sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Breskin, A.

Normalized to: Breskin, A.

12 article(s) in total. 320 co-authors, from 1 to 6 common article(s). Median position in authors list is 7,0.

[1]  oai:arXiv.org:2006.03114  [pdf] - 2109247
Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering
Aalbers, J.; Agostini, F.; Maouloud, S. E. M. Ahmed; Alfonsi, M.; Althueser, L.; Amaro, F.; Angevaare, J.; Antochi, V. C.; Antunovic, B.; Aprile, E.; Arazi, L.; Arneodo, F.; Balzer, M.; Baudis, L.; Baur, D.; Benabderrahmane, M. L.; Biondi, Y.; Bismark, A.; Bourgeois, C.; Breskin, A.; Breur, P. A.; Brown, A.; Brown, E.; Bruno, G.; Brünner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J.; Cichon, D.; Clark, M.; Colijn, A. P.; Conrad, J.; Cuenca-García, J. J.; Cussonneau, J. P.; Decowski, M. P.; Depoian, A.; Dierle, J.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Douillet, D.; Drexlin, G.; Eitel, K.; Engel, R.; Erdal, E.; Ferella, A. D.; Fischer, H.; Fischer, P.; Fulgione, W.; Gaemers, P.; Galloway, M.; Gao, F.; Giovagnoli, D.; Girard, F.; Glade-Beucke, R.; Glück, F.; Grandi, L.; Grohmann, S.; Größle, R.; Gumbsheimer, R.; Hannen, V.; Hansmann-Menzemer, S.; Hils, C.; Holzapfel, B.; Howlett, J.; Iaquaniello, G.; Jörg, F.; Keller, M.; Kellerer, J.; Khundzakishvili, G.; Kilminster, B.; Kleifges, M.; Kleiner, T. K.; Koltmann, G.; Kopec, A.; Kopmann, A.; Krauss, L. M.; Kuger, F.; LaCascio, L.; Landsman, H.; Lang, R. F.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Villalpando, A. Loya; Ma, Y.; Macolino, C.; Mahlstedt, J.; Manfredini, A.; Undagoitia, T. Marrodán; Masbou, J.; Masson, D.; Masson, E.; McFadden, N.; Meinhardt, P.; Meyer, R.; Milosevic, B.; Milutinovic, S.; Molinario, A.; Monteiro, C. M. B.; Morå, K.; Morteau, E.; Mosbacher, Y.; Murra, M.; Newstead, J. L.; Ni, K.; Oberlack, U. G.; Obradovic, M.; Odgers, K.; Ostrovskiy, I.; Palacio, J.; Pandurovic, M.; Pelssers, B.; Peres, R.; Pienaar, J.; Pierre, M.; Pizzella, V.; Plante, G.; Qi, J.; Qin, J.; García, D. Ramírez; Reichard, S. E.; Rupp, N.; Sanchez-Lucas, P.; Santos, J.; Sartorelli, G.; Schulte, D.; Schultz-Coulon, H. -C.; Eißing, H. Schulze; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Sharma, S.; Shen, W.; Silva, M.; Simgen, H.; Steidl, M.; Stern, S.; Subotic, D.; Szabo, P.; Terliuk, A.; Therreau, C.; Thers, D.; Thieme, K.; Toennies, F.; Trotta, R.; Tunnell, C. D.; Valerius, K.; Volta, G.; Vorkapic, D.; Weber, M.; Wei, Y.; Weinheimer, C.; Weiss, M.; Wenz, D.; Wittweg, C.; Wolf, J.; Wuestling, S.; Wurm, M.; Xing, Y.; Zhu, T.; Zhu, Y.; Zopounidis, J. P.; Zuber, K.
Comments: 9 pages, 4 figures; for associated data files, see https://github.com/Physik-Institut-UZH/DARWIN-Sensitivity-Studies/tree/master/solar_neutrinos_electron_scattering
Submitted: 2020-06-04
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would benefit from a depleted target. A high-statistics observation of $pp$ neutrinos would allow us to infer the values of the weak mixing angle, $\sin^2\theta_w$, and the electron-type neutrino survival probability, $P_e$, in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, at an exposure of 300 ty. An observation of $pp$ and $^7$Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high (GS98) and low metallicity (AGS09) solar models with 2.1-2.5$\sigma$ significance, independent of external measurements from other experiments or a measurement of $^8$B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of $^{131}$Xe.
