sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Bussolotti, A.

Normalized to: Bussolotti, A.

2 article(s) in total. 20 co-authors, from 1 to 2 common article(s). Median position in authors list is 3,0.

[1]  oai:arXiv.org:1805.10486  [pdf] - 1832126
First model independent results from DAMA/LIBRA-phase2
Comments: 28 pages, 17 figures, 5 tables. In press on Journal Nucl. Phys. and Atomic Energy. arXiv admin note: substantial text overlap with arXiv:1308.5109, arXiv:1002.1028, arXiv:1306.1411
Submitted: 2018-05-26, last modified: 2019-01-11
The first model independent results obtained by the DAMA/LIBRA-phase2 experiment are presented. The data have been collected over 6 annual cycles corresponding to a total exposure of 1.13 ton $\times$ yr, deep underground at the Gran Sasso National Laboratory (LNGS) of the I.N.F.N. The DAMA/LIBRA-phase2 apparatus, $\simeq$ 250 kg highly radio-pure NaI(Tl), profits from a second generation high quantum efficiency photomultipliers and of new electronics with respect to DAMA/LIBRA-phase1. The improved experimental configuration has also allowed to lower the software energy threshold. New data analysis strategies are presented. The DAMA/LIBRA-phase2 data confirm the evidence of a signal that meets all the requirements of the model independent Dark Matter (DM) annual modulation signature, at 9.5 $\sigma$ C.L. in the energy region (1-6) keV. In the energy region between 2 and 6 keV, where data are also available from DAMA/NaI and DAMA/LIBRA-phase1 (exposure $1.33$ ton $\times$ yr, collected over 14 annual cycles), the achieved C.L. for the full exposure (2.46 ton $\times$ yr) is 12.9 $\sigma$; the modulation amplitude of the single-hit scintillation events is: $(0.0103 \pm 0.0008)$ cpd/kg/keV, the measured phase is $(145 \pm 5)$ days and the measured period is $(0.999 \pm 0.001)$ yr, all these values are well in agreement with those expected for DM particles. No systematics or side reaction able to mimic the exploited DM signature (i.e. to account for the whole measured modulation amplitude and to simultaneously satisfy all the requirements of the signature), has been found or suggested by anyone throughout some decades thus far.
[2]  oai:arXiv.org:0804.2738  [pdf] - 11842
The DAMA/LIBRA apparatus
Comments: 37 pages, 27 figures
Submitted: 2008-04-17
The $\simeq$ 250 kg highly radiopure NaI(Tl) DAMA/LIBRA apparatus, running at the Gran Sasso National Laboratory (LNGS) of the I.N.F.N., is described.