Normalized to: Bruijn, M.
[1]
oai:arXiv.org:2003.11899 [pdf] - 2070581
Progress in the development of frequency domain multiplexing for the
X-ray Integral Field Unit on board the Athena mission
Akamatsu, H.;
Gottardi, L.;
van der Kuur, J.;
de Vries, C. P.;
Bruijn, M. P.;
Chervenak, J. A.;
Kiviranta, M.;
Linden, A. J. van den;
Jackson, B. D.;
Miniussi, A.;
Ravensberg, K.;
Sakai, K.;
Smith, S. J.;
Wakeham, N.
Submitted: 2020-03-26
Frequency domain multiplexing (FDM) is the baseline readout system for the
X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM
scheme, TESs are coupled to a passive LC filter and biased with alternating
current (AC bias) at MHz frequencies. Using high-quality factor LC filters and
room temperature electronics developed at SRON and low-noise two-stage SQUID
amplifiers provided by VTT, we have recently demonstrated good performance with
the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have
achieved a performance requested for the demonstration model (DM) with the
single pixel AC bias ($\Delta E=$1.8 eV) and 9 pixel multiplexing ($\Delta
E=$2.6 eV) modes. We have also demonstrated 14-pixel multiplexing with an
average energy resolution of 3.3 eV, which is limited by non-fundamental issues
related to FDM readout in our lab setup.
[2]
oai:arXiv.org:2001.11646 [pdf] - 2065397
Thermal simulations of temperature excursions on the Athena X-IFU
detector wafer from impacts by cosmic rays
Submitted: 2020-01-30
We present the design and implementation of a thermal model, developed in
COMSOL, aiming to probe the wafer-scale thermal response arising from realistic
rates and energies of cosmic rays at L2 impacting the detector wafer of Athena
X-IFU. The wafer thermal model is a four-layer 2D model, where 2 layers
represent the constituent materials (Si bulk and Si$_{3}$N$_{4}$ membrane), and
2 layers represent the Au metallization layer's phonon and electron
temperatures. We base the simulation geometry on the current specifications for
the X-IFU detector wafer, and simulate cosmic ray impacts using a simple power
injection into the Si bulk. We measure the temperature at the point of the
instrument's most central TES detector. By probing the response of the system
and pulse characteristics as a function of the thermal input energy and
location, we reconstruct cosmic ray pulses in Python. By utilizing this code,
along with the results of the GEANT4 simulations produced for X-IFU, we produce
realistic time-ordered data (TOD) of the temperature seen by the central TES,
which we use to simulate the degradation of the energy resolution of the
instrument in space-like conditions on this wafer. We find a degradation to the
energy resolution of 7 keV X-rays of $\approx$0.04 eV. By modifying wafer
parameters and comparing the simulated TOD, this study is a valuable tool for
probing design changes on the thermal background seen by the detectors.
[3]
oai:arXiv.org:1807.06423 [pdf] - 1718603
The SAFARI Detector System
Audley, Michael D.;
de Lange, Gert;
Gao, Jian-Rong;
Jackson, Brian D.;
Hijmering, Richard A.;
Ridder, Marcel L.;
Bruijn, Marcel P.;
Roelfsema, Peter R.;
Ade, Peter A. R.;
Withington, Stafford;
Bradford, Charles M.;
Trappe, Neal A.
Submitted: 2018-07-17, last modified: 2018-07-18
We give an overview of the baseline detector system for SAFARI, the prime
focal-plane instrument on board the proposed space infrared observatory, SPICA.
SAFARI's detectors are based on superconducting Transition Edge Sensors (TES)
to provide the extreme sensitivity (dark NEP$\le2\times10^{-19}\rm\ W/\sqrt
Hz$) needed to take advantage of SPICA's cold (<8 K) telescope. In order to
read out the total of ~3500 detectors we use frequency domain multiplexing
(FDM) with baseband feedback. In each multiplexing channel, a two-stage SQUID
preamplifier reads out 160 detectors. We describe the detector system and
discuss some of the considerations that informed its design.
[4]
oai:arXiv.org:1611.00956 [pdf] - 1521434
Development of frequency domain multiplexing for the X-ray Integral
Field Unit (X-IFU) on the Athena
Akamatsu, Hiroki;
Gottardi, Luciano;
van der Kuur, Jan;
de Vries, Cor P.;
Ravensberg, Kevin;
Adams, Joseph S.;
Bandler, Simon R.;
Bruijn, Marcel P.;
Chervenak, James A.;
Kilbourne, Caroline A;
Kiviranta, Mikko;
Linden, A. J. van den;
Jackson, Brian D.;
Smith, Stephen J.
Submitted: 2016-11-03
We are developing the frequency domain multiplexing (FDM) read-out of
transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field
Unit (X-IFU) instrument on board of the future European X-Ray observatory
Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a
high quantum efficiency ($>$90 \%) and spectral resolution $\Delta E$=2.5 eV
$@$ 7 keV ($E/\Delta E\sim$2800). FDM is currently the baseline readout system
for the X-IFU instrument. Using high quality factor LC filters and room
temperature electronics developed at SRON and low-noise two stage SQUID
amplifiers provided by VTT, we have recently demonstrated good performance with
the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated
noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been
demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We
have achieved X-ray energy resolutions $\sim$2.5 eV at AC bias frequency at 1.7
MHz in the single pixel read-out. We have also demonstrated for the first time
an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES
array (GSFC-A1). In this paper we report on the single pixel performance of
these microcalorimeters under MHz AC bias, and further results of the
performance of these pixels under FDM.
