sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Brez, Alessandro

Normalized to: Brez, A.

39 article(s) in total. 744 co-authors, from 1 to 39 common article(s). Median position in authors list is 7,0.

[1]  oai:arXiv.org:1903.01619  [pdf] - 1864023
PolarLight: a CubeSat X-ray Polarimeter based on the Gas Pixel Detector
Comments: Accepted for publication in Experimental Astronomy
Submitted: 2019-03-04
The gas pixel detector (GPD) is designed and developed for high-sensitivity astronomical X-ray polarimetry, which is a new window about to open in a few years. Due to the small mass, low power, and compact geometry of the GPD, we propose a CubeSat mission Polarimeter Light (PolarLight) to demonstrate and test the technology directly in space. There is no optics but a collimator to constrain the field of view to 2.3 degrees. Filled with pure dimethyl ether (DME) at 0.8 atm and sealed by a beryllium window of 100 micron thick, with a sensitive area of about 1.4 mm by 1.4 mm, PolarLight allows us to observe the brightest X-ray sources on the sky, with a count rate of, e.g., ~0.2 counts/s from the Crab nebula. The PolarLight is 1U in size and mounted in a 6U CubeSat, which was launched into a low Earth Sun-synchronous orbit on October 29, 2018, and is currently under test. More launches with improved designs are planned in 2019. These tests will help increase the technology readiness for future missions such as the enhanced X-ray Timing and Polarimetry (eXTP), better understand the orbital background, and may help constrain the physics with observations of the brightest objects.
[2]  oai:arXiv.org:1607.08823  [pdf] - 2064188
eXTP -- enhanced X-ray Timing and Polarimetry Mission
Zhang, S. N.; Feroci, M.; Santangelo, A.; Dong, Y. W.; Feng, H.; Lu, F. J.; Nandra, K.; Wang, Z. S.; Zhang, S.; Bozzo, E.; Brandt, S.; De Rosa, A.; Gou, L. J.; Hernanz, M.; van der Klis, M.; Li, X. D.; Liu, Y.; Orleanski, P.; Pareschi, G.; Pohl, M.; Poutanen, J.; Qu, J. L.; Schanne, S.; Stella, L.; Uttley, P.; Watts, A.; Xu, R. X.; Yu, W. F.; Zand, J. J. M. in 't; Zane, S.; Alvarez, L.; Amati, L.; Baldini, L.; Bambi, C.; Basso, S.; Bhattacharyya, S.; Bellazzini, R.; Belloni, T.; Bellutti, P.; Bianchi, S.; Brez, A.; Bursa, M.; Burwitz, V.; Budtz-Jorgensen, C.; Caiazzo, I.; Campana, R.; Cao, X. L.; Casella, P.; Chen, C. Y.; Chen, L.; Chen, T. X.; Chen, Y.; Chen, Y.; Chen, Y. P.; Civitani, M.; Zelati, F. Coti; Cui, W.; Cui, W. W.; Dai, Z. G.; Del Monte, E.; De Martino, D.; Di Cosimo, S.; Diebold, S.; Dovciak, M.; Donnarumma, I.; Doroshenko, V.; Esposito, P.; Evangelista, Y.; Favre, Y.; Friedrich, P.; Fuschino, F.; Galvez, J. L.; Gao, Z. L.; Ge, M. Y.; Gevin, O.; Goetz, D.; Han, D. W.; Heyl, J.; Horak, J.; Hu, W.; Huang, F.; Huang, Q. S.; Hudec, R.; Huppenkothen, D.; Israel, G. L.; Ingram, A.; Karas, V.; Karelin, D.; Jenke, P. A.; Ji, L.; Kennedy, T.; Korpela, S.; Kunneriath, D.; Labanti, C.; Li, G.; Li, X.; Li, Z. S.; Liang, E. W.; Limousin, O.; Lin, L.; Ling, Z. X.; Liu, H. B.; Liu, H. W.; Liu, Z.; Lu, B.; Lund, N.; Lai, D.; Luo, B.; Luo, T.; Ma, B.; Mahmoodifar, S.; Marisaldi, M.; Martindale, A.; Meidinger, N.; Men, Y. P.; Michalska, M.; Mignani, R.; Minuti, M.; Motta, S.; Muleri, F.; Neilsen, J.; Orlandini, M.; Pan, A T.; Patruno, A.; Perinati, E.; Picciotto, A.; Piemonte, C.; Pinchera, M.; Rachevski, A.; Rapisarda, M.; Rea, N.; Rossi, E. M. R.; Rubini, A.; Sala, G.; Shu, X. W.; Sgro, C.; Shen, Z. X.; Soffitta, P.; Song, L. M.; Spandre, G.; Stratta, G.; Strohmayer, T. E.; Sun, L.; Svoboda, J.; Tagliaferri, G.; Tenzer, C.; Tong, H.; Taverna, R.; Torok, G.; Turolla, R.; Vacchi, A.; Wang, J.; Wang, J. X.; Walton, D.; Wang, K.; Wang, J. F.; Wang, R. J.; Wang, Y. F.; Weng, S. S.; Wilms, J.; Winter, B.; Wu, X.; Wu, X. F.; Xiong, S. L.; Xu, Y. P.; Xue, Y. Q.; Yan, Z.; Yang, S.; Yang, X.; Yang, Y. J.; Yuan, F.; Yuan, W. M.; Yuan, Y. F.; Zampa, G.; Zampa, N.; Zdziarski, A.; Zhang, C.; Zhang, C. L.; Zhang, L.; Zhang, X.; Zhang, Z.; Zhang, W. D.; Zheng, S. J.; Zhou, P.; Zhou, X. L.
Comments: 16 pages, 16 figures. Oral talk presented at SPIE Astronomical Telescopes and Instrumentation, June 26 to July 1, 2016, Edingurgh, UK
Submitted: 2016-07-29
eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time ever the simultaneous spectral-timing-polarimetry studies of cosmic sources in the energy range from 0.5-30 keV (and beyond). Key elements of the payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics for a total effective area of about 0.9 m^2 and 0.6 m^2 at 2 keV and 6 keV respectively, equipped with Silicon Drift Detectors offering <180 eV spectral resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon Drift Detectors, for a total effective area of about 3.4 m^2, between 6 and 10 keV, and spectral resolution <250 eV; the Polarimetry Focusing Array (PFA) - a set of 2 X-ray telescope, for a total effective area of 250 cm^2 at 2 keV, equipped with imaging gas pixel photoelectric polarimeters; the Wide Field Monitor (WFM) - a set of 3 coded mask wide field units, equipped with position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90 degrees FoV. The eXTP international consortium includes mostly major institutions of the Chinese Academy of Sciences and Universities in China, as well as major institutions in several European countries and the United States. The predecessor of eXTP, the XTP mission concept, has been selected and funded as one of the so-called background missions in the Strategic Priority Space Science Program of the Chinese Academy of Sciences since 2011. The strong European participation has significantly enhanced the scientific capabilities of eXTP. The planned launch date of the mission is earlier than 2025.
[3]  oai:arXiv.org:1509.05595  [pdf] - 1323479
Assembly and Test of the Gas Pixel Detector for X-ray Polarimetry
Comments: accepted for publication in Nuclear Instruments and Methods in Physics Research Section A (NIMA)
Submitted: 2015-09-18
The gas pixel detector (GPD) dedicated for photoelectric X-ray polarimetry is selected as the focal plane detector for the ESA medium-class mission concept X-ray Imaging and Polarimetry Explorer (XIPE). Here we show the design, assembly, and preliminary test results of a small GPD for the purpose of gas mixture optimization needed for the phase A study of XIPE. The detector is assembled in house at Tsinghua University following a design by the INFN-Pisa group. The improved detector design results in a good uniformity for the electric field. Filled with pure dimethyl ether (DME) at 0.8 atm, the measured energy resolution is 18% at 6 keV and inversely scales with the square root of the X-ray energy. The measured modulation factor is well consistent with that from simulation, up to ~0.6 above 6 keV. The residual modulation is found to be 0.30% +/- 0.15% at 6 keV for the whole sensitive area, which can be translated into a systematic error of less than 1% for polarization measurement at a confidence level of 99%. The position resolution of the detector is about 80 um in FWHM, consistent with previous studies and sufficient for XIPE requirements.
[4]  oai:arXiv.org:1509.04392  [pdf] - 1277254
LAMP: a micro-satellite based soft X-ray polarimeter for astrophysics
Comments:
Submitted: 2015-09-15
The Lightweight Asymmetry and Magnetism Probe (LAMP) is a micro-satellite mission concept dedicated for astronomical X-ray polarimetry and is currently under early phase study. It consists of segmented paraboloidal multilayer mirrors with a collecting area of about 1300 cm^2 to reflect and focus 250 eV X-rays, which will be detected by position sensitive detectors at the focal plane. The primary targets of LAMP include the thermal emission from the surface of pulsars and synchrotron emission produced by relativistic jets in blazars. With the expected sensitivity, it will allow us to detect polarization or place a tight upper limit for about 10 pulsars and 20 blazars. In addition to measuring magnetic structures in these objects, LAMP will also enable us to discover bare quark stars if they exist, whose thermal emission is expected to be zero polarized, while the thermal emission from neutron stars is believed to be highly polarized due to plasma polarization and the quantum electrodynamics (QED) effect. Here we present an overview of the mission concept, its science objectives and simulated observational results.
