sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Brice, S. J.

Normalized to: Brice, S.

7 article(s) in total. 269 co-authors, from 1 to 6 common article(s). Median position in authors list is 9,0.

[1]  oai:arXiv.org:1601.03729  [pdf] - 1382109
Improved dark matter search results from PICO-2L Run 2
Comments:
Submitted: 2016-01-14, last modified: 2016-03-25
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nuclear-recoil event was observed in the data, consistent both with the predicted background rate from neutrons and with the observed rate of unambiguous multiple-bubble neutron scattering events. The chamber exhibits the same excellent electron-recoil and alpha decay rejection as was previously reported. These data provide the most stringent direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
[2]  oai:arXiv.org:1510.07754  [pdf] - 1382070
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Comments: v3 to reflect published version
Submitted: 2015-10-26, last modified: 2016-03-03
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining $48.2\%$ of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.
[3]  oai:arXiv.org:1503.00008  [pdf] - 1238863
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Comments: 6 pages, 6 figures, v2 to match published version
Submitted: 2015-02-27, last modified: 2015-06-29
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. These data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.
[4]  oai:arXiv.org:1304.6001  [pdf] - 778562
Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber
Comments: 5 pages, 3 figures
Submitted: 2013-04-22, last modified: 2014-01-31
We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel telescope and the reconstructed scattering angle provides a measure of the nuclear recoil kinetic energy. The bubble chamber was operated with a nominal threshold of (13.6+-0.6) keV. Interpretation of the results depends on the response to fluorine and carbon recoils, but in general we find agreement with the predictions of the classical bubble nucleation theory. This measurement confirms the applicability of CF3I as a target for spin-independent dark matter interactions and represents a novel technique for calibration of superheated fluid detectors.
[5]  oai:arXiv.org:1204.3094  [pdf] - 565655
First dark matter search results from a 4-kg CF$_3$I bubble chamber operated in a deep underground site
Comments: 9 pages, 7 figures, 2 tables
Submitted: 2012-04-13, last modified: 2012-09-19
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha-decay background events from single nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of alpha-decay events. Twenty single nuclear recoil event candidates and three multiple bubble events were observed during a total exposure of 553 kg-days distributed over three different bubble nucleation thresholds. The effective exposure for single bubble recoil-like events was 437.4 kg-days. A neutron background internal to the apparatus, of known origin, is estimated to account for five single nuclear recoil events and is consistent with the observed rate of multiple bubble events. This observation provides world best direct detection constraints on WIMP-proton spin-dependent scattering for WIMP masses $>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent interactions.
[6]  oai:arXiv.org:1204.5379  [pdf] - 503740
Light Sterile Neutrinos: A White Paper
Abazajian, K. N.; Acero, M. A.; Agarwalla, S. K.; Aguilar-Arevalo, A. A.; Albright, C. H.; Antusch, S.; Arguelles, C. A.; Balantekin, A. B.; Barenboim, G.; Barger, V.; Bernardini, P.; Bezrukov, F.; Bjaelde, O. E.; Bogacz, S. A.; Bowden, N. S.; Boyarsky, A.; Bravar, A.; Berguno, D. Bravo; Brice, S. J.; Bross, A. D.; Caccianiga, B.; Cavanna, F.; Chun, E. J.; Cleveland, B. T.; Collin, A. P.; Coloma, P.; Conrad, J. M.; Cribier, M.; Cucoanes, A. S.; D'Olivo, J. C.; Das, S.; de Gouvea, A.; Derbin, A. V.; Dharmapalan, R.; Diaz, J. S.; Ding, X. J.; Djurcic, Z.; Donini, A.; Duchesneau, D.; Ejiri, H.; Elliott, S. R.; Ernst, D. J.; Esmaili, A.; Evans, J. J.; Fernandez-Martinez, E.; Figueroa-Feliciano, E.; Fleming, B. T.; Formaggio, J. A.; Franco, D.; Gaffiot, J.; Gandhi, R.; Gao, Y.; Garvey, G. T.; Gavrin, V. N.; Ghoshal, P.; Gibin, D.; Giunti, C.; Gninenko, S. N.; Gorbachev, V. V.; Gorbunov, D. S.; Guenette, R.; Guglielmi, A.; Halzen, F.; Hamann, J.; Hannestad, S.; Haxton, W.; Heeger, K. M.; Henning, R.; Hernandez, P.; Huber, P.; Huelsnitz, W.; Ianni, A.; Ibragimova, T. V.; Karadzhov, Y.; Karagiorgi, G.; Keefer, G.; Kim, Y. D.; Kopp, J.; Kornoukhov, V. N.; Kusenko, A.; Kyberd, P.; Langacker, P.; Lasserre, Th.; Laveder, M.; Letourneau, A.; Lhuillier, D.; Li, Y. F.; Lindner, M.; Link, J. M.; Littlejohn, B. L.; Lombardi, P.; Long, K.; Lopez-Pavon, J.; Louis, W. C.; Ludhova, L.; Lykken, J. D.; Machado, P. A. N.; Maltoni, M.; Mann, W. A.; Marfatia, D.; Mariani, C.; Matveev, V. A.; Mavromatos, N. E.; Melchiorri, A.; Meloni, D.; Mena, O.; Mention, G.; Merle, A.; Meroni, E.; Mezzetto, M.; Mills, G. B.; Minic, D.; Miramonti, L.; Mohapatra, D.; Mohapatra, R. N.; Montanari, C.; Mori, Y.; Mueller, Th. A.; Mumm, H. P.; Muratova, V.; Nelson, A. E.; Nico, J. S.; Noah, E.; Nowak, J.; Smirnov, O. Yu.; Obolensky, M.; Pakvasa, S.; Palamara, O.; Pallavicini, M.; Pascoli, S.; Patrizii, L.; Pavlovic, Z.; Peres, O. L. G.; Pessard, H.; Pietropaolo, F.; Pitt, M. L.; Popovic, M.; Pradler, J.; Ranucci, G.; Ray, H.; Razzaque, S.; Rebel, B.; Robertson, R. G. H.; Rodejohann, W.; Rountree, S. D.; Rubbia, C.; Ruchayskiy, O.; Sala, P. R.; Scholberg, K.; Schwetz, T.; Shaevitz, M. H.; Shaposhnikov, M.; Shrock, R.; Simone, S.; Skorokhvatov, M.; Sorel, M.; Sousa, A.; Spergel, D. N.; Spitz, J.; Stanco, L.; Stancu, I.; Suzuki, A.; Takeuchi, T.; Tamborra, I.; Tang, J.; Testera, G.; Tian, X. C.; Tonazzo, A.; Tunnell, C. D.; Van de Water, R. G.; Verde, L.; Veretenkin, E. P.; Vignoli, C.; Vivier, M.; Vogelaar, R. B.; Wascko, M. O.; Wilkerson, J. F.; Winter, W.; Wong, Y. Y. Y.; Yanagida, T. T.; Yasuda, O.; Yeh, M.; Yermia, F.; Yokley, Z. W.; Zeller, G. P.; Zhan, L.; Zhang, H.
Comments:
Submitted: 2012-04-18
This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.
[7]  oai:arXiv.org:1008.3518  [pdf] - 326586
Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two Liter CF$_3$I Bubble Chamber
Comments: 4 pages, 4 figures V2 submitted to match journal version
Submitted: 2010-08-20, last modified: 2011-03-07
Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during an effective exposure of 28.1 kg-day, consistent with a neutron background. This observation provides the strongest direct detection constraint to date on WIMP-proton spin-dependent scattering for WIMP masses $>20$ GeV/c$^{2}$.