sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Bumble, Bruce

Normalized to: Bumble, B.

21 article(s) in total. 158 co-authors, from 1 to 16 common article(s). Median position in authors list is 6,0.

[1]  oai:arXiv.org:2004.00736  [pdf] - 2085203
Characterization of sputtered hafnium thin films for high quality factor microwave kinetic inductance detectors
Comments: 9 pages, 8 figures, 1 table. Submitted to SUST
Submitted: 2020-04-01
Hafnium is an elemental superconductor which crystallizes in a hexagonal close packed structure, has a transition temperature $T_{C} \simeq 400 mK$, and has a high normal state resistivity around $90 \mu \Omega. cm$. In Microwave Kinetic Inductance Detectors (MKIDs), these properties are advantageous since they allow for creating detectors sensitive to optical and near infra-red radiation. In this work, we study how sputter conditions and especially the power applied to the target during the deposition, affect the hafnium $T_{C}$, resistivity, stress, texture and preferred crystal orientation. We find that the position of the target with respect to the substrate strongly affects the orientation of the crystallites in the films and the internal quality factor, $Q_{i}$, of MKIDs fabricated from the films. In particular, we demonstrate that a DC magnetron sputter deposition at a normal angle of incidence, low pressure, and low plasma power promotes the growth of compressive (002)-oriented films and that such films can be used to make high quality factor MKIDs with $Q_{i}$ up to 600,000.
[2]  oai:arXiv.org:1911.06434  [pdf] - 2002490
Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance Detectors
Comments:
Submitted: 2019-11-14
We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 $\mu \Omega$ cm with an RRR = 1.6. Resonators on the device displayed internal quality factors of around 200,000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process which resulted in pixels with decay times of about 40 $\mu$s and resolving powers of ~9 at 800 nm.
[3]  oai:arXiv.org:1908.02775  [pdf] - 1931524
Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in the 2020s
Comments: Astro2020 APC Whitepaper. 16 pages, 10 figures
Submitted: 2019-08-07
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are superconducting photon counting detectors capable of measuring the energy and arrival time of individual OIR photons without read noise or dark current. In this whitepaper we will discuss the current status of OIR MKIDs and MKID-based instruments.
[4]  oai:arXiv.org:1907.03078  [pdf] - 1922487
Wide-band Parametric Amplifier Readout and Resolution of Optical Microwave Kinetic Inductance Detectors
Comments:
Submitted: 2019-07-06
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based traveling wave parametric amplifier can be used for this application and reaches the quantum limit. The total system noise for this readout scheme was equal to ~2.1 in units of quanta. For incident photons in the 800 to 1300 nm range, the amplifier increased the average resolving power of the detector from ~6.7 to 9.3 at which point the resolution becomes limited by noise on the pulse height of the signal. Noise measurements suggest that a resolving power of up to 25 is possible if redesigned detectors can remove this additional noise source.
[5]  oai:arXiv.org:1803.10420  [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-Contrast Astronomy
Comments: 17 pages, 17 figures. PASP Published
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques and post-processing speckle suppression at framerates capable of resolving the atmospheric speckles that currently limit high-contrast imaging from the ground. DARKNESS is now operational behind the PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at Palomar Observatory. Here we describe the motivation, design, and characterization of the instrument, early on-sky results, and future prospects.
[6]  oai:arXiv.org:1710.07318  [pdf] - 1590047
Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy
Comments: 16 pages, 8 figures, published in Optics Express
Submitted: 2017-10-19
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800-1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperature, causing resonances to shift away from their designed values and lowering usable detector yield. We have begun fabricating DARKNESS and MEC arrays using platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays have much higher uniformity than the TiN arrays, resulting in higher pixel yields, they have demonstrated better spectral resolution than TiN MKIDs of similar design. PtSi MKIDs also do not display the hot pixel effects seen when illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1 um.
