
Haaland, R. K.;
Hackett, B. R.;
Hallin, A.;
Haranczyk, M.;
Harrop, B.;
Hoppe, E. W.;
Horikawa, S.;
Hosseini, B.;
Hubaut, F.;
Humble, P.;
Hungerford, E. V.;
Ianni, An.;
Ilyasov, A.;
Ippolito, V.;
Jillings, C.;
Keeter, K.;
Kendziora, C. L.;
Kochanek, I.;
Kondo, K.;
Kopp, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kugathasan, R.;
Kuss, M.;
La Commara, M.;
La Delfa, L.;
Lai, M.;
Lebois, M.;
Lehnert, B.;
Levashko, N.;
Li, X.;
Liqiang, Q.;
Lissia, M.;
Lodi, G. U.;
Longo, G.;
Lussana, R.;
Luzzi, L.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Manecki, S.;
Mapelli, L.;
Margotti, A.;
Mari, S. M.;
Mariani, M.;
Maricic, J.;
Marinelli, M.;
Marras, D.;
Martínez, M.;
Rojas, A. D. Martinez;
Mascia, M.;
Mason, J.;
Masoni, A.;
McDonald, A. B.;
Messina, A.;
Miletic, T.;
Milincic, R.;
Moggi, A.;
Moioli, S.;
Monroe, J.;
Morrocchi, M.;
Mroz, T.;
Mu, W.;
Muratova, V. N.;
Murphy, S.;
Muscas, C.;
Musico, P.;
Nania, R.;
Napolitano, T.;
Agasson, A. Navrer;
Nessi, M.;
Nikulin, I.;
Nosov, V.;
Nowak, J. A.;
Oleinik, A.;
Oleynikov, V.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Palmas, S.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Pazzona, F.;
Peeters, S.;
Pegoraro, P. A.;
Pelczar, K.;
Pellegrini, L. A.;
Pellegrino, C.;
Pelliccia, N.;
Perotti, F.;
Pesudo, V.;
Picciau, E.;
Pietropaolo, F.;
Pocar, A.;
Pollmann, T. R.;
Portaluppi, D.;
Poudel, S. S.;
Pralavorio, P.;
Price, D.;
Radics, B.;
Raffaelli, F.;
Ragusa, F.;
Razeti, M.;
Regenfus, C.;
Renshaw, A. L.;
Rescia, S.;
Rescigno, M.;
Retiere, F.;
Rignanese, L. P.;
Ripoli, C.;
Rivetti, A.;
Rode, J.;
Romani, A.;
Romero, L.;
Rossi, N.;
Rubbia, A.;
Sala, P.;
Salatino, P.;
Samoylov, O.;
García, E. Sánchez;
Sandford, E.;
Sanfilippo, S.;
Sant, M.;
Santone, D.;
Santorelli, R.;
Savarese, C.;
Scapparone, E.;
Schlitzer, B.;
Scioli, G.;
Segreto, E.;
Seifert, A.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Siddhanta, S.;
Simeone, M.;
Singh, P. N.;
Skensved, P.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sobrero, G.;
Sokolov, A.;
Sotnikov, A.;
Stainforth, R.;
Steri, A.;
Stracka, S.;
Strickland, V.;
Suffritti, G. B.;
Sulis, S.;
Suvorov, Y.;
Szelc, A. M.;
Tartaglia, R.;
Testera, G.;
Thorpe, T.;
Tonazzo, A.;
Tosi, A.;
Tuveri, M.;
Unzhakov, E. V.;
Usai, G.;
Vacca, A.;
Vázquez-Jáuregui, E.;
Viant, T.;
Viel, S.;
Villa, F.;
Vishneva, A.;
Vogelaar, R. B.;
Wahl, J.;
Walding, J. J.;
Wang, H.;
Wang, Y.;
Westerdale, S.;
Wheadon, R. J.;
Williams, R.;
Wilson, J.;
Wojcik, Marcin;
Wojcik, Mariusz;
Wu, S.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zuffa, M.;
Zuzel, G.
