Normalized to: Bouly, J.
[1]
oai:arXiv.org:1712.04003 [pdf] - 1666796
The NIKA2 instrument at 30-m IRAM telescope: performance and results
Catalano, A.;
Adam, R.;
Ade, P. A. R.;
P.;
André;
Aussel, H.;
Beelen, A.;
Benoit, A.;
Bideaud, A.;
Billot, N.;
Bourrion, O.;
Calvo, M.;
Comis, B.;
De Petris, M.;
Désert, F. -X.;
Doyle, S.;
Driessen, E. F. C.;
Goupy, J.;
Kramer, C.;
Lagache, G.;
Leclercq, S.;
Lestrade, J. -F.;
Macìas-Pérez, J. F.;
Mauskopf, P.;
Mayet, F.;
Monfardini, A.;
Pascale, E.;
Perotto, L.;
Pisano, G.;
Ponthieu, N.;
Revéret, V.;
Ritacco, A.;
Romero, C.;
Roussel, H.;
Ruppin, F.;
Schuster, K.;
Sievers, A.;
Triqueneaux, S.;
Tucker, C.;
Zylka, R.;
Barria, E.;
Bres, G.;
Camus, P.;
Chanthib, P.;
Donnier-Valentin, G.;
Exshaw, O.;
Garde, G.;
Gerardin, A.;
Leggeri, J. -P.;
Levy-Bertrand, F.;
Guttin, C.;
Hoarau, C.;
Grollier, M.;
Mocellin, J. -L.;
Pont, G.;
Rodenas, H.;
Tissot, O.;
Galvez, G.;
John, D.;
Ungerechts, H.;
Sanchez, S.;
Mellado, P.;
Munoz, M.;
Pierfederici, F.;
Penalver, J.;
Navarro, S.;
Bosson, G.;
Bouly, J. -L.;
Bouvier, J.;
Geraci, C.;
Li, C.;
Menu, J.;
Ponchant, N.;
Roni, S.;
Roudier, S.;
Scordillis, J. P.;
Tourres, D.;
Vescovi, C.;
Barbier, A.;
Billon-Pierron, D.;
Adane, A.;
Andrianasolo, A .;
Bracco, A.;
Coiffard, G.;
Evans, R.;
Maury, A.;
Rigby, A.
Submitted: 2017-12-11, last modified: 2018-02-04
The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and
commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band
camera operating with three frequency multiplexed kilo-pixels arrays of Lumped
Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK, designed to
observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and
2 mm). NIKA2 is today an IRAM resident instrument for millimetre astronomy,
such as Intra Cluster Medium from intermediate to distant clusters and so for
the follow-up of Planck satellite detected clusters, high redshift sources and
quasars, early stages of star formation and nearby galaxies emission. We
present an overview of the instrument performance as it has been evaluated at
the end of the commissioning phase.
[2]
oai:arXiv.org:1602.01288 [pdf] - 1530458
NIKEL_AMC: Readout electronics for the NIKA2 experiment
Bourrion, O.;
Benoit, A.;
Bouly, J. L.;
Bouvier, J.;
Bosson, G.;
Calvo, M.;
Catalano, A.;
Goupy, J.;
Li, C.;
Macías-Pérez, J. F.;
Monfardini, A.;
Tourres, D.;
Ponchant, N.;
Vescovi, C.
Submitted: 2016-02-03, last modified: 2016-10-25
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at
the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to
mm-wave astronomy using microwave kinetic inductance detectors (KID) as
sensors. The three arrays installed in the camera, two at 1.25 mm and one at
2.05 mm, feature a total of 3300 KIDs. To instrument these large array of
detectors, a specifically designed electronics, composed of 20 readout boards
and hosted in three microTCA crates, has been developed. The implemented
solution and the achieved performances are presented in this paper. We find
that multiplexing factors of up to 400 detectors per board can be achieved with
homogeneous performance across boards in real observing conditions, and a
factor of more than 3 decrease in volume with respect to previous generations.
[3]
oai:arXiv.org:1311.0616 [pdf] - 1180445
MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional
detection
Santos, D.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Guillaudin, O.;
Lamblin, J.;
Mayet, F.;
Muraz, J. F.;
Richer, J. P.;
Riffard, Q.;
Lebreton, L.;
Maire, D.;
Busto, J.;
Brunner, J.;
Fouchez, D.
Submitted: 2013-11-04
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from neutrons, the ultimate background
for dark matter direct detection. This strategy requires both a precise
measurement of the energy down to a few keV and 3D reconstruction of tracks
down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has
developed in the last years an original prototype detector based on the direct
coupling of large pixelized micromegas with a special developed fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The first bi-chamber prototype has been installed at
Modane, underground laboratory in June 2012. The first undergournd background
events, the gain stability and calibration are shown. The first spectrum of
nuclear recoils showing 3D tracks coming from the radon progeny is presented.
[4]
oai:arXiv.org:1304.2255 [pdf] - 1165808
MIMAC: A micro-tpc matrix for dark matter directional detection
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, C.;
Guillaudin, O.;
Lamblin, J.;
Muraz, J. F.;
Mayet, F.;
Richer, J. P.;
Riffard, Q.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2013-04-08
The dark matter directional detection opens a new field in cosmology bringing
the possibility to build a map of nuclear recoils that would be able to explore
the galactic dark matter halo giving access to a particle characterization of
such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers)
collaboration has developed in the last years an original prototype detector
based on the direct coupling of large pixelized micromegas with a devoted fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The discovery potential of this search strategy is
discussed and illustrated. In June 2012, the first bi-chamber prototype has
been installed at Modane Underground Laboratory (LSM) and the first underground
background events, the gain stability and calibration are shown.
