Normalized to: Budden, B.
[1]
oai:arXiv.org:1101.3732 [pdf] - 344847
Characteristic Count Rate Profiles for a Rotating Modulator Gamma-Ray
Imager
Submitted: 2010-12-13
Rotating modulation is a technique for indirect imaging in the hard x-ray and
soft gamma-ray energy bands, which may offer an advantage over coded aperture
imaging at high energies. A rotating modulator (RM) consists of a single mask
of co-planar parallel slats typically spaced equidistance apart, suspended
above an array of circular non-imaging detectors. The mask rotates, temporally
modulating the transmitted image of the object scene. The measured count rate
profiles of each detector are folded modulo the mask rotational period, and the
object scene is reconstructed using pre-determined characteristic modulation
profiles. The use of Monte Carlo simulation to derive the characteristic count
rate profiles is accurate but computationally expensive; an analytic approach
is preferred for its speed of computation. We present both the standard and a
new advanced characteristic formula describing the modulation pattern of the
RM; the latter is a more robust description of the instrument response
developed as part of the design of a wide-field high-resolution telescope for
gamma-ray astronomy. We examine an approximation to the advanced formula to
simplify reconstruction software and increase computational speed, and comment
on both the inherent limitations and usefulness of the approach. Finally, we
show comparisons to the standard formula and demonstrate image reconstructions
from Monte Carlo simulations.
[2]
oai:arXiv.org:1006.4332 [pdf] - 242135
Image Reconstruction with a LaBr3-based Rotational Modulator
Submitted: 2010-06-22, last modified: 2010-10-13
A rotational modulator (RM) gamma-ray imager is capable of obtaining
significantly better angular resolution than the fundamental geometric
resolution defined by the ratio of detector diameter to mask-detector
separation. An RM imager consisting of a single grid of absorbing slats
rotating ahead of an array of a small number of position-insensitive detectors
has the advantage of fewer detector elements (i.e., detector plane pixels) than
required by a coded aperture imaging system with comparable angular resolution.
The RM therefore offers the possibility of a major reduction in instrument
complexity, cost, and power. A novel image reconstruction technique makes it
possible to deconvolve the raw images, remove sidelobes, reduce the effects of
noise, and provide resolving power a factor of 6 - 8 times better than the
geometric resolution. A 19-channel prototype RM developed in our laboratory at
Louisiana State University features 13.8 deg full-angle field of view, 1.9 deg
geometric angular resolution, and the capability of resolving sources to within
35' separation. We describe the technique, demonstrate the measured performance
of the prototype instrument, and describe the prospects for applying the
technique to either a high-sensitivity standoff gamma-ray imaging detector or a
satellite- or balloon-borne gamma-ray astronomy telescope.
[3]
oai:arXiv.org:1003.5223 [pdf] - 241424
Noise-Compensating Algebraic Reconstruction for a Rotating Modulation
Gamma-Ray Imager
Submitted: 2010-03-26, last modified: 2010-10-12
A Rotating Modulator (RM) is one of a class of techniques for indirect
imaging of an object scene by modulation and detection of incident photons.
Comparison of the RM to more common imaging techniques, the Rotating Modulation
Collimator and the coded aperture, reveals trade-offs in instrument weight and
complexity, sensitivity, angular resolution, and image fidelity. In the case of
a high-energy (hundreds of keV to MeV), wide field-of-view, satellite or
balloon-borne astrophysical survey mission, the RM is shown to be an attractive
option when coupled with a reconstruction algorithm that can simultaneously
achieve super-resolution and suppress fluctuations arising from statistical
noise. We describe the Noise-Compensating Algebraic Reconstruction (NCAR)
algorithm, which is shown to perform better than traditional deconvolution
techniques for most object scene distributions. Results from Monte Carlo
simulations demonstrate that NCAR achieves super-resolution, can resolve
multiple point sources and complex distributions, and manifests noise as fuzzy
sidelobes about the true source location, rather than spurious peaks elsewhere
in the image as seen with other techniques.