Normalized to: Brand, T.
[1]
oai:arXiv.org:1908.00781 [pdf] - 1966924
SIXTE -- The Generic X-ray Instrument Simulation Toolkit
Dauser, Thomas;
Falkner, Sebastian;
Lorenz, Maximilian;
Kirsch, Christian;
Peille, Philippe;
Cucchetti, Edoardo;
Schmid, Christian;
Brand, Thorsten;
Oertel, Mirjam;
Smith, Randall;
Wilms, Jörn
Submitted: 2019-08-02, last modified: 2019-08-08
We give an overview of the SImulation of X-ray TElescopes (SIXTE) software
package, a generic, mission-independent Monte Carlo simulation toolkit for
X-ray astronomical instrumentation. The package is based on a modular approach
for the source definition, the description of the optics, and the detector type
such that new missions can be easily implemented. The targets to be simulated
are stored in a flexible input format called SIMPUT. Based on this source
definition, a sample of photons is produced and then propagated through the
optics. In order to model the detection process, the software toolkit contains
modules for various detector types, ranging from proportional counter and
Si-based detectors, to more complex descriptions like transition edge sensor
(TES) devices. The implementation of characteristic detector effects and a
detailed modeling of the read-out process allow for representative simulations
and therefore enable the analysis of characteristic features, such as for
example pile-up, and their impact on observations. We present an overview of
the implementation of SIXTE from the input source, the imaging, and the
detection process, highlighting the modular approach taken by the SIXTE
software package. In order to demonstrate the capabilities of the simulation
software, we present a selection of representative applications, including the
all-sky survey of eROSITA and a study of pile-up effects comparing the
currently operating XMM-Newton with the planned Athena-WFI instrument. A
simulation of a galaxy cluster with the Athena- X-IFU shows the capability of
SIXTE to predict the expected performance of an observation for a complex
source with a spatially varying spectrum and our current knowledge of the
future instrument.
[2]
oai:arXiv.org:1806.08652 [pdf] - 1755958
Synthetic simulations of the extragalactic sky seen by eROSITA. I.
Pre-launch selection functions from Monte-Carlo simulations
Clerc, N.;
Ramos-Ceja, M. E.;
Ridl, J.;
Lamer, G.;
Brunner, H.;
Hofmann, F.;
Comparat, J.;
Pacaud, F.;
Käfer, F.;
Reiprich, T. H.;
Merloni, A.;
Schmid, C.;
Brand, T.;
Wilms, J.;
Friedrich, P.;
Finoguenov, A.;
Dauser, T.;
Kreykenbohm, I.
Submitted: 2018-06-22
Studies of galaxy clusters provide stringent constraints on models of
structure formation. Provided that selection effects are under control, large
X-ray surveys are well suited to derive cosmological parameters, in particular
those governing the dark energy equation of state. We forecast the capabilities
of the all-sky eROSITA (the extended ROentgen Survey with an Imaging Telescope
Array) survey to be achieved by the early 2020s. We bring special attention to
modeling the entire chain from photon emission to source detection and
cataloguing. The selection function of galaxy clusters for the upcoming eROSITA
mission is investigated by means of extensive and dedicated Monte-Carlo
simulations. Employing a combination of accurate instrument characterization
and of state-of-the-art source detection technique, we determine a cluster
detection efficiency based on the cluster fluxes and sizes. Using this eROSITA
cluster selection function, we find that eROSITA will detect a total of $\sim
10^5$ clusters in the extra-galactic sky. This number of clusters will allow
eROSITA to put stringent constraints on cosmological models. We show that
incomplete assumptions on selection effects, such as neglecting the
distribution of cluster sizes, induce a bias in the derived value of
cosmological parameters. Synthetic simulations of the eROSITA sky capture the
essential characteristics impacting the next-generation galaxy cluster surveys
and they highlight parameters requiring tight monitoring in order to avoid
biases in cosmological analyses.
[3]
oai:arXiv.org:1608.08105 [pdf] - 1467926
The Athena X-ray Integral Field Unit (X-IFU)
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Barcons, Xavier;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rożanska, Agata;
Wilms, Joern;
Barbera, Marco;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Decourchelle, Anne;
Hartog, Roland den;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Renotte, Etienne;
Schaye, Joop;
Shinozaki, Keisuke;
Valenziano, Luca;
Vink, Jacco;
Webb, Natalie;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Du, Michel Le;
Mesnager, Jean-Michel;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Dadina, Mauro;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Miller, Jon;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Torrejon, Jose Miguel;
Geoffray, Hervé;
Hernandez, Isabelle;
Luno, Laure;
Peille, Philippe;
André, Jérôme;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hassin, Jérémie;
Hervet, Gilles;
Maussang, Irwin;
Moueza, Jérôme;
Paillet, Alexis;
Vella, Bruno;
Garrido, Gonzalo Campos;
Damery, Jean-Charles;
Panem, Chantal;
Panh, Johan;
Bandler, Simon;
Biffi, Jean-Marc;
Boyce, Kevin;
Clénet, Antoine;
DiPirro, Michael;
Jamotton, Pierre;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Brand, Thorsten;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Cucchetti, Edoardo
Submitted: 2016-08-29
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for
High-ENergy Astrophysics (Athena) will provide spatially resolved
high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels
over a field of view of 5 arc minute equivalent diameter and a spectral
resolution of 2.5 eV up to 7 keV. In this paper, we first review the core
scientific objectives of Athena, driving the main performance parameters of the
X-IFU, namely the spectral resolution, the field of view, the effective area,
the count rate capabilities, the instrumental background. We also illustrate
the breakthrough potential of the X-IFU for some observatory science goals.
Then we briefly describe the X-IFU design as defined at the time of the mission
consolidation review concluded in May 2016, and report on its predicted
performance. Finally, we discuss some options to improve the instrument
performance while not increasing its complexity and resource demands (e.g.
count rate capability, spectral resolution).
The X-IFU will be provided by an international consortium led by France, The
Netherlands and Italy, with further ESA member state contributions from
Belgium, Finland, Germany, Poland, Spain, Switzerland and two international
partners from the United States and Japan.