[1]  oai:arXiv.org:1303.7107  [pdf] - 645166
Direct Majorana quasiparticles heat capacity observation by $^3$He Dark Matter detector
Comments: 6 pages, 3 figures
Submitted: 2013-03-28
The Majorana fermion: fermion that is its own antiparticle, was predicted by Majorana in 1937. No fundamental particles are known to be Majorana fermions, although there are speculations that the neutrino is one. Many proposed theories assumes that the mysterious 'dark matter', which forms the greatest part of the universe, is composed of Majorana fermions. Even Majorana does not yet observed as a stable particle, its can be also exist as a quasiparticle in the edge of topological isolators. Here we reports the Dark Matter bolometer time constant deviation which is the result of additional Majorana heat capacity.
[2]  oai:arXiv.org:physics/0611273  [pdf] - 119197
Bolometric calibration of a superfluid $^3$He detector for Dark Matter search: direct measurement of the scintillated energy fraction for neutron, electron and muon events
Comments: 17 pages, submitted to Nuc. Instr. Meth. A
Submitted: 2006-11-28
We report on the calibration of a superfluid $^3$He bolometer developed for the search of non-baryonic Dark Matter. Precise thermometry is achieved by the direct measurement of thermal excitations using Vibrating Wire Resonators (VWRs). The heating pulses for calibration were produced by the direct quantum process of quasiparticle generation by other VWRs present. The bolometric calibration factor is analyzed as a function of temperature and excitation level of the sensing VWR. The calibration is compared to bolometric measurements of the nuclear neutron capture reaction and heat depositions by cosmic muons and low energy electrons. The comparison allows a quantitative estimation of the ultra-violet scintillation rate of irradiated helium, demonstrating the possibility of efficient electron recoil event rejection.
[3]  oai:arXiv.org:astro-ph/0606350  [pdf] - 82790
$^3$He experimentum crucis for Dark Matter puzzles
Comments: 18 pages, 7 figures
Submitted: 2006-06-14
The leading direct dark matter search experiments: CDMS, Edelweis and DAMA/NaI exhibit different results for different approaches to the problem. This contradiction can reflect a nontrivial and probably a multi-component nature of the cosmological dark matter. WIMPs can possess dominantly a Spin Dependent interaction with nucleons. They can be superheavy or represent atom-like systems of superheavy charged particles. The Dark matter can contain a component, which strongly interacts with the matter. We show that even a moderate size superfluid $^3$He detector provides a crucial test for these hypotheses and that its existing laboratory prototype is already of interest for the experimental dark matter search.
[4]  oai:arXiv.org:astro-ph/0604024  [pdf] - 387099
An analysis method for time ordered data processing of Dark Matter experiments
Comments:
Submitted: 2006-04-03
The analysis of the time ordered data of Dark Matter experiments is becoming more and more challenging with the increase of sensitivity in the ongoing and forthcoming projects. Combined with the well-known level of background events, this leads to a rather high level of pile-up in the data. Ionization, scintillation as well as bolometric signals present common features in their acquisition timeline: low frequency baselines, random gaussian noise, parasitic noise and signal characterized by well-defined peaks. In particular, in the case of long-lasting signals such as bolometric ones, the pile-up of events may lead to an inaccurate reconstruction of the physical signal (misidentification as well as fake events). We present a general method to detect and extract signals in noisy data with a high pile-up rate and qe show that events from few keV to hundreds of keV can be reconstructed in time ordered data presenting a high pile-up rate. This method is based on an iterative detection and fitting procedure combined with prior wavelet-based denoising of the data and baseline subtraction. {We have tested this method on simulated data of the MACHe3 prototype experiment and shown that the iterative fitting procedure allows us to recover the lowest energy events, of the order of a few keV, in the presence of background signals from a few to hundreds of keV. Finally we applied this method to the recent MACHe3 data to successfully measure the spectrum of conversion electrons from Co57 source and also the spectrum of the background cosmic muons.
[5]  oai:arXiv.org:astro-ph/0504629  [pdf] - 72726
MACHe3, a prototype for non-baryonic dark matter search: KeV event detection and multicell correlation
Comments:
Submitted: 2005-04-28
Superfluid He3 at ultra-low temperatures (100 microKelvins) is a sensitive medium for the bolometric detection of particles. MACHe3 (MAtrix of Cells of Helium 3) is a project for non-baryonic dark matter search using He3 as a sensitive medium. Simulations made on a high granularity detector show a very good rejection to background signals. A multicell prototype including 3 bolometers has been developed to allow correlations between the cells for background event discrimination. One of the cells contains a low activity Co57 source providing conversion electrons of 7.3 and 13.6 keV to confirm the detection of low energy events. First results on the multicell prototype are presented. A detection threshold of 1 keV has been achieved. The detection of low energy conversion electrons coming from the Co57 source is highlighted as well as the cosmic muon spectrum measurement. The possibility to reject background events by using the correlation among the cells is demonstrated from the simultaneous detection of muons in different cells.