[2]  oai:arXiv.org:1708.07051  [pdf] - 1697916
The XENON1T Dark Matter Experiment
XENON Collaboration; Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Antunes, B.; Arneodo, F.; Balata, M.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breskin, A.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Chiarini, A.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Corrieri, R.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Disdier, J. -M.; Doets, M.; Duchovni, E.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Florin, D.; Front, D.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Giboni, K. -L.; Goetzke, L. W.; Grandi, L.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Huhmann, C.; Itay, R.; James, A.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Maier, R.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Morå, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Orlandi, D.; Othegraven, R.; Pakarha, P.; Parlati, S.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M. -C.; Plante, G.; Priel, N.; García, D. Ramírez; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Saldahna, R.; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Sivers, M. v.; Stern, M.; Stein, A.; Tatananni, D.; Tatananni, L.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Upole, N.; Vargas, M.; Wack, O.; Walet, R.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wittweg, C.; Wulf, J.; Ye, J.; Zhang, Y.
Comments: 22 pages, 25 figures
Submitted: 2017-08-23
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented.
[3]  oai:arXiv.org:1606.07001  [pdf] - 1525702
DARWIN: towards the ultimate dark matter detector
Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Amsler, C.; Aprile, E.; Arazi, L.; Arneodo, F.; Barrow, P.; Baudis, L.; Benabderrahmane, M. L.; Berger, T.; Beskers, B.; Breskin, A.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Buetikofer, L.; Calven, J.; Cardoso, J. M. R.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; Diglio, S.; Drexlin, G.; Duchovni, E.; Erdal, E.; Eurin, G.; Ferella, A.; Fieguth, A.; Fulgione, W.; Rosso, A. Gallo; Di Gangi, P.; Di Giovanni, A.; Galloway, M.; Garbini, M.; Geis, C.; Glueck, F.; Grandi, L.; Greene, Z.; Grignon, C.; Hasterok, C.; Hannen, V.; Hogenbirk, E.; Howlett, J.; Hilk, D.; Hils, C.; James, A.; Kaminsky, B.; Kazama, S.; Kilminster, B.; Kish, A.; Krauss, L. M.; Landsman, H.; Lang, R. F.; Lin, Q.; Linde, F. L.; Lindemann, S.; Lindner, M.; Lopes, J. A. M.; Undagoitia, T. Marrodan; Masbou, J.; Massoli, F. V.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Mora, K. D.; Morteau, E.; Murra, M.; Naganoma, J.; Newstead, J. L.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; de Perio, P.; Persiani, R.; Piastra, F.; Piro, M. C.; Plante, G.; Rauch, L.; Reichard, S.; Rizzo, A.; Rupp, N.; Santos, J. M. F. Dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schumann, M.; Schreiner, J.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Silva, M. C.; Simgen, H.; Sissol, P.; von Sivers, M.; Thers, D.; Thurn, J.; Tiseni, A.; Trotta, R.; Tunnell, C. D.; Valerius, K.; Vargas, M. A.; Wang, H.; Wei, Y.; Weinheimer, C.; Wester, T.; Wulf, J.; Zhang, Y.; Zhu, T.; Zuber, K.
Comments: 36 pages, 11 figures
Submitted: 2016-06-22
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large mass, low-energy threshold and ultra-low background level will also be sensitive to other rare interactions. It will search for solar axions, galactic axion-like particles and the neutrinoless double-beta decay of 136-Xe, as well as measure the low-energy solar neutrino flux with <1% precision, observe coherent neutrino-nucleus interactions, and detect galactic supernovae. We present the concept of the DARWIN detector and discuss its physics reach, the main sources of backgrounds and the ongoing detector design and R&D efforts.
[4]  oai:arXiv.org:1512.07501  [pdf] - 1395004
Physics reach of the XENON1T dark matter experiment
The XENON collaboration; Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arazi, L.; Arneodo, F.; Balan, C.; Barrow, P.; Baudis, L.; Bauermeister, B.; Berger, T.; Breur, P.; Breskin, A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Contreras, H.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Duchovni, E.; Fattori, S.; Ferella, A. D.; Fieguth, A.; Franco, D.; Fulgione, W.; Galloway, M.; Garbini, M.; Geis, C.; Goetzke, L. W.; Greene, Z.; Grignon, C.; Gross, E.; Hampel, W.; Hasterok, C.; Itay, R.; Kaether, F.; Kaminsky, B.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Calloch, M. Le; Levy, C.; Lindemann, S.; Lindner, M.; Lopes, J. A. M.; Lyashenko, A.; Macmullin, S.; Manfredini, A.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Mayani, D.; Fernandez, A. J. Melgarejo; Meng, Y.; Messina, M.; Micheneau, K.; Miguez, B.; Molinario, A.; Murra, M.; Naganoma, J.; Oberlack, U.; Orrigo, S. E. A.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Simgen, H.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; von Sivers, M.; Wall, R.; Wang, H.; Weber, M.; Wei, Y.; Weinheimer, C.; Wulf, J.; Zhang, Y.