[5]  oai:arXiv.org:1403.7200  [pdf] - 1208656
The imaging properties of the Gas Pixel Detector as a focal plane polarimeter
Comments: Accepted for publication in The Astrophysical Journal Supplement
Submitted: 2014-03-27
X-rays are particularly suited to probe the physics of extreme objects. However, despite the enormous improvements of X-ray Astronomy in imaging, spectroscopy and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate to fill the gap of more than thirty years of lack of measurements. The GPD, in the focus of a telescope, will increase the sensitivity of orders of magnitude. Moreover, since it can measure the energy, the position, the arrival time and the polarization angle of every single photon, allows to perform polarimetry of subsets of data singled out from the spectrum, the light curve or the image of source. The GPD has an intrinsic very fine imaging capability and in this work we report on the calibration campaign carried out in 2012 at the PANTER X-ray test facility of the Max-Planck-Institut f\"ur extraterrestrische Physik of Garching (Germany) in which, for the first time, we coupled it to a JET-X optics module with a focal length of 3.5 m and an angular resolution of 18 arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small mission. We derived the imaging and polarimetric performance for extended sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the XIPE configuration, discussing also possible improvements by coupling the detector with advanced optics, having finer angular resolution and larger effective area, to study with more details extended objects.
[6]  oai:arXiv.org:1311.2220  [pdf] - 786443
Re-testing the JET-X Flight Module No. 2 at the PANTER facility
Comments: Author's accepted manuscript posted to arXiv.org as permitted by Springer's Self-Archiving Policy. The final publication is available at http://rd.springer.com/article/10.1007%2Fs10686-013-9365-y
Submitted: 2013-11-09, last modified: 2014-02-18
The Joint European X-ray Telescope (JET-X) was the core instrument of the Russian Spectrum-X-gamma space observatory. It consisted of two identical soft X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured angular resolution of nearly 15 arcsec. Soon after the payload completion, the mission was cancelled and the two optical flight modules (FM) were brought to the Brera Astronomical Observatory where they had been manufactured. After 16 years of storage, we have utilized the JET-X FM2 to test at the PANTER X-ray facility a prototype of a novel X-ray polarimetric telescope, using a Gas Pixel Detector (GPD) with polarimetric capabilities in the focal plane of the FM2. The GPD was developed by a collaboration between INFN-Pisa and INAF-IAPS. In the first phase of the test campaign, we have re-tested the FM2 at PANTER to have an up-to-date characterization in terms of angular resolution and effective area, while in the second part of the test the GPD has been placed in the focal plane of the FM2. In this paper we report the results of the tests of the sole FM2, using an unpolarized X-ray source, comparing the results with the calibration done in 1996.
[7]  oai:arXiv.org:1309.6995  [pdf] - 1453148
XIPE: the X-ray Imaging Polarimetry Explorer
Soffitta, Paolo; Barcons, Xavier; Bellazzini, Ronaldo; Braga, João; Costa, Enrico; Fraser, George W.; Gburek, Szymon; Huovelin, Juhani; Matt, Giorgio; Pearce, Mark; Poutanen, Juri; Reglero, Victor; Santangelo, Andrea; Sunyaev, Rashid A.; Tagliaferri, Gianpiero; Weisskopf, Martin; Aloisio, Roberto; Amato, Elena; Attiná, Primo; Axelsson, Magnus; Baldini, Luca; Basso, Stefano; Bianchi, Stefano; Blasi, Pasquale; Bregeon, Johan; Brez, Alessandro; Bucciantini, Niccoló; Burderi, Luciano; Burwitz, Vadim; Casella, Piergiorgio; Churazov, Eugene; Civitani, Marta; Covino, Stefano; da Silva, Rui Miguel Curado; Cusumano, Giancarlo; Dadina, Mauro; D'Amico, Flavio; De Rosa, Alessandra; Di Cosimo, Sergio; Di Persio, Giuseppe; Di Salvo, Tiziana; Dovciak, Michal; Elsner, Ronald; Eyles, Chris J.; Fabian, Andrew C.; Fabiani, Sergio; Feng, Hua; Giarrusso, Salvatore; Goosmann, René W.; Grandi, Paola; Grosso, Nicolas; Israel, Gianluca; Jackson, Miranda; Kaaret, Philip; Karas, Vladimir; Kuss, Michael; Lai, Dong; La Rosa, Giovanni; Larsson, Josefin; Larsson, Stefan; Latronico, Luca; Maggio, Antonio; Maia, Jorge; Marin, Frédéric; Massai, Marco Maria; Mineo, Teresa; Minuti, Massimo; Moretti, Elena; Muleri, Fabio; O'Dell, Stephen L.; Pareschi, Giovanni; Peres, Giovanni; Pesce, Melissa; Petrucci, Pierre-Olivier; Pinchera, Michele; Porquet, Delphine; Ramsey, Brian; Rea, Nanda; Reale, Fabio; Rodrigo, Juana Maria; Różańska, Agata; Rubini, Alda; Rudawy, Pawel; Ryde, Felix; Salvati, Marco; Júnior, Valdivino Alexandre de Santiago; Sazonov, Sergey; Sgró, Carmelo; Silver, Eric; Spandre, Gloria; Spiga, Daniele; Stella, Luigi; Tamagawa, Toru; Tamborra, Francesco; Tavecchio, Fabrizio; Dias, Teresa Teixeira; van Adelsberg, Matthew; Wu, Kinwah; Zane, Silvia
Comments: 49 pages, 14 figures, 6 tables. Paper published in Experimental Astronomy http://link.springer.com/journal/10686
Submitted: 2013-09-26
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017 but not selected. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus and two additional GPDs filled with pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 % at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil).
[8]  oai:arXiv.org:1208.6330  [pdf] - 1151008
Measurement of the position resolution of the Gas Pixel Detector
Comments: Submitted to Nuclear Instruments and Methods in Physics Research Section A; 15 figures, 3 tables
Submitted: 2012-08-30
The Gas Pixel Detector was designed and built as a focal plane instrument for X-ray polarimetry of celestial sources, the last unexplored subtopics of X-ray astronomy. It promises to perform detailed and sensitive measurements resolving extended sources and detecting polarization in faint sources in crowded fields at the focus of telescopes of good angular resolution. Its polarimetric and spectral capability were already studied in earlier works. Here we investigate for the first time, with both laboratory measurements and Monte Carlo simulations, its imaging properties to confirm its unique capability to carry out imaging spectral-polarimetry in future X-ray missions.
[9]  oai:arXiv.org:1111.6391  [pdf] - 444318
The gas pixel detector as a solar X-ray polarimeter and imager
Comments: J. Adv. Space Res. (2011)
Submitted: 2011-11-28
The Sun is the nearest astrophysical source with a very intense emission in the X-ray band. The study of energetic events, such as solar flares, can help us to understand the behaviour of the magnetic field of our star. There are in the literature numerous studies published about polarization predictions, for a wide range of solar flares models involving the emission from thermal and/or non-thermal processes, but observations in the X-ray band have never been exhaustive. The gas pixel detector (GPD) was designed to achieve X-ray polarimetric measurements as well as X-ray images for far astrophysical sources. Here we present the possibility to employ this instrument for the observation of our Sun in the X-ray band.
[10]  oai:arXiv.org:1111.3331  [pdf] - 554250
Simultaneous multi-wavelength campaign on PKS 2005-489 in a high state