[7]  oai:arXiv.org:1610.00725  [pdf] - 1496313
High Quality Factor Platinum Silicide Microwave Kinetic Inductance Detectors
Comments: 5 pages, 5 figures, accepted by APL
Submitted: 2016-10-03
We report on the development of Microwave Kinetic Inductance Detectors (MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging superconducting detector technology, capable of measuring the arrival times of single photons to better than two microseconds and their energies to around ten percent. Previously, MKIDs have been fabricated using either sub-stoichiometric titanium nitride or aluminum, but TiN suffers from spatial inhomogeneities in the superconducting critical temperature and Al has a low kinetic inductance fraction, causing low detector sensitivity. To address these issues, we have instead fabricated PtSi microresonators with superconducting critical temperatures of 944$\pm$12~mK and high internal quality factors ($Q_i \gtrsim 10^6$). These devices show typical quasiparticle lifetimes of $\tau_{qp} \approx 30$--$40~\mu$s and spectral resolution, $R = \lambda / \Delta \lambda$, of 8 at 406.6~nm. We compare PtSi MKIDs to those fabricated with TiN and detail the substantial advantages that PtSi MKIDs have to offer.
[8]  oai:arXiv.org:1603.05270  [pdf] - 1385546
Search for Optical Pulsations in PSR J0337+1715
Comments: 4 pages, 2 figures, accepted to MNRAS
Submitted: 2016-03-16
We report on a search for optical pulsations from PSR J0337+1715 at its observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms spin period) in a triple hierarchical system with two white dwarfs, and has a known optical counterpart with g-band magnitude 18. The observations were done with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the 200" Hale telescope at Palomar Observatory. No significant pulsations were found in the range 4000-11000 angstroms, and we can limit pulsed emission in g-band to be fainter than 25 mag.
[9]  oai:arXiv.org:1506.07537  [pdf] - 1237882
Highly Multiplexible Thermal Kinetic Inductance Detectors for X-Ray Imaging Spectroscopy
Comments: 7 pages, 4 figures, accepted for publication in Applied Physics Letters
Submitted: 2015-06-24
For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus promise significant improvements for many X-ray spectroscopy applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors (MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels have recently been demonstrated and much bigger arrays are under development. In this work, we present our first working TKID prototypes which are able to achieve an energy resolution of 75 eV at 5.9 keV, even though their general design still has to be optimized. We further describe TKID fabrication, characterization, multiplexing and working principle and demonstrate the necessity of a data fitting algorithm in order to extract photon energies. With further design optimizations we expect to be able to improve our TKID energy resolution to less than 10 eV at 5.9 keV.
[10]  oai:arXiv.org:1402.1223  [pdf] - 1515677
Performance of the Caltech Submillimeter Observatory Dual-Color 180-720 GHz Balanced SIS Receivers
Comments: Accepted for publication in IEEE/TST
Submitted: 2014-02-05
We report on balanced SIS receivers covering the astronomical important 180-720 GHz submillimeter atmospheric window. To facilitate remote observations and automated spectral line surveys, fully synthesized local oscillators are employed. High-current-density Nb-AlN-Nb superconducting-insulating-superconducting (SIS) tunnel junctions are used as the mixing element. The measured double-sideband (DSB) 230 GHz receiver noise temperature, uncorrected for optics loss, ranges from 50K at 185 GHz, 33K at 246 GHz, to 51K at 280 GHz. In this frequency range the mixer has a DSB conversion gain of 0 +- 1.5 dB. The measured 460 GHz double-sideband receiver noise temperature, uncorrected for optics loss, is 32K at 400 GHz, 34K at 460 GHz, and 61K at 520 GHz. Similar to the 230 GHz balanced mixer, the DSB mixer conversion gain is 1 +- 1 dB. To help optimize performance, the mixer IF circuits and bias injection are entirely planar by design. Dual-frequency observation, by means of separating the incoming circular polarized electric field into two orthogonal components, is another important mode of operation offered by the new facility instrumentation. Instrumental stability is excellent supporting the LO noise cancellation properties of the balanced mixer configuration. In the spring of 2012 the dual-frequency 230/460 SIS receiver was successfully installed at Caltech Submillimeter Observatory (CSO), Mauna Kea, HI.
