Normalized to: Brubaker, B.
[1]
oai:arXiv.org:2006.15787 [pdf] - 2126309
Experimental constraint on axion-like particle coupling over seven
orders of magnitude in mass
Roussy, Tanya S.;
Palken, Daniel A.;
Cairncross, William B.;
Brubaker, Benjamin M.;
Gresh, Daniel N.;
Grau, Matt;
Cossel, Kevin C.;
Ng, Kia Boon;
Shagam, Yuval;
Zhou, Yan;
Flambaum, Victor V.;
Lehnert, Konrad W.;
Ye, Jun;
Cornell, Eric A.
Submitted: 2020-06-28, last modified: 2020-06-30
We use our recent electric dipole moment (EDM) measurement data to constrain
the possibility that the HfF$^+$ EDM oscillates in time due to interactions
with candidate dark matter axion-like particles (ALPs). We employ a Bayesian
analysis method which accounts for both the look-elsewhere effect and the
uncertainties associated with stochastic density fluctuations in the ALP field.
We find no evidence of an oscillating EDM over a range spanning from 27 nHz to
400 mHz, and we use this result to constrain the ALP-gluon coupling over the
mass range $10^{-22}-10^{-15}$ eV. This is the first laboratory constraint on
the ALP-gluon coupling in the $10^{-17}-10^{-15}$ eV range, and the first
laboratory constraint to properly account for the stochastic nature of the ALP
field.
[2]
oai:arXiv.org:2003.08510 [pdf] - 2124673
An improved analysis framework for axion dark matter searches
Palken, D. A.;
Brubaker, B. M.;
Malnou, M.;
Kenany, S. Al;
Backes, K. M.;
Cahn, S. B.;
Gurevich, Y. V.;
Lamoreaux, S. K.;
Lewis, S. M.;
Maruyama, R. H.;
Rapidis, N. M.;
Root, J. R.;
Simanovskaia, M.;
Shokair, T. M.;
Singh, Sukhman;
Speller, D. H.;
Urdinaran, I.;
van Bibber, K.;
Zhong, L.;
Lehnert, K. W.
Submitted: 2020-03-18, last modified: 2020-06-13
In experiments searching for axionic dark matter, the use of the standard
threshold-based data analysis discards valuable information. We present a
Bayesian analysis framework that builds on an existing processing protocol to
extract more information from the data of coherent axion detectors such as
operating haloscopes. The analysis avoids logical subtleties that accompany the
standard analysis framework and enables greater experimental flexibility on
future data runs. Performing this analysis on the existing data from the
HAYSTAC experiment, we find improved constraints on the axion-photon coupling
$g_\gamma$ while also identifying the most promising regions of parameter space
within the $23.15$--$24.0$ $\mu$eV mass range. A comparison with the standard
threshold analysis suggests a $36\%$ improvement in scan rate from our
analysis, demonstrating the utility of this framework for future axion
haloscope analyses.
[3]
oai:arXiv.org:1801.00835 [pdf] - 1612057
First results from the HAYSTAC axion search
Submitted: 2018-01-02
The axion is a well-motivated cold dark matter (CDM) candidate first
postulated to explain the absence of $CP$ violation in the strong interactions.
CDM axions may be detected via their resonant conversion into photons in a
"haloscope" detector: a tunable high-$Q$ microwave cavity maintained at
cryogenic temperature, immersed a strong magnetic field, and coupled to a
low-noise receiver.
This dissertation reports on the design, commissioning, and first operation
of the Haloscope at Yale Sensitive to Axion CDM (HAYSTAC), a new detector
designed to search for CDM axions with masses above $20$ $\mu\mathrm{eV}$. I
also describe the analysis procedure developed to derive limits on axion CDM
from the first HAYSTAC data run, which excluded axion models with two-photon
coupling $g_{a\gamma\gamma} \gtrsim 2\times10^{-14}$ $\mathrm{GeV}^{-1}$, a
factor of 2.3 above the benchmark KSVZ model, over the mass range $23.55 < m_a
< 24.0$ $\mu\mathrm{eV}$.