Comments: 36 pages, 18 figures, published by JCAP
Submitted: 2015-12-23, last modified: 2016-04-15
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in $1$ tonne fiducial volume and ($1$, $12$) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm 0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region ($4$, $50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$ from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$ cm$^2$ at m$_\chi$=$50$ GeV/$c^2$.
[5]  oai:arXiv.org:1603.07669  [pdf] - 1542660
First demonstration of VUV-photon detection in liquid xenon with THGEM and GEM-based Liquid Hole Multipliers
Comments: Presented at the 2016 Vienna Conference on Instrumentation. Submitted to the conference proceedings in NIM A
Submitted: 2016-03-24
The bubble-assisted Liquid Hole-Multiplier (LHM) is a recently-introduced detection concept for noble-liquid time projection chambers. In this "local dual-phase" detection element, a gas bubble is supported underneath a perforated electrode (e.g., Thick Gas Electron Multiplier - THGEM, or Gas Electron Multiplier - GEM). Electrons drifting through the holes induce large electroluminescence signals as they pass into the bubble. In this work we report on recent results of THGEM and GEM electrodes coated with cesium iodide and immersed in liquid xenon, allowing - for the first time - the detection of primary VUV scintillation photons in addition to ionization electrons using LHMs.
[6]  oai:arXiv.org:1505.02316  [pdf] - 1284805
Liquid Hole Multipliers: bubble-assisted electroluminescence in liquid xenon
Comments: Submitted to JINST
Submitted: 2015-05-09, last modified: 2015-05-13
In this work we discuss the mechanism behind the large electroluminescence signals observed at relatively low electric fields in the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon. We present strong evidence that the scintillation light is generated in xenon bubbles trapped below the THGEM holes. The process is shown to be remarkably stable over months of operation, providing - under specific thermodynamic conditions - energy resolution similar to that of present dual-phase liquid xenon experiments. The observed mechanism may serve as the basis for the development of Liquid Hole Multipliers (LHMs), capable of producing local charge-induced electroluminescence signals in large-volume single-phase noble-liquid detectors for dark matter and neutrino physics experiments.
[7]  oai:arXiv.org:1406.2374  [pdf] - 940307
Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment
Comments:
Submitted: 2014-06-09, last modified: 2015-02-25
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of $\sim$10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons ($>99.5%$) and showers of secondary particles from muon interactions in the rock ($>70%$). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.
[8]  oai:arXiv.org:1303.4326  [pdf] - 1165339
Unambiguous Identification of the Second 2+ State in 12C and the Structure of the Hoyle State
Comments: Accepted for Publication in the Physical Review Letter
Submitted: 2013-03-18
The second 2+ state of 12C, predicted over fifty years ago as an excitation of the Hoyle state, has been unambiguously identified using the 12C(g,a_0)8Be reaction. The alpha particles produced by the photodisintegration of 12C were detected using an Optical Time Projection Chamber (O-TPC). Data were collected at beam energies between 9.1 and 10.7 MeV using the intense nearly mono-energetic gamma-ray beams at the HIgS facility. The measured angular distributions determine the cross section and the E1-E2 relative phases as a function of energy leading to an unambiguous identification of the second 2+ state in 12C at 10.03(11) MeV, with a total width of 800(130) keV and a ground state gamma-decay width of 60(10) meV; B(E2: 2+ ---> gs) = 0.73(13) e2fm4 [or 0.45(8) W.u.]. The Hoyle state and its rotational 2+ state that are more extended than the ground state of 12C presents a challenge and constraints for models attempting to reveal the nature of three alpha particle states in 12C. Specifically it challenges the ab-initio Lattice Effective Field Theory (L-EFT) calculations that predict similar r.m.s. radii for the ground state and the Hoyle state.
[9]  oai:arXiv.org:1101.1940  [pdf] - 288646
An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With Gamma-Ray Beams at HIgS
Comments: Supported by the Richard F. Goodman Yale-Weizmann Exchange Program, ACWIS, NY, and USDOE grant Numbers: DE-FG02-94ER40870 and DE-FG02-97ER41033
Submitted: 2011-01-10
We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process of helium burning will be performed by exposing the chamber gas to intense nearly mono-energetic gamma-ray beams at the High Intensity Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of 30x30x21 cm^3. Ionization electrons drift towards a double parallel grid avalanche multiplier, yielding charge multiplication and light emission. Avalanche induced photons from N2 emission are collected, intensified and recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional track images. The event's time projection (third coordinate) and the deposited energy are recorded by photomultipliers and by the TPC charge-signal, respectively. A dedicated VME-based data acquisition system and associated data analysis tools were developed to record and analyze these data. The O-TPC has been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd source placed within its volume with a measured energy resolution of 3.0%. Tracks of alpha and 12C particles from the dissociation of 16O and of three alpha-particles from the dissociation of 12C have been measured during initial in-beam test experiments performed at the HIgS facility at Duke University. The full detection system and its performance are described and the results of the preliminary in-beam test experiments are reported.
