Normalized to: Burger, A.
[1]
oai:arXiv.org:1410.6437 [pdf] - 889983
Scintillation properties of SrI_2(Eu^2+) (Strontium iodide doped with
europium) for high energy astrophysical detectors: Nonproportionality as a
function of temperature and at high gamma-ray energies
Submitted: 2014-10-23
Strontium iodide doped with europium is a new scintillator material being
developed as an alternative to lanthanum bromide doped with cerium for use in
high energy astrophysical detectors. As with all scintillators, the issue of
nonproportionality is important because it affects the energy resolution of the
detector. In this study, we investigate how the nonproportionality of strontium
iodide doped with europium changes as a function of temperature 16 deg. C to 60
deg. C by heating the strontium iodide doped with europium scintillator
separate from the photomultiplier tube. In a separate experiment, we also
investigate the nonproportionality at high energies (up to 6 MeV) of strontium
iodide doped with europium at a testing facility located at NASA Goddard Space
Flight Center. We find that the nonproportionality increases nearly
monotonically as the temperature of the strontium iodide doped with europium
scintillator is increased, although there is evidence of non-monotonic behavior
near 40 deg. C, perhaps due to electric charge carriers trapping in the
material. We also find that within the energy range of 662 keV to 6.1 MeV, the
change in the nonproportionality of the strontium iodide doped with europium is
about 1.5 to 2 percent.
[2]
oai:arXiv.org:0811.3201 [pdf] - 18703
Fabrication and Test of Pixelated CZT Detectors with Different Pixel
Pitches and Thicknesses
Li, Q.;
Garson, A.;
Dowkontt, P.;
Martin, J.;
Beilicke, M.;
Jung, I.;
Groza, M.;
Burger, A.;
De Geronimo, G.;
Krawczynski, H.;
.;
.;
.;
.
Submitted: 2008-11-19
The main methods grown Cadmium Zinc Telluride (CZT) crystals with high yield
and excellent homogeneity are Modified Horizontal Bridgman (MHB) and High
Pressure Bridgman (HPB) processes, respectively. In this contribution, the
readout system based on two 32-channel NCI-ASICs for pixellated CZT detector
arrays has been developed and tested. The CZT detectors supplied by Orbotech
(MHB) and eV products (HPB) are tested by NCI-ASIC readout system. The CZT
detectors have an array of 8x8 or 11x11 pixel anodes fabricated on the anode
surface with the area up to 2 cm x2 cm and the thickness of CZT detectors
ranges from 0.5 cm to 1 cm. Energy spectra resolution and electron
mobility-lifetime products of 8x8 pixels CZT detector with different
thicknesses have been investigated.
[3]
oai:arXiv.org:0712.1178 [pdf] - 7868
Test of CZT Detectors with Different Pixel Pitches and Thicknesses
Submitted: 2007-12-07
The Modified Horizontal Bridgman (MHB) process produces Cadmium Zinc
Telluride (CZT) crystals with high yield and excellent homogeneity. Various
groups,including our own, previously reported on the test of 2x2x0.5 cm3 MHB
CZT detectors grown by the company Orbotech and read out with 8x8 pixels. In
this contribution, we describe the optimization of the photolithographic
process used for contacting the CZT detector with pixel contacts. The optimized
process gives a high yield of good pixels down to pixel diameters/pitches of 50
microns. Furthermore, we discuss the performance of 0.5 cm and 0.75 cm thick
detectors contacted with 64 and 225 pixel read out with the RENA-3 ASICs from
the company NOVA R&D.
[4]
oai:arXiv.org:0710.2655 [pdf] - 6011
Detailed Studies of Pixelated CZT Detectors Grown with the Modified
Horizontal Bridgman Method
Submitted: 2007-10-14
The detector material Cadmium Zinc Telluride (CZT), known for its high
resolution over a broad energy range, is produced mainly by two methods: the
Modified High-Pressure Bridgman (MHB) and the High-Pressure Bridgman (HPB)
process. This study is based on MHB CZT substrates from the company Orbotech
Medical Solutions Ltd. with a detector size of 2.0x2.0x0.5 cm^3, 8x8 pixels and
a pitch of 2.46 mm. Former studies have emphasized only on the cathode material
showing that high-work-function improve the energy resolution at lower
energies. Therfore, we studied the influence of the anode material while
keeping the cathode material constant. We used four different materials:
Indium, Titanium, Chromium and Gold with work-functions between 4.1 eV and 5.1
eV. The low work-function materials Indium and Titanium achieved the best
performance with energy resolutions: 2.0 keV (at 59 keV) and 1.9 keV (at 122
keV) for Titanium; 2.1 keV (at 59 keV) and 2.9 keV (at 122 keV) for Indium.
These detectors are very competitive compared with the more expensive ones
based on HPB material if one takes the large pixel pitch of 2.46 mm into
account. We present a detailed comparison of our detector response with 3-D
simulations, from which we determined the mobility-lifetime-products for
electrons and holes. Finally, we evaluated the temperature dependency of the
detector performance and mobility-lifetime-products, which is important for
many applications. With decreasing temperature down to -30C the breakdown
voltage increases and the electron mobility-lifetime-product decreases by about
30% over a range from 20C to -30C. This causes the energy resolution to
deteriorate, but the concomitantly increasing breakdown voltage makes it
possible to increase the applied bias voltage and restore the full performance.
