sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Bourdarot, Guillaume

Normalized to: Bourdarot, G.

3 article(s) in total. 19 co-authors. Median position in authors list is 1,0.

[1]  oai:arXiv.org:2006.04722  [pdf] - 2129410
Toward a large bandwidth photonic correlator for infrared heterodyne interferometry
Comments: 7 pages, 4 figures. Accepted in Astronomy & Astrophysics
Submitted: 2020-06-08
Infrared heterodyne interferometry has been proposed as a practical alternative for recombining a large number of telescopes over kilometric baselines in the mid-infrared. However, the current limited correlation capacities impose strong restrictions on the sensitivity of this appealing technique. In this paper, we propose to address the problem of transport and correlation of wide-bandwidth signals over kilometric distances by introducing photonic processing in infrared heterodyne interferometry. We describe the architecture of a photonic double-sideband correlator for two telescopes, along with the experimental demonstration of this concept on a proof-of-principle test bed. We demonstrate the \textit{a posteriori} correlation of two infrared signals previously generated on a two-telescope simulator in a double-sideband photonic correlator. A degradation of the signal-to-noise ratio of $13\%$, equivalent to a noise factor $\text{NF}=1.15$, is obtained through the correlator, and the temporal coherence properties of our input signals are retrieved from these measurements. Our results demonstrate that photonic processing can be used to correlate heterodyne signals with a potentially large increase of detection bandwidth. These developments open the way to photonic processing of wide bandwidth signals for mid-infrared heterodyne interferometry, in particular for a large number of telescopes and for direct imager recombiners.
[2]  oai:arXiv.org:1812.09272  [pdf] - 1803021
Experimental test of a 40 cm-long R=100 000 spectrometer for exoplanet characterisation
Comments:
Submitted: 2018-12-21
High-resolution spectroscopy is a key element for present and future astronomical instrumentation. In particular, coupled to high contrast imagers and coronagraphs, high spectral resolution enables higher contrast and has been identified as a very powerful combination to characterise exoplanets, starting from giant planets now, up to Earth-like planet eventually for the future instruments. In this context, we propose the implementation of an innovative echelle spectrometer based on the use of VIPA (Virtually Imaged Phased Array, Shirasaki 1996). The VIPA itself is a particular kind of Fabry-Perot interferometer, used as an angular disperser with much greater dispersive power than common diffraction grating. The VIPA is an efficient, small component (3 cm x 2.4 cm), that takes the very advantage of single mode injection in a versatile design. The overall instrument presented here is a proof-of-concept of a compact, high-resolution (R > 80 000) spectrometer, dedicated to the H and K bands, in the context of the project High-Dispersion Coronagrahy developed at IPAG. The optical bench has a foot-print of 40 cm x 26 cm ; it is fed by two Single-Mode Fibers (SMF), one dedicated to the companion, and one to the star and/or to a calibration channel, and is cooled down to 80 K. This communication first presents the scientific and instrumental context of the project, and the principal merit of single-mode operations in high-resolution spectrometry. After recalling the physical structure of the VIPA and its implementation in an echelle-spectrometer design, it then details the optical design of the spectrometer. In conclusion, further steps (integration, calibration, coupling with adaptive optics) and possible optimization are briefly presented. Keywords: Echelle Spectrometer, High Spectral Resolution, Exoplanets, High-Dispersion Coronography, Infrared, Adaptive Optics, SPHERE
[3]  oai:arXiv.org:1607.01560  [pdf] - 1530963
Experimental demonstration of a crossed cubes nuller for coronagraphy and interferometry
Comments: 12 pages
Submitted: 2016-07-06
In this communication we present the first experimental results obtained on the Crossed-cubes nuller (CCN), that is a new type of Achromatic phase shifter (APS) based on a pair of crossed beamsplitter cubes. We review the general principle of the CCN, now restricted to two interferometric outputs for achieving better performance, and describe the experimental apparatus developed in our laboratory. It is cheap, compact, and easy to align. The results demonstrate a high extinction rate in monochromatic light and confirm that the device is insensitive to its polarization state. Finally, the first lessons from the experiment are summarized and discussed in view of future space missions searching for extra-solar planets located in the habitable zone, either based on a coronagraphic telescope or a sparse-aperture nulling interferometer