Collaboration, The H. E. S. S.; Collaboration, the Fermi LAT; :; Abramowski, A.; Acero, F.; Aharonian, F.; Akhperjanian, A. G.; Anton, G.; Barnacka, A.; de Almeida, U. Barres; Bazer-Bachi, A. R.; Becherini, Y.; Becker, J.; Behera, B.; Bernlöhr, K.; Bochow, A.; Boisson, C.; Bolmont, J.; Bordas, P.; Borrel, V.; Brucker, J.; Brun, F.; Brun, P.; Bulik, T.; Büsching, I.; Casanova, S.; Cerruti, M.; Chadwick, P. M.; Charbonnier, A.; Chaves, R. C. G.; Cheesebrough, A.; Chounet, L. -M.; Clapson, A. C.; Coignet, G.; Conrad, J.; Dalton, M.; Daniel, M. K.; Davids, I. D.; Degrange, B.; Deil, C.; Dickinson, H. J.; Djannati-Ataï, A.; Domainko, W.; Drury, L. O'C.; Dubois, F.; Dubus, G.; Dyks, J.; Dyrda, M.; Egberts, K.; Eger, P.; Espigat, P.; Fallon, L.; Farnier, C.; Fegan, S.; Feinstein, F.; Fernandes, M. V.; Fiasson, A.; Fontaine, G.; Förster, A.; Füßling, M.; Gabici, S.; Gallant, Y. A.; Gast, H.; Gérard, L.; Gerbig, D.; Giebels, B.; Glicenstein, J. F.; Glück, B.; Goret, P.; Göring, D.; Hague, J. D.; Hampf, D.; Hauser, M.; Heinz, S.; Heinzelmann, G.; Henri, G.; Hermann, G.; Hinton, J. A.; Hoffmann, A.; Hofmann, W.; Hofverberg, P.; Horns, D.; Jacholkowska, A.; de Jager, O. C.; Jahn, C.; Jamrozy, M.; Jung, I.; Kastendieck, M. A.; Katarzyński, K.; Katz, U.; Kaufmann, S.; Keogh, D.; Kerschhaggl, M.; Khangulyan, D.; Khélifi, B.; Klochkov, D.; Kluźniak, W.; Kneiske, T.; Komin, Nu.; Kosack, K.; Kossakowski, R.; Laffon, H.; Lamanna, G.; Lenain, J. -P.; Lennarz, D.; Lohse, T.; Lopatin, A.; Lu, C. -C.; Marandon, V.; Marcowith, A.; Masbou, J.; Maurin, D.; Maxted, N.; McComb, T. J. L.; Medina, M. C.; Méhault, J.; Nguyen, N.; Moderski, R.; Moulin, E.; Naumann-Godo, M.; de Naurois, M.; Nedbal, D.; Nekrassov, D.; Nicholas, B.; Niemiec, J.; Nolan, S. J.; Ohm, S.; Olive, J-F.; Wilhelmi, E. de Oña; Opitz, B.; Ostrowski, M.; Panter, M.; Arribas, M. Paz; Pedaletti, G.; Pelletier, G.; Petrucci, P. -O.; Pita, S.; Pühlhofer, G.; Punch, M.; Quirrenbach, A.; Raue, M.; Rayner, S. M.; Reimer, A.; Reimer, O.; Renaud, M.; Reyes, R. de los; Rieger, F.; Ripken, J.; Rob, L.; Rosier-Lees, S.; Rowell, G.; Rudak, B.; Rulten, C. B.; Ruppel, J.; Ryde, F.; Sahakian, V.; Santangelo, A.; Schlickeiser, R.; Schöck, F. M.; Schönwald, A.; Schwanke, U.; Schwarzburg, S.; Schwemmer, S.; Shalchi, A.; Sikora, M.; Skilton, J. L.; Sol, H.; Spengler, G.; Stawarz, Ł.; Steenkamp, R.; Stegmann, C.; Stinzing, F.; Sushch, I.; Szostek, A.; Tam, P. H.; Tavernet, J. -P.; Terrier, R.; Tibolla, O.; Tluczykont, M.; Valerius, K.; van Eldik, C.; Vasileiadis, G.; Venter, C.; Vialle, J. P.; Viana, A.; Vincent, P.; Vivier, M.; Völk, H. J.; Volpe, F.; Vorobiov, S.; Vorster, M.; Wagner, S. J.; Ward, M.; Wierzcholska, A.; Zajczyk, A.; Zdziarski, A. A.; Zech, A.; Zechlin, H. -S.; Abdo, A. A.; Ackermann, M.; Ajello, M.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Blandford, R. D.; Bonamente, E.; Borgland, A. W.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Buehler, R.; Buson, S.; Caliandro, G. A.; Cameron, R. A.; Cannon, A.; Caraveo, P. A.; Carrigan, S.; Casandjian, J. M.; Cavazzuti, E.; Cecchi, C.; Çelik, Ö.; Chekhtman, A.; Cheung, C. C.; Chiang, J.; Ciprini, S.; Claus, R.; Cohen-Tanugi, J.; Cutini, S.; Dermer, C. D.; de Palma, F.; Silva, E. do Couto e; Drell, P. S.; Dubois, R.; Dumora, D.; Escande, L.; Favuzzi, C.; Ferrara, E. C.; Focke, W. B.; Fortin, P.; Frailis, M.; Fukazawa, Y.; Fusco, P.; Gargano, F.; Gasparrini, D.; Gehrels, N.; Germani, S.; Giglietto, N.; Giommi, P.; Giordano, F.; Giroletti, M.; Glanzman, T.; Godfrey, G.; Grenier, I. A.; Grove, J. E.; Guiriec, S.; Hadasch, D.; Hays, E.; Horan, D.; Hughes, R. E.; Jóhannesson, G.; Johnson, A. S.; Johnson, W. N.; Kamae, T.; Katagiri, H.; Kataoka, J.; Knödlseder, J.; Kuss, M.; Lande, J.; Latronico, L.; Lee, S. -H.; Longo, F.; Loparco, F.; Lott, B.; Lovellette, M. N.; Lubrano, P.; Madejski, G. M.; Makeev, A.; Mazziotta, M. N.; McConville, W.; McEnery, J. E.; Michelson, P. F.; Mizuno, T.; Monte, C.; Monzani, M. E.; Morselli, A.; Moskalenko, I. V.; Murgia, S.; Nakamori, T.; Nishino, S.; Nolan, P. L.; Norris, J. P.; Nuss, E.; Ohsugi, T.; Okumura, A.; Omodei, N.; Orlando, E.; Ormes, J. F.; Ozaki, M.; Paneque, D.; Panetta, J. H.; Parent, D.; Pelassa, V.; Pepe, M.; Pesce-Rollins, M.; Piron, F.; Porter, T. A.; Rainò, S.; Rando, R.; Razzano, M.; Sadrozinski, H. F. -W.; Sanchez, D.; Sander, A.; Sgrò, C.; Siskind, E. J.; Smith, P. D.; Spandre, G.; Spinelli, P.; Strickman, M. S.; Suson, D. J.; Takahashi, H.; Takahashi, T.; Tanaka, T.; Thayer, J. B.; Thayer, J. G.; Thompson, D. J.; Tibaldo, L.; Torres, D. F.; Tosti, G.; Tramacere, A.; Troja, E.; Uehara, T.; Usher, T. L.; Vandenbroucke, J.; Vianello, G.; Vilchez, N.; Vitale, V.; Waite, A. P.; Wang, P.; Winer, B. L.; Wood, K. S.; Yang, Z.; Ylinen, T.; Ziegler, M.
Comments: published in A&A, 9pages, 4figures. Due to some style difficulties using the standard style file with the long author list, the abstract has been included manually. A version with the correct style can be found in the website http://www.lsw.uni-heidelberg.de/users/skaufman/publications/aa16170-10published.pdf
Submitted: 2011-11-14
The high-frequency peaked BL Lac object PKS 2005-489 was the target of a multi-wavelength campaign with simultaneous observations in the TeV gamma-ray (H.E.S.S.), GeV gamma-ray (Fermi/LAT), X-ray (RXTE, Swift), UV (Swift) and optical (ATOM, Swift) bands. This campaign was carried out during a high flux state in the synchrotron regime. The flux in the optical and X-ray bands reached the level of the historical maxima. The hard GeV spectrum observed with Fermi/LAT connects well to the very high energy (VHE, E>100GeV) spectrum measured with H.E.S.S. with a peak energy between ~5 and 500 GeV. Compared to observations with contemporaneous coverage in the VHE and X-ray bands in 2004, the X-ray flux was ~50 times higher during the 2009 campaign while the TeV gamma-ray flux shows marginal variation over the years. The spectral energy distribution during this multi-wavelength campaign was fit by a one zone synchrotron self-Compton model with a well determined cutoff in X-rays. The parameters of a one zone SSC model are inconsistent with variability time scales. The variability behaviour over years with the large changes in synchrotron emission and small changes in the inverse Compton emission does not warrant an interpretation within a one-zone SSC model despite an apparently satisfying fit to the broadband data in 2009.
[11]  oai:arXiv.org:1108.0501  [pdf] - 1083136
The radio/gamma-ray connection in Active Galactic Nuclei in the era of the Fermi Large Area Telescope
Ackermann, M.; Ajello, M.; Allafort, A.; Angelakis, E.; Axelsson, M.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bellazzini, R.; Berenji, B.; Blandford, R. D.; Bloom, E. D.; Bonamente, E.; Borgland, A. W.; Bouvier, A.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Buehler, R.; Buson, S.; Caliandro, G. A.; Cameron, R. A.; Cannon, A.; Caraveo, P. A.; Casandjian, J. M.; Cavazzuti, E.; Cecchi, C.; Charles, E.; Chekhtman, A.; Cheung, C. C.; Ciprini, S.; Claus, R.; Cohen-Tanugi, J.; Cutini, S.; de Palma, F.; Dermer, C. D.; Silva, E. do Couto e; Drell, P. S.; Dubois, R.; Dumora, D.; Escande, L.; Favuzzi, C.; Fegan, S. J.; Focke, W. B.; Fortin, P.; Frailis, M.; Fuhrmann, L.; Fukazawa, Y.; Fusco, P.; Gargano, F.; Gasparrini, D.; Gehrels, N.; Giglietto, N.; Giommi, P.; Giordano, F.; Giroletti, M.; Glanzman, T.; Godfrey, G.; Grandi, P.; Grenier, I. A.; Guiriec, S.; Hadasch, D.; Hayashida, M.; Hays, E.; Healey, S. E.; J, G.; Johnson, A. S.; Kamae, T.; Katagiri, H.; Kataoka, J.; Kn, J.; Kuss, M.; Lande, J.; Lee, S. -H.; Longo, F.; Loparco, F.; Lott, B.; Lovellette, M. N.; Lubrano, P.; Makeev, A.; Max-Moerbeck, W.; Mazziotta, M. N.; McEnery, J. E.; Mehault, J.; Michelson, P. F.; Mizuno, T.; Monte, C.; Monzani, M. E.; Morselli, A.; Moskalenko, I. V.; Murgia, S.; Naumann-Godo, M.; Nishino, S.; Nolan, P. L.; Norris, J. P.; Nuss, E.; Ohsugi, T.; Okumura, A.; Omodei, N.; Orlando, E.; Ormes, J. F.; Ozaki, M.; Paneque, D.; Pavlidou, V.; Pelassa, V.; Pepe, M.; Pesce-Rollins, M.; Pierbattista, M.; Piron, F.; Porter, T. A.; Rain, S.; Razzano, M.; Readhead, A.; Reimer, A.; Reimer, O.; Richards, J. L.; Romani, R. W.; Sadrozinski, H. F. -W.; Scargle, J. D.; Sgr, C.; Siskind, E. J.; Smith, P. D.; Spandre, G.; Spinelli, P.; Strickman, M. S.; Suson, D. J.; Takahashi, H.; Tanaka, T.; Taylor, G. B.; Thayer, J. G.; Thayer, J. B.; Thompson, D. J.; Torres, D. F.; Tosti, G.; Tramacere, A.; Troja, E.; Vandenbroucke, J.; Vianello, G.; Vitale, V.; Waite, A. P.; Wang, P.; Winer, B. L.; Wood, K. S.; Yang, Z.; Ziegler, M.