[11]  oai:arXiv.org:1309.3270  [pdf] - 785198
Excess Optical Enhancement Observed with ARCONS for Early Crab Giant Pulses
Comments: 5 pages, 5 figures. Updated to match revised version, accepted to ApJL Nov 7, 2013. Several additions and improved DM in timing solution
Submitted: 2013-09-12, last modified: 2013-11-08
We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARCONS, a unique superconducting energy-resolving photon-counting array at the Palomar 200-inch telescope. At radio wavelengths, we observe with the Robert C. Byrd Green Bank Telescope and the GUPPI backend. We see an $11.3\pm2.5\%$ increase in peak optical flux for pulses that have an accompanying giant radio pulse arriving near the peak of the optical main pulse, in contrast to a $3.2\pm0.5\%$ increase when an accompanying giant radio pulse arrives soon after the optical peak. We also observe that the peak of the optical main pulse is $2.8\pm0.8\%$ enhanced when there is a giant radio pulse accompanying the optical interpulse. We observe no statistically significant spectral differences between optical pulses accompanied by and not accompanied by giant radio pulses. Our results extend previous observations of optical-radio correlation to the time and spectral domains. Our refined temporal correlation suggests that optical and radio emission are indeed causally linked, and the lack of spectral differences suggests that the same mechanism is responsible for all optical emission.
[12]  oai:arXiv.org:1309.4087  [pdf] - 785202
Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS
Comments: 8 pages, 7 figures, submitted to MNRAS
Submitted: 2013-09-16
AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of particular interest as it is the first observed eclipsing AM CVn system. We observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for \textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the Palomar 200" telescope. ARCONS uses a relatively new type of energy-resolved photon counters called Microwave Kinetic Inductance Detectors (MKIDs). ARCONS, sensitive to radiation from 350 to 1100 nm, has a time resolution of several microseconds and can measure the energy of a photon to $\sim10%$. We present the light curves for these observations and examine changes in orbital period from prior observations. Using a quadratic ephemeris model, we measure a period rate of change $\dot{P} = (3.07 \pm 0.56)\times 10^{-13}$. In addition, we use the high timing resolution of ARCONS to examine the system's high frequency variations and search for possible quasi-periodic oscillations (QPOs). Finally, we use the instrument's spectral resolution to examine the light curves in various wavelength bands. We do not find any high frequency QPOs or significant spectral variability throughout an eclipse.
[13]  oai:arXiv.org:1306.4674  [pdf] - 1172164
ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging Spectrophotometer
Comments: 12 pages, 16 figures, submitted to PASP
Submitted: 2013-06-19
We present the design, construction, and commissioning results of ARCONS, the Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first ground-based instrument in the optical through near-IR wavelength range based on Microwave Kinetic Inductance Detectors (MKIDs). MKIDs are revolutionary cryogenic detectors, capable of detecting single photons and measuring their energy without filters or gratings, similar to an X-ray microcalorimeter. MKIDs are nearly ideal, noiseless photon detectors, as they do not suffer from read noise or dark current and have nearly perfect cosmic ray rejection. ARCONS is an Integral Field Spectrograph (IFS) containing a lens-coupled 2024 pixel MKID array yielding a 20"x20" field of view, and has been deployed on the Palomar 200" and Lick 120" telescopes for 24 nights of observing. We present initial results showing that ARCONS and its MKID arrays are now a fully operational and powerful tool for astronomical observations.
[14]  oai:arXiv.org:1203.4549  [pdf] - 523058
Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors
Comments: 4 pages, 4 figures
Submitted: 2012-03-20, last modified: 2012-06-10
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allows the location of the interaction to be determined with < 1 mm precision at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of \sigma_E = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly-pixelized athermal phonon sensors for ~1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to next-generation rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering.
