Normalized to: Bumble, B.
[1]
oai:arXiv.org:2004.00736 [pdf] - 2085203
Characterization of sputtered hafnium thin films for high quality factor
microwave kinetic inductance detectors
Submitted: 2020-04-01
Hafnium is an elemental superconductor which crystallizes in a hexagonal
close packed structure, has a transition temperature $T_{C} \simeq 400 mK$, and
has a high normal state resistivity around $90 \mu \Omega. cm$. In Microwave
Kinetic Inductance Detectors (MKIDs), these properties are advantageous since
they allow for creating detectors sensitive to optical and near infra-red
radiation. In this work, we study how sputter conditions and especially the
power applied to the target during the deposition, affect the hafnium $T_{C}$,
resistivity, stress, texture and preferred crystal orientation. We find that
the position of the target with respect to the substrate strongly affects the
orientation of the crystallites in the films and the internal quality factor,
$Q_{i}$, of MKIDs fabricated from the films. In particular, we demonstrate that
a DC magnetron sputter deposition at a normal angle of incidence, low pressure,
and low plasma power promotes the growth of compressive (002)-oriented films
and that such films can be used to make high quality factor MKIDs with $Q_{i}$
up to 600,000.
[2]
oai:arXiv.org:1911.06434 [pdf] - 2002490
Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance
Detectors
Zobrist, Nicholas;
Coiffard, Grégoire;
Bumble, Bruce;
Swimmer, Noah;
Steiger, Sarah;
Daal, Miguel;
Collura, Giulia;
Walter, Alex B.;
Bockstiegel, Clint;
Fruitwala, Neelay;
Lipartito, Isabel;
Mazin, Benjamin A.
Submitted: 2019-11-14
We report on the design and performance of Microwave Kinetic Inductance
Detectors (MKIDs) sensitive to single photons in the optical to near-infrared
range using hafnium as the sensor material. Our test device had a
superconducting transition temperature of 395 mK and a room temperature normal
state resistivity of 97 $\mu \Omega$ cm with an RRR = 1.6. Resonators on the
device displayed internal quality factors of around 200,000. Similar to the
analysis of MKIDs made from other highly resistive superconductors, we find
that modeling the temperature response of the detector requires an extra
broadening parameter in the superconducting density of states. Finally, we show
that this material and design is compatible with a full-array fabrication
process which resulted in pixels with decay times of about 40 $\mu$s and
resolving powers of ~9 at 800 nm.
[3]
oai:arXiv.org:1908.02775 [pdf] - 1931524
Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in
the 2020s
Mazin, Benjamin A.;
Bailey, Jeb;
Bartlett, Jo;
Bockstiegel, Clint;
Bumble, Bruce;
Coiffard, Gregoire;
Currie, Thayne;
Daal, Miguel;
Davis, Kristina;
Dodkins, Rupert;
Fruitwala, Neelay;
Jovanovic, Nemanja;
Lipartito, Isabel;
Lozi, Julien;
Males, Jared;
Mawet, Dimitri;
Meeker, Seth;
O'Brien, Kieran;
Rich, Michael;
Smith, Jenny;
Steiger, Sarah;
Swimmer, Noah;
Walter, Alex;
Zobrist, Nick;
Zmuidzinas, Jonas
Submitted: 2019-08-07
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are
superconducting photon counting detectors capable of measuring the energy and
arrival time of individual OIR photons without read noise or dark current. In
this whitepaper we will discuss the current status of OIR MKIDs and MKID-based
instruments.
[4]
oai:arXiv.org:1907.03078 [pdf] - 1922487
Wide-band Parametric Amplifier Readout and Resolution of Optical
Microwave Kinetic Inductance Detectors
Zobrist, Nicholas;
Eom, Byeong Ho;
Day, Peter;
Mazin, Benjamin A.;
Meeker, Seth R.;
Bumble, Bruce;
LeDuc, Henry G.;
Coiffard, Gérgoire;
Szypryt, Paul;
Fruitwala, Neelay;
Lipartito, Isabel;
Bockstiegel, Clint
Submitted: 2019-07-06
The energy resolution of a single photon counting Microwave Kinetic
Inductance Detector (MKID) can be degraded by noise coming from the primary low
temperature amplifier in the detector's readout system. Until recently, quantum
limited amplifiers have been incompatible with these detectors due to dynamic
range, power, and bandwidth constraints. However, we show that a kinetic
inductance based traveling wave parametric amplifier can be used for this
application and reaches the quantum limit. The total system noise for this
readout scheme was equal to ~2.1 in units of quanta. For incident photons in
the 800 to 1300 nm range, the amplifier increased the average resolving power
of the detector from ~6.7 to 9.3 at which point the resolution becomes limited
by noise on the pulse height of the signal. Noise measurements suggest that a
resolving power of up to 25 is possible if redesigned detectors can remove this
additional noise source.