Comments: Accepted for publications by ApJ. Contact authors: M. Giroletti, V. Pavlidou, A. Reimer
Submitted: 2011-08-02
We present a detailed statistical analysis of the correlation between radio and gamma-ray emission of the Active Galactic Nuclei (AGN) detected by Fermi during its first year of operation, with the largest datasets ever used for this purpose. We use both archival interferometric 8.4 GHz data (from the VLA and ATCA, for the full sample of 599 sources) and concurrent single-dish 15 GHz measurements from the Owens Valley Radio Observatory (OVRO, for a sub sample of 199 objects). Our unprecedentedly large sample permits us to assess with high accuracy the statistical significance of the correlation, using a surrogate-data method designed to simultaneously account for common-distance bias and the effect of a limited dynamical range in the observed quantities. We find that the statistical significance of a positive correlation between the cm radio and the broad band (E>100 MeV) gamma-ray energy flux is very high for the whole AGN sample, with a probability <1e-7 for the correlation appearing by chance. Using the OVRO data, we find that concurrent data improve the significance of the correlation from 1.6e-6 to 9.0e-8. Our large sample size allows us to study the dependence of correlation strength and significance on specific source types and gamma-ray energy band. We find that the correlation is very significant (chance probability <1e-7) for both FSRQs and BL Lacs separately; a dependence of the correlation strength on the considered gamma-ray energy band is also present, but additional data will be necessary to constrain its significance.
[12]  oai:arXiv.org:1105.0637  [pdf] - 353860
POLARIX: a pathfinder mission of X-ray polarimetry
Comments: 42 pages, 28 figures
Submitted: 2011-05-03
Since the birth of X-ray astronomy, spectral, spatial and timing observation improved dramatically, procuring a wealth of information on the majority of the classes of the celestial sources. Polarimetry, instead, remained basically unprobed. X-ray polarimetry promises to provide additional information procuring two new observable quantities, the degree and the angle of polarization. POLARIX is a mission dedicated to X-ray polarimetry. It exploits the polarimetric response of a Gas Pixel Detector, combined with position sensitivity, that, at the focus of a telescope, results in a huge increase of sensitivity. Three Gas Pixel Detectors are coupled with three X-ray optics which are the heritage of JET-X mission. POLARIX will measure time resolved X-ray polarization with an angular resolution of about 20 arcsec in a field of view of 15 arcmin $\times$ 15 arcmin and with an energy resolution of 20 % at 6 keV. The Minimum Detectable Polarization is 12 % for a source having a flux of 1 mCrab and 10^5 s of observing time. The satellite will be placed in an equatorial orbit of 505 km of altitude by a Vega launcher.The telemetry down-link station will be Malindi. The pointing of POLARIX satellite will be gyroless and it will perform a double pointing during the earth occultation of one source, so maximizing the scientific return. POLARIX data are for 75 % open to the community while 25 % + SVP (Science Verification Phase, 1 month of operation) is dedicated to a core program activity open to the contribution of associated scientists. The planned duration of the mission is one year plus three months of commissioning and SVP, suitable to perform most of the basic science within the reach of this instrument.
[13]  oai:arXiv.org:1012.4658  [pdf] - 1042704
Radio and Gamma-Ray Constraints on the Emission Geometry and Birthplace of PSR J2043+2740
Noutsos, A.; Abdo, A. A.; Ackermann, M.; Ajello, M.; Ballet, J.; Barbiellini, G.; Baring, M. G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Bonamente, E.; Borgland, A. W.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Buehler, R.; Busetto, G.; Caliandro, G. A.; Cameron, R. A.; Camilo, F.; Caraveo, P. A.; Casandjian, J. M.; Cecchi, C.; Celik, O.; Chaty, S.; Chekhtman, A.; Chiang, J.; Ciprini, S.; Claus, R.; Cognard, I.; Cohen-Tanugi, J.; Colafrancesco, S.; Cutini, S.; Dermer, C. D.; de Palma, F.; Drell, P. S.; Dumora, D.; Espinoza, C. M.; Favuzzi, C.; Ferrara, E. C.; Focke, W. B.; Frailis, M.; Freire, P. C. C.; Fukazawa, Y.; Funk, S.; Fusco, P.; Gargano, F.; Germani, S.; Giglietto, N.; Giordano, F.; Giroletti, M.; Godfrey, G.; Grandi, P.; Grenier, I. A.; Grove, J. E.; Guillemot, L.; Guiriec, S.; Harding, A. K.; Hughes, R. E.; Jackson, M. S.; Johannesson, G.; Johnson, A. S.; Johnson, T. J.; Johnson, W. N.; Johnston, S.; Kamae, T.; Katagiri, H.; Kataoka, J.; Knoedlseder, J.; Kramer, M.; Kuss, M.; Lande, J.; Lee, S. -H.; Longo, F.; Loparco, F.; Lovellette, M. N.; Lubrano, P.; Lyne, A. G.; Makeev, A.; Marelli, M.; Mazziotta, M. N.; McEnery, J. E.; Mehault, J.; Michelson, P. F.; Mizuno, T.; Monte, C.; Monzani, M. E.; Morselli, A.; Moskalenko, I. V.; Murgia, S.; Naumann-Godo, M.; Nolan, P. L.; Nuss, E.; Ohsugi, T.; Okumura, A.; Omodei, N.; Orlando, E.; Ormes, J. F.; Panetta, J. H.; Parent, D.; Pelassa, V.; Pepe, M.; Persic, M.; Pesce-Rollins, M.; Piron, F.; Porter, T. A.; Rain, S.; Ray, P. S.; Razzano, M.; Reimer, A.; Reimer, O.; Reposeur, T.; Romani, R. W.; Sadrozinski, H. F. -W.; Sander, A.; Parkinson, P. M. Saz; Sgro, C.; Siskind, E. J.; Smith, D. A.; Smith, P. D.; Spandre, G.; Spinelli, P.; Stappers, B. W.; Strickman, M. S.; Suson, D. J.; Takahashi, H.; Tanaka, T.; Theureau, G.; Thompson, D. J.; Thorsett, S. E.; Tibolla, O.; Torres, D. F.; Tramacere, A.; Usher, T. L.; Vandenbroucke, J.; Vianello, G.; Vilchez, N.; Villata, M.; Vitale, V.; von Kienlin, A.; Waite, A. P.; Wang, P.; Watters, K.; Weltevrede, P.; Winer, B. L.; Wood, K. S.; Ziegler, M.
Comments: 17 pages, 6 figures, Accepted for publication in ApJ
Submitted: 2010-12-21
We report on the first year of Fermi gamma-ray observations of pulsed high-energy emission from the old PSR J2043+2740. The study of the gamma-ray efficiency of such old pulsars gives us an insight into the evolution of pulsars' ability to emit in gammma rays as they age. The gamma-ray lightcurve of this pulsar above 0.1 GeV is clearly defined by two sharp peaks, 0.353+/-0.035 periods apart. We have combined the gamma-ray profile characteristics of PSR J2043+2740 with the geometrical properties of the pulsar's radio emission, derived from radio polarization data, and constrained the pulsar-beam geometry in the framework of a Two Pole Caustic and an Outer Gap model. The ranges of magnetic inclination and viewing angle were determined to be {alpha,zeta}~{52-57,61-68} for the Two Pole Caustic model, and {alpha,zeta}~{62-73,74-81} and {alpha,zeta}~{72-83,60-75} for the Outer Gap model. Based on this geometry, we assess possible birth locations for this pulsar and derive a likely proper motion, sufficiently high to be measurable with VLBI. At a characteristic age of 1.2 Myr, PSR J2043+2740 is the third oldest of all discovered, non-recycled, gamma-ray pulsars: it is twice as old as the next oldest, PSR J0357+32, and younger only than the recently discovered PSR J1836+5925 and PSR J2055+25, both of which are at least 5 and 10 times less energetic, respectively.
[14]  oai:arXiv.org:1003.6009  [pdf] - 1026036
Spectral and polarimetric characterization of the Gas Pixel Detector filled with dimethyl ether
Comments: 20 pages, 11 figures, 5 tables. Accepted for publication by NIMA
Submitted: 2010-03-31
The Gas Pixel Detector belongs to the very limited class of gas detectors optimized for the measurement of X-ray polarization in the emission of astrophysical sources. The choice of the mixture in which X-ray photons are absorbed and photoelectrons propagate, deeply affects both the energy range of the instrument and its performance in terms of gain, track dimension and ultimately, polarimetric sensitivity. Here we present the characterization of the Gas Pixel Detector with a 1 cm thick cell filled with dimethyl ether (DME) at 0.79 atm, selected among other mixtures for the very low diffusion coefficient. Almost completely polarized and monochromatic photons were produced at the calibration facility built at INAF/IASF-Rome exploiting Bragg diffraction at nearly 45 degrees. For the first time ever, we measured the modulation factor and the spectral capabilities of the instrument at energies as low as 2.0 keV, but also at 2.6 keV, 3.7 keV, 4.0 keV, 5.2 keV and 7.8 keV. These measurements cover almost completely the energy range of the instrument and allows to compare the sensitivity achieved with that of the standard mixture, composed of helium and DME.