Submitted: 2020-04-04
Proportional electroluminescence (EL) in noble gases is used in two-phase
detectors for dark matter search to record (in the gas phase) the ionization
signal induced by particle scattering in the liquid phase. The "standard" EL
mechanism is considered to be due to noble gas excimer emission in the vacuum
ultraviolet (VUV). In addition to it, there are two alternative mechanisms,
producing light in the visible and near infrared (NIR) range. The first is due
to bremsstrahlung of electrons scattered on neutral atoms (so-called neutral
bremsstrahlung, NBrS). The second, responsible for electron avalanche
scintillations in the NIR at higher electric fields, is due to transitions
between excited atomic states. In this work, we have for the first time
demonstrated two alternative techniques of the optical readout of two-phase
argon detectors, in the visible and NIR range, using a SiPM matrix and
electroluminescence due to either neutral bremsstrahlung or avalanche
scintillations effects. The amplitude yield and position resolution were
measured for these readout techniques, which allowed to assess the detection
threshold for electron and nuclear recoils in two-phase argon detectors for
dark matter search. It should be emphasized that this is the first practical
application of the NBrS effect in detection science.
[5]
oai:arXiv.org:2001.08106 [pdf] - 2080977
Design and construction of a new detector to measure ultra-low
radioactive-isotope contamination of argon
The DarkSide Collaboration;
Aalseth, C. E.;
Abdelhakim, S.;
Acerbi, F.;
Agnes, P.;
Ajaj, R.;
Albuquerque, I. F. M.;
Alexander, T.;
Alici, A.;
Alton, A. K.;
Amaudruz, P.;
Ameli, F.;
Anstey, J.;
Antonioli, P.;
Arba, M.;
Arcelli, S.;
Ardito, R.;
Arnquist, I. J.;
Arpaia, P.;
Asner, D. M.;
Asunskis, A.;
Ave, M.;
Back, H. O.;
Olmedo, A. Barrado;
Batignani, G.;
Bisogni, M. G.;
Bocci, V.;
Bondar, A.;
Bonfini, G.;
Bonivento, W.;
Borisova, E.;
Bottino, B.;
Boulay, M. G.;
Bunker, R.;
Bussino, S.;
Buzulutskov, A.;
Cadeddu, M.;
Cadoni, M.;
Caminata, A.;
Canci, N.;
Candela, A.;
Cantini, C.;
Caravati, M.;
Cariello, M.;
Carnesecchi, F.;
Carpinelli, M.;
Castellani, A.;
Castello, P.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavazza, D.;
Cavuoti, S.;
Cebrian, S.;
Ruiz, J. M. Cela;
Celano, B.;
Cereseto, R.;
Cheng, W.;
Chepurnov, A.;
Cicalò, C.;
Cifarelli, L.;
Citterio, M.;
Cocco, A. G.;
Cocco, V.;
Colocci, M.;
Consiglio, L.;
Cossio, F.;
Covone, G.;
Crivelli, P.;
D'Antone, I.;
D'Incecco, M.;
D'Urso, D.;
Rolo, M. D. Da Rocha;
Dadoun, O.;
Daniel, M.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Falco, A.;
De Filippis, G.;
De Gruttola, D.;
De Guido, G.;
De Rosa, G.;
Dellacasa, G.;
Demontis, P.;
DePaquale, S.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Noto, L.;
Di Pietro, G.;
Di Stefano, P.;
Dionisi, C.;
Dolganov, G.;
Dordei, F.;
Downing, M.;
Edalatfar, F.;
Empl, A.;
Diaz, M. Fernandez;
Ferri, A.;
Filip, C.;
Fiorillo, G.;
Fomenko, K.;
Franceschi, A.;
Franco, D.;
Froudakis, G. E.;
Gabriele, F.;
Gabrieli, A.;
Galbiati, C.;
Abia, P. Garcia;
