Normalized to: Boutelier, M.
[1]
oai:arXiv.org:1010.6198 [pdf] - 1041623
Studying Frequency Relations of kHz QPOs for 4U 1636-53 and Sco X-1:
Observations Confront Theories
Submitted: 2010-10-29
By fitting the frequencies of simultaneous lower and upper kilohertz
Quasi-Periodic Oscillations (kHz QPOs) in two prototype neutron star QPO
sources (4U~1636-536 and Sco X-1), we test the predictive power of all
currently proposed QPO models. Models predict either a linear, power-law or any
other relationship between the two frequencies. We found that for plausible
neutron star parameters (mass and angular momentum), no model can
satisfactorily reproduce the data, leading to very large chi-squared values in
our fittings. Both for 4U~1636-53 and Sco X-1, this is largely due to the fact
that the data significantly differ from a linear relationship. Some models
perform relatively better but still have their own problems. Such a detailed
comparison of data with models shall enable to identify routes for improving
those models further.
[2]
oai:arXiv.org:0908.1098 [pdf] - 1003339
Relativistic Lines and Reflection from the Inner Accretion Disks Around
Neutron Stars
Submitted: 2009-08-07, last modified: 2010-07-06
A number of neutron star low-mass X-ray binaries have recently been
discovered to show broad, asymmetric Fe K emission lines in their X-ray
spectra. These lines are generally thought to be the most prominent part of a
reflection spectrum, originating in the inner part of the accretion disk where
strong relativistic effects can broaden emission lines. We present a
comprehensive, systematic analysis of Suzaku and XMM-Newton spectra of 10
neutron star low-mass X-ray binaries, all of which display broad Fe K emission
lines. Of the 10 sources, 4 are Z sources, 4 are atolls and 2 are accreting
millisecond X-ray pulsars (also atolls). The Fe K lines are well fit by a
relativistic line model for a Schwarzschild metric, and imply a narrow range of
inner disk radii (6 - 15 GM/c^2) in most cases. This implies that the accretion
disk extends close to the neutron star surface over a range of luminosities.
Continuum modeling shows that for the majority of observations, a blackbody
component (plausibly associated with the boundary layer) dominates the X-ray
emission from 8 - 20 keV. Thus it appears likely that this spectral component
produces the majority of the ionizing flux that illuminates the accretion disk.
Therefore, we also fit the spectra with a blurred reflection model, wherein a
blackbody component illuminates the disk. This model fits well in most cases,
supporting the idea that the boundary layer is illuminating a geometrically
thin disk.
[3]
oai:arXiv.org:0909.2990 [pdf] - 1017554
On the distribution of frequency ratios of kHz QPOs
Submitted: 2009-09-16
The width (W), root mean squared amplitude (Rs) of lower and upper kHz
quasi-periodic oscillations (QPOs) from accreting neutron stars vary with
frequency. Similarly, the QPO frequency varies with the source count rate (S).
Hence, the significance of a QPO, scaling as S x Rs^2/W^(1/2) will also depend
on frequency. In addition, the significance also scales up with the square root
of the integration time of the Fourier power density spectrum (T).
Consequently, depending on the way data are considered, kHz QPOs may be
detected only over a limited range of their frequency spans or detected
predominantly at some frequencies, leading potentially to biases in the
observed distributions of frequencies or frequency ratios. Although subject of
much controversy, an observed clustering of QPO frequency ratios around 3/2 in
Sco X-1, also seen in other sources, has been previously used as an argument
supporting resonance based models of neutron star QPOs. In this paper, we
measure how the statistical significance of both kHz QPOs vary with frequency
for three prototype neutron star kHz QPO sources, namely 4U1636-536, 4U0614+091
and Sco X-1. As the significance of QPO detection depends on frequency, we show
that in sensitivity-limited observations (as in the case of the RXTE/PCA), a
simultaneous detection of both the lower and upper kHz QPOs can only be
achieved over limited frequency ranges. As a result, even a uniform
distribution of QPO frequencies will lead to peaks (in particular around 3/2)
in the histogram of frequency ratios. This implies that the observed clustering
of ratios does not provide any evidence for intrinsically preferred frequency
ratios, thus weakening the case for a resonance mechanism at the origin of
neutron star kHz QPOs.
[4]
oai:arXiv.org:0907.3223 [pdf] - 1002962
kHz Quasi-Periodic Oscillations in the low-mass X-ray binary 4U 0614+09
Submitted: 2009-07-18
We report on a comprehensive analysis of the kilohertz (above 300 Hz)
quasi-periodic oscillations (kHz QPOs) detected from the neutron star low-mass
X-ray binary 4U0614+09 with the Rossi X-ray Timing Explorer (RXTE). With a much
larger data set than previously analyzed (all archival data from February 1996
up to October 2007), we first investigate the reality of the 1330 Hz QPO
reported by van Straaten et al. (2000). This QPO would be of particular
interest since it has the highest frequency reported for any source. A thorough
analysis of the same observation fails to confirm the detection. On the other
hand, over our extended data set, the highest QPO frequency we measure for the
upper kHz QPO is at about 1224 Hz; a value which is fully consistent with the
maximum values observed in similar systems. Second, we demonstrate that the
frequency dependence of the quality factor and amplitude of the lower and upper
kHz QPOs follow the systematic trends seen in similar systems (Barret et al.,
2006). In particular, 4U0614+09 shows a drop of the quality factor of the lower
kHz QPO above 700 Hz. If this is due to an approach to the innermost stable
circular orbit, it implies a neutron star mass of about 1.9 solar masses.
Finally, when analyzing the data over fixed durations, we have found a gap in
the frequency distribution of the upper QPO, associated with a local minimum of
its amplitude. A similar gap is not present in the distribution of the lower
QPO frequencies, suggesting some cautions when interpreting frequency ratio
distributions, based on the occurrence of the lower QPO only.
[5]
oai:arXiv.org:0711.4675 [pdf] - 7526
Discovery of the upper kilo-Hz QPO from the X-ray transient Aql X-1
Submitted: 2007-11-29, last modified: 2007-11-30
We report on a comprehensive analysis of the kilo-Hz (>~600 Hz)
quasi-periodic oscillations (kHz QPOs) detected from the neutron star X-ray
transient Aquila X-1 (Aql X-1) with the Rossi X-ray Timing Explorer, between
1997 and 2007. Among kHz QPO sources, Aql X-1 is peculiar because so far only
one kHz QPO has been reported, whereas in most sources, two kHz QPOs are
usually detected (a lower and an upper kHz QPO). The identification of the QPOs
reported so far has therefore been ambiguous, although it has been proposed
that they were likely to be the lower QPO. Following up on previous work, we
confirm the identification of the QPOs previously reported as lower QPOs,
because of their high quality factors and the quality factor versus frequency
dependency, which are similar to those observed in other sources. Combining all
segments of data containing a lower QPO, we detect for the first time an upper
kHz QPO. As in other sources for which the neutron star spin frequency is
larger than 400 Hz (550.25 Hz in Aql X-1), the frequency difference between the
two kHz QPOs is close to half the spin frequency. Based on this result, we
re-examine the link between the neutron star spin and the frequency of the kHz
QPOs, to show that a model in which the separation of the lower and upper QPOs
relates to the neutron star spin frequency is still as good as any comparably
simple model.