Normalized to: Boudou, N.
[1]
oai:arXiv.org:1602.07941 [pdf] - 1364463
High-resolution tSZ cartography of clusters of galaxies with NIKA at the
IRAM 30-m telescope
Mayet, F.;
Adam, R.;
Adane, A.;
Ade, P.;
André, P.;
Arnaud, M.;
Bartalucci, I.;
Beelen, A.;
Benoît, A.;
Bideaud, A.;
Billot, N.;
Blanquer, G.;
Boudou, N.;
Bourrion, O.;
Calvo, M.;
Catalano, A.;
Coiffard, G.;
Comis, B.;
Cruciani, A.;
Désert, F. -X.;
Doyle, S.;
Goupy, J.;
Hasnoun, B.;
Hermelo, I.;
Kramer, C.;
Lagache, G.;
Leclercq, S.;
Macías-Pérez, J. F.;
Mauskopf, P.;
Monfardini, A.;
Pajot, F.;
Perotto, L.;
Pointecouteau, E.;
Ponthieu, N.;
Pratt, G. W.;
Revéret, V.;
Ritacco, A.;
Rodriguez, L.;
Ruppin, F.;
Schuster, K.;
Sievers, A.;
Triqueneaux, S.;
Tucker, C.;
Zylka, R.
Submitted: 2016-02-25
The thermal Sunyaev-Zeldovich effect (tSZ) is a powerful probe to study
clusters of galaxies and is complementary with respect to X-ray, lensing or
optical observations. Previous arcmin resolution tSZ observations ({\it e.g.}
SPT, ACT and Planck) only enabled detailed studies of the intra-cluster medium
morphology for low redshift clusters ($z < 0.2$). Thus, the development of
precision cosmology with clusters requires high angular resolution observations
to extend the understanding of galaxy cluster towards high redshift. NIKA2 is a
wide-field (6.5 arcmin field of view) dual-band camera, operated at $100 \ {\rm
mK}$ and containing $\sim 3300$ KID (Kinetic Inductance Detectors), designed to
observe the millimeter sky at 150 and 260 GHz, with an angular resolution of 18
and 12 arcsec respectively. The NIKA2 camera has been installed on the IRAM
30-m telescope (Pico Veleta, Spain) in September 2015. The NIKA2 tSZ
observation program will allow us to observe a large sample of clusters (50) at
redshift ranging between 0.5 and 1. As a pathfinder for NIKA2, several clusters
of galaxies have been observed at the IRAM 30-m telescope with the NIKA
prototype to cover the various configurations and observation conditions
expected for NIKA2.
[2]
oai:arXiv.org:1310.6237 [pdf] - 872148
First observation of the thermal Sunyaev-Zel'dovich effect with kinetic
inductance detectors
Adam, R.;
Comis, B.;
Macías-Pérez, J. F.;
Adane, A.;
Ade, P.;
André, P.;
Beelen, A.;
Belier, B.;
Benoît, A.;
Bideaud, A.;
Billot, N.;
Boudou, N.;
Bourrion, O.;
Calvo, M.;
Catalano, A.;
Coiffard, G.;
D'Addabbo, A.;
Désert, F. -X.;
Doyle, S.;
Goupy, J.;
Kramer, C.;
Leclercq, S.;
Martino, J.;
Mauskopf, P.;
Mayet, F.;
Monfardini, A.;
Pajot, F.;
Pascale, E.;
Perotto, L.;
Pointecouteau, E.;
Ponthieu, N.;
Revéret, V.;
Rodriguez, L.;
Savini, G.;
Schuster, K.;
Sievers, A.;
Tucker, C.;
Zylka, R.
Submitted: 2013-10-23, last modified: 2014-09-03
Clusters of galaxies provide valuable information on the evolution of the
Universe and large scale structures. Recent cluster observations via the
thermal Sunyaev-Zel'dovich (tSZ) effect have proven to be a powerful tool to
detect and study them. In this context, high resolution tSZ observations (~
tens of arcsec) are of particular interest to probe intermediate and high
redshift clusters. Observations of the tSZ effect will be carried out with the
millimeter dual-band NIKA2 camera, based on Kinetic Inductance Detectors (KIDs)
to be installed at the IRAM 30-meter telescope in 2015. To demonstrate the
potential of such an instrument, we present tSZ observations with the NIKA
camera prototype, consisting of two arrays of 132 and 224 detectors that
observe at 140 and 240 GHz with a 18.5 and 12.5 arcsec angular resolution,
respectively. The cluster RX J1347.5-1145 was observed simultaneously at 140
and 240 GHz. We used a spectral decorrelation technique to remove the
atmospheric noise and obtain a map of the cluster at 140 GHz. The efficiency of
this procedure has been characterized through realistic simulations of the
observations. The observed 140 GHz map presents a decrement at the cluster
position consistent with the tSZ nature of the signal. We used this map to
study the pressure distribution of the cluster by fitting a gNFW model to the
data. Subtracting this model from the map, we confirm that RX J1347.5-1145 is
an ongoing merger, which confirms and complements previous tSZ and X-ray
observations. For the first time, we demonstrate the tSZ capability of KID
based instruments. The NIKA2 camera with ~ 5000 detectors and a 6.5 arcmin
field of view will be well-suited for in-depth studies of the intra cluster
medium in intermediate to high redshifts, which enables the characterization of
recently detected clusters by the Planck satellite.
