Normalized to: Breskin, A.
[1]
oai:arXiv.org:2006.03114 [pdf] - 2109247
Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering
Aalbers, J.;
Agostini, F.;
Maouloud, S. E. M. Ahmed;
Alfonsi, M.;
Althueser, L.;
Amaro, F.;
Angevaare, J.;
Antochi, V. C.;
Antunovic, B.;
Aprile, E.;
Arazi, L.;
Arneodo, F.;
Balzer, M.;
Baudis, L.;
Baur, D.;
Benabderrahmane, M. L.;
Biondi, Y.;
Bismark, A.;
Bourgeois, C.;
Breskin, A.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruno, G.;
Brünner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J.;
Cichon, D.;
Clark, M.;
Colijn, A. P.;
Conrad, J.;
Cuenca-García, J. J.;
Cussonneau, J. P.;
Decowski, M. P.;
Depoian, A.;
Dierle, J.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Douillet, D.;
Drexlin, G.;
Eitel, K.;
Engel, R.;
Erdal, E.;
Ferella, A. D.;
Fischer, H.;
Fischer, P.;
Fulgione, W.;
Gaemers, P.;
Galloway, M.;
Gao, F.;
Giovagnoli, D.;
Girard, F.;
Glade-Beucke, R.;
Glück, F.;
Grandi, L.;
Grohmann, S.;
Größle, R.;
Gumbsheimer, R.;
Hannen, V.;
Hansmann-Menzemer, S.;
Hils, C.;
Holzapfel, B.;
Howlett, J.;
Iaquaniello, G.;
Jörg, F.;
Keller, M.;
Kellerer, J.;
Khundzakishvili, G.;
Kilminster, B.;
Kleifges, M.;
Kleiner, T. K.;
Koltmann, G.;
Kopec, A.;
Kopmann, A.;
Krauss, L. M.;
Kuger, F.;
LaCascio, L.;
Landsman, H.;
Lang, R. F.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Villalpando, A. Loya;
Ma, Y.;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Masson, E.;
McFadden, N.;
Meinhardt, P.;
Meyer, R.;
Milosevic, B.;
Milutinovic, S.;
Molinario, A.;
Monteiro, C. M. B.;
Morå, K.;
Morteau, E.;
Mosbacher, Y.;
Murra, M.;
Newstead, J. L.;
Ni, K.;
Oberlack, U. G.;
Obradovic, M.;
Odgers, K.;
Ostrovskiy, I.;
Palacio, J.;
Pandurovic, M.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pierre, M.;
Pizzella, V.;
Plante, G.;
Qi, J.;
Qin, J.;
García, D. Ramírez;
Reichard, S. E.;
Rupp, N.;
Sanchez-Lucas, P.;
Santos, J.;
Sartorelli, G.;
Schulte, D.;
Schultz-Coulon, H. -C.;
Eißing, H. Schulze;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Sharma, S.;
Shen, W.;
Silva, M.;
Simgen, H.;
Steidl, M.;
Stern, S.;
Subotic, D.;
Szabo, P.;
Terliuk, A.;
Therreau, C.;
Thers, D.;
Thieme, K.;
Toennies, F.;
Trotta, R.;
Tunnell, C. D.;
Valerius, K.;
Volta, G.;
Vorkapic, D.;
Weber, M.;
Wei, Y.;
Weinheimer, C.;
Weiss, M.;
Wenz, D.;
Wittweg, C.;
Wolf, J.;
Wuestling, S.;
Wurm, M.;
Xing, Y.;
Zhu, T.;
Zhu, Y.;
Zopounidis, J. P.;
Zuber, K.
