Normalized to: Bruch, T.
[1]
oai:arXiv.org:1304.4279 [pdf] - 732067
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-04-15, last modified: 2013-10-11
We report results of a search for Weakly Interacting Massive Particles
(WIMPS) with the silicon detectors of the CDMS II experiment. This blind
analysis of 140.2 kg-days of data taken between July 2007 and September 2008
revealed three WIMP-candidate events with a surface-event background estimate
of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds
from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90%
confidence level, respectively. The exposure of this analysis is equivalent to
23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10
GeV/c2. The probability that the known backgrounds would produce three or more
events in the signal region is 5.4%. A profile likelihood ratio test of the
three events that includes the measured recoil energies gives a 0.19%
probability for the known-background-only hypothesis when tested against the
alternative WIMP+background hypothesis. The highest likelihood occurs for a
WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
[2]
oai:arXiv.org:1304.3706 [pdf] - 719385
Silicon detector results from the first five-tower run of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Di Stefano, P. C. F.;
Silva, E. do Couto e;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Lopez-Asamar, E.;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhan, J.
Submitted: 2013-04-12, last modified: 2013-09-14
We report results of a search for Weakly Interacting Massive Particles
(WIMPs) with the Si detectors of the CDMS II experiment. This report describes
a blind analysis of the first data taken with CDMS II's full complement of
detectors in 2006-2007; results from this exposure using the Ge detectors have
already been presented. We observed no candidate WIMP-scattering events in an
exposure of 55.9 kg-days before analysis cuts, with an expected background of
~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a
recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10
GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon
spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude
parameter space for spin-independent WIMP-nucleon elastic scattering that is
relevant to recent searches for low-mass WIMPs.
[3]
oai:arXiv.org:1203.1309 [pdf] - 564223
Search for annual modulation in low-energy CDMS-II data
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Anderson, A. J.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dragowsky, M. R.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D. C.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D.;
Serfass, B.;
Speller, D.;
Sundqvist, K. M.;
Tarka, M.;
Thakur, R. B.;
Villano, A. N.;
Welliver, B.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2012-03-06, last modified: 2012-09-18
We report limits on annual modulation of the low-energy event rate from the
Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground
Laboratory. Such a modulation could be produced by interactions from Weakly
Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no
evidence for annual modulation in the event rate of veto-anticoincident
single-detector interactions consistent with nuclear recoils, and constrain the
magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9
keVnr energy range at the 99% confidence level. These results disfavor an
explanation for the reported modulation in the 1.2-3.2 keVee energy range in
CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs
at >98% confidence. For events consistent with electron recoils, no significant
modulation is observed for either single- or multiple-detector interactions in
the 3.0-7.4 keVee range.
[4]
oai:arXiv.org:1103.2125 [pdf] - 1052646
Gator: a low-background counting facility at the Gran Sasso Underground
Laboratory
Baudis, L.;
Ferella, A. D.;
Askin, A.;
Angle, J.;
Aprile, E.;
Bruch, T.;
Kish, A.;
Laubenstein, M.;
Manalaysay, A.;
Undagoitia, T. Marrodan;
Schumann, M.
Submitted: 2011-03-10, last modified: 2012-01-10
A low-background germanium spectrometer has been installed and is being
operated in an ultra-low background shield (the Gator facility) at the Gran
Sasso underground laboratory in Italy (LNGS). With an integrated rate of ~0.16
events/min in the energy range between 100-2700 keV, the background is
comparable to those of the world's most sensitive germanium detectors. After a
detailed description of the facility, its background sources as well as the
calibration and efficiency measurements are introduced. Two independent
analysis methods are described and compared using examples from selected sample
measurements. The Gator facility is used to screen materials for XENON, GERDA,
and in the context of next-generation astroparticle physics facilities such as
DARWIN.
[5]
oai:arXiv.org:1104.3121 [pdf] - 418418
Implications on Inelastic Dark Matter from 100 Live Days of XENON100
Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-15, last modified: 2011-09-09
The XENON100 experiment has recently completed a dark matter run with 100.9
live-days of data, taken from January to June 2010. Events in a 48kg fiducial
volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A
total of three events have been found in the predefined signal region,
compatible with the background prediction of (1.8 \pm 0.6) events. Based on
this analysis we present limits on the WIMP-nucleon cross section for inelastic
dark matter. With the present data we are able to rule out the explanation for
the observed DAMA/LIBRA modulation as being due to inelastic dark matter
scattering off iodine at a 90% confidence level.