[15]  oai:arXiv.org:1201.5904  [pdf] - 1093317
ARCONS: a highly multiplexed superconducting UV to near-IR camera
Comments: To appear in the proceedings of IAU symposium number 285; New Horizons in Time Domain Astronomy, eds. R.E.M Griffin, R. J. Hanisch & R. Seaman
Submitted: 2012-01-27
ARCONS, the Array Camera for Optical to Near-infrared Spectrophotometry, was recently commissioned at the Coude focus of the 200-inch Hale Telescope at the Palomar Observatory. At the heart of this unique instrument is a 1024-pixel Microwave Kinetic Inductance Detector (MKID), exploiting the Kinetic Inductance effect to measure the energy of the incoming photon to better than several percent. The ground-breaking instrument is lens-coupled with a pixel scale of 0.23"/pixel, with each pixel recording the arrival time (<2 microsec) and energy of a photon (~10%) in the optical to near-IR (0.4-1.1 microns) range. The scientific objectives of the instrument include the rapid follow-up and classification of the transient phenomena.
[16]  oai:arXiv.org:1112.0004  [pdf] - 471685
A superconducting focal plane array for ultraviolet, optical, and near-infrared astrophysics
Comments: 9 pages, 5 figures, accepted for publication in Optics Express
Submitted: 2011-11-30
Microwave Kinetic Inductance Detectors, or MKIDs, have proven to be a powerful cryogenic detector technology due to their sensitivity and the ease with which they can be multiplexed into large arrays. A MKID is an energy sensor based on a photon-variable superconducting inductance in a lithographed microresonator, and is capable of functioning as a photon detector across the electromagnetic spectrum as well as a particle detector. Here we describe the first successful effort to create a photon-counting, energy-resolving ultraviolet, optical, and near infrared MKID focal plane array. These new Optical Lumped Element (OLE) MKID arrays have significant advantages over semiconductor detectors like charge coupled devices (CCDs). They can count individual photons with essentially no false counts and determine the energy and arrival time of every photon with good quantum efficiency. Their physical pixel size and maximum count rate is well matched with large telescopes. These capabilities enable powerful new astrophysical instruments usable from the ground and space. MKIDs could eventually supplant semiconductor detectors for most astronomical instrumentation, and will be useful for other disciplines such as quantum optics and biological imaging.
[17]  oai:arXiv.org:1007.4564  [pdf] - 1033929
Herschel observations of EXtra-Ordinary Sources: The Terahertz spectrum of Orion KL seen at high spectral resolution
Comments: Accepted for publication in the Herschel HIFI special issue of Astronomy and Astrophysics Letters, 5 pages, 3 figures
Submitted: 2010-07-26
We present the first high spectral resolution observations of Orion KL in the frequency ranges 1573.4 - 1702.8 GHz (band 6b) and 1788.4 - 1906.8 GHz (band 7b) obtained using the HIFI instrument on board the Herschel Space Observatory. We characterize the main emission lines found in the spectrum, which primarily arise from a range of components associated with Orion KL including the hot core, but also see widespread emission from components associated with molecular outflows traced by H2O, SO2, and OH. We find that the density of observed emission lines is significantly diminished in these bands compared to lower frequency Herschel/HIFI bands.
[18]  oai:arXiv.org:1007.2172  [pdf] - 1033661
Herschel observations of EXtra-Ordinary Sources: the present and future of spectral surveys with Herschel/HIFI
Comments: 6 pages, 5 figures, accepted and to be published in Herschel HIFI special issue of A&A Letters
Submitted: 2010-07-13
We present initial results from the Herschel GT key program: Herschel observations of EXtra-Ordinary Sources (HEXOS) and outline the promise and potential of spectral surveys with Herschel/HIFI. The HIFI instrument offers unprecedented sensitivity, as well as continuous spectral coverage across the gaps imposed by the atmosphere, opening up a largely unexplored wavelength regime to high-resolution spectroscopy. We show the spectrum of Orion KL between 480 and 560 GHz and from 1.06 to 1.115 THz. From these data, we confirm that HIFI separately measures the dust continuum and spectrally resolves emission lines in Orion KL. Based on this capability we demonstrate that the line contribution to the broad-band continuum in this molecule-rich source is ~20-40% below 1 THz and declines to a few percent at higher frequencies. We also tentatively identify multiple transitions of HD18O in the spectra. The first detection of this rare isotopologue in the interstellar medium suggests that HDO emission is optically thick in the Orion hot core with HDO/H2O ~ 0.02. We discuss the implications of this detection for the water D/H ratio in hot cores.