[5]
oai:arXiv.org:1803.10420 [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field
Spectrograph for High-Contrast Astronomy
Meeker, Seth R.;
Mazin, Benjamin A.;
Walter, Alex B.;
Strader, Paschal;
Fruitwala, Neelay;
Bockstiegel, Clint;
Szypryt, Paul;
Ulbricht, Gerhard;
Coiffard, Gregoire;
Bumble, Bruce;
Cancelo, Gustavo;
Zmuda, Ted;
Treptow, Ken;
Wilcer, Neal;
Collura, Giulia;
Dodkins, Rupert;
Lipartito, Isabel;
Zobrist, Nicholas;
Bottom, Michael;
Shelton, J. Chris;
Mawet, Dimitri;
van Eyken, Julian C.;
Vasisht, Gautam;
Serabyn, Eugene
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving
Superconducting Spectrophotometer), the first of several planned integral field
spectrographs to use optical/near-infrared Microwave Kinetic Inductance
Detectors (MKIDs) for high-contrast imaging. The photon counting and
simultaneous low-resolution spectroscopy provided by MKIDs will enable
real-time speckle control techniques and post-processing speckle suppression at
framerates capable of resolving the atmospheric speckles that currently limit
high-contrast imaging from the ground. DARKNESS is now operational behind the
PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at
Palomar Observatory. Here we describe the motivation, design, and
characterization of the instrument, early on-sky results, and future prospects.
[6]
oai:arXiv.org:1710.07318 [pdf] - 1590047
Large-format platinum silicide microwave kinetic inductance detectors
for optical to near-IR astronomy
Szypryt, P.;
Meeker, S. R.;
Coiffard, G.;
Fruitwala, N.;
Bumble, B.;
Ulbricht, G.;
Walter, A. B.;
Daal, M.;
Bockstiegel, C.;
Collura, G.;
Zobrist, N.;
Lipartito, I.;
Mazin, B. A.
Submitted: 2017-10-19
We have fabricated and characterized 10,000 and 20,440 pixel Microwave
Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR
Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID
Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive
optics systems with the goal of directly imaging exoplanets in a 800-1400 nm
band. Previous large optical and near-IR MKID arrays were fabricated using
substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays,
however, suffered from severe non-uniformities in the TiN critical temperature,
causing resonances to shift away from their designed values and lowering usable
detector yield. We have begun fabricating DARKNESS and MEC arrays using
platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays
have much higher uniformity than the TiN arrays, resulting in higher pixel
yields, they have demonstrated better spectral resolution than TiN MKIDs of
similar design. PtSi MKIDs also do not display the hot pixel effects seen when
illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1
um.
[7]
oai:arXiv.org:1610.00725 [pdf] - 1496313
High Quality Factor Platinum Silicide Microwave Kinetic Inductance
Detectors
Submitted: 2016-10-03
We report on the development of Microwave Kinetic Inductance Detectors
(MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging
superconducting detector technology, capable of measuring the arrival times of
single photons to better than two microseconds and their energies to around ten
percent. Previously, MKIDs have been fabricated using either sub-stoichiometric
titanium nitride or aluminum, but TiN suffers from spatial inhomogeneities in
the superconducting critical temperature and Al has a low kinetic inductance
fraction, causing low detector sensitivity. To address these issues, we have
instead fabricated PtSi microresonators with superconducting critical
temperatures of 944$\pm$12~mK and high internal quality factors ($Q_i \gtrsim
10^6$). These devices show typical quasiparticle lifetimes of $\tau_{qp}
\approx 30$--$40~\mu$s and spectral resolution, $R = \lambda / \Delta \lambda$,
of 8 at 406.6~nm. We compare PtSi MKIDs to those fabricated with TiN and detail
the substantial advantages that PtSi MKIDs have to offer.
