sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Bouly, J. L.

Normalized to: Bouly, J.

11 article(s) in total. 139 co-authors, from 1 to 11 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:1712.04003  [pdf] - 1666796
The NIKA2 instrument at 30-m IRAM telescope: performance and results
Comments:
Submitted: 2017-12-11, last modified: 2018-02-04
The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band camera operating with three frequency multiplexed kilo-pixels arrays of Lumped Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK, designed to observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and 2 mm). NIKA2 is today an IRAM resident instrument for millimetre astronomy, such as Intra Cluster Medium from intermediate to distant clusters and so for the follow-up of Planck satellite detected clusters, high redshift sources and quasars, early stages of star formation and nearby galaxies emission. We present an overview of the instrument performance as it has been evaluated at the end of the commissioning phase.
[2]  oai:arXiv.org:1602.01288  [pdf] - 1530458
NIKEL_AMC: Readout electronics for the NIKA2 experiment
Comments: 21 pages; 16 figures
Submitted: 2016-02-03, last modified: 2016-10-25
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays installed in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically designed electronics, composed of 20 readout boards and hosted in three microTCA crates, has been developed. The implemented solution and the achieved performances are presented in this paper. We find that multiplexing factors of up to 400 detectors per board can be achieved with homogeneous performance across boards in real observing conditions, and a factor of more than 3 decrease in volume with respect to previous generations.
[3]  oai:arXiv.org:1311.0616  [pdf] - 1180445
MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection
Comments: Proceedings of the 4th International Conference on Directional Dark Matter Detection CYGNUS2013, held in Toyoma (Japan), June 2013
Submitted: 2013-11-04
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a special developed fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The first bi-chamber prototype has been installed at Modane, underground laboratory in June 2012. The first undergournd background events, the gain stability and calibration are shown. The first spectrum of nuclear recoils showing 3D tracks coming from the radon progeny is presented.
[4]  oai:arXiv.org:1304.2255  [pdf] - 1165808
MIMAC: A micro-tpc matrix for dark matter directional detection
Comments: Proceedings of the 6th Symposium on Large TPCs for low energy rare event detection, Paris, December 2012
Submitted: 2013-04-08
The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a devoted fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The discovery potential of this search strategy is discussed and illustrated. In June 2012, the first bi-chamber prototype has been installed at Modane Underground Laboratory (LSM) and the first underground background events, the gain stability and calibration are shown.
[5]  oai:arXiv.org:1204.1415  [pdf] - 536126
NIKEL: Electronics and data acquisition for kilopixels kinetic inductance camera
Comments: 21 pages, 14 figures
Submitted: 2012-04-06, last modified: 2012-06-08
A prototype of digital frequency multiplexing electronics allowing the real time monitoring of microwave kinetic inductance detector (MKIDs) arrays for mm-wave astronomy has been developed. Thanks to the frequency multiplexing, it can monitor simultaneously 400 pixels over a 500 MHz bandwidth and requires only two coaxial cables for instrumenting such a large array. The chosen solution and the performances achieved are presented in this paper.
[6]  oai:arXiv.org:1111.1566  [pdf] - 435178
MIMAC: A micro-tpc matrix project for directional detection of dark matter
Comments: Proceedings of the 3rd International Conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois- France- June 2011
Submitted: 2011-11-07
Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of this matrix, on low energy nuclear recoils (1H and 19F) obtained with mono-energetic neutron fields are presented. The discovery potential of this search strategy is illustrated by a realistic case accessible to MIMAC.
[7]  oai:arXiv.org:1110.4348  [pdf] - 437252
Data acquisition electronics and reconstruction software for real time 3D track reconstruction within the MIMAC project
Comments: Proceedings of TWEPP-11, Vienna, Austria, 26-30 September 2011
Submitted: 2011-10-19, last modified: 2011-11-02
Directional detection of non-baryonic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with either 3He, CF4 or C4H10 has been developed within the MIMAC project. A dedicated acquisition electronics and a real time track reconstruction software have been developed to monitor a 512 channel prototype. This autotriggered electronic uses embedded processing to reduce the data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.
[8]  oai:arXiv.org:1109.1675  [pdf] - 1083919
Micromegas detector developments for MIMAC
Comments: 8 pages, 7 figures Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011; corrections on author affiliations
Submitted: 2011-09-08, last modified: 2011-09-12
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
[9]  oai:arXiv.org:1103.1321  [pdf] - 371120
Design and construction of a Cherenkov imager for charge measurement of nuclear cosmic rays
Comments: 24 pages, 19 figures
Submitted: 2011-03-07, last modified: 2011-05-18
A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the incident particle. The expected relative light collection accuracy is in the few percents range. It leads to an expected single element separation over the range of nuclear charge Z of main interest 1 < Z < 26. CHERCAM is designed to fly with the CREAM balloon experiment. The design of the instrument and the implemented technical solutions allowing its safe operation in high altitude conditions (radiations, low pressure, cold) are presented.
[10]  oai:arXiv.org:1102.3265  [pdf] - 399526
MIMAC : A micro-tpc matrix for directional detection of dark matter
Comments: 6 pages, Proc. of the fifth international symposium on large TPCs for low energy rare event detection, Paris, France, Dec. 2010. To appear in Journal of Physics
Submitted: 2011-02-16
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. The first results on low energy nuclear recoils (H, F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.
[11]  oai:arXiv.org:1006.1335  [pdf] - 226516
Data acquisition electronics and reconstruction software for directional detection of Dark Matter with MIMAC
Comments: 17 pages, 12 figures
Submitted: 2010-06-07
Directional detection of galactic Dark Matter requires 3D reconstruction of low energy nuclear recoils tracks. A dedicated acquisition electronics with auto triggering feature and a real time track reconstruction software have been developed within the framework of the MIMAC project of detector. This auto-triggered acquisition electronic uses embedded processing to reduce data transfer to its useful part only, i.e. decoded coordinates of hit tracks and corresponding energy measurements. An acquisition software with on-line monitoring and 3D track reconstruction is also presented.