[5]
oai:arXiv.org:astro-ph/0608673 [pdf] - 84550
Test of Thick Pixelated Orbotech Detectors with and without Steering
Grids
Submitted: 2006-08-30
We report here on the optimization of 0.5 cm thick pixelated Orbotech CZT
detectors with regards to the best contacting materials and the use of steering
grids. We evaluated the performance of different contacting materials. Our
study differs from earlier ones in that we investigated the performance of
different anode and cathode materials separately. We obtain the best
performance with Au cathodes. For different anode materials Ti and In give the
best energy resolutions. The detector (2.0 x 2.0 x 0.5 cm, 8 x 8 pixels) shows
excellent 59 keV, 122 keV and 662 keV energy resolutions of 1.4 keV, 1.9 keV,
and 7.4 keV, respectively. Furthermore, we report on using steering grids to
improve on the performance of the pixelated detectors. Previously, the benefit
of steering grids had been limited by additional electronic noise associated
with currents between the negatively biased steering grids and the anode
pixels. We are currently exploring the possibility to isolate the steering grid
from the CZT substrates by a thin layer of Al$_2$O$_3$. We performed a series
of measurements to determine by how much the isolation layer reduces the
grid-pixel currents. Comparing the currents between two Au contacts before and
after isolating one of the two contacts from the CZT with a 700 nm thick layer
of Al2O3, we measure that the isolation layer reduces the currents by a factor
of about 10 at 500 V. We present some results from a detector before and after
deposition of an isolated steering grid. The grid indeed improves on the
detectors energy resolution and detection efficiency. We show that simulations
can be used to model the anode to cathode charge correlation in excellent
agreement with the experimental results.
[6]
oai:arXiv.org:astro-ph/0511575 [pdf] - 77933
Thick Pixelated CZT Detectors With Isolated Steering Grids
Submitted: 2005-11-18
We explore the possibility to improve the performance of 0.5 cm thick Cadmium
Zinc Telluride (CZT) detectors with the help of steering grids on the anode
side of the detectors. Steering grids can improve the energy resolution of CZT
detectors by enhancing the small pixel effect; furthermore, they can increase
their detection efficiency by steering electrons to the anode pixels which
otherwise would drift to the area between pixels. Previously, the benefit of
steering grids had been compromised by additional noise associated with
currents between the steering grids and the anode pixels. We use thin film
deposition techniques to isolate the steering grid from the CZT substrate by a
150 nm thick layer of the isolator Aluminiumoxide. While the thin layer does
not affect the beneficial effect of the steering grid on the weighting
potentials and the electric field inside the detector, it suppresses the
currents between the steering grid and the anode pixels. In this contribution,
we present first results from a 2 x 2 x 0.5 cm CZT detector with 8 x 8 pixels
that we tested before and after deposition of an isolated steering grid. The
steering grid improves the 662 keV energy resolution of the detector by a
factor of 1.3 (from about 2% to about 1.5%), while not reducing the detection
efficiency. To gain further insights into the detector response in the region
between pixels, we measured energy spectra with a collimated Cs137 source. The
collimator measurements can be used to enhance our understanding of energy
spectra measured under flood illumination of the detectors.
[7]
oai:arXiv.org:astro-ph/0508623 [pdf] - 75512
Direct comparison of the performance of CZT detectors contacted with
various metals
Submitted: 2005-08-29
Cadmium Zinc Telluride (CZT) achieves excellent spatial resolution and good
energy resolution over the broad energy range from several keV into the MeV
energy range. In this paper we present the results of a systematic study of the
performance of CZT detectors manufacturered by Orbotech (before IMARAD)
depending on surface preparation, contact materials and contact deposition. The
standard Orbotech detectors have the dimension of 2.0 x 2.0 x 0.5 cm. They have
a pixellated In anode with 8 x 8 pixels and a monolithic In cathode. Using the
same CZT substrates several times, we have made a direct comparison of the
performance of different contact materials by replacing the cathode and/or the
anode contacts with several high-workfunction metals. We present the
performance of the detectors and conclude with an overview over our ongoing
detector optimization.
[8]
oai:arXiv.org:astro-ph/0410077 [pdf] - 67927
Thick CZT Detectors for Space-Borne X-ray Astronomy
Submitted: 2004-10-04
Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field
of hard X-ray astronomy. Without the need for cryogenic cooling they achieve
good spatial and energy resolutions over the broad energy range from 10 keV to
600 keV. In this paper, we briefly review the historical development of
detectors used in X-ray astronomy. Subsequently, we present an evaluation of
CZT detectors from the company Imarad. The standard 2x2x0.5 cm detectors,
contacted with 8x8 In pixels and an In cathode, exhibit FWHM energy resolutions
of 7 keV at 59 keV, and 10 keV at 662 keV. A direct measurement of the 662 keV
photopeak efficiency gives 67%. We have started a detailed study of the
performance of Imarad detectors depending on surface preparation, contact
materials, contact deposition, post-deposition detector annealing, and detector
passivation techniques. We present first results from contacting detectors with
Cr, Ag, Au, and Pt.