oai:arXiv.org:1909.12785 [pdf] - 2045242
Imaging Polarimetry of the 2017 Solar Eclipse with the RIT Polarization
Imaging Camera
Submitted: 2019-09-27
In the last decade, imaging polarimeters based on micropolarizer arrays have
been developed for use in terrestrial remote sensing and metrology
applications. Micropolarizer-based sensors are dramatically smaller and more
mechanically robust than other polarimeters with similar spectral response and
snapshot capability. To determine the suitability of these new polarimeters for
astronomical applications, we developed the RIT Polarization Imaging Camera to
investigate the performance of these devices, with a special attention to the
low signal-to-noise regime. We characterized the device performance in the lab,
by determining the relative throughput, efficiency, and orientation of every
pixel, as a function of wavelength. Using the resulting pixel response model,
we developed demodulation procedures for aperture photometry and imaging
polarimetry observing modes. We found that, using the current calibration,
RITPIC is capable of detecting polarization signals as small as <0.3%. To
demonstrate the stability of RITPIC's calibration and its extreme portability,
we performed imaging polarimetry of the Solar corona in Madras, Oregon during
the total Solar eclipse of 2017. The maximum polarization we measured was ~46%,
which agrees well with the maximum value predicted for a Thomson scattering
corona. Similarly, we found no strong deviations in the angle of linear
polarization from the tangential direction. The relative ease of data
collection, calibration, and analysis provided by these sensors suggest than
they may become an important tool for a number of astronomical targets.
[2]
oai:arXiv.org:1710.04255 [pdf] - 1671979
Astronomical Polarimetry with the RIT Polarization Imaging Camera
Submitted: 2017-10-11, last modified: 2018-04-24
In the last decade, imaging polarimeters based on micropolarizer arrays have
been developed for use in terrestrial remote sensing and metrology
applications. Micropolarizer-based sensors are dramatically smaller and more
mechanically robust than other polarimeters with similar spectral response and
snapshot capability. To determine the suitability of these new polarimeters for
astronomical applications, we developed the RIT Polarization Imaging Camera to
investigate the performance of these devices, with a special attention to the
low signal-to-noise regime. We characterized the device performance in the lab,
by determining the relative throughput, efficiency, and orientation of every
pixel, as a function of wavelength. Using the resulting pixel response model,
we developed demodulation procedures for aperture photometry and imaging
polarimetry observing modes. We found that, using the current calibration,
RITPIC is capable of detecting polarization signals as small as $\sim0.3\%$.
The relative ease of data collection, calibration, and analysis provided by
these sensors suggest than they may become an important tool for a number of
astronomical targets.