[19]  oai:arXiv.org:1007.0752  [pdf] - 1033500
ARCONS: A highly multiplexed superconducting optical to near-IR camera
Comments: 10 pages, 5 figures. To appear in Proc. SPIE Astronomical Telescopes and Instrumentation, San Diego, 2010
Submitted: 2010-07-05
We report on the development of ARCONS, the ARray Camera for Optical to Near-IR Spectrophotometry. This photon counting integral field unit (IFU), being built at UCSB and Caltech with detectors fabricated at JPL, will use a unique, highly multiplexed low temperature detector technology known as Microwave Kinetic Inductance Detectors (MKIDs). These detectors, which operate at 100 mK, should provide photon counting with energy resolution of R = E/{\delta}E > 20 and time resolution of a microsecond, with a quantum efficiency of around 50%. We expect to field the instrument at the Palomar 200" telescope in the first quarter of 2011 with an array containing 1024 pixels in a 32x32 pixel form factor to yield a field of view of approximately 10x10 arcseconds. The bandwidth of the camera is limited by the rising sky count rate at longer wavelengths, but we anticipate a bandwidth of 0.35 to 1.35 {\mu}m will be achievable. A simple optical path and compact dewar utilizing a cryogen-free adiabatic demagnetization refridgerator (ADR) allows the camera to be deployed quickly at Naysmith or Coude foci at a variety of telescopes. A highly expandable software defined radio (SDR) readout that can scale up to much larger arrays has been developed.
[20]  oai:arXiv.org:1005.2517  [pdf] - 1032472
HIFI observations of warm gas in DR21: Shock versus radiative heating
Comments: Accepted for publication by A&A
Submitted: 2010-05-14
The molecular gas in the DR21 massive star formation region is known to be affected by the strong UV field from the central star cluster and by a fast outflow creating a bright shock. The relative contribution of both heating mechanisms is the matter of a long debate. By better sampling the excitation ladder of various tracers we provide a quantitative distinction between the different heating mechanisms. HIFI observations of mid-J transitions of CO and HCO+ isotopes allow us to bridge the gap in excitation energies between observations from the ground, characterizing the cooler gas, and existing ISO LWS spectra, constraining the properties of the hot gas. Comparing the detailed line profiles allows to identify the physical structure of the different components. In spite of the known shock-excitation of H2 and the clearly visible strong outflow, we find that the emission of all lines up to > 2 THz can be explained by purely radiative heating of the material. However, the new Herschel/HIFI observations reveal two types of excitation conditions. We find hot and dense clumps close to the central cluster, probably dynamically affected by the outflow, and a more widespread distribution of cooler, but nevertheless dense, molecular clumps.
[21]  oai:arXiv.org:cond-mat/0610130  [pdf] - 110417
A Position Sensitive X-ray Spectrophotometer using Microwave Kinetic Inductance Detectors
Comments: 4 pages, 2 figures. Submitted to Applied Physics Letters, August 25, 2006
Submitted: 2006-10-04
The surface impedance of a superconductor changes when energy is absorbed and Cooper pairs are broken to produce single electron (quasiparticle) excitations. This change may be sensitively measured using a thin-film resonant circuit called a microwave kinetic inductance detector (MKID). The practical application of MKIDs for photon detection requires a method of efficiently coupling the photon energy to the MKID. We present results on position sensitive X-ray detectors made by using two aluminum MKIDs on either side of a tantalum photon absorber strip. Diffusion constants, recombination times, and energy resolution are reported. MKIDs can easily be scaled into large arrays.