[6]  oai:arXiv.org:astro-ph/0504272  [pdf] - 387088
Low energy conversion electron detection in superfluid He3 at ultra-low temperature
Comments: 8 pages, 3 figures, to appear in NIMA
Submitted: 2005-04-12
We report on the first results of the MACHe3 (MAtrix of Cells of Helium 3) prototype experiment concerning the measurement of low energy conversion electrons at ultra-low temperature. For the first time, the feasibility of the detection of low energy electrons is demonstrated in superfluid He3-B cooled down to 100 microK. Low energy electrons at 7.3 keV coming from the K shell conversion of the 14.4 keV nuclear transition of a low activity Co57 source are detected, opening the possibility to use a He3-based detector for the detection of Weakly Interacting Massive Particles (WIMPs) which are expected to release an amount of energy higher-bounded by 5.6 keV.
[7]  oai:arXiv.org:astro-ph/0309325  [pdf] - 59152
Project of a superfluid He3 detector for direct detection of non-baryonic dark matter : MACHe3
Comments: 5 pages, 5 figures, to appear in Proceedings of the 4th Marseille International Cosmology Conference
Submitted: 2003-09-11
MACHe3 (MAtrix of Cells of superfluid Helium 3) is a project of non-baryonic Dark Matter search using superfluid He3 as sensitive medium. Simulations on a high granularity matrix show very good rejection against background events. First results on a prototype cell are very encouraging. Neutron detection has been highlighted as well as cosmic muon detection. A phenomenological study has been done with the DarkSUSY code to investigate complementarity of MACHe3 with existing Dark Matter detectors.
[8]  oai:arXiv.org:astro-ph/0211294  [pdf] - 1591941
MACHe3: A new generation detector for non-baryonic dark matter direct detection
Comments: 6 pages, 3 figures, Proceedings of the 4th International Workshop on the Identification of Dark Matter (York, UK, 09/02/2002-09/06/2002)
Submitted: 2002-11-13
MACHe3 (MAtrix of Cells of superfluid He3) is a project of a new detector for direct Dark Matter (DM) search, using superfluid as a sensitive medium. An experiment on a prototype cell has been performed and the first results reported here are encouraging to develop of a multicell prototype. In order to investigate the discovery potential of MACHe3, and its complementarity with other DM detectors, a phenomenological study done with the DarkSUSY code is shown.
[9]  oai:arXiv.org:astro-ph/0201097  [pdf] - 1232816
Search for Supersymmetric Dark Matter with Superfluid He3 (MACHe3)
Comments: 15 pages, 5 figures, submitted to Phys. Letters B, minor changes in the text
Submitted: 2002-01-07, last modified: 2002-04-30
MACHe3 (MAtrix of Cells of superfluid He3) is a project of a new detector for direct Dark Matter search, using superfluid He3 as a sensitive medium. This paper presents a phenomenological study done with the DarkSUSY code, in order to investigate the discovery potential of this project of detector, as well as its complementarity with existing and planned devices.
[10]  oai:arXiv.org:astro-ph/0011292  [pdf] - 1507842
A superfluid He3 detector for direct dark matter search
Comments: 6 pages, 3 figures, Proceedings of the 3rd International Workshop on the Identification of Dark Matter (York, UK, 09/18/2000-09/22/2000)
Submitted: 2000-11-15
MACHe3 (MAtrix of Cells of superfluid He3) is a project of a new detector for direct Dark Matter Search. The idea is to use superfluid He3 as a sensitive medium. The existing device, the superfluid He3 cell, will be briefly introduced. Then a description of the MACHe3 project will be presented, in particular the background rejection and the neutralino event rate that may be achieved with such a device.
[11]  oai:arXiv.org:astro-ph/0005332  [pdf] - 36103
A project of a new detector for direct Dark Matter search: MACHe3
Comments: 8 pages, 7 figures, Proceedings of Dark Matter 2000 (Marina Del Rey, Los Angeles, USA, 02/23/2000-02/25/2000)
Submitted: 2000-05-16
MACHe3 (MAtrix of Cells of superfluid He3) is a project of a new detector for direct Dark Matter (DM) search. A cell of superfluid He3 has been developed and the idea of using a large number of such cells in a high granularity detector is proposed.This contribution presents, after a brief description of the superfluid He3 cell, the simulation of the response of different matrix configurations allowing to define an optimum design as a function of the number of cells and the volume of each cell. The exclusion plot and the predicted interaction cross-section for the neutralino as a photino are presented.
[12]  oai:arXiv.org:astro-ph/0002303  [pdf] - 387019
Design optimization of MACHe3, a project of superfuid He3 detector for direct Dark Matter search
Comments: 20 pages, 12 figures
Submitted: 2000-02-15
MACHe3 (MAtrix of Cells of superfluid He3) is a project of a new detector for direct Dark Matter (DM) search. A cell of superfluid He3 has been developed and the idea of using a large number of such cells in a high granularity detector is proposed. This paper presents, after a brief description of the superfluid He3 cell, the simulation of the response of different matrix configurations allowing to define an optimum design as a function of the number of cells and the volume of each cell. The background rejection, for several configurations, is presented both for neutrons and gamma-rays of various kinetic energies.