Normalized to: Bustos, F.
[1]
oai:arXiv.org:2001.10958 [pdf] - 2039851
A Precise Photometric Ratio via Laser Excitation of the Sodium Layer I:
One-photon Excitation Using 342.78 nm Light
Submitted: 2020-01-29
The largest uncertainty on measurements of dark energy using type Ia
supernovae is presently due to systematics from photometry; specifically to the
relative uncertainty on photometry as a function of wavelength in the optical
spectrum. We show that a precise constraint on relative photometry between the
visible and near-infrared can be achieved at upcoming survey telescopes (such
as at the Vera Rubin Observatory [VRO]) via a mountaintop-located laser source
tuned to the 342.78 nm vacuum excitation wavelength of neutral sodium atoms.
Using a high-power (500 W) laser modified from laser guide star studies, this
excitation will produce an artificial star (which we term a "laser photometric
ratio star," or LPRS) of de-excitation light in the mesosphere that is
observable from the ground at approximately 20 magnitude (i.e., well within the
expected single-image magnitude limit of VRO) at wavelengths in vacuum of
589.16 nm, 589.76 nm, 818.55 nm, and 819.70 nm, with the sum of the numbers of
589.16 nm and 589.76 nm photons produced by this process equal to the sum of
the numbers of 818.55 nm and 819.70 nm photons, establishing a precise
calibration ratio between, for example, the VRO r and z filters. This technique
can thus provide a novel mechanism for establishing a spectrophotometric
calibration ratio of unprecedented precision, from above most of the Earth's
atmosphere, for upcoming telescopic observations across astronomy and
atmospheric physics. This article is the first in a pair of articles on this
topic. The second article of the pair describes an alternative technique to
achieve a similar, but brighter, LPRS than the technique described in this
paper, by using two mountaintop-located lasers, at optical frequencies
approximately 4 GHz away from resonances at wavelengths in vacuum of 589.16 nm
and 819.71 nm respectively.
[2]
oai:arXiv.org:2001.02717 [pdf] - 2028465
Frequency chirped continuous-wave sodium laser guide stars
Submitted: 2020-01-08
We numerically study a method to increase the photon return flux of
continuous-wave laser guide stars using one-dimensional atomic cooling
principles. The method relies on chirping the laser towards higher frequencies
following the change in velocity of sodium atoms due to recoil, which raises
atomic populations available for laser excitation within the Doppler
distribution. The efficiency of this effect grows with the average number of
atomic excitations between two atomic collisions in the mesosphere. We find the
parameters for maximizing the return flux and evaluate the performance of
chirping for operation at La Palma. According to our simulations, the optimal
chirp rate lies between 0.8-1.0 MHz/$\mu$s and an increase in the fluorescence
of the sodium guide star up to 60% can be achieved with current 20 W-class
guide star lasers.
[3]
oai:arXiv.org:1802.04686 [pdf] - 1771499
Remote sensing of geomagnetic fields and atomic collisions in the
mesosphere
Submitted: 2018-02-09
Magnetic-field sensing has contributed to the formulation of the
plate-tectonics theory, the discovery and mapping of underground structures on
Earth, and the study of magnetism in other planets. Filling the gap between
space-based and near-Earth observation, we demonstrate a novel method for
remote measurement of the geomagnetic field at an altitude of 85-100 km. The
method consists of optical pumping of atomic sodium in the upper mesosphere
with an intensity-modulated laser beam, and simultaneous ground-based
observation of the resultant magneto-optical resonance when driving the
atomic-sodium spins at the Larmor precession frequency. The experiment was
carried out at the Roque de Los Muchachos Observatory in La Palma (Canary
Islands) where we validated this technique and remotely measured the Larmor
precession frequency of sodium as 260.4(1) kHz, corresponding to a mesospheric
magnetic field of 0.3720(1) G. We demonstrate a magnetometry accuracy level of
0.28 mG/$\sqrt{\text{Hz}}$ in good atmospheric conditions. In addition, these
observations allow us to characterize various atomic-collision processes in the
mesosphere. Remote detection of mesospheric magnetic fields has potential
applications such as mapping of large-scale magnetic structures in the
lithosphere and the study of electric-current fluctuations in the ionosphere.