Normalized to: Bush, N.
[1]
oai:arXiv.org:1801.01068 [pdf] - 1612084
Importance of charge capture in inter-phase regions during readout of
charge-coupled devices
Submitted: 2018-01-03
The current understanding of charge transfer dynamics in Charge-Coupled
Devices (CCDs) is that charge is moved so quickly from one phase to the next in
a clocking sequence and with a density so low that trapping of charge in the
inter-phase regions is negligible. However, new simulation capabilities
developed at the Centre for Electronic Imaging, that includes direct input of
electron density simulations, has made it possible to investigate this
assumption further. As part of the radiation testing campaign of the Euclid
CCD273 devices, data has been obtained using the trap pumping method, that can
be used to identify and characterise single defects CCDs. Combining this data
with simulations, we find that trapping during the transfer of charge between
phases is indeed necessary in order to explain the results of the data
analysis. This result could influence not only trap pumping theory and how trap
pumping should be performed, but also how a radiation damaged CCD is read out
in the most optimal way.
[2]
oai:arXiv.org:1601.01761 [pdf] - 1337487
Technology advancement of the CCD201-20 EMCCD for the WFIRST coronagraph
instrument: sensor characterization and radiation damage
Harding, Leon K.;
Demers, Richard T.;
Hoenk, Michael;
Peddada, Pavani;
Nemati, Bijan;
Cherng, Michael;
Michaels, Darren;
Neat, Leo S.;
Loc, Anthony;
Bush, Nathan;
Hall, David;
Murray, Neil;
Gow, Jason;
Burgon, Ross;
Holland, Andrew;
Reinheimer, Alice;
Jorden, Paul R.;
Jordand, Douglas
Submitted: 2016-01-07
The Wide Field InfraRed Survey Telescope-Astrophysics Focused Telescope Asset
(WFIRST-AFTA) mission is a 2.4-m class space telescope that will be used across
a swath of astrophysical research domains. JPL will provide a high-contrast
imaging coronagraph instrument - one of two major astronomical instruments. In
order to achieve the low noise performance required to detect planets under
extremely low flux conditions, the electron multiplying charge-coupled device
(EMCCD) has been baselined for both of the coronagraph's sensors - the imaging
camera and integral field spectrograph. JPL has established an EMCCD test
laboratory in order to advance EMCCD maturity to technology readiness level-6.
This plan incorporates full sensor characterization, including read noise, dark
current, and clock-induced charge. In addition, by considering the unique
challenges of the WFIRST space environment, degradation to the sensor's charge
transfer efficiency will be assessed, as a result of damage from high-energy
particles such as protons, electrons, and cosmic rays. Science-grade CCD201-20
EMCCDs have been irradiated to a proton fluence that reflects the projected
WFIRST orbit. Performance degradation due to radiation displacement damage is
reported, which is the first such study for a CCD201-20 that replicates the
WFIRST conditions. In addition, techniques intended to identify and mitigate
radiation-induced electron trapping, such as trap pumping, custom clocking, and
thermal cycling, are discussed.