[10]  oai:arXiv.org:0706.1106  [pdf] - 2001
Toward Application of a Thick Gas Electron Multiplier (THGEM) Readout for a Dark Matter Detector
Comments: To be published in the Proceedings of the 23rd Winter Workshop on Nuclear Dynamics, Big Sky, Montana, February 11-18, 2007. This work is supported by the Yale-Weizmann Collaboration Program of the American Committee on Weizmann Institute of Science (ACWIS), New York
Submitted: 2007-06-07
The Yale-Weizmann collaboration aims to develop a low-radioactivity (low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in measurements to be performed deep underground as for example carried out by the XENON collaboration. A major issue is the background induced by natural radioactivity of present-detector components including the Photo Multiplier Tubes (PMT) made from glass with large U-Th content. We propose to use advanced Thick Gaseous Electron Multipliers (THGEM) recently developed at the Weizmann Institute of Science (WIS). These "hole-multipliers" will measure in a two-phase (liquid/gas) Xe detector electrons extracted into the gas phase from both ionization in the liquid as well as scintillation-induced photoelectrons from a CsI photocathode immersed in LXe. We report on initial tests (in gas) of THGEM made out of Cirlex (Kapton) which is well known to have low Ra-Th content instead of the usual G10 material with high Ra-Th content.
[11]  oai:arXiv.org:physics/0602188  [pdf] - 119148
Amplification and Scintillation Properties of Oxygen-Rich Gas Mixtures for Optical-TPC Applications
Comments: Paper published in the new online only Journal of Instrumentation, JINST. Work supported by: USDOE grant Number DE-FG02-94ER40870, the Yale-Weizmann Collaboration, ACWIS, New-York, the Benoziyo Center for High-Energy Research at the Weizmann Institute, the Israel Science Foundation - project 151/01
Submitted: 2006-02-27, last modified: 2006-05-27
We studied electron amplification and light emission from avalanches in oxygen-containing gas mixtures. The mixtures investigated in this work included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2. Double-Step Parallel Gap (DSPG) multipliers and THick Gas Electron Multipliers (THGEM) were investigated. High light yields were measured from CO2+N2 and CO2+TEA, though with different emission spectra. We observed the characteristic wave-length emission of N2 and of TEA and used a polymer wave-length shifter to convert TEA UV-light into the visible spectrum. The results of these measurements indicate the applicability of optical recording of ionizing tracks in a TPC target-detector designed to study the cross section of the 16O(g,a)12C reaction, a central problem in nuclear astrophysics.
[12]  oai:arXiv.org:nucl-ex/0504003  [pdf] - 118469
Optical Readout Time Projection Chamber (O-TPC) for a Study of Oxygen Formation In Stellar Helium Burning
Comments: Proceedings 21st Winter Workshop on Nuclear Dynamics, Breckenridge, CO, February 5-12, 2005. Work Supported by USDOE Grant No. DE-FG02-94ER40870 and the Yale-Weizmann Collaboration, American Committe on Weizmann Institute of Science
Submitted: 2005-04-01
We are developing an Optical Readout Time Projection Chamber (O-TPC) detector for the study of the 12C(a,g)16O reaction that determines the ratio of carbon to oxygen in helium burning. This ratio is crucial for understanding the final fate of a progenitor star and the nucleosynthesis of elements prior to a Type II supernova; an oxygen rich star is predicted to collapse to a black hole, and a carbon rich star to a neutron star. Type Ia supernovae (SNeIa) are used as standard candles for measuring cosmological distances with the use of an empirical light curve-luminosity stretching factor. It is essential to understand helium burning that yields the carbon/oxygen white dwarf and thus the initial stage of SNeIa. The O-TPC is intended for use with high intensity photon beams extracted from the HIgS/TUNL facility at Duke University to study the 16O(g,a)12C reaction, and thus the direct reaction at energies as low as 0.7 MeV. We are conducting a systematical study of the best oxygen containing gas with light emitting admixture(s) for use in such an O-TPC. Preliminary results with CO_2 + TEA mixture were obtained