[15]  oai:arXiv.org:1002.4415  [pdf] - 1025345
Constraints on Cosmological Dark Matter Annihilation from the Fermi-LAT Isotropic Diffuse Gamma-Ray Measurement
collaboration, The Fermi-LAT; :; Abdo, A. A.; Ackermann, M.; Ajello, M.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Blandford, R. D.; Bloom, E. D.; Bonamente, E.; Borgland, A. W.; Bouvier, A.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Burnett, T. H.; Buson, S.; Caliandro, G. A.; Cameron, R. A.; Caraveo, P. A.; Carrigan, S.; Casandjian, J. M.; Cecchi, C.; Elik, O. C.; Chekhtman, A.; Cheung, C. C.; Chiang, J.; Ciprini, S.; Claus, R.; Cohen-Tanugi, J.; Conrad, J.; Cutini, S.; Dermer, C. D.; de Angelis, A.; de Palma, F.; Digel, S. W.; Silva, E. do Couto e; Drell, P. S.; Dubois, R.; Dumora, D.; Edmonds, Y.; Farnier, C.; Favuzzi, C.; Fegan, S. J.; Focke, W. B.; Fortin, P.; Frailis, M.; Fukazawa, Y.; Fusco, P.; Gargano, F.; Gasparrini, D.; Gehrels, N.; Germani, S.; Giglietto, N.; Giordano, F.; Glanzman, T.; Godfrey, G.; Grove, J. E.; Guillemot, L.; Guiriec, S.; Gustafsson, M.; Hadasch, D.; Harding, A. K.; Horan, D.; Hughes, R. E.; Johnson, A. S.; Johnson, W. N.; Kamae, T.; Katagiri, H.; Kataoka, J.; Kawai, N.; Kerr, M.; Knodlseder, J.; Kuss, M.; Lande, J.; Latronico, L.; Garde, M. Llena; Longo, F.; Loparco, F.; Lott, B.; Lovellette, M. N.; Lubrano, P.; Makeev, A.; Mazziotta, M. N.; McEnery, J. E.; Meurer, C.; Michelson, P. F.; Mitthumsiri, W.; Mizuno, T.; Monte, C.; Monzani, M. E.; Morselli, A.; Moskalenko, I. V.; Murgia, S.; Nolan, P. L.; Norris, J. P.; Nuss, E.; Ohsugi, T.; Omodei, N.; Orlando, E.; Ormes, J. F.; Paneque, D.; Panetta, J. H.; Parent, D.; Pelassa, V.; Pepe, M.; Pesce-Rollins, M.; Piron, F.; Raino, S.; Rando, R.; Reimer, A.; Reimer, O.; Reposeur, T.; Rodriguez, A. Y.; Roth, M.; Sadrozinski, H. F. W.; Sander, A.; Parkinson, P. M. Saz; Scargle, J. D.; Sellerholm, A.; Sgro, C.; Siskind, E. J.; Smith, P. D.; Spandre, G.; Spinelli, P.; Starck, J. L.; Strickman, M. S.; Suson, D. J.; Takahashi, H.; Tanaka, T.; Thayer, J. B.; Thayer, J. G.; Torres, D. F.; Uchiyama, Y.; Usher, T. L.; Vasileiou, V.; Vilchez, N.; Vitale, V.; Waite, A. P.; Wang, P.; Winer, B. L.; Wood, K. S.; Ylinen, T.; Zaharijas, G.; Ziegle, M.
Comments: 29 pages, 7 figures, to be published in JCAP. Corresponding authors: Jan Conrad, Michael Gustafsson, Alexander Sellerholm, Gabrijela Zaharijas
Submitted: 2010-02-24
The first published Fermi large area telescope (Fermi-LAT) measurement of the isotropic diffuse gamma-ray emission is in good agreement with a single power law, and is not showing any signature of a dominant contribution from dark matter sources in the energy range from 20 to 100 GeV. We use the absolute size and spectral shape of this measured flux to derive cross section limits on three types of generic dark matter candidates: annihilating into quarks, charged leptons and monochromatic photons. Predicted gamma-ray fluxes from annihilating dark matter are strongly affected by the underlying distribution of dark matter, and by using different available results of matter structure formation we assess these uncertainties. We also quantify how the dark matter constraints depend on the assumed conventional backgrounds and on the Universe's transparency to high-energy gamma-rays. In reasonable background and dark matter structure scenarios (but not in all scenarios we consider) it is possible to exclude models proposed to explain the excess of electrons and positrons measured by the Fermi-LAT and PAMELA experiments. Derived limits also start to probe cross sections expected from thermally produced relics (e.g. in minimal supersymmetry models) annihilating predominantly into quarks. For the monochromatic gamma-ray signature, the current measurement constrains only dark matter scenarios with very strong signals.
[16]  oai:arXiv.org:1001.4836  [pdf] - 511724
Fermi LAT Search for Photon Lines from 30 to 200 GeV and Dark Matter Implications
The Fermi LAT Collaboration; Abdo, A. A.; Ackermann, M.; Ajello, M.; Atwood, W. B.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Bloom, E. D.; Bonamente, E.; Borgland, A. W.; Bouvier, A.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Burnett, T. H.; Buson, S.; Caliandro, G. A.; Cameron, R. A.; Caraveo, P. A.; Carrigan, S.; Casandjian, J. M.; Cecchi, C.; Elik, O. C.; Chekhtman, A.; Chiang, J.; Ciprini, S.; Claus, R.; Cohen-Tanugi, J.; Conrad, J.; Dermer, C. D.; de Angelis, A.; de Palma, F.; Digel, S. W.; Silva, E. do Couto e; Drell, P. S.; Drlica-Wagner, A.; Dubois, R.; Dumora, D.; Edmonds, Y.; Essig, R.; Farnier, C.; Favuzzi, C.; Fegan, S. J.; Focke, W. B.; Fortin, P.; Frailis, M.; Fukazawa, Y.; Funk, S.; Fusco, P.; Gargano, F.; Gasparrini, D.; Gehrels, N.; Germani, S.; Giglietto, N.; Giordano, F.; Glanzman, T.; Godfrey, G.; Grenier, I. A.; Grove, J. E.; Guillemot, L.; Guiriec, S.; Gustafsson, M.; Hadasch, D.; Harding, A. K.; Horan, D.; Hughes, R. E.; Jackson, M. S.; ohannesson, G. J .; Johnson, A. S.; Johnson, R. P.; Johnson, W. N.; Kamae, T.; Katagiri, H.; Kataoka, J.; Kawai, N.; Kerr, M.; dlseder, J. Kno .; Kuss, M.; Lande, J.; Latronico, L.; Garde, M. Llena; Longo, F.; Loparco, F.; Lott, B.; Lovellette, M. N.; Lubrano, P.; Makeev, A.; Mazziotta, M. N.; McEnery, J. E.; Meurer, C.; Michelson, P. F.; Mitthumsiri, W.; Mizuno, T.; Moiseev, A. A.; Monte, C.; Monzani, M. E.; Morselli, A.; Moskalenko, I. V.; Murgia, S.; Nolan, P. L.; Norris, J. P.; Nuss, E.; Ohsugi, T.; Omodei, N.; Orlando, E.; Ormes, J. F.; Ozaki, M.; Paneque, D.; Panetta, J. H.; Parent, D.; Pelassa, V.; Pepe, M.; Pesce-Rollins, M.; Piron, F.; Rainó, S.; Rando, R.; Razzano, M.; Reimer, A.; Reimer, O.; Reposeur, T.; Ripken, J.; Ritz, S.; Rodriguez, A. Y.; Roth, M.; Sadrozinski, H. F. -W.; Sander, A.; Parkinson, P. M. Saz; Scargle, J. D.; Schalk, T. L.; Sellerholm, A.; Sgró, C.; Siskind, E. J.; Smith, D. A.; Smith, P. D.; Spandre, G.; Spinelli, P.; Starck, J. -L.; Strickman, M. S.; Suson, D. J.; Tajima, H.; Takahashi, H.; Tanaka, T.; Thayer, J. B.; Thayer, J. G.; Tibaldo, L.; Torres, D. F.; Uchiyama, Y.; Usher, T. L.; Vasileiou, V.; Vilchez, N.; Vitale, V.; Waite, A. P.; Wang, P.; Winer, B. L.; Wood, K. S.; Ylinen, T.; Ziegler, M.
Comments: 6 pages, 1 figure. Accepted for publication by The Physical Review Letters
Submitted: 2010-01-26
Dark matter (DM) particle annihilation or decay can produce monochromatic $\gamma$-rays readily distinguishable from astrophysical sources. $\gamma$-ray line limits from 30 GeV to 200 GeV obtained from 11 months of Fermi Large Area Space Telescope data from 20-300 GeV are presented using a selection based on requirements for a $\gamma$-ray line analysis, and integrated over most of the sky. We obtain $\gamma$-ray line flux upper limits in the range $0.6-4.5\times 10^{-9}\mathrm{cm}^{-2}\mathrm{s}^{-1}$, and give corresponding DM annihilation cross-section and decay lifetime limits. Theoretical implications are briefly discussed.