[5]
oai:arXiv.org:1604.02600 [pdf] - 1388309
A multiplexer for the ac/dc characterization of TES based bolometers and
microcalorimeters
Gottardi, Luciano;
Akamatsu, Hiroki;
Bruijn, Marcel;
Gao, Jan R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
van der Kuur, Jan;
van der Linden, Anoton;
Lindeman, Marcel;
Ridder, Marcel
Submitted: 2016-04-09
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the
read-out of the TES-based detector array for the future infrared and X-ray
space mission. We describe the performances of a multiplexer designed to
increase the experimental throughput in the characterisation of ultra-low noise
equivalent power (NEP) TES bolometers and high energy resolving power X-ray
microcalorimeters arrays under ac and dc bias. We discuss the results obtained
using the TiAu TES bolometers array fabricated at SRON with measured dark NEP
below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
[6]
oai:arXiv.org:1604.02593 [pdf] - 1388308
AC bias characterization of low noise bolometers for SAFARI using an
Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5
MHz
Gottardi, Luciano;
Bruijn, Marcel;
Gao, Jan-R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
de Korte, Piet;
van der Kuur, Jan;
Lindeman, Mark;
Ridder, Marcel
Submitted: 2016-04-09
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the
ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on
board of the Japanese space mission SPICA. The FDM prototype of the instrument
requires critical and complex optimizations. For single pixel characterization
under AC bias we are developing a simple FDM system working in the frequency
range from 1 to 5 MHz, based on the open loop read-out of a linearized
two-stage SQUID amplifier and high Q lithographic LC resonators. We describe
the details of the experimental set-up required to achieve low power loading (<
1 fW) and low noise (NEP $\sim 10^{-19} W/Hz^{1/2}$) in the TES bolometers. We
conclude the paper by comparing the performance of a $4 \cdot 10^{-19}
W/Hz^{1/2}$ TES bolometer measured under DC and AC bias.
[7]
oai:arXiv.org:1604.00670 [pdf] - 1489757
Development of the superconducting detectors and read-out for the X-IFU
instrument on board of the X-ray observatory Athena
Submitted: 2016-04-03
The Advanced Telescope for High-Energy Astrophysics (Athena) has been
selected by ESA as its second large-class mission. The future European X-ray
observatory will study the hot and energetic Universe with its launch foreseen
in 2028. Microcalorimeters based on superconducting Transition-edge sensor
(TES) are the chosen technology for the detectors array of the X-ray Integral
Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging
integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The
detector consists of an array of 3840 TESs coupled to X-ray absorbers and read
out in the MHz bandwidth using Frequency Domain Multiplexing (FDM) based on
Superconducting QUantum Interference Devices (SQUIDs). The proposed design
calls for devices with a high filling-factor, high quantum efficiency,
relatively high count-rate capability and an energy resolution of 2.5 eV at 5.9
keV. The paper will review the basic principle and the physics of the TES-based
microcalorimeters and present the state-of-the art of the FDM read-out.
[8]
oai:arXiv.org:1604.00680 [pdf] - 1384872
Weak-Link Phenomena in AC-Biased Transition Edge Sensors
Gottardi, Luciano;
Akamatsu, Hiroki;
Bruijn, Marcel;
Gao, Jan-R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
Kozorezov, Alex;
van der Kuur, Jan;
van der Linden, Anton;
Ridder, Marcel
Submitted: 2016-04-03
It has been recently demonstrated that superconducting transition edge
sensors (TESs) behave as weak-links due to longitudinally induced
superconductivity from the leads with higher Tc. In this work we study the
implication of this behaviour for TES-based bolometers and microcalorimeter
under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a
Frequency Domain Multiplexer based on a linearised two-stage SQUID amplifier
and high- Q lithographically made superconducting LC resonators. In particular,
we focus on SRON TiAu TES bolometers with a measured dark Noise Equivalent
Power (NEP) of $3.2 \cdot 10^{-19} W/Hz^{1/2}$ developed for the short
wavelength band for the instrument SAFARI on the SPICA telescope.
[9]
oai:arXiv.org:1604.00553 [pdf] - 1384861
Development of TES-based detectors array for the X-ray Integral Field
Unit (X-IFU) on the future x-ray observatory ATHENA
Gottardi, Luciano;
Akamatsu, Hiroki;
Barret, Didier;
Bruijn, Marcel P.;
Hartog, Roland H. den;
Herder, Jan-Willem den;
Hoevers, Henk F. C.;
Kiviranta, Mikko;
van der Kuur, Jan;
van der Linden, Anton J.;
Jackson, Brian D.;
Jambunathan, Madu;
Ridder, Marcel L.
Submitted: 2016-04-02
We are developing transition-edge sensor (TES)-based microcalorimeters for
the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory
Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m
squared, AuBi absorbers. We designed and fabricated devices with different
contact geometries between the absorber and the TES to optimise the detector
performance and with different wiring topology to mitigate the self-magnetic
field. The design is tailored to optimise the performance under Frequency
Domain Multiplexing. In this paper we review the main design feature of the
pixels array and we report on the performance of the 18 channels, 2-5MHz
frequency domain multiplexer that will be used to characterised the detector
array.