[6]
oai:arXiv.org:1104.2549 [pdf] - 966664
Dark Matter Results from 100 Live Days of XENON100 Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-13, last modified: 2011-09-07
We present results from the direct search for dark matter with the XENON100
detector, installed underground at the Laboratori Nazionali del Gran Sasso of
INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg
liquid xenon target. Interaction vertex reconstruction in three dimensions with
millimeter precision allows to select only the innermost 48 kg as ultra-low
background fiducial target. In 100.9 live days of data, acquired between
January and June 2010, no evidence for dark matter is found. Three candidate
events were observed in a pre-defined signal region with an expected background
of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter
interactions today, excluding spin-independent elastic WIMP-nucleon scattering
cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90%
confidence level.
[7]
oai:arXiv.org:1103.0303 [pdf] - 427646
Likelihood Approach to the First Dark Matter Results from XENON100
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-03-01, last modified: 2011-09-07
Many experiments that aim at the direct detection of Dark Matter are able to
distinguish a dominant background from the expected feeble signals, based on
some measured discrimination parameter. We develop a statistical model for such
experiments using the Profile Likelihood ratio as a test statistic in a
frequentist approach. We take data from calibrations as control measurements
for signal and background, and the method allows the inclusion of data from
Monte Carlo simulations. Systematic detector uncertainties, such as
uncertainties in the energy scale, as well as astrophysical uncertainties, are
included in the model. The statistical model can be used to either set an
exclusion limit or to make a discovery claim, and the results are derived with
a proper treatment of statistical and systematic uncertainties. We apply the
model to the first data release of the XENON100 experiment, which allows to
extract additional information from the data, and place stronger limits on the
spin-independent elastic WIMP-nucleon scattering cross-section. In particular,
we derive a single limit, including all relevant systematic uncertainties, with
a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
[8]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
[9]
oai:arXiv.org:1012.5078 [pdf] - 371990
Search for inelastic dark matter with the CDMS II experiment
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Silva, E. do Couto e;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P.;
Dragowsky, M. R.;
Duong, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S. A.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Razeti, M.;
Reisetter, A.;
Resch, R.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Wikus, P.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2010-12-22, last modified: 2011-06-12
Results are presented from a reanalysis of the entire five-tower data set
acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the
Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis
window was extended to a recoil energy of 150 keV, and an improved
surface-event background-rejection cut was defined to increase the sensitivity
of the experiment to the inelastic dark matter (iDM) model. Three dark matter
candidates were found between 25 keV and 150 keV. The probability to observe
three or more background events in this energy range is 11%. Because of the
occurrence of these events the constraints on the iDM parameter space are
slightly less stringent than those from our previous analysis, which used an
energy window of 10-100 keV.
[10]
oai:arXiv.org:1011.2482 [pdf] - 347805
Results from a Low-Energy Analysis of the CDMS II Germanium Data
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Silva, E. do Couto e;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P.;
Dragowsky, M. R.;
Duong, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S. A.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Reisetter, A.;
Resch, R.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Wikus, P.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2010-11-10, last modified: 2011-04-21
We report results from a reanalysis of data from the Cryogenic Dark Matter
Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken
between October 2006 and September 2008 using eight germanium detectors are
reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased
sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs)
with masses below ~10 GeV/c^2. This analysis provides stronger constraints than
previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter
space associated with possible low-mass WIMP signals from the DAMA/LIBRA and
CoGeNT experiments.
[11]
oai:arXiv.org:1101.5298 [pdf] - 368547
Background Measurements in the Gran Sasso Underground Laboratory
Submitted: 2011-01-27, last modified: 2011-04-16
The gamma background flux below 3000 keV in the Laboratori Nazionali del Gran
Sasso (LNGS), Italy, has been measured using a 3" diameter NaI(Tl) detector at
different underground positions: In hall A, hall B, the interferometer tunnel,
and inside the Large Volume Detector (LVD). The integrated flux is 0.3--0.4
s$^{-1}$cm$^{-2}$ at the first three locations, and is lower by two orders of
magnitude inside LVD. With the help of Monte Carlo simulations for every
location, the contribution of the individual primordial isotopes to the
background has been determined. Using an 11" diameter NaI(Tl) detector, the
background neutron flux in the LNGS interferometer tunnel has been estimated.
Within the uncertainties, the result agrees with those from other neutron
measurements in the main halls.
[12]
oai:arXiv.org:1001.3037 [pdf] - 1934513
CDMS-II to SuperCDMS: WIMP search at a zeptobarn
Submitted: 2010-01-18
The Cryogenic Dark Matter search experiment (CDMS) employs low-temperature Ge
and Si detectors to detect WIMPs via their elastic scattering of target nuclei.
