Normalized to: Bourdarot, G.
[1]
oai:arXiv.org:2006.04722 [pdf] - 2129410
Toward a large bandwidth photonic correlator for infrared heterodyne
interferometry
Submitted: 2020-06-08
Infrared heterodyne interferometry has been proposed as a practical
alternative for recombining a large number of telescopes over kilometric
baselines in the mid-infrared. However, the current limited correlation
capacities impose strong restrictions on the sensitivity of this appealing
technique. In this paper, we propose to address the problem of transport and
correlation of wide-bandwidth signals over kilometric distances by introducing
photonic processing in infrared heterodyne interferometry. We describe the
architecture of a photonic double-sideband correlator for two telescopes, along
with the experimental demonstration of this concept on a proof-of-principle
test bed. We demonstrate the \textit{a posteriori} correlation of two infrared
signals previously generated on a two-telescope simulator in a double-sideband
photonic correlator. A degradation of the signal-to-noise ratio of $13\%$,
equivalent to a noise factor $\text{NF}=1.15$, is obtained through the
correlator, and the temporal coherence properties of our input signals are
retrieved from these measurements. Our results demonstrate that photonic
processing can be used to correlate heterodyne signals with a potentially large
increase of detection bandwidth. These developments open the way to photonic
processing of wide bandwidth signals for mid-infrared heterodyne
interferometry, in particular for a large number of telescopes and for direct
imager recombiners.
[2]
oai:arXiv.org:1812.09272 [pdf] - 1803021
Experimental test of a 40 cm-long R=100 000 spectrometer for exoplanet
characterisation
Bourdarot, Guillaume;
Coarer, Etienne Le;
Mouillet, David;
Correia, Jean-Jacques;
Jocou, Laurent;
Rabou, Patrick;
Carlotti, Alexis;
Bonfils, Xavier;
Artigau, Etienne;
Vallee, Philippe;
Doyon, Rene;
Forveille, Thierry;
Stadler, Eric;
Magnard, Yves;
Vigan, Arthur
Submitted: 2018-12-21
High-resolution spectroscopy is a key element for present and future
astronomical instrumentation. In particular, coupled to high contrast imagers
and coronagraphs, high spectral resolution enables higher contrast and has been
identified as a very powerful combination to characterise exoplanets, starting
from giant planets now, up to Earth-like planet eventually for the future
instruments. In this context, we propose the implementation of an innovative
echelle spectrometer based on the use of VIPA (Virtually Imaged Phased Array,
Shirasaki 1996). The VIPA itself is a particular kind of Fabry-Perot
interferometer, used as an angular disperser with much greater dispersive power
than common diffraction grating. The VIPA is an efficient, small component (3
cm x 2.4 cm), that takes the very advantage of single mode injection in a
versatile design. The overall instrument presented here is a proof-of-concept
of a compact, high-resolution (R > 80 000) spectrometer, dedicated to the H and
K bands, in the context of the project High-Dispersion Coronagrahy developed at
IPAG. The optical bench has a foot-print of 40 cm x 26 cm ; it is fed by two
Single-Mode Fibers (SMF), one dedicated to the companion, and one to the star
and/or to a calibration channel, and is cooled down to 80 K.
This communication first presents the scientific and instrumental context of
the project, and the principal merit of single-mode operations in
high-resolution spectrometry. After recalling the physical structure of the
VIPA and its implementation in an echelle-spectrometer design, it then details
the optical design of the spectrometer. In conclusion, further steps
(integration, calibration, coupling with adaptive optics) and possible
optimization are briefly presented.
Keywords: Echelle Spectrometer, High Spectral Resolution, Exoplanets,
High-Dispersion Coronography, Infrared, Adaptive Optics, SPHERE
[3]
oai:arXiv.org:1607.01560 [pdf] - 1530963
Experimental demonstration of a crossed cubes nuller for coronagraphy
and interferometry
Submitted: 2016-07-06
In this communication we present the first experimental results obtained on
the Crossed-cubes nuller (CCN), that is a new type of Achromatic phase shifter
(APS) based on a pair of crossed beamsplitter cubes. We review the general
principle of the CCN, now restricted to two interferometric outputs for
achieving better performance, and describe the experimental apparatus developed
in our laboratory. It is cheap, compact, and easy to align. The results
demonstrate a high extinction rate in monochromatic light and confirm that the
device is insensitive to its polarization state. Finally, the first lessons
from the experiment are summarized and discussed in view of future space
missions searching for extra-solar planets located in the habitable zone,
either based on a coronagraphic telescope or a sparse-aperture nulling
interferometer