[8]
oai:arXiv.org:1603.05270 [pdf] - 1385546
Search for Optical Pulsations in PSR J0337+1715
Strader, M. J.;
Archibald, A. M.;
Meeker, S. R.;
Szypryt, P.;
Walter, A. B.;
van Eyken, J. C.;
Ulbricht, G.;
Stoughton, C.;
Bumble, B.;
Kaplan, D. L.;
Mazin, B. A.
Submitted: 2016-03-16
We report on a search for optical pulsations from PSR J0337+1715 at its
observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms
spin period) in a triple hierarchical system with two white dwarfs, and has a
known optical counterpart with g-band magnitude 18. The observations were done
with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the
200" Hale telescope at Palomar Observatory. No significant pulsations were
found in the range 4000-11000 angstroms, and we can limit pulsed emission in
g-band to be fainter than 25 mag.
[9]
oai:arXiv.org:1506.07537 [pdf] - 1237882
Highly Multiplexible Thermal Kinetic Inductance Detectors for X-Ray
Imaging Spectroscopy
Submitted: 2015-06-24
For X-ray imaging spectroscopy, high spatial resolution over a large field of
view is often as important as high energy resolution, but current X-ray
detectors do not provide both in the same device. Thermal Kinetic Inductance
Detectors (TKIDs) are being developed as they offer a feasible way to combine
the energy resolution of transition edge sensors with pixel counts approaching
CCDs and thus promise significant improvements for many X-ray spectroscopy
applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors
(MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels
have recently been demonstrated and much bigger arrays are under development.
In this work, we present our first working TKID prototypes which are able to
achieve an energy resolution of 75 eV at 5.9 keV, even though their general
design still has to be optimized. We further describe TKID fabrication,
characterization, multiplexing and working principle and demonstrate the
necessity of a data fitting algorithm in order to extract photon energies. With
further design optimizations we expect to be able to improve our TKID energy
resolution to less than 10 eV at 5.9 keV.
[10]
oai:arXiv.org:1402.1223 [pdf] - 1515677
Performance of the Caltech Submillimeter Observatory Dual-Color 180-720
GHz Balanced SIS Receivers
Kooi, J. W.;
Chamberlin, R. A.;
Monje, R.;
Kovacs, A.;
Rice, F.;
Yoshida, H.;
Force, B.;
Cooper, K.;
Miller, D.;
Gould, M.;
Lis, D.;
Bumble, B.;
LeDuc, R.;
Stern, J. A.;
Phillips, T. G.
Submitted: 2014-02-05
We report on balanced SIS receivers covering the astronomical important
180-720 GHz submillimeter atmospheric window. To facilitate remote observations
and automated spectral line surveys, fully synthesized local oscillators are
employed. High-current-density Nb-AlN-Nb
superconducting-insulating-superconducting (SIS) tunnel junctions are used as
the mixing element. The measured double-sideband (DSB) 230 GHz receiver noise
temperature, uncorrected for optics loss, ranges from 50K at 185 GHz, 33K at
246 GHz, to 51K at 280 GHz. In this frequency range the mixer has a DSB
conversion gain of 0 +- 1.5 dB. The measured 460 GHz double-sideband receiver
noise temperature, uncorrected for optics loss, is 32K at 400 GHz, 34K at 460
GHz, and 61K at 520 GHz. Similar to the 230 GHz balanced mixer, the DSB mixer
conversion gain is 1 +- 1 dB. To help optimize performance, the mixer IF
circuits and bias injection are entirely planar by design. Dual-frequency
observation, by means of separating the incoming circular polarized electric
field into two orthogonal components, is another important mode of operation
offered by the new facility instrumentation. Instrumental stability is
excellent supporting the LO noise cancellation properties of the balanced mixer
configuration. In the spring of 2012 the dual-frequency 230/460 SIS receiver
was successfully installed at Caltech Submillimeter Observatory (CSO), Mauna
Kea, HI.