The last analysis with an germanium exposure of 397.8 kg-days resulted in zero
observed candidate events, setting an upper limit on the spin-independent
WIMP-nucleon cross-section of 6.6 x 10^{-44} cm^2 (4.6 x 10^{-44} cm^2, when
previous CDMS Soudan data is included) for a WIMP mass of 60 GeV. The
improvements in the surface event rejection capability for the current analysis
with an germanium exposure about a factor of 2.5 greater than used in the last
analysis will be discussed. To increase the sensitivity beyond the 1 x 10^{-44}
cm^2 benchmark new 1 inch thick detectors have been developed. A first tower
consisting of six of these detectors has been successfully installed at the
Soudan site. These detectors will be used in a 15 kg SuperCDMS stage with an
expected sensitivity on the spin-independent WIMP-nucleon elastic scattering
cross-section of 5 x 10^{-45} cm^2. In addition, the CDMS Collaboration has
started to look for signatures of non WIMP dark matter particles, which may
explain the annual modulation signature observed by DAMA.
[13]
oai:arXiv.org:0907.1438 [pdf] - 142195
Analysis of the low-energy electron-recoil spectrum of the CDMS
experiment
Ahmed, Z.;
Akerib, D. S.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Beaty, J.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Cushman, P.;
DeJongh, F.;
Dragowsky, M. R.;
Duong, L.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fritts, M.;
Golwala, S. R.;
Grant, D. R.;
Hall, J.;
Hennings-Yeomans, R.;
Hertel, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Mahapatra, R.;
Mandic, V.;
Moore, D.;
McCarthy, K. A.;
Mirabolfathi, N.;
Nelson, H.;
Ogburn, R. W.;
Pyle, M.;
Qiu, X.;
Ramberg, E.;
Rau, W.;
Reisetter, A.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Wang, G.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Collaboration, the CDMS
Submitted: 2009-07-09
We report on the analysis of the low-energy electron-recoil spectrum from the
CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis
provides details on the observed counting rate and possible background sources
in the energy range of 2 - 8.5 keV. We find no significant excess in the
counting rate above background, and compare this observation to the recent DAMA
results. In the framework of a conversion of a dark matter particle into
electromagnetic energy, our 90% confidence level upper limit of 0.246
events/kg/day at 3.15 keV is lower than the total rate above background
observed by DAMA by 8.9$\sigma$. In absence of any specific particle physics
model to provide the scaling in cross section between NaI and Ge, we assume a
Z^2 scaling. With this assumption the observed rate in DAMA differs from the
upper limit in CDMS by 6.8$\sigma$. Under the conservative assumption that the
modulation amplitude is 6% of the total rate we obtain upper limits on the
modulation amplitude a factor of ~2 less than observed by DAMA, constraining
some possible interpretations of this modulation.
[14]
oai:arXiv.org:0804.2896 [pdf] - 11877
Detecting the Milky Way's Dark Disk
Submitted: 2008-04-17, last modified: 2009-06-18
In LambdaCDM, massive satellites are dragged into the disk-plane by dynamical
friction where they dissolve into a stellar thick disk and a more massive dark
matter disk. The distinctive kinematics of the dark disk matches the stars that
also entered in the satellites. The lower velocities of the dark disk with
respect to the Earth enhances detection rates at low recoil energy. For WIMP
masses > 50 GeV/c^2, the detection rate increases by up to a factor of 3 in the
5 - 20 keV recoil energy range. Comparing this with rates at higher energy will
improve constraints on the WIMP mass, particularly for masses > 100 GeV/c^2.
The annual modulation signal of the dark disk is significantly boosted and its
modulation phase is shifted by ~3 weeks relative to the dark halo. The
variation of the observed phase with recoil energy can also be used to
determine the WIMP mass once the dark disk properties are fixed by future
astronomical surveys. The constraints on the WIMP interaction cross section
from current experiments improve by factors of 1.4 to 3.5 when a typical
contribution from the dark disk is included.
[15]
oai:arXiv.org:0902.4001 [pdf] - 148486
Dark Matter Disc Enhanced Neutrino Fluxes from the Sun and Earth
Submitted: 2009-02-23, last modified: 2009-04-21
As disc galaxies form in a hierarchical cosmology, massive merging satellites
are preferentially dragged towards the disc plane. The material accreted from
these satellites forms a dark matter disc that contributes 0.25 - 1.5 times the
non-rotating halo density at the solar position. Here, we show the importance
of the dark disc for indirect dark matter detection in neutrino telescopes.
