Normalized to: Bruccoleri, A.
[1]
oai:arXiv.org:1812.08229 [pdf] - 1834189
Demonstration of resolving power $\lambda/\Delta\lambda > 10,000$ for a
space-based x-ray transmission grating spectrometer
Submitted: 2018-12-19
We present measurements of the resolving power of a soft x-ray spectrometer
consisting of 200 nm-period lightweight, alignment-insensitive critical-angle
transmission (CAT) gratings and a lightweight slumped-glass Wolter-I focusing
mirror pair. We measure and model contributions from source, mirrors, detector
pixel size, and grating period variation to the natural line width spectrum of
the Al and Mg K$_{\alpha_1 \alpha_2}$ doublets. Measuring up to 18$^{\rm th}$
diffraction order at characteristic Al-K wavelengths we consistently obtain
small broadening due to gratings corresponding to a minimum effective grating
resolving power $R_g > 10,000$ with 90\% confidence. Upper limits are often
compatible with $R_g = \infty$. Independent fitting of different diffraction
orders, as well as ensemble fitting of multiple orders at multiple wavelengths,
gives compatible results. Our data leads to uncertainties for the
Al-K$_{\alpha}$ doublet line width and line separation parameters 2-3 times
smaller than values found in the literature. Data from three different gratings
are mutually compatible. This demonstrates that CAT gratings perform in excess
of the requirements for the Arcus Explorer mission and are suitable for
next-generation space-based x-ray spectrometer designs with resolving power
5-10 times higher than the transmission grating spectrometer on the Chandra
X-ray Observatory.
[2]
oai:arXiv.org:1607.04517 [pdf] - 1521256
Critical-angle x-ray transmission grating spectrometer with extended
bandpass and resolving power > 10,000
Submitted: 2016-07-15
Several high priority subjects in astrophysics can be addressed by a
state-of-the-art soft x-ray grating spectrometer (XGS). An Explorer-scale,
large-area (> 1,000 cm2), high resolving power (R > 3,000) XGS is highly
feasible based on Critical-Angle Transmission (CAT) gratings, even for
telescopes with angular resolution of 5-10 arcsec. Significantly higher
performance can be provided by a CAT XGS on an X-ray-Surveyor-type mission. CAT
gratings combine the advantages of blazed reflection gratings (high efficiency,
use of higher diffraction orders) with those of transmission gratings (low
mass, relaxed alignment and temperature requirements, transparent at high
energies) with minimal mission resource demands. They are high-efficiency
blazed transmission gratings that consist of freestanding, ultra-high
aspect-ratio grating bars made from SOI wafers using anisotropic dry and wet
etch techniques. Blazing is achieved through reflection off grating bar
sidewalls. Silicon is well matched to the soft x-ray band, and existing silicon
CAT gratings exceed 30% absolute diffraction efficiency, with clear paths for
improvement. CAT gratings coated with heavier elements allow extension of the
CAT grating principle to higher energies and larger angles, enabling higher
resolving power at shorter wavelengths. We show x-ray data from CAT gratings
coated with platinum using atomic layer deposition, and demonstrate blazing to
higher energies and much larger blaze angles than possible with silicon. We
measure resolving power of a CAT XGS consisting of a Wolter-I focusing mirror
pair from GSFC and CAT gratings, performed at the MSFC SLF. Measurement of the
Al Ka doublet in 18th order shows resolving power > 10,000, based on
preliminary analysis. This demonstrates that currently fabricated CAT gratings
are compatible with the most advanced XGS designs for future soft x-ray
spectroscopy missions.