[11]
oai:arXiv.org:1309.3270 [pdf] - 785198
Excess Optical Enhancement Observed with ARCONS for Early Crab Giant
Pulses
Strader, M. J.;
Johnson, M. D.;
Mazin, B. A.;
Jaeger, G. V. Spiro;
Gwinn, C. R.;
Meeker, S. R.;
Szypryt, P.;
van Eyken, J. C.;
Marsden, D.;
O'Brien, K.;
Walter, A. B.;
Ulbricht, G.;
Stoughton, C.;
Bumble, B.
Submitted: 2013-09-12, last modified: 2013-11-08
We observe an extraordinary link in the Crab pulsar between the enhancement
of an optical pulse and the timing of the corresponding giant radio pulse. At
optical through infrared wavelengths, our observations use the high time
resolution of ARCONS, a unique superconducting energy-resolving photon-counting
array at the Palomar 200-inch telescope. At radio wavelengths, we observe with
the Robert C. Byrd Green Bank Telescope and the GUPPI backend. We see an
$11.3\pm2.5\%$ increase in peak optical flux for pulses that have an
accompanying giant radio pulse arriving near the peak of the optical main
pulse, in contrast to a $3.2\pm0.5\%$ increase when an accompanying giant radio
pulse arrives soon after the optical peak. We also observe that the peak of the
optical main pulse is $2.8\pm0.8\%$ enhanced when there is a giant radio pulse
accompanying the optical interpulse. We observe no statistically significant
spectral differences between optical pulses accompanied by and not accompanied
by giant radio pulses. Our results extend previous observations of
optical-radio correlation to the time and spectral domains. Our refined
temporal correlation suggests that optical and radio emission are indeed
causally linked, and the lack of spectral differences suggests that the same
mechanism is responsible for all optical emission.
[12]
oai:arXiv.org:1309.4087 [pdf] - 785202
Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS
Szypryt, P.;
Duggan, G. E.;
Mazin, B. A.;
Meeker, S. R.;
Strader, M. J.;
van Eyken, J. C.;
Marsden, D.;
O'Brien, K.;
Walter, A. B.;
Ulbricht, G.;
Prince, T. A.;
Stoughton, C.;
Bumble, B.
Submitted: 2013-09-16
AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short
period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of
particular interest as it is the first observed eclipsing AM CVn system. We
observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for
\textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the
Palomar 200" telescope. ARCONS uses a relatively new type of energy-resolved
photon counters called Microwave Kinetic Inductance Detectors (MKIDs). ARCONS,
sensitive to radiation from 350 to 1100 nm, has a time resolution of several
microseconds and can measure the energy of a photon to $\sim10%$. We present
the light curves for these observations and examine changes in orbital period
from prior observations. Using a quadratic ephemeris model, we measure a period
rate of change $\dot{P} = (3.07 \pm 0.56)\times 10^{-13}$. In addition, we use
the high timing resolution of ARCONS to examine the system's high frequency
variations and search for possible quasi-periodic oscillations (QPOs). Finally,
we use the instrument's spectral resolution to examine the light curves in
various wavelength bands. We do not find any high frequency QPOs or significant
spectral variability throughout an eclipse.
[13]
oai:arXiv.org:1306.4674 [pdf] - 1172164
ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging
Spectrophotometer
Mazin, B. A.;
Meeker, S. R.;
Strader, M. J.;
Bumble, B.;
O'Brien, K.;
Szypryt, P.;
Marsden, D.;
van Eyken, J. C.;
Duggan, G. E.;
Ulbricht, G.;
Stoughton, C.;
Johnson, M.
Submitted: 2013-06-19
We present the design, construction, and commissioning results of ARCONS, the
Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first
ground-based instrument in the optical through near-IR wavelength range based
on Microwave Kinetic Inductance Detectors (MKIDs). MKIDs are revolutionary
cryogenic detectors, capable of detecting single photons and measuring their
energy without filters or gratings, similar to an X-ray microcalorimeter. MKIDs
are nearly ideal, noiseless photon detectors, as they do not suffer from read
noise or dark current and have nearly perfect cosmic ray rejection. ARCONS is
an Integral Field Spectrograph (IFS) containing a lens-coupled 2024 pixel MKID
array yielding a 20"x20" field of view, and has been deployed on the Palomar
200" and Lick 120" telescopes for 24 nights of observing. We present initial
results showing that ARCONS and its MKID arrays are now a fully operational and
powerful tool for astronomical observations.