Previous predictions of the neutrino flux from WIMP annihilation in the Earth
and the Sun have assumed that Galactic dark matter is spherically distributed
with a Gaussian velocity distribution, the standard halo model. Although the
dark disc has a local density comparable to the dark halo, its higher phase
space density at low velocities greatly enhances capture rates in the Sun and
Earth. For typical dark disc properties, the resulting muon flux from the Earth
is increased by three orders of magnitude over the SHM, while for the Sun the
increase is an order of magnitude. This significantly increases the sensitivity
of neutrino telescopes to fix or constrain parameters in WIMP models. The flux
from the Earth is extremely sensitive to the detailed properties of the dark
disc, while the flux from the Sun is more robust. The enhancement of the muon
flux from the dark disc puts the search for WIMP annihilation in the Earth on
the same level as the Sun for WIMP masses < 100 GeV.
[16]
oai:arXiv.org:0811.4171 [pdf] - 1934294
Search for Solar Axions with the CDMS-II Experiment
Submitted: 2008-11-25, last modified: 2008-12-12
The CDMS-II experiment operates 19 germanium detectors with a mass of 250g
each in a very low background environment. Originally designed for the search
for Dark Matter the experiment can also detect solar axions by Primakoff
conversion to photons. The Bragg condition for X-ray momentum transfer in a
crystal allows for coherent amplification of the Primakoff process. Since the
orientation of the crystal lattice with respect to the Sun changes with daytime
an unique pattern in time and energy of solar axion conversions is expected.
The low background ~1.5 counts/kg/day/keV and knowledge of the exact
orientation of all three crystal axes with respect to the Sun make the CDMS-II
experiment very sensitive to solar axions. In contrast to helioscopes, the high
mass region < 1 keV can also be probed effectively. The alternating
orientations of the individual crystals in the experimental setup provide
different patterns of solar axion conversion, making a false positive result
extremely unlikely. The result of an analysis of 289 kg-days of exposure
resulted in a null observation of solar axion conversion. This analysis sets an
upper limit on the axion photon coupling constant of g_{a\gamma\gamma} < 2.6 x
10^{-9} GeV{-1} at a 95% confidence level.
[17]
oai:arXiv.org:0811.4172 [pdf] - 121225
Signatures of the Milky Way's Dark Disk in Current and Future
Experiments
Submitted: 2008-11-25, last modified: 2008-11-26
In hierarchical structure formation models of disk galaxies, a dark matter
disk forms as massive satellites are preferentially dragged into the disk-plane
where they dissolve. Here, we quantify the importance of this dark disk for
direct and indirect dark matter detection. The low velocity of the dark disk
with respect to the Earth enhances detection rates in direct detection
experiments at low recoil energy. For WIMP masses M_{WIMP} >~ 50 GeV, the
detection rate increases by up to a factor of 3 in the 5 - 20 keV recoil energy
range. Comparing this with rates at higher energy is sensitive to M_{WIMP},
providing stronger mass constraints particularly for M_{WIMP}>~100 GeV. The
annual modulation signal is significantly boosted by the dark disk and the
modulation phase is shifted by ~3 weeks relative to the dark halo. The
variation of the observed phase with recoil energy determines M_{WIMP}, once
the dark disk properties are fixed by future astronomical surveys. The low
velocity of the particles in the dark disk with respect to the solar system
significantly enhances the capture rate of WIMPs in the Sun, leading to an
increased flux of neutrinos from the Sun which could be detected in current and
future neutrino telescopes. The dark disk contribution to the muon flux from
neutrino back conversion at the Earth is increased by a factor of ~5 compared
to the SHM, for rho_d/rho_h=0.5.
[18]
oai:arXiv.org:0809.4186 [pdf] - 1934250
Recent results from the CDMS-II experiment
Submitted: 2008-09-24
The Cryogenic Dark Matter Search experiment (CDMS) employs low-temperature Ge
and Si detectors to detect WIMPs via their elastic scattering interaction with
the target nuclei. The current analysis of 397.8 kg-days Ge exposure resulted
in zero observed candidate events, setting an upper limit on the
spin-independent WIMP-nucleon cross-section of 6.6 x 10^{-44} cm^2 (4.6 x
10^{-44} cm^2, when previous CDMS Soudan data is included) at the 90 %
confidence level for a WIMP mass of 60 GeV. To increase the sensitivity, new
one inch thick detectors have been developed which will be used in the
SuperCDMS phase. SuperCDMS 25kg will be operated at SNOLAB with an expected
sensitivity on the spin-independent WIMP-nucleon elastic scattering
cross-section of 1 x 10^{-45} cm^2.