Submitted: 2020-06-04
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to
solar neutrinos via elastic electron scattering. We find that DARWIN will have
the potential to measure the fluxes of five solar neutrino components: $pp$,
$^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O
and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and,
thus, would benefit from a depleted target. A high-statistics observation of
$pp$ neutrinos would allow us to infer the values of the weak mixing angle,
$\sin^2\theta_w$, and the electron-type neutrino survival probability, $P_e$,
in the electron recoil energy region from a few keV up to 200 keV for the first
time, with relative precision of 5% and 4%, respectively, at an exposure of 300
ty. An observation of $pp$ and $^7$Be neutrinos would constrain the
neutrino-inferred solar luminosity down to 0.2%. A combination of all flux
measurements would distinguish between the high (GS98) and low metallicity
(AGS09) solar models with 2.1-2.5$\sigma$ significance, independent of external
measurements from other experiments or a measurement of $^8$B neutrinos through
coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate
that with a depleted target DARWIN may be sensitive to the neutrino capture
process of $^{131}$Xe.
[2]
oai:arXiv.org:1708.07051 [pdf] - 1697916
The XENON1T Dark Matter Experiment
XENON Collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Antunes, B.;
Arneodo, F.;
Balata, M.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breskin, A.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Chiarini, A.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Corrieri, R.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Disdier, J. -M.;
Doets, M.;
Duchovni, E.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Florin, D.;
Front, D.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grandi, L.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Huhmann, C.;
Itay, R.;
James, A.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Maier, R.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orlandi, D.;
Othegraven, R.;
Pakarha, P.;
Parlati, S.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
García, D. Ramírez;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Saldahna, R.;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stern, M.;
Stein, A.;
Tatananni, D.;
Tatananni, L.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Walet, R.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.
Submitted: 2017-08-23
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is
the first WIMP dark matter detector operating with a liquid xenon target mass
above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute
the active target of the dual-phase time projection chamber. The scintillation
and ionization signals from particle interactions are detected with
low-background photomultipliers. This article describes the XENON1T instrument
and its subsystems as well as strategies to achieve an unprecedented low
background level. First results on the detector response and the performance of
the subsystems are also presented.
[3]
oai:arXiv.org:1606.07001 [pdf] - 1525702
DARWIN: towards the ultimate dark matter detector
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Amsler, C.;
Aprile, E.;
Arazi, L.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Benabderrahmane, M. L.;
Berger, T.;
Beskers, B.;
Breskin, A.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Buetikofer, L.;
Calven, J.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
Diglio, S.;
Drexlin, G.;
Duchovni, E.;
Erdal, E.;
Eurin, G.;
Ferella, A.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Di Gangi, P.;
Di Giovanni, A.;
Galloway, M.;
Garbini, M.;
Geis, C.;
Glueck, F.;
Grandi, L.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hannen, V.;
Hogenbirk, E.;
Howlett, J.;
Hilk, D.;
Hils, C.;
James, A.;
Kaminsky, B.;
Kazama, S.;
Kilminster, B.;
Kish, A.;
Krauss, L. M.;
Landsman, H.;
Lang, R. F.;
Lin, Q.;
Linde, F. L.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Mora, K. D.;
Morteau, E.;
Murra, M.;
Naganoma, J.;
Newstead, J. L.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
de Perio, P.;
Persiani, R.;
Piastra, F.;
Piro, M. C.;
Plante, G.;
Rauch, L.;
Reichard, S.;
Rizzo, A.;
Rupp, N.;
Santos, J. M. F. Dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schumann, M.;
Schreiner, J.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Silva, M. C.;
Simgen, H.;
Sissol, P.;
von Sivers, M.;
Thers, D.;
Thurn, J.;
Tiseni, A.;
Trotta, R.;
Tunnell, C. D.;
Valerius, K.;
Vargas, M. A.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Wester, T.;
Wulf, J.;
Zhang, Y.;
Zhu, T.;
Zuber, K.