[14]
oai:arXiv.org:1203.4549 [pdf] - 523058
Position and energy-resolved particle detection using phonon-mediated
microwave kinetic inductance detectors
Submitted: 2012-03-20, last modified: 2012-06-10
We demonstrate position and energy-resolved phonon-mediated detection of
particle interactions in a silicon substrate instrumented with an array of
microwave kinetic inductance detectors (MKIDs). The relative magnitude and
delay of the signal received in each sensor allows the location of the
interaction to be determined with < 1 mm precision at 30 keV. Using this
position information, variations in the detector response with position can be
removed, and an energy resolution of \sigma_E = 0.55 keV at 30 keV was
measured. Since MKIDs can be fabricated from a single deposited film and are
naturally multiplexed in the frequency domain, this technology can be extended
to provide highly-pixelized athermal phonon sensors for ~1 kg scale detector
elements. Such high-resolution, massive particle detectors would be applicable
to next-generation rare-event searches such as the direct detection of dark
matter, neutrinoless double-beta decay, or coherent neutrino-nucleus
scattering.
[15]
oai:arXiv.org:1201.5904 [pdf] - 1093317
ARCONS: a highly multiplexed superconducting UV to near-IR camera
Submitted: 2012-01-27
ARCONS, the Array Camera for Optical to Near-infrared Spectrophotometry, was
recently commissioned at the Coude focus of the 200-inch Hale Telescope at the
Palomar Observatory. At the heart of this unique instrument is a 1024-pixel
Microwave Kinetic Inductance Detector (MKID), exploiting the Kinetic Inductance
effect to measure the energy of the incoming photon to better than several
percent. The ground-breaking instrument is lens-coupled with a pixel scale of
0.23"/pixel, with each pixel recording the arrival time (<2 microsec) and
energy of a photon (~10%) in the optical to near-IR (0.4-1.1 microns) range.
The scientific objectives of the instrument include the rapid follow-up and
classification of the transient phenomena.
[16]
oai:arXiv.org:1112.0004 [pdf] - 471685
A superconducting focal plane array for ultraviolet, optical, and
near-infrared astrophysics
Submitted: 2011-11-30
Microwave Kinetic Inductance Detectors, or MKIDs, have proven to be a
powerful cryogenic detector technology due to their sensitivity and the ease
with which they can be multiplexed into large arrays. A MKID is an energy
sensor based on a photon-variable superconducting inductance in a lithographed
microresonator, and is capable of functioning as a photon detector across the
electromagnetic spectrum as well as a particle detector. Here we describe the
first successful effort to create a photon-counting, energy-resolving
ultraviolet, optical, and near infrared MKID focal plane array. These new
Optical Lumped Element (OLE) MKID arrays have significant advantages over
semiconductor detectors like charge coupled devices (CCDs). They can count
individual photons with essentially no false counts and determine the energy
and arrival time of every photon with good quantum efficiency. Their physical
pixel size and maximum count rate is well matched with large telescopes. These
capabilities enable powerful new astrophysical instruments usable from the
ground and space. MKIDs could eventually supplant semiconductor detectors for
most astronomical instrumentation, and will be useful for other disciplines
such as quantum optics and biological imaging.
[17]
oai:arXiv.org:1007.4564 [pdf] - 1033929
Herschel observations of EXtra-Ordinary Sources: The Terahertz spectrum
of Orion KL seen at high spectral resolution
Crockett, N. R.;
Bergin, E. A.;
Wang, S.;
Lis, D. C.;
Bell, T. A.;
Blake, G. A.;
Boogert, A.;
Bumble, B.;
Cabrit, S.;
Caux, E.;
Ceccarelli, C.;
Cernicharo, J.;
Comito, C.;
Daniel, F.;
Dubernet, M. -L.;
Emprechtinger, M.;
Encrenaz, P.;
Falgarone, E.;
Gerin, M.;
Giesen, T. F.;
Goicoechea, J. R.;
Goldsmith, P. F.;
Gupta, H.;
Gusten, R.;
Hartogh, P.;
Helmich, F.;
Herbst, E.;
Honingh, N.;
Joblin, C.;
Johnstone, D.;
Karpov, A.;
Kawamura, J. H.;
Kooi, J.;
Krieg, J. -M.;
Langer, W. D.;
Latter, W. D.;
Lord, S. D.;
Maret, S.;
Martin, P. G.;
Melnick, G. J.;
Menten, K. M.;
Morris, P.;
Muller, H. S. P.;
Murphy, J. A.;
Neufeld, D. A.;
Ossenkopf, V.;
Pearson, J. C.;
Perault, M.;
Phillips, T. G.;
Plume, R.;
Qin, S. -L.;
Roelfsema, P.;
Schieder, R.;
Schilke, P.;
Schlemmer, S.;
Stutzki, J.;
van der Tak, F. F. S.;
Tielens, A.;
Trappe, N.;
Vastel, C.;
Yorke, H. W.;
Yu, S.;
Zmuidzinas, J.
