Normalized to: Burnham, J.
[1]
oai:arXiv.org:1910.13319 [pdf] - 2034456
Palomar Gattini-IR: Survey overview, data processing system, on-sky
performance and first results
De, Kishalay;
Hankins, Matthew J.;
Kasliwal, Mansi M.;
Moore, Anna M.;
Ofek, Eran O.;
Adams, Scott M.;
Ashley, Michael C. B.;
Babul, Aliya-Nur;
Bagdasaryan, Ashot;
Burdge, Kevin B.;
Burnham, Jill;
Dekany, Richard G.;
Declacroix, Alexander;
Galla, Antony;
Greffe, Tim;
Hale, David;
Jencson, Jacob E.;
Lau, Ryan M.;
Mahabal, Ashish;
McKenna, Daniel;
Sharma, Manasi;
Shopbell, Patrick L.;
Smith, Roger M.;
Soon, Jamie;
Sokoloski, Jennifer;
Soria, Roberto;
Travouillon, Tony
Submitted: 2019-10-29
(Abridged) Palomar Gattini-IR is a new wide-field, near-infrared robotic time
domain survey operating at Palomar Observatory. Using a 30 cm telescope mounted
with a H2RG detector, Gattini-IR achieves a field of view of 25 sq. deg. with a
pixel scale of 8.7" in J-band. Here, we describe the system design, survey
operations, data processing system and on-sky performance of Palomar
Gattini-IR. As a part of the nominal survey, Gattini-IR scans $\approx 7500$
square degrees of the sky every night to a median 5$\sigma$ depth of $15.7$ AB
mag outside the Galactic plane. The survey covers $\approx 15000$ square
degrees of the sky visible from Palomar with a median cadence of 2 days. A
real-time data processing system produces stacked science images from dithered
raw images taken on sky, together with PSF-fit source catalogs and transient
candidates identified from subtractions within a median delay of $\approx 4$
hours from the time of observation. The calibrated data products achieve an
astrometric accuracy (RMS) of $\approx 0.7$" with respect to Gaia DR2 for
sources with S/N $> 10$, and better than $\approx 0.35$" for sources brighter
than $\approx 12$ Vega mag. The photometric accuracy (RMS) achieved in the
PSF-fit source catalogs is better than $\approx 3$% for sources brighter than
$\approx 12$ Vega mag, as calibrated against the 2MASS catalog. With a field of
view $\approx 40\times$ larger than any other existing near infrared imaging
instrument, Gattini-IR is probing the reddest and dustiest transients in the
local universe such as dust obscured supernovae in nearby galaxies, novae
behind large columns of extinction within the galaxy, reddened micro-lensing
events in the Galactic plane and variability from cool and dust obscured stars.
We present results from transients and variables identified since the start of
the commissioning period.
[2]
oai:arXiv.org:0709.2719 [pdf] - 5059
Wide Field Hard X-ray Survey Telescope: ProtoEXIST1
Hong, J.;
Grindlay, J. E.;
Chammas, N.;
Allen, B.;
Copete, A.;
Said, B.;
Burke, M.;
Howell, J.;
Gauron, T.;
Baker, R. G.;
Barthelmy, S. D.;
Sheikh, S.;
Gehrels, N.;
Cook, W. R.;
Burnham, J. A.;
Harrison, F. A.;
Collins, J.;
Labov, S.;
Garson, A.;
Krawczynski, H.
Submitted: 2007-09-17
We report our progress on the development of pixellated imaging CZT detector
arrays for our first-generation balloon-borne wide-field hard X-ray (20 - 600
keV) telescope, ProtoEXIST1. Our ProtoEXIST program is a pathfinder for the
High Energy Telescope (HET) on the Energetic X-ray Imaging Survey telescope
(EXIST), a proposed implementation of the Black Hole Finder Probe. ProtoEXIST1
consists of four independent coded-aperture telescopes with close-tiled (~0.4
mm gaps) CZT detectors that preserve their 2.5mm pixel pitch. Multiple
shielding/field-of-view configurations are planned to identify optimal geometry
for the HET in EXIST. The primary technical challenge in ProtoEXIST is the
development of large area, close-tiled modules of imaging CZT detectors (1000
cm2 for ProtoEXIST1), with all readout and control systems for the ASIC readout
vertically stacked. We describe the overall telescope configuration of
ProtoEXIST1 and review the current development status of the CZT detectors,
from individual detector crystal units (DCUs) to a full detector module (DM).
We have built the first units of each component for the detector plane and have
completed a few Rev2 DCUs (2x2 cm2), which are under a series of tests. Bare
DCUs (pre-crystal bonding) show high, uniform ASIC yield (~70%) and ~30%
reduction in electronics noise compared to the Rev1 equivalent. A Rev1 DCU
already achieved ~1.2% FWHM at 662 keV, and preliminary analysis of the initial
radiation tests on a Rev2 DCU shows ~ 4 keV FWHM at 60 keV (vs. 4.7 keV for
Rev1). We therefore expect about <~1% FWHM at 662 keV with the Rev2 detectors.
[3]
oai:arXiv.org:astro-ph/0608711 [pdf] - 84588
CZT imaging detectors for ProtoEXIST
Hong, J.;
Grindlay, J. E.;
Chammas, N.;
Copete, A.;
Baker, R. G.;
Barthelmy, S. D.;
Gehrels, N.;
Cook, W. R.;
Burnham, J. A.;
Harrison, F. A.;
Collins, J.;
Craig, W. W.
Submitted: 2006-08-31
We describe the detector development for a balloon-borne wide-field hard
X-ray (20 - 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both
technology and science of the proposed implementation of the Black Hole Finder
Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal
technology challenge is the development of large area, close-tiled modules of
imaging CZT detectors (1000 cm2 for ProtoEXIST1). We review the updates of the
detector design and package concept for ProtoEXIST1 and report the current
development status of the CZT detectors, using calibration results of our basic
detector unit - 2 x 2 x 0.5 cm CZT crystals with 2.5 mm pixels (8 x 8 array).
The current prototype (Rev1) of our detector crystal unit (DCU) shows ~4.5 keV
electronics noise (FWHM), and the radiation measurements show the energy
resolution (FWHM) of the units is 4.7 keV (7.9%) at 59.5 keV, 5.6 keV (4.6%) at
122 keV, and 7.6 keV (2.1%) at 356 keV. The new (Rev2) DCU with revised design
is expected to improve the resolution by ~30%.