Fora, D. Gascón;
Gendotti, A.;
Ghiano, C.;
Ghisi, A.;
Giagu, S.;
Giampa, P.;
Giampaolo, R. A.;
Giganti, C.;
Giorgi, M. A.;
Giovanetti, G. K.;
Gligan, M. L.;
Gola, A.;
Gorchakov, O.;
Grab, M.;
Diaz, R. Graciani;
Granato, F.;
Grassi, M.;
Grate, J. W.;
Grigoriev, G. Y.;
Grobov, A.;
Gromov, M.;
Guan, M.;
Guerra, M. B. B.;
Guerzoni, M.;
Gulino, M.;
Haaland, R. K.;
Hackett, B. R.;
Hallin, A.;
Harrop, B.;
Hoppe, E. W.;
Horikawa, S.;
Hosseini, B.;
Hubaut, F.;
Humble, P.;
Hungerford, E. V.;
Ianni, An.;
Ilyasov, A.;
Ippolito, V.;
Jillings, C.;
Keeter, K.;
Kendziora, C. L.;
Kim, S.;
Kochanek, I.;
Kondo, K.;
Kopp, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kugathasan, R.;
Kuss, M.;
Kuźniak, M.;
La Commara, M.;
La Delfa, L.;
Lai, M.;
Langrock, S.;
Lebois, M.;
Lehnert, B.;
Levashko, N.;
Li, X.;
Liqiang, Q.;
Lissia, M.;
Lodi, G. U.;
Longo, G.;
Manzano, R. López;
Lussana, R.;
Luzzi, L.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Marcante, M.;
Margotti, A.;
Mari, S. M.;
Mariani, M.;
Maricic, J.;
Marinelli, M.;
Marras, D.;
Martínez, M.;
Morales, J. J. Martínez;
Rojas, A. D. Martinez;
Martoff, C. J.;
Mascia, M.;
Mason, J.;
Masoni, A.;
Mazzi, A.;
McDonald, A. B.;
Messina, A.;
Meyers, P. D.;
Miletic, T.;
Milincic, R.;
Moggi, A.;
Moioli, S.;
Monroe, J.;
Morrocchi, M.;
Mroz, T.;
Mu, W.;
Muratova, V. N.;
Murphy, S.;
Muscas, C.;
Musico, P.;
Nania, R.;
Napolitano, T.;
Agasson, A. Navrer;
Nessi, M.;
Nikulin, I.;
Oleinik, A.;
Oleynikov, V.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Palmas, S.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Paternoster, G.;
Pavletcov, V.;
Pazzona, F.;
Peeters, S.;
Pegoraro, P. A.;
Pelczar, K.;
Pellegrini, L. A.;
Pellegrino, C.;
Pelliccia, N.;
Perotti, F.;
Pesudo, V.;
Picciau, E.;
Piemonte, C.;
Pietropaolo, F.;
Pocar, A.;
Pollman, T.;
Portaluppi, D.;
Poudel, S. S.;
Pralavorio, P.;
Price, D.;
Radics, B.;
Raffaelli, F.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Regazzoni, V.;
Regenfus, C.;
Renshaw, A. L.;
Rescia, S.;
Rescigno, M.;
Retiere, F.;
Rignanese, L. P.;
Rivetti, A.;
Romani, A.;
Romero, L.;
Rossi, N.;
Rubbia, A.;
Sablone, D.;
Sala, P.;
Salatino, P.;
Samoylov, O.;
García, E. Sánchez;
Sanfilippo, S.;
Sant, M.;
Santone, D.;
Santorelli, R.;
Savarese, C.;
Scapparone, E.;
Schlitzer, B.;
Scioli, G.;
Segreto, E.;
Seifert, A.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Siddhanta, S.;
Simeone, M.;
Singh, P. N.;
Skensved, P.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sobrero, G.;
Sokolov, A.;
Sotnikov, A.;
Stainforth, R.;
Steri, A.;
Stracka, S.;
Strickland, V.;
Suffritti, G. B.;
Sulis, S.;
Suvorov, Y.;
Szelc, A. M.;
Tartaglia, R.;
Testera, G.;
Thorpe, T.;
Tonazzo, A.;
Tosi, A.;
Tuveri, M.;
Unzhakov, E. V.;
Usai, G.;
Vacca, A.;
Vázquez-Jáuregui, E.;
Verducci, M.;
Viant, T.;
Viel, S.;
Villa, F.;
Vishneva, A.;
Vogelaar, R. B.;
Wada, M.;
Wahl, J.;
Walding, J. J.;
Wang, H.;
Wang, Y.;
Westerdale, S.;
Wheadon, R. J.;
Williams, R.;
Wilson, J.;
Wojcik, Marcin;
Wojcik, Mariusz;
Wu, S.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zuffa, M.;
Zuzel, G.