Submitted: 2010-07-26
We present the first high spectral resolution observations of Orion KL in the
frequency ranges 1573.4 - 1702.8 GHz (band 6b) and 1788.4 - 1906.8 GHz (band
7b) obtained using the HIFI instrument on board the Herschel Space Observatory.
We characterize the main emission lines found in the spectrum, which primarily
arise from a range of components associated with Orion KL including the hot
core, but also see widespread emission from components associated with
molecular outflows traced by H2O, SO2, and OH. We find that the density of
observed emission lines is significantly diminished in these bands compared to
lower frequency Herschel/HIFI bands.
[18]
oai:arXiv.org:1007.2172 [pdf] - 1033661
Herschel observations of EXtra-Ordinary Sources: the present and future
of spectral surveys with Herschel/HIFI
Bergin, E. A.;
Phillips, T. G.;
Comito, C.;
Crockett, N. R.;
Lis, D. C.;
Schilke, P.;
Wang, S.;
Bell, T. A.;
Blake, G. A.;
Bumble, B.;
Caux, E.;
Cabrit, S.;
Ceccarelli, C.;
Cernicharo, J.;
Daniel, F.;
de Graauw, Th.;
Dubernet, M. -L.;
Emprechtinger, M.;
Encrenaz, P.;
Falgarone, E.;
Gerin, M.;
Giesen, T. F.;
Goicoechea, J. R.;
Goldsmith, P. F.;
Gupta, H.;
Hartogh, P.;
Helmich, F. P.;
Herbst, E.;
Joblin, C.;
Johnstone, D.;
Kawamura, J. H.;
Langer, W. D.;
Latter, W. B.;
Lord, S. D.;
Maret, S.;
Martin, P. G.;
Melnick, G. J.;
Menten, K. M.;
Morris, P.;
Muller, H. S. P.;
Murphy, J. A.;
Neufeld, D. A.;
Ossenkopf, V.;
Pagani, L.;
Pearson, J. C.;
Perault, M.;
Plume, R.;
Roelfsema, P.;
Qin, S. -L.;
Salez, M.;
Schlemmer, S.;
Stutzki, J.;
Tielens, A. G. G. M.;
Trappe, N.;
van der Tak, F. F. S.;
Vastel, C.;
Yorke, H. W.;
Yu, S.;
Zmuidzinas, J.
Submitted: 2010-07-13
We present initial results from the Herschel GT key program: Herschel
observations of EXtra-Ordinary Sources (HEXOS) and outline the promise and
potential of spectral surveys with Herschel/HIFI. The HIFI instrument offers
unprecedented sensitivity, as well as continuous spectral coverage across the
gaps imposed by the atmosphere, opening up a largely unexplored wavelength
regime to high-resolution spectroscopy. We show the spectrum of Orion KL
between 480 and 560 GHz and from 1.06 to 1.115 THz. From these data, we confirm
that HIFI separately measures the dust continuum and spectrally resolves
emission lines in Orion KL. Based on this capability we demonstrate that the
line contribution to the broad-band continuum in this molecule-rich source is
~20-40% below 1 THz and declines to a few percent at higher frequencies. We
also tentatively identify multiple transitions of HD18O in the spectra. The
first detection of this rare isotopologue in the interstellar medium suggests
that HDO emission is optically thick in the Orion hot core with HDO/H2O ~ 0.02.
We discuss the implications of this detection for the water D/H ratio in hot
cores.