[17]  oai:arXiv.org:1001.4531  [pdf] - 1943080
Observations of Milky Way Dwarf Spheroidal galaxies with the Fermi-LAT detector and constraints on Dark Matter models
Collaboration, Fermi-LAT; :; Abdo, A. A.; Ackermann, M.; Ajello, M.; Atwood, W. B.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Bloom, E. D.; Bonamente, E.; Borgland, A. W.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Burnett, T. H.; Buson, S.; Caliandro, G. A.; Cameron, R. A.; Caraveo, P. A.; Casandjian, J. M.; Cecchi, C.; Chekhtman, A.; Cheung, C. C.; Chiang, J.; Ciprini, S.; Claus, R.; Cohen-Tanugi, J.; Conrad, J.; de Angelis, A.; de Palma, F.; Digel, S. W.; Silva, E. do Couto e; Drell, P. S.; Drlica-Wagner, A.; Dubois, R.; Dumora, D.; Farnier, C.; Favuzzi, C.; Fegan, S. J.; Focke, W. B.; Fortin, P.; Frailis, M.; Fukazawa, Y.; Fusco, P.; Gargano, F.; Gehrels, N.; Germani, S.; Giebels, B.; Giglietto, N.; Giordano, F.; Glanzman, T.; Godfrey, G.; Grenier, I. A.; Grove, J. E.; Guillemot, L.; Guiriec, S.; Gustafsson, M.; Harding, A. K.; Hays, E.; Horan, D.; Hughes, R. E.; Jackson, M. S.; Jeltema, T. E.; Johannesson, G.; Johnson, A. S.; Johnson, R. P.; Johnson, W. N.; Kamae, T.; Katagiri, H.; Kataoka, J.; Kerr, M.; Knodlseder, J.; Kuss, M.; Lande, J.; Latronico, L.; Lemoine-Goumard, M.; Longo, F.; Loparco, F.; Lott, B.; Lovellette, M. N.; Lubrano, P.; Madejski, G. M.; Makeev, A.; Mazziotta, M. N.; McEnery, J. E.; Meurer, C.; Michelson, P. F.; Mitthumsiri, W.; Mizuno, T.; Moiseev, A. A.; Monte, C.; Monzani, M. E.; Moretti, E.; Morselli, A.; Moskalenko, I. V.; Murgia, S.; Nolan, P. L.; Norris, J. P.; Nuss, E.; Ohsugi, T.; Omodei, N.; Orlando, E.; Ormes, J. F.; Paneque, D.; Panetta, J. H.; Parent, D.; Pelassa, V.; Pepe, M.; Pesce-Rollins, M.; Piron, F.; Porter, T. A.; Profumo, S.; Raino, S.; Rando, R.; Razzano, M.; Reimer, A.; Reimer, O.; Reposeur, T.; Ritz, S.; Rodriguez, A. Y.; Roth, M.; Sadrozinski, H. F. -W.; Sander, A.; Parkinson, P. M. Saz; Scargle, J. D.; Schalk, T. L.; Sellerholm, A.; Sgro, C.; Siskind, E. J.; Smith, D. A.; Smith, P. D.; Spandre, G.; Spinelli, P.; Strickman, M. S.; Suson, D. J.; Takahashi, H.; Takahashi, T.; Tanaka, T.; Thayer, J. B.; Thayer, J. G.; Thompson, D. J.; Tibaldo, L.; Torres, D. F.; Tramacere, A.; Uchiyama, Y.; Usher, T. L.; Vasileiou, V.; Vilchez, N.; Vitale, V.; Waite, A. P.; Wang, P.; Winer, B. L.; Wood, K. S.; Ylinen, T.; Ziegler, M.; Bullock, James S.; Kaplinghat, Manoj; Martinez, Gregory D.
Comments: 25 pages, 4 figures, accepted to ApJ, Corresponding authors: J. Cohen-Tanugi, C. Farnier, T.E. Jeltema, E. Nuss, and S. Profumo
Submitted: 2010-01-25
We report on the observations of 14 dwarf spheroidal galaxies with the Fermi Gamma-Ray Space Telescope taken during the first 11 months of survey mode operations. The Fermi telescope provides a new opportunity to test particle dark matter models through the expected gamma-ray emission produced by pair annihilation of weakly interacting massive particles (WIMPs). Local Group dwarf spheroidal galaxies, the largest galactic substructures predicted by the cold dark matter scenario, are attractive targets for such indirect searches for dark matter because they are nearby and among the most extreme dark matter dominated environments. No significant gamma-ray emission was detected above 100 MeV from the candidate dwarf galaxies. We determine upper limits to the gamma-ray flux assuming both power-law spectra and representative spectra from WIMP annihilation. The resulting integral flux above 100 MeV is constrained to be at a level below around 10^-9 photons cm^-2 s^-1. Using recent stellar kinematic data, the gamma-ray flux limits are combined with improved determinations of the dark matter density profile in 8 of the 14 candidate dwarfs to place limits on the pair annihilation cross-section of WIMPs in several widely studied extensions of the standard model. With the present data, we are able to rule out large parts of the parameter space where the thermal relic density is below the observed cosmological dark matter density and WIMPs (neutralinos here) are dominantly produced non-thermally, e.g. in models where supersymmetry breaking occurs via anomaly mediation. The gamma-ray limits presented here also constrain some WIMP models proposed to explain the Fermi and PAMELA e^+e^- data, including low-mass wino-like neutralinos and models with TeV masses pair-annihilating into muon-antimuon pairs. (Abridged)
[18]  oai:arXiv.org:0912.2040  [pdf] - 902699
The Spectral Energy Distribution of Fermi bright blazars
Abdo, A. A.; Ackermann, M.; Ajello, M.; Axelsson, M.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Baughman, B. M.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Blandford, R. D.; Bloom, E. D.; Bonamente, E.; Borgland, A.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Burnett, T. H.; Buson, S.; Caliandro, G. A.; Cameron, R. A.; Caraveo, P. A.; Casandjian, J. M.; Cavazzuti, E.; Cecchi, C.; Celik, O.; Charles, E.; Chaty, S.; Chekhtman, A.; Chiang, J.; Ciprini, S.; Claus, R.; Cohen-Tanugi, J.; Colafrancesco, S.; Cominsky, L. R.; Conrad, J.; Costamante, L.; Cutini, S.; Dermer, C. D.; de Angelis, A.; de Palma, F.; Digel, S. W.; Silva, E. do Couto e; Drell, P. S.; Dubois, R.; Dumora, D.; Farnier, C.; Favuzzi, C.; Fegan, S. J.; Focke, W. B.; Fortin, P.; Frailis, M.; Fuhrmann, L.; Fukazawa, Y.; Funk, S.; Fusco, P.; Gargano, F.; Gasparrini, D.; Gehrels, N.; Germani, S.; Giebels, B.; Giglietto, N.; Giommi, P.; Giordano, F.; Glanzman, T.; Godfrey, G.; Grenier, I. A.; Grove, J. E.; Guillemot, L.; Guiriec, S.; Hadasch, D.; Hanabata, Y.; Harding, A. K.; Hayashida, M.; Hays, E.; Healey, S. E.; Horan, D.; Hughes, R. E.; Itoh, R.; Jackson, M. S.; Johannesson, G.; Johnson, A. S.; Johnson, W. N.; Kadler, M.; Kamae, T.; Katagiri, H.; Kataoka, J.; Kawai, N.; Kerr, M.; Knodlseder, J.; Kocian, M. L.; Kuss, M.; Lande, J.; Latronico, L.; Longo, F.; Loparco, F.; Lott, B.; Lovellette, M. N.; Lubrano, P.; Madejski, G. M.; Makeev, A.; Max-Moerbeck, W.; Mazziotta, M. N.; McConville, W.; McEnery, J. E.; Meurer, C.; Michelson, P. F.
Comments: 85 pages, 38 figures, submitted to ApJ
Submitted: 2009-12-10
(Abridged) We have conducted a detailed investigation of the broad-band spectral properties of the \gamma-ray selected blazars of the Fermi LAT Bright AGN Sample (LBAS). By combining our accurately estimated Fermi gamma-ray spectra with Swift, radio, infra-red, optical and other hard X-ray/gamma-ray data, collected within three months of the LBAS data taking period, we were able to assemble high-quality and quasi-simultaneous Spectral Energy Distributions (SED) for 48 LBAS blazars.The SED of these gamma-ray sources is similar to that of blazars discovered at other wavelengths, clearly showing, in the usual Log $\nu $ - Log $\nu$ F$_\nu$ representation, the typical broad-band spectral signatures normally attributed to a combination of low-energy synchrotron radiation followed by inverse Compton emission of one or more components. We have used these SEDs to characterize the peak intensity of both the low and the high-energy components. The results have been used to derive empirical relationships that estimate the position of the two peaks from the broad-band colors (i.e. the radio to optical and optical to X-ray spectral slopes) and from the gamma-ray spectral index. Our data show that the synchrotron peak frequency $\nu_p^S$ is positioned between 10$^{12.5}$ and 10$^{14.5}$ Hz in broad-lined FSRQs and between $10^{13}$ and $10^{17}$ Hz in featureless BL Lacertae objects.We find that the gamma-ray spectral slope is strongly correlated with the synchrotron peak energy and with the X-ray spectral index, as expected at first order in synchrotron - inverse Compton scenarios. However, simple homogeneous, one-zone, Synchrotron Self Compton (SSC) models cannot explain most of our SEDs, especially in the case of FSRQs and low energy peaked (LBL) BL Lacs. (...)
[19]  oai:arXiv.org:0911.5698  [pdf] - 902584
X-ray polarimetry in Astrophysics with the Gas Pixel Detector
Comments: Proceeding of MPGD2009 Conference, June 12-15, 2009 Kolympari, Crete, Greece; 10 pages, 6 figures and 1 table
Submitted: 2009-11-30
The Gas Pixel Detector, recently developed and continuously improved by Pisa INFN in collaboration with IASF-Roma of INAF, can visualize the tracks produced within a low Z gas by photoelectrons of few keV. By reconstructing the impact point and the original direction of the photoelectrons, the GPD can measure the linear polarization of X-rays, while preserving the information on the absorption point, the energy and the time of individual photons. Applied to X-ray Astrophysics, in the focus of grazing incidence telescopes, it can perform angular resolved polarimetry with a huge improvement of sensitivity, when compared with the conventional techniques of Bragg diffraction at 45 degrees and Compton scattering around 90 degrees. This configuration is the basis of POLARIX and HXMT, two pathfinder missions, and is included in the baseline design of IXO, the very large X-ray telescope under study by NASA, ESA and JAXA.
[20]  oai:arXiv.org:0911.5099  [pdf] - 31065
Angular Resolution of a Photoelectric Polarimeter in the Focus of an Optical System
Comments: Proceedings of "The coming of age of x-ray polarimetry" Conference, Rome, April 27th-30th, 2009
Submitted: 2009-11-26
The INFN and INAF Italian research institutes developed a space-borne X-Ray polarimetry experiment based on a X-Ray telescope, focussing the radiation on a Gas Pixel Detector (GPD). The instrument obtains the polarization angle of the absorbed photons from the direction of emission of the photoelectrons as visualized in the GPD. Here we will show how we compute the angular resolution of such an instrument.