Submitted: 2020-01-22
Large liquid argon detectors offer one of the best avenues for the detection
of galactic weakly interacting massive particles (WIMPs) via their scattering
on atomic nuclei. The liquid argon target allows exquisite discrimination
between nuclear and electron recoil signals via pulse-shape discrimination of
the scintillation signals. Atmospheric argon (AAr), however, has a naturally
occurring radioactive isotope, $^{39}$Ar, a $\beta$ emitter of cosmogenic
origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up
concerns. The use of argon extracted from underground wells, deprived of
$^{39}$Ar, is key to the physics potential of these experiments. The
DarkSide-20k dark matter search experiment will operate a dual-phase time
projection chamber with 50 tonnes of radio-pure underground argon (UAr), that
was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger
than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is
crucial for the success of DarkSide-20k, as well as for future experiments of
the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by
the DArT in ArDM experiment, a small chamber made with extremely radio-pure
materials that will be placed at the centre of the ArDM detector, in the
Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an
active veto for background radioactivity, mostly $\gamma$-rays from the ArDM
detector materials and the surrounding rock. This article describes the DArT in
ArDM project, including the chamber design and construction, and reviews the
background required to achieve the expected performance of the detector.
[6]
oai:arXiv.org:1909.00619 [pdf] - 1953832
Electron transport and electric field simulations in two-phase detectors
with THGEM electrodes
Submitted: 2019-09-02
One of the main features of two-phase detectors with electroluminescence (EL)
gap being developed in our laboratory for dark matter search is the extensive
use of THGEMs (Thick Gas Electron Multipliers). In various versions of the
detector, the THGEMs are used as electrodes in the gas and liquid phases to
form the drift, electron emission and EL regions, as well as for avalanche
amplification of a signal in the gas phase. In this work the simulations of the
electric field and electron transport through such THGEM electrodes were
performed. In the liquid phase, these simulations allowed to determine the
optimal parameters, such as the hole diameter of THGEM and applied voltage
across it, that can provide effective transmission of the electrons from the
drift region to that of the EL gap. In the gas phase, the effect of the THGHEM
voltage on the electric field uniformity in the EL gap was studied.
[7]
oai:arXiv.org:1905.05502 [pdf] - 2052567
Neutral bremsstrahlung in two-phase argon electroluminescence: further
studies and possible applications
Submitted: 2019-05-14
We further study the effect of neutral bremsstrahlung (NBrS) in two-phase
argon electroluminescence (EL), revealed recently in [1]. The absolute EL yield
due to NBrS effect, in the visible and NIR range, was remeasured in pure
gaseous argon in the two-phase mode, using a two-phase detector with EL gap
read out directly by cryogenic PMTs and SiPMs. Possible applications of the
NBrS effect in detection science are discussed, including those in two-phase
dark matter detectors.
[8]
oai:arXiv.org:1803.05329 [pdf] - 1712914
Revealing neutral bremsstrahlung in two-phase argon electroluminescence
Submitted: 2018-03-13, last modified: 2018-06-20
Proportional electroluminescence (EL) in noble gases has long been used in
two-phase detectors for dark matter search, to record ionization signals
induced by particle scattering in the noble-gas liquid (S2 signals). Until
recently, it was believed that proportional electroluminescence was fully due
to VUV emission of noble gas excimers produced in atomic collisions with
excited atoms, the latter being in turn produced by drifting electrons. In this
work we consider an additional mechanism of proportional electroluminescence,
namely that of bremsstrahlung of drifting electrons scattered on neutral atoms
(so-called neutral bremsstrahlung); it is systemically studied here both
theoretically and experimentally. In particular, the absolute EL yield has for
the first time been measured in pure gaseous argon in the two-phase mode, using
a dedicated two-phase detector with EL gap optically read out by cryogenic PMTs
and SiPMs. We show that the neutral bremsstrahlung effect can explain two
intriguing observations in EL radiation: that of the substantial contribution
of the non-VUV spectral component, extending from the UV to NIR, and that of
the photon emission at lower electric fields, below the Ar excitation
threshold. Possible applications of neutral bremsstrahlung effect in two-phase
dark matter detectors are discussed.
[9]
oai:arXiv.org:1705.05107 [pdf] - 1583417
Measurement of the ionization yield of nuclear recoils in liquid argon
using a two-phase detector with electroluminescence gap
Bondar, A.;
Buzulutskov, A.;
Dolgov, A.;
Grishnyaev, E.;
Nosov, V.;
Oleynikov, V.;
Polosatkin, S.;
Shekhtman, L.;
Shemyakina, E.;
Sokolov, A.