[19]
oai:arXiv.org:1007.0752 [pdf] - 1033500
ARCONS: A highly multiplexed superconducting optical to near-IR camera
Submitted: 2010-07-05
We report on the development of ARCONS, the ARray Camera for Optical to
Near-IR Spectrophotometry. This photon counting integral field unit (IFU),
being built at UCSB and Caltech with detectors fabricated at JPL, will use a
unique, highly multiplexed low temperature detector technology known as
Microwave Kinetic Inductance Detectors (MKIDs). These detectors, which operate
at 100 mK, should provide photon counting with energy resolution of R =
E/{\delta}E > 20 and time resolution of a microsecond, with a quantum
efficiency of around 50%. We expect to field the instrument at the Palomar 200"
telescope in the first quarter of 2011 with an array containing 1024 pixels in
a 32x32 pixel form factor to yield a field of view of approximately 10x10
arcseconds. The bandwidth of the camera is limited by the rising sky count rate
at longer wavelengths, but we anticipate a bandwidth of 0.35 to 1.35 {\mu}m
will be achievable. A simple optical path and compact dewar utilizing a
cryogen-free adiabatic demagnetization refridgerator (ADR) allows the camera to
be deployed quickly at Naysmith or Coude foci at a variety of telescopes. A
highly expandable software defined radio (SDR) readout that can scale up to
much larger arrays has been developed.
[20]
oai:arXiv.org:1005.2517 [pdf] - 1032472
HIFI observations of warm gas in DR21: Shock versus radiative heating
Ossenkopf, V.;
Röllig, M.;
Simon, R.;
Schneider, N.;
Okada, Y.;
Stutzki, J.;
Gerin, M.;
Akyilmaz, M.;
Beintema, D.;
Benz, A. O.;
Berne, O.;
Boulanger, F.;
Bumble, B.;
Coeur-Joly, O.;
Dedes, C.;
Diez-Gonzalez, M. C.;
France, K.;
Fuente, A.;
Gallego, J. D.;
Goicoechea, J. R.;
Güsten, R.;
Harris, A.;
Higgins, R.;
Jackson, B.;
Jarchow, C.;
Joblin, C.;
Klein, T.;
Kramer, C.;
Lord, S.;
Martin, P.;
Martin-Pintado, J.;
Mookerjea, B.;
Neufeld, D. A.;
Phillips, T.;
Rizzo, J. R.;
van der Tak, F. F. S.;
Teyssier, D.;
Yorke, H.
Submitted: 2010-05-14
The molecular gas in the DR21 massive star formation region is known to be
affected by the strong UV field from the central star cluster and by a fast
outflow creating a bright shock. The relative contribution of both heating
mechanisms is the matter of a long debate. By better sampling the excitation
ladder of various tracers we provide a quantitative distinction between the
different heating mechanisms. HIFI observations of mid-J transitions of CO and
HCO+ isotopes allow us to bridge the gap in excitation energies between
observations from the ground, characterizing the cooler gas, and existing ISO
LWS spectra, constraining the properties of the hot gas. Comparing the detailed
line profiles allows to identify the physical structure of the different
components. In spite of the known shock-excitation of H2 and the clearly
visible strong outflow, we find that the emission of all lines up to > 2 THz
can be explained by purely radiative heating of the material. However, the new
Herschel/HIFI observations reveal two types of excitation conditions. We find
hot and dense clumps close to the central cluster, probably dynamically
affected by the outflow, and a more widespread distribution of cooler, but
nevertheless dense, molecular clumps.
[21]
oai:arXiv.org:cond-mat/0610130 [pdf] - 110417
A Position Sensitive X-ray Spectrophotometer using Microwave Kinetic
Inductance Detectors
Submitted: 2006-10-04
The surface impedance of a superconductor changes when energy is absorbed and
Cooper pairs are broken to produce single electron (quasiparticle) excitations.
This change may be sensitively measured using a thin-film resonant circuit
called a microwave kinetic inductance detector (MKID). The practical
application of MKIDs for photon detection requires a method of efficiently
coupling the photon energy to the MKID. We present results on position
sensitive X-ray detectors made by using two aluminum MKIDs on either side of a
tantalum photon absorber strip. Diffusion constants, recombination times, and
energy resolution are reported. MKIDs can easily be scaled into large arrays.