[21]  oai:arXiv.org:0810.2700  [pdf] - 17470
XPOL: a photoelectric polarimeter onboard XEUS
Comments: 10 pages, 6 figures
Submitted: 2008-10-15
The XEUS mission incorporates two satellites: the Mirror Spacecraft with 5 m2 of collecting area at 1 keV and 2 m2 at 7 keV, and an imaging resolution of 5" HEW and the Payload Spacecraft which carries the focal plane instrumentation. XEUS was submitted to ESA Cosmic Vision and was selected for an advanced study as a large mission. The baseline design includes XPOL, a polarimeter based on the photoelectric effect, that takes advantage of the large effective area which permits the study of the faint sources and of the long focal length, resulting in a very good spatial resolution, which allows the study of spatial features in extended sources. We show how, with XEUS, Polarimetry becomes an efficient tool at disposition of the Astronomical community.
[22]  oai:arXiv.org:0810.2708  [pdf] - 17472
X-ray polarimetry on-board HXMT
Comments: 10 pages, 7 figures
Submitted: 2008-10-15
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fraction of the HXMT time will be spent on dedicated pointing of particular sources, it could host, with moderate additional resources a pair of X-ray telescopes, each with a photoelectric X-ray polarimeter (EXP2, Efficient X-ray Photoelectric Polarimeter) in the focal plane. We present the design of the telescopes and the focal plane instrumentation and discuss the performance of this instrument to detect the degree and angle of linear polarization of some representative sources. Notwithstanding the limited resources, the proposed instrument can represent a breakthrough in X-ray Polarimetry.
[23]  oai:arXiv.org:0810.2684  [pdf] - 17465
A versatile facility for the calibration of X-ray polarimeters with polarized and unpolarized controlled beams
Comments: 12 pages, 11 figures
Submitted: 2008-10-15
We devised and built a versatile facility for the calibration of the next generation X-ray polarimeters with unpolarized and polarized radiation. The former is produced at 5.9 keV by means of a Fe55 radioactive source or by X-ray tubes, while the latter is obtained by Bragg diffraction at nearly 45 degrees. Crystals tuned with the emission lines of X-ray tubes with molybdenum, rhodium, calcium and titanium anodes are employed for the efficient production of highly polarized photons at 2.29, 2.69, 3.69 and 4.51 keV respectively. Moreover the continuum emission is exploited for the production of polarized photons at 1.65 keV and 2.04 keV and at energies corresponding to the higher orders of diffraction. The photons are collimated by means of interchangeable capillary plates and diaphragms, allowing a trade-off between collimation and high fluxes. The direction of the beam is accurately arranged by means of high precision motorized stages, controlled via computer so that long and automatic measurements can be done. Selecting the direction of polarization and the incidence point we can map the response of imaging devices to both polarized and unpolarized radiation. Changing the inclination of the beam we can study the systematic effects due to the focusing of grazing incidence optics and the feasibility of instruments with large field of view.
[24]  oai:arXiv.org:0810.2693  [pdf] - 17468
The Gas Pixel Detector as an X-ray photoelectric polarimeter with a large field of view
Comments: 11 pages, 8 figures
Submitted: 2008-10-15
The Gas Pixel Detector (GPD) is a new generation device which, thanks to its 50 um pixels, is capable of imaging the photoelectrons tracks produced by photoelectric absorption in a gas. Since the direction of emission of the photoelectrons is strongly correlated with the direction of polarization of the absorbed photons, this device has been proposed as a polarimeter for the study of astrophysical sources, with a sensitivity far higher than the instruments flown to date. The GPD has been always regarded as a focal plane instrument and then it has been proposed to be included on the next generation space-borne missions together with a grazing incidence optics. Instead in this paper we explore the feasibility of a new kind of application of the GPD and of the photoelectric polarimeters in general, i.e. an instrument with a large field of view. By means of an analytical treatment and measurements, we verify if it is possible to preserve the sensitivity to the polarization for inclined beams, opening the way for the measurement of X-ray polarization for transient astrophysical sources. While severe systematic effects arise for inclination greater than about 20 degrees, methods and algorithms to control them are discussed.
[25]  oai:arXiv.org:0709.4623  [pdf] - 5478
Low energy polarization sensitivity of the Gas Pixel Detector
Comments: 15 pages, 12 figures. Accepted for publication in NIMA
Submitted: 2007-09-28
An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been proposed to be included in many upcoming space missions to fill the gap of about 30 years from the first (and to date only) positive measurement of polarized X-ray emission from an astrophysical source. The estimated sensitivity of the current prototype peaks at an energy of about 3 keV, but the lack of readily available polarized sources in this energy range has prevented the measurement of detector polarimetric performances. In this paper we present the measurement of the Gas Pixel Detector polarimetric sensitivity at energies of a few keV and the new, light, compact and transportable polarized source that was devised and built to this aim. Polarized photons are produced, from unpolarized radiation generated with an X-ray tube, by means of Bragg diffraction at nearly 45 degrees. The employment of mosaic graphite and flat aluminum crystals allow the production of nearly completely polarized photons at 2.6, 3.7 and 5.2 keV from the diffraction of unpolarized continuum or line emission. The measured modulation factor of the Gas Pixel Detector at these energies is in good agreement with the estimates derived from a Monte Carlo software, which was up to now employed for driving the development of the instrument and for estimating its low energy sensitivity. In this paper we present the excellent polarimetric performance of the Gas Pixel Detector at energies where the peak sensitivity is expected. These measurements not only support our previous claims of high sensitivity but confirm the feasibility of astrophysical X-ray photoelectric polarimetry.
[26]  oai:arXiv.org:0709.3978  [pdf] - 5330
A very compact polarizer for an X-ray polarimeter calibration
Comments: 12 pages, 22 figures
Submitted: 2007-09-25
We devised and built a light, compact and transportable X-ray polarized source based on the Bragg diffraction at nearly 45 degrees. The source is composed by a crystal coupled to a small power X-ray tube. The angles of incidence are selected by means of two orthogonal capillary plates which, due to the small diameter holes (10 um) allow good collimation with limited sizes. All the orders of diffraction defined by the crystal lattice spacing are polarized up to the maximum order limited by the X-ray tube voltage. Selecting suitably the crystal and the X-ray tube, either the line or the continuum emission can be diffracted, producing polarized photons at different energies. A very high degree of polarization and reasonable fluxes can be reached with a suitable choice of the capillary plates collimation. We present the source and test its performances with the production of nearly completely polarized radiation at 2.6, 5.2, 3.7 and 7.4 keV thanks to the employment of graphite and aluminum crystals, with copper and calcium X-ray tubes respectively. Triggered by the very compact design of the source, we also present a feasibility study for an on-board polarized source, coupled to a radioactive Fe55 nuclide and a PVC thin film, for the calibration of the next generation space-borne X-ray polarimeters at 2.6 and 5.9 keV.
[27]  oai:arXiv.org:0709.3992  [pdf] - 5336
An X-ray Polarimeter for HXMT Mission
Comments: 10 pages, 9 figures
Submitted: 2007-09-25
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fraction of the HXMT time will be spent on dedicated pointing of particular sources, it could host, with moderate additional resources a pair of X-ray telescopes, each with a photoelectric X-ray polarimeter in the focal plane. We present the design of the telescopes and the focal plane instrumentation and discuss the performance of this instrument to detect the degree and angle of linear polarization of some representative sources. Notwithstanding the limited resources the proposed instrument can represent a breakthrough in X-ray Polarimetry.
[28]  oai:arXiv.org:physics/0703176  [pdf] - 119212
Imaging with the invisible light
Comments: 6 pages, 14 figures, presented at the 11th Vienna Conference on Instrumentation VIC 2007, submitted to Nuclear Instruments and Methods A
Submitted: 2007-03-19, last modified: 2007-03-20
We describe a UV photo-detector with single photon(electron) counting and imaging capability. It is based on a CsI photocathode, a GEM charge multiplier and a self triggering CMOS analog pixel chip with 105k pixels at 50 micron pitch. The single photoelectron produced by the absorption of a UV photon is drifted to and multiplied inside a single GEM hole. The coordinates of the GEM avalanche are reconstructed with high accuracy (4 micron rms) by the pixel chip. As a result the map of the GEM holes, arranged on a triangular pattern at 50micron pitch, is finely imaged.
[29]  oai:arXiv.org:astro-ph/0611512  [pdf] - 86898
A Sealed Gas Pixel Detector for X-ray Astronomy
Comments: 10 pages, 10 figures, Presented to the Sixth International "Hiroshima" Symposium on the Development and Application of Semiconductor Tracking Detectors (to be published on NIMA)
Submitted: 2006-11-16, last modified: 2006-11-20
We report on the results of a new, sealed, Gas Pixel Detector. The very compact design and the absence of the gas flow system, make this detector substantially ready for use as focal plane detector for future X-ray space telescopes. The instrument brings high sensitivity to X-ray polarimetry, which is the last unexplored field of X-ray astronomy. It derives the polarization information from the track of the photoelectrons that are imaged by a high gain (>1000), fine pitch GEM that matches the pitch of a pixel ASIC which is the collecting anode of the GPD (105k, 50 micron wide, hexagonal cells). The device is able to simultaneously perform good imaging (50-60 micron), moderate spectroscopy (~15% at 6 keV) as well as fast, high rate timing in the 1-10keV range. Moreover, being truly 2D, it is non dispersive and does not require any rotation. The great improvement of sensitivity, at least two orders of magnitude with respect to traditional polarimeters (based on Bragg crystals or Thomson scattering), will allow the direct exploration of the most dramatic objects of the X-ray sky. At the focus of the large mirror area of the XEUS telescope it will be decisive in reaching many of the scientific goals of the mission. With integration times of the order of one day, polarimetry of Active Galactic Nuclei at the per cent level will be possible, making for a real breakthrough in high energy astrophysics.