Submitted: 2016-06-22
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for
the direct detection of dark matter using a multi-ton liquid xenon time
projection chamber at its core. Its primary goal will be to explore the
experimentally accessible parameter space for Weakly Interacting Massive
Particles (WIMPs) in a wide mass-range, until neutrino interactions with the
target become an irreducible background. The prompt scintillation light and the
charge signals induced by particle interactions in the xenon will be observed
by VUV sensitive, ultra-low background photosensors. Besides its excellent
sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large
mass, low-energy threshold and ultra-low background level will also be
sensitive to other rare interactions. It will search for solar axions, galactic
axion-like particles and the neutrinoless double-beta decay of 136-Xe, as well
as measure the low-energy solar neutrino flux with <1% precision, observe
coherent neutrino-nucleus interactions, and detect galactic supernovae. We
present the concept of the DARWIN detector and discuss its physics reach, the
main sources of backgrounds and the ongoing detector design and R&D efforts.
[4]
oai:arXiv.org:1512.07501 [pdf] - 1395004
Physics reach of the XENON1T dark matter experiment
The XENON collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arazi, L.;
Arneodo, F.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Berger, T.;
Breur, P.;
Breskin, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fieguth, A.;
Franco, D.;
Fulgione, W.;
Galloway, M.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Hasterok, C.;
Itay, R.;
Kaether, F.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Calloch, M. Le;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Macmullin, S.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Mayani, D.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Micheneau, K.;
Miguez, B.;
Molinario, A.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
von Sivers, M.;
Wall, R.;
Wang, H.;
Weber, M.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Zhang, Y.
Submitted: 2015-12-23, last modified: 2016-04-15
The XENON1T experiment is currently in the commissioning phase at the
Laboratori Nazionali del Gran Sasso, Italy. In this article we study the
experiment's expected sensitivity to the spin-independent WIMP-nucleon
interaction cross section, based on Monte Carlo predictions of the electronic
and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and ($1$,
$12$) keV electronic recoil equivalent energy region, before applying any
selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm
0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the
decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil
background in the corresponding nuclear recoil equivalent energy region ($4$,
$50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from
radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from
coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$
from muon-induced neutrons.
The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio
method, after converting the deposited energy of electronic and nuclear recoils
into the scintillation and ionization signals seen in the detector. We take
into account the systematic uncertainties on the photon and electron emission
model, and on the estimation of the backgrounds, treated as nuisance
parameters. The main contribution comes from the relative scintillation
efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs
and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial
volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$
cm$^2$ at m$_\chi$=$50$ GeV/$c^2$.
[5]
oai:arXiv.org:1603.07669 [pdf] - 1542660
First demonstration of VUV-photon detection in liquid xenon with THGEM
and GEM-based Liquid Hole Multipliers
Submitted: 2016-03-24
The bubble-assisted Liquid Hole-Multiplier (LHM) is a recently-introduced
detection concept for noble-liquid time projection chambers. In this "local
dual-phase" detection element, a gas bubble is supported underneath a
perforated electrode (e.g., Thick Gas Electron Multiplier - THGEM, or Gas
Electron Multiplier - GEM). Electrons drifting through the holes induce large
electroluminescence signals as they pass into the bubble. In this work we
report on recent results of THGEM and GEM electrodes coated with cesium iodide
and immersed in liquid xenon, allowing - for the first time - the detection of
primary VUV scintillation photons in addition to ionization electrons using
LHMs.
[6]
oai:arXiv.org:1505.02316 [pdf] - 1284805
Liquid Hole Multipliers: bubble-assisted electroluminescence in liquid
xenon
Submitted: 2015-05-09, last modified: 2015-05-13
In this work we discuss the mechanism behind the large electroluminescence
signals observed at relatively low electric fields in the holes of a Thick Gas
Electron Multiplier (THGEM) electrode immersed in liquid xenon. We present
strong evidence that the scintillation light is generated in xenon bubbles
trapped below the THGEM holes. The process is shown to be remarkably stable
over months of operation, providing - under specific thermodynamic conditions -
energy resolution similar to that of present dual-phase liquid xenon
experiments. The observed mechanism may serve as the basis for the development
of Liquid Hole Multipliers (LHMs), capable of producing local charge-induced
electroluminescence signals in large-volume single-phase noble-liquid detectors
for dark matter and neutrino physics experiments.