[3]
oai:arXiv.org:1409.1137 [pdf] - 864276
High resolution SZ observations at the IRAM 30-m telescope with NIKA
Adam, R.;
Adane, A.;
Ade, P.;
Andrée, P.;
Beelen, A.;
Belier, B.;
Benoît, A.;
Bideaud, A.;
Billot, N.;
Boudou, N.;
Bourrion, O.;
Calvo, M.;
Catalano, A.;
Coiffard, G.;
Comis, B.;
D'Addabbo, A.;
Désert, F. -X.;
Doyle, S.;
Goupy, J.;
Kramer, C.;
Leclercq, S.;
Macías-Pérez, J. F.;
Martino, J.;
Mauskopf, P.;
Mayet, F.;
Monfardini, A.;
Pajot, F.;
Pascale, E.;
Perotto, L.;
Pointecouteau, E.;
Ponthieu, N.;
Revéret, V.;
Rodriguez, L.;
Ruppin, F.;
Savini, G.;
Schuster, K.;
Sievers, A.;
Tucker, C.;
Zylka, R.
Submitted: 2014-09-03
High resolution observations of the thermal Sunyaev-Zel'dovich (tSZ) effect
are necessary to allow the use of clusters of galaxies as a probe for large
scale structures at high redshifts. With its high resolution and dual-band
capability at millimeter wavelengths, the NIKA camera can play a significant
role in this context. NIKA is based on newly developed Kinetic Inductance
Detectors (KIDs) and operates at the IRAM 30m telescope, Pico Veleta, Spain. In
this paper, we give the status of the NIKA camera, focussing on the KID
technology. We then present observations of three galaxy clusters: RX
J1347.5-1145 as a demonstrator of the NIKA capabilities and the recent
observations of CL J1226.9+3332 (z = 0.89) and MACS J0717.5+3745 (z = 0.55). We
also discuss prospects for the final NIKA2 camera, which will have a 6.5
arcminute field of view with about 5000 detectors in two bands at 150 and 260
GHz.
[4]
oai:arXiv.org:1409.0640 [pdf] - 1216624
The NIKA 2012-2014 observing campaigns: control of systematic effects
and results
Catalano, A.;
Adam, R.;
Adane, A.;
Ade, P.;
André, P.;
Beelen, A.;
Belier, B.;
Benôit, A.;
Bideaud, A.;
Billot, N.;
Boudou, N.;
Bourrion, O.;
Calvo, M.;
Coiffard, G.;
Comis, B.;
D'Addabbo, A.;
Désert, F. -X.;
Doyle, S.;
Goupy, J.;
Kramer, C.;
Leclercq, S.;
Macías-Pérez, J. F.;
Martino, J.;
Mauskopf, P.;
Mayet, F.;
Monfardini, A.;
Pajot, F.;
Pascale, E.;
Perotto, L.;
Ponthieu, E. Pointecouteau N.;
Revéret, V.;
Ritacco, A.;
Rodriguez, L.;
Savini, G.;
Schuster, K.;
Sievers, A.;
Tucker, C.;
Zylka, R.
Submitted: 2014-09-02
The New IRAM KID Array (NIKA) is a dual-band camera operating with frequency
multiplexed arrays of Lumped Element Kinetic Inductance Detectors (LEKIDs)
cooled to 100 mK. NIKA is designed to observe the intensity and polarisation of
the sky at 1.25 and 2.14 mm from the IRAM 30 m telescope. We present the
improvements on the control of systematic effects and astrophysical results
made during the last observation campaigns between 2012 and 2014.
[5]
oai:arXiv.org:1402.0260 [pdf] - 862501
Performance and calibration of the NIKA camera at the IRAM 30 m
telescope
Catalano, A.;
Calvo, M.;
Ponthieu, N.;
Adam, R.;
Adane, A.;
Ade, P.;
Andre, P.;
Beelen, A.;
Belier, B.;
Benoit, A.;
Bideaud, A.;