[30]  oai:arXiv.org:astro-ph/0609576  [pdf] - 85168
POLARIX: a small mission of x-ray polarimetry
Comments: 9 pages, 5 figures
Submitted: 2006-09-20
X-Ray Polarimetry can be now performed by using a Micro Pattern Gas Chamber in the focus of a telescope. It requires large area optics for most important scientific targets. But since the technique is additive a dedicated mission with a cluster of small telescopes can perform many important measurements and bridge the 40 year gap between OSO-8 data and future big telescopes such as XEUS. POLARIX has been conceived as such a pathfinder. It is a Small Satellite based on the optics of JET-X. Two telescopes are available in flight configuration and three more can be easily produced starting from the available superpolished mandrels. We show the capabilities of such a cluster of telescopes each equipped with a focal plane photoelectric polarimeter and discuss a few alternative solutions.
[31]  oai:arXiv.org:astro-ph/0609573  [pdf] - 85165
An X-ray polarimeter for hard X-ray optics
Comments: 12 pages, 7 figures
Submitted: 2006-09-20
Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We calculated the sensitivity with Neon and Argon based mixtures at high pressure with thick absorption gap: placing the MPGC at focus of a next generation multi-layer optics, galatic and extragalactic X-ray polarimetry can be done up till 30 keV.
[32]  oai:arXiv.org:astro-ph/0609571  [pdf] - 85163
A photoelectric polarimeter for XEUS: a new window in x-ray sky
Comments: 12 pages, 7 figures
Submitted: 2006-09-20
XEUS is a large area telescope aiming to rise X-ray Astronomy to the level of Optical Astronomy in terms of collecting areas. It will be based on two satellites, locked on a formation flight, one with the optics, one with the focal plane. The present design of the focal plane foresees, as an auxiliary instrument, the inclusion of a Polarimeter based on a Micropattern Chamber. We show how such a device is capable to solve open problems on many classes of High Energy Astrophysics objects and to use X-ray sources as a laboratory for a substantial progress on Fundamental Physics.
[33]  oai:arXiv.org:physics/0604114  [pdf] - 119160
Direct reading of charge multipliers with a self-triggering CMOS analog chip with 105k pixels at 50 micron pitch
Comments: 14 pages, 18 figures, to be submitted to Nuclear Instruments and methode A
Submitted: 2006-04-14, last modified: 2006-04-26
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which represents a big step forward both in terms of size and performance, is the last version of three generations of custom ASICs of increasing complexity. The CMOS pixel array has the top metal layer patterned in a matrix of 105600 hexagonal pixels at 50 micron pitch. Each pixel is directly connected to the underneath full electronics chain which has been realized in the remaining five metal and two poly-silicon layers of a 0.18 micron VLSI technology. The chip has customizable self-triggering capability and includes a signal pre-processing function for the automatic localization of the event coordinates. In this way it is possible to reduce significantly the readout time and the data volume by limiting the signal output only to those pixels belonging to the region of interest. The very small pixel area and the use of a deep sub-micron CMOS technology has brought the noise down to 50 electrons ENC. Results from in depth tests of this device when coupled to a fine pitch (50 micron on a triangular pattern) Gas Electron Multiplier are presented. The matching of readout and gas amplification pitch allows to get optimal results. The application of this detector for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation when working with two gas mixtures and two different photon energies is shown. Results from a full MonteCarlo simulation for several galactic and extragalactic atronomical sources are also reported.
[34]  oai:arXiv.org:astro-ph/0603399  [pdf] - 80608
Opening a New Window to Fundamental Physics and Astrophysics: X-ray Polarimetry
Comments: 8 pages 1 table 14 figures
Submitted: 2006-03-15
An extensive theoretical literature predicts that X-ray Polarimetry can directly determine relevant physical and geometrical parameters of astrophysical sources, and discriminate between models further than allowed by spectral and timing data only. X-ray Polarimetry can also provide tests of Fundamental Physics. A high sensitivity polarimeter in the focal plane of a New Generation X-ray telescope could open this new window in the High Energy Sky.
[35]  oai:arXiv.org:astro-ph/0512242  [pdf] - 78442
Gas Pixel Detectors for X-ray Polarimetry applications
Comments: 16 pages, 20 figures, accepted for publication in Nuclear Instruments and Methods in Physics Research Section A
Submitted: 2005-12-09, last modified: 2006-02-08
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated Circuit (ASIC) built in deep sub-micron technology has been developed to realize a monolithic device that is, at the same time, the pixelized charge collecting electrode and the amplifying, shaping and charge measuring front-end electronics. The CMOS chip has the top metal layer patterned in a matrix of 80 micron pitch hexagonal pixels, each of them directly connected to the underneath electronics chain which has been realized in the remaining five layers of the 0.35 micron VLSI technology. Results from tests of a first prototype of such detector with 2k pixels and a full scale version with 22k pixels are presented. The application of this device for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation is shown. Results from a full MonteCarlo simulation for two astronomical sources, the Crab Nebula and the Hercules X1, are also reported.
[36]  oai:arXiv.org:physics/0403019  [pdf] - 1238072
Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode
Comments: 11 pages, 14 figures, presented at the Xth Vienna Conference on Instrumentation (Vienna, February 16-21 2004). For a higher resolution paper contact gloria.spandre@pi.infn.it
Submitted: 2004-03-01
In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the individual pixel to the external electronics chain. For this reason a custom CMOS array of 2101 active pixels with 80 micron pitch, directly used as the charge collecting anode of a GEM amplifying structure, has been developed and built. Each charge collecting pad, hexagonally shaped, realized using the top metal layer of a deep submicron VLSI technology is individually connected to a full electronics chain (pre-amplifier, shaping-amplifier, sample and hold, multiplexer) which is built immediately below it by using the remaining five active layers. The GEM and the drift electrode window are assembled directly over the chip so the ASIC itself becomes the pixelized anode of a MicroPattern Gas Detector. With this approach, for the first time, gas detectors have reached the level of integration and resolution typical of solid state pixel detectors. Results from the first tests of this new read-out concept are presented. An Astronomical X-Ray Polarimetry application is also discussed.
[37]  oai:arXiv.org:astro-ph/0207440  [pdf] - 50583
X-ray Astronomical Polarimetry in the XEUS Era
Comments: 6 pages, 7 pdf figures, Proceedindg of the Workshop: "XEUS - studying the evolution of the hot universe" held in Garching, March 11-13, 2002, eds. G. Hasinger, Th. Boller and A. Parmar, MPE report
Submitted: 2002-07-20
X-ray Polarimetry is almost as old as X-ray Astronomy. Since the first discovery of X-ray sources theoretical analysis suggested that a high degree of linear polarization could be expected due either to the, extremely non thermal, emission mechanism or to the transfer of radiation in highly asymmetric systems. The actual implementation of this subtopic was, conversely, relatively deceiving. This is mainly due to the limitation of the conventional techniques based on the Bragg diffraction at 45deg, or on Thomson scattering around 90deg. Acually no X-ray Polarimeter has been launched since 25 years. Nevertheless the expectations from such measurement on several astrophysical targets including High and Low Mass X-Ray Binaries, isolated neutron Stars, Galactic and Extragalactic Black Holes is extremely attractive. We developed a new technique to measure the linear polarization of X-ray sources. It is based on the visualization of photoelectron tracks in a, finely subdivided, gas filled detector (micropattern). The initial direction of the photoelectron is derived and from the angular distribution of the tracks the amount and angle of polarization is computed. This technique can find an optimal exploitation in the focus of XEUS-1. Even in a very conservative configuration (basically the already existing prototype) the photoelectric polarimeter could perform polarimetry at % level on many AGNs. Further significant improvements can be expected from a technological development on the detector and with the use of XEUS-2 telescope.
[38]  oai:arXiv.org:astro-ph/0107486  [pdf] - 43857
An efficient photoelectric X-ray Polarimeter for the study of Black Holes and Neutron Stars
Comments: 17 pages, 3 figures, 1 table
Submitted: 2001-07-25
In astronomy there are basically four kinds of observations to extract the information carried by electromagnetic radiation: photometry, imaging, spectroscopy and polarimetry. By optimal exploitation of the first three techniques, X-ray astronomy has been able to unveil the violent world of compact high energy sources. Here we report on a new instrument that brings high efficiency also to X-ray polarimetry, the last unexplored field of X-ray astronomy. It will then be possible to resolve the internal structures of compact sources which otherwise would remain inaccessible, even to X-ray interferometry1. Polarimetry could provide a direct, visual picture of the state of matter under extreme magnetic and gravitational fields by measuring the radiation polarized through interaction with the highly asymmetric matter distribution (accretion disk) and with the magnetic field. The new instrument derives the polarization information from the track of the photoelectrons imaged by a finely subdivided gas detector. Its great improvement of sensitivity (at least two orders of magnitude) will allow direct exploration of the most dramatic objects of the X-ray sky.
[39]  oai:arXiv.org:astro-ph/0012183  [pdf] - 39772
Astronomical x-ray polarimetry based on photoelectric effect with microgap detectors
Comments: 45 pages included 13 figures; (Accepted for publication in : Nuclear Instruments and Methods in Physics Research A)
Submitted: 2000-12-08
The polarisation of x-ray photons can be determined by measuring the direction of emission of a K-shell photoelectron. Effective exploitation of this effect below 10 keV would allow development of a highly sensitive x-ray polarimeter dedicated in particular to x-ray astronomy observations. Only with the advent of finely segmented gas detectors was it possible to detect polarisation sensitivity based on the photoelectric effect in this energy range. Simulation and measurements at 5.4 and 8.04 keV with a microgap gas counter, using both a polarised and an unpolarised x-ray source, showed that the photoelectron track in a neon-based gas mixture retains the memory of the polarisation of the incoming photons. Possible experiments aimed at galactic/extragalactic sources and solar flares are considered and their sensitivity to these sources is calculated.