Submitted: 2017-05-15
A measurement of ionization yields in noble-gas liquids is relevant to the
energy calibration of nuclear recoil detectors for dark matter search and
coherent neutrino-nucleus scattering experiments. In this work we further study
the ionization yield of nuclear recoils in liquid Ar, using a two-phase
detector with an electroluminescence gap and DD neutron generator. The
ionization yields of nuclear recoils in liquid Ar were measured at 233 keV and
electric fields of 0.56 and 0.62 kV/cm; their values amounted to 5.9 $\pm$ 0.8
and 7.4 $\pm$ 1 e$^-$/keV, respectively. The characteristic dependences of the
ionization yield on energy and electric field were determined, while comparing
the results obtained to those at lower energies and higher fields.
[10]
oai:arXiv.org:1705.05101 [pdf] - 1583416
Further studies of proportional electroluminescence in two-phase argon
Submitted: 2017-05-15
The study of proportional electroluminescence in two-phase argon is relevant
in the field of noble-gas liquid detectors for dark matter search and
low-energy neutrino experiments. In this work, we continued to study
proportional electroluminescence (EL) in two-phase argon doped with a minor (9
ppm) admixture of nitrogen, in the VUV, UV and visible spectral ranges. We
confirmed the effect of enhancement of the EL yield, as well as the presence of
non-VUV component in addition to that of VUV, in proportional
electroluminescence in two-phase Ar. On the other hand, the contribution of
non-VUV component determined here within the model of N2 emission in the UV,
turned out to be insufficient to explain the EL yield enhancement effect.
Accordingly, the problem of proportional electroluminescence in two-phase Ar
remains unresolved.
[11]
oai:arXiv.org:1705.01250 [pdf] - 1583058
Study of cryogenic photomultiplier tubes for the future two-phase
cryogenic avalanche detector
Submitted: 2017-05-03
We report the results of a characterization study of several types of
cryogenic photomultipliers manufactured by Hamamatsu Photonics and intended for
operation in liquid Ar conditions, namely: compact 2-inch R6041-506MOD tubes,
3-inch R11065-10 and R11065-MOD tubes for operation in liquid Ar and 3-inch
R11410-20 tubes originally designed for operation in liquid Xe. These types of
PMT are proposed for installation into the future two-phase cryogenic avalanche
detector that is developed in the Laboratory of Cosmology and Particle Physics
of the Novosibirsk State University jointly with the Budker Institute of
Nuclear Physics. Eight R11065 PMTs and seven R11410-20 tubes were tested and
all demonstrated excellent performance in liquid Ar in terms of gain and
relative single electron efficiency. All 3-inch PMTs showed a maximal gain in
liquid Ar above 5x10^6 and relative single electron efficiency higher than 95%.
Compact R6041-506MOD tubes have dynode system different from that of the 3-inch
photomultipliers and thus their single electron energy resolution and relative
efficiency is much worse than that of 3-inch tubes. From 21 2-inch PMTs only 12
tubes were selected with acceptable, i.e. higher than 75%, relative single
electron efficiency and the maximal gain higher than 5x10^6. However, these
PMTs are very attractive because they are the only compact type of tubes that
can operate in liquid Ar.
[12]
oai:arXiv.org:1702.03612 [pdf] - 1555392
Photon emission and atomic collision processes in two-phase argon doped
with xenon and nitrogen
Submitted: 2017-02-12
We present a comprehensive analysis of photon emission and atomic collision
processes in two-phase argon doped with xenon and nitrogen. The dopants are
aimed to convert the VUV emission of pure Ar to the UV emission of the Xe
dopant in the liquid phase and to the near UV emission of the N2 dopant in the
gas phase. Such a mixture is relevant to two-phase dark matter and low energy
neutrino detectors, with enhanced photon collection efficiency for primary and
secondary scintillation signals. Based on this analysis, we show that the
recently proposed hypothesis of the enhancement of the excitation transfer from
Ar to N2 species in the two-phase mode is either incorrect or needs assumption
about a new extreme mechanism of excitation transfer coming into force at lower
temperatures, in particular that of the resonant excitation transfer via ArN2
compound (van der Waals molecule).