[5]
oai:arXiv.org:1204.1415 [pdf] - 536126
NIKEL: Electronics and data acquisition for kilopixels kinetic
inductance camera
Submitted: 2012-04-06, last modified: 2012-06-08
A prototype of digital frequency multiplexing electronics allowing the real
time monitoring of microwave kinetic inductance detector (MKIDs) arrays for
mm-wave astronomy has been developed. Thanks to the frequency multiplexing, it
can monitor simultaneously 400 pixels over a 500 MHz bandwidth and requires
only two coaxial cables for instrumenting such a large array. The chosen
solution and the performances achieved are presented in this paper.
[6]
oai:arXiv.org:1111.1566 [pdf] - 435178
MIMAC: A micro-tpc matrix project for directional detection of dark
matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-11-07
Directional detection of non-baryonic DarkMatter is a promising search
strategy for discriminating WIMP events from background ones. This strategy
requires both a measurement of the recoil energy down to a few keV and 3D
reconstruction of tracks down to a few mm. The MIMAC project, based on a
micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first
results of a chamber prototype of this matrix, on low energy nuclear recoils
(1H and 19F) obtained with mono-energetic neutron fields are presented. The
discovery potential of this search strategy is illustrated by a realistic case
accessible to MIMAC.
[7]
oai:arXiv.org:1110.4348 [pdf] - 437252
Data acquisition electronics and reconstruction software for real time
3D track reconstruction within the MIMAC project
Submitted: 2011-10-19, last modified: 2011-11-02
Directional detection of non-baryonic Dark Matter requires 3D reconstruction
of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with
either 3He, CF4 or C4H10 has been developed within the MIMAC project. A
dedicated acquisition electronics and a real time track reconstruction software
have been developed to monitor a 512 channel prototype. This autotriggered
electronic uses embedded processing to reduce the data transfer to its useful
part only, i.e. decoded coordinates of hit tracks and corresponding energy
measurements. An acquisition software with on-line monitoring and 3D track
reconstruction is also presented.
[8]
oai:arXiv.org:1109.1675 [pdf] - 1083919
Micromegas detector developments for MIMAC
Ferrer-Ribas, E.;
Attié, D.;
Calvet, D.;
Colas, P.;
Druillole, F.;
Giomataris, Y.;
Iguaz, F. J.;
Mols, J. P.;
Pancin, J.;
Papaevangelou, T.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-09-08, last modified: 2011-09-12
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a
directional TPC. The recent Micromegas efforts towards building a large size
detector will be described, in particular the characterization measurements of
a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout
plane. Track reconstruction with alpha particles will be shown.
[9]
oai:arXiv.org:1103.1321 [pdf] - 371120
Design and construction of a Cherenkov imager for charge measurement of
nuclear cosmic rays
Bourrion, O.;
Bernard, Ch.;
Bondoux, D.;
Bouly, J. L.;
Bouvier, J.;
Boyer, B.;
Brinet, M.;
Buenerd, M.;
Damieux, G.;
Derome, L.;
Eraud, L.;
Foglio, R.;
Fombaron, D.;
Grondin, D.;
Lee, M. H.;
Lutz, L.;
Marton, M.;
Menchaca-Rocha, A.;
Pelissier, A.;
Périé, J. N.;
Putze, A.;
Roudier, S.;
Sallaz-Damaz, Y.;
Seo, E. S.;
Scordilis, J. P.;
Yoon, Y. S.
Submitted: 2011-03-07, last modified: 2011-05-18
A proximity focusing Cherenkov imager called CHERCAM, has been built for the
charge measurement of nuclear cosmic rays with the CREAM instrument. It
consists of a silica aerogel radiator plane across from a detector plane
equipped with 1,600 1" diameter photomultipliers. The two planes are separated
by a ring expansion gap. The Cherenkov light yield is proportional to the
charge squared of the incident particle. The expected relative light collection
accuracy is in the few percents range. It leads to an expected single element
separation over the range of nuclear charge Z of main interest 1 < Z < 26.
CHERCAM is designed to fly with the CREAM balloon experiment. The design of the
instrument and the implemented technical solutions allowing its safe operation
in high altitude conditions (radiations, low pressure, cold) are presented.
[10]
oai:arXiv.org:1102.3265 [pdf] - 399526
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-02-16
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with CF4 and CHF3. The first results on low energy nuclear recoils (H, F)
obtained with a low mono-energetic neutron field are presented. The discovery
potential of this search strategy is discussed and illustrated by a realistic
case accessible to MIMAC.
[11]
oai:arXiv.org:1006.1335 [pdf] - 226516
Data acquisition electronics and reconstruction software for directional
detection of Dark Matter with MIMAC
Submitted: 2010-06-07
Directional detection of galactic Dark Matter requires 3D reconstruction of
low energy nuclear recoils tracks. A dedicated acquisition electronics with
auto triggering feature and a real time track reconstruction software have been
developed within the framework of the MIMAC project of detector. This
auto-triggered acquisition electronic uses embedded processing to reduce data
transfer to its useful part only, i.e. decoded coordinates of hit tracks and
corresponding energy measurements. An acquisition software with on-line
monitoring and 3D track reconstruction is also presented.