[7]
oai:arXiv.org:1406.2374 [pdf] - 940307
Conceptual design and simulation of a water Cherenkov muon veto for the
XENON1T experiment
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Breskin, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Lyashenko, A.;
MacMullin, S.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Paras, D. Mayani;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Morana, G.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer., C.
Submitted: 2014-06-09, last modified: 2015-02-25
XENON is a dark matter direct detection project, consisting of a time
projection chamber (TPC) filled with liquid xenon as detection medium. The
construction of the next generation detector, XENON1T, is presently taking
place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a
sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~
\mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires
a background reduction by two orders of magnitude compared to XENON100, the
current generation detector. An active system that is able to tag muons and
muon-induced backgrounds is critical for this goal. A water Cherenkov detector
of $\sim$10 m height and diameter has been therefore developed, equipped with 8
inch photomultipliers and cladded by a reflective foil. We present the design
and optimization study for this detector, which has been carried out with a
series of Monte Carlo simulations. The muon veto will reach very high detection
efficiencies for muons ($>99.5%$) and showers of secondary particles from muon
interactions in the rock ($>70%$). Similar efficiencies will be obtained for
XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity
by another order of magnitude. With the Cherenkov water shield studied here,
the background from muon-induced neutrons in XENON1T is negligible.
[8]
oai:arXiv.org:1303.4326 [pdf] - 1165339
Unambiguous Identification of the Second 2+ State in 12C and the
Structure of the Hoyle State
Zimmerman, W. R.;
Ahmed, M. W.;
Bromberger, B.;
Stave, S. C.;
Breskin, A.;
Dangendorf, V.;
Delbar, Th.;
Gai, M.;
Henshaw, S. S.;
Mueller, J. M.;
Sun, C.;
Tittelmeier, K.;
Weller, H. R.;
Wu, Y. K.
Submitted: 2013-03-18
The second 2+ state of 12C, predicted over fifty years ago as an excitation
of the Hoyle state, has been unambiguously identified using the 12C(g,a_0)8Be
reaction. The alpha particles produced by the photodisintegration of 12C were
detected using an Optical Time Projection Chamber (O-TPC). Data were collected
at beam energies between 9.1 and 10.7 MeV using the intense nearly
mono-energetic gamma-ray beams at the HIgS facility. The measured angular
distributions determine the cross section and the E1-E2 relative phases as a
function of energy leading to an unambiguous identification of the second 2+
state in 12C at 10.03(11) MeV, with a total width of 800(130) keV and a ground
state gamma-decay width of 60(10) meV; B(E2: 2+ ---> gs) = 0.73(13) e2fm4 [or
0.45(8) W.u.]. The Hoyle state and its rotational 2+ state that are more
extended than the ground state of 12C presents a challenge and constraints for
models attempting to reveal the nature of three alpha particle states in 12C.
Specifically it challenges the ab-initio Lattice Effective Field Theory (L-EFT)
calculations that predict similar r.m.s. radii for the ground state and the
Hoyle state.
[9]
oai:arXiv.org:1101.1940 [pdf] - 288646
An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With
Gamma-Ray Beams at HIgS
Gai, M.;
Ahmed, M. W.;
Stave, S. C.;
Zimmerman, W. R.;
Breskin, A.;
Bromberger, B.;
Chechik, R.;
Dangendorf, V.;
Delbar, Th.;
France, R. H.;
Henshaw, S. S.;
Kading, T. J.;
Martel, P. P.;
McDonald, J. E. R.;
Seo, P. -N.;
Tittelmeier, K.;
Weller, H. R.;
Young, A. H.
Submitted: 2011-01-10
We report on the construction, tests, calibrations and commissioning of an
Optical Readout Time Projection Chamber (O-TPC) detector operating with a
CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure
the cross sections of several key nuclear reactions involved in stellar
evolution. In particular, a study of the rate of formation of oxygen and carbon
during the process of helium burning will be performed by exposing the chamber
gas to intense nearly mono-energetic gamma-ray beams at the High Intensity
Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of
30x30x21 cm^3. Ionization electrons drift towards a double parallel grid
avalanche multiplier, yielding charge multiplication and light emission.