This result represents two important achievements. First, it demonstrates
cosmologically relevant sensitivity an order of magnitude higher in mass than
any existing direct limits. Second, by incorporating a dilution refrigerator
and Josephson parametric amplifier, HAYSTAC has demonstrated total noise
approaching the standard quantum limit for the first time in a haloscope axion
search.
[4]
oai:arXiv.org:1706.08388 [pdf] - 1606998
The HAYSTAC Axion Search Analysis Procedure
Submitted: 2017-06-26, last modified: 2017-12-22
We describe in detail the analysis procedure used to derive the first limits
from the Haloscope at Yale Sensitive to Axion CDM (HAYSTAC), a microwave cavity
search for cold dark matter (CDM) axions with masses above $20\ \mu\text{eV}$.
We have introduced several significant innovations to the axion search analysis
pioneered by the Axion Dark Matter eXperiment (ADMX), including optimal
filtering of the individual power spectra that constitute the axion search
dataset and a consistent maximum likelihood procedure for combining and
rebinning these spectra. These innovations enable us to obtain the axion-photon
coupling $|g_\gamma|$ excluded at any desired confidence level directly from
the statistics of the combined data.
[5]
oai:arXiv.org:1706.03676 [pdf] - 1584550
Recent Technical Improvements to the HAYSTAC Experiment
Submitted: 2017-06-12, last modified: 2017-08-07
We report here several technical improvements to the HAYSTAC (Haloscope at
Yale Sensitive To Axion Cold dark matter) that have improved operational
efficiency, sensitivity, and stability.
[6]
oai:arXiv.org:1611.07123 [pdf] - 1537416
Design and Operational Experience of a Microwave Cavity Axion Detector
for the 20-100 micro-eV Range
Kenany, S. Al;
Anil, M. A.;
Backes, K. M.;
Brubaker, B. M.;
Cahn, S. B.;
Carosi, G.;
Gurevich, Y. V.;
Kindel, W. F.;
Lamoreaux, S. K.;
Lehnert, K. W.;
Lewis, S. M.;
Malnou, M.;
Palken, D. A.;
Rapidis, N. M.;
Root, J. R.;
Simanovskaia, M.;
Shokair, T. M.;
Urdinaran, I.;
van Bibber, K. A.;
Zhong, L.
Submitted: 2016-11-21, last modified: 2017-02-22
We describe a dark matter axion detector designed, constructed, and operated
both as an innovation platform for new cavity and amplifier technologies and as
a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: \mu$eV). The
platform is small but flexible to facilitate the development of new microwave
cavity and amplifier concepts in an operational environment. The experiment has
recently completed its first data production; it is the first microwave cavity
axion search to deploy a Josephson parametric amplifier and a dilution
refrigerator to achieve near-quantum limited performance.
[7]
oai:arXiv.org:1610.02580 [pdf] - 1531959
First results from a microwave cavity axion search at 24 micro-eV
Brubaker, B. M.;
Zhong, L.;
Gurevich, Y. V.;
Cahn, S. B.;
Lamoreaux, S. K.;
Simanovskaia, M.;
Root, J. R.;
Lewis, S. M.;
Kenany, S. Al;
Backes, K. M.;
Urdinaran, I.;
Rapidis, N. M.;
Shokair, T. M.;
van Bibber, K. A.;
Palken, D. A.;
Malnou, M.;
Kindel, W. F.;
Anil, M. A.;
Lehnert, K. W.;
Carosi, G.
Submitted: 2016-10-08, last modified: 2017-02-09
We report on the first results from a new microwave cavity search for dark
matter axions with masses above $20~\mu\text{eV}$. We exclude axion models with
two-photon coupling $g_{a\gamma\gamma} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$
over the range $23.55~\mu\text{eV} < m_a < 24.0~\mu\text{eV}$. These results
represent two important achievements. First, we have reached cosmologically
relevant sensitivity an order of magnitude higher in mass than any existing
limits. Second, by incorporating a dilution refrigerator and Josephson
parametric amplifier, we have demonstrated total noise approaching the standard
quantum limit for the first time in an axion search.