Avalanche induced photons from N2 emission are collected, intensified and
recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional
track images. The event's time projection (third coordinate) and the deposited
energy are recorded by photomultipliers and by the TPC charge-signal,
respectively. A dedicated VME-based data acquisition system and associated data
analysis tools were developed to record and analyze these data. The O-TPC has
been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd
source placed within its volume with a measured energy resolution of 3.0%.
Tracks of alpha and 12C particles from the dissociation of 16O and of three
alpha-particles from the dissociation of 12C have been measured during initial
in-beam test experiments performed at the HIgS facility at Duke University. The
full detection system and its performance are described and the results of the
preliminary in-beam test experiments are reported.
[10]
oai:arXiv.org:0706.1106 [pdf] - 2001
Toward Application of a Thick Gas Electron Multiplier (THGEM) Readout
for a Dark Matter Detector
Submitted: 2007-06-07
The Yale-Weizmann collaboration aims to develop a low-radioactivity
(low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in
measurements to be performed deep underground as for example carried out by the
XENON collaboration. A major issue is the background induced by natural
radioactivity of present-detector components including the Photo Multiplier
Tubes (PMT) made from glass with large U-Th content. We propose to use advanced
Thick Gaseous Electron Multipliers (THGEM) recently developed at the Weizmann
Institute of Science (WIS). These "hole-multipliers" will measure in a
two-phase (liquid/gas) Xe detector electrons extracted into the gas phase from
both ionization in the liquid as well as scintillation-induced photoelectrons
from a CsI photocathode immersed in LXe. We report on initial tests (in gas) of
THGEM made out of Cirlex (Kapton) which is well known to have low Ra-Th content
instead of the usual G10 material with high Ra-Th content.
[11]
oai:arXiv.org:physics/0602188 [pdf] - 119148
Amplification and Scintillation Properties of Oxygen-Rich Gas Mixtures
for Optical-TPC Applications
Submitted: 2006-02-27, last modified: 2006-05-27
We studied electron amplification and light emission from avalanches in
oxygen-containing gas mixtures. The mixtures investigated in this work
included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2.
Double-Step Parallel Gap (DSPG) multipliers and THick Gas Electron Multipliers
(THGEM) were investigated. High light yields were measured from CO2+N2 and
CO2+TEA, though with different emission spectra. We observed the characteristic
wave-length emission of N2 and of TEA and used a polymer wave-length shifter to
convert TEA UV-light into the visible spectrum. The results of these
measurements indicate the applicability of optical recording of ionizing tracks
in a TPC target-detector designed to study the cross section of the 16O(g,a)12C
reaction, a central problem in nuclear astrophysics.
[12]
oai:arXiv.org:nucl-ex/0504003 [pdf] - 118469
Optical Readout Time Projection Chamber (O-TPC) for a Study of Oxygen
Formation In Stellar Helium Burning
Submitted: 2005-04-01
We are developing an Optical Readout Time Projection Chamber (O-TPC) detector
for the study of the 12C(a,g)16O reaction that determines the ratio of carbon
to oxygen in helium burning. This ratio is crucial for understanding the final
fate of a progenitor star and the nucleosynthesis of elements prior to a Type
II supernova; an oxygen rich star is predicted to collapse to a black hole, and
a carbon rich star to a neutron star. Type Ia supernovae (SNeIa) are used as
standard candles for measuring cosmological distances with the use of an
empirical light curve-luminosity stretching factor. It is essential to
understand helium burning that yields the carbon/oxygen white dwarf and thus
the initial stage of SNeIa. The O-TPC is intended for use with high intensity
photon beams extracted from the HIgS/TUNL facility at Duke University to study
the 16O(g,a)12C reaction, and thus the direct reaction at energies as low as
0.7 MeV. We are conducting a systematical study of the best oxygen containing
gas with light emitting admixture(s) for use in such an O-TPC. Preliminary
results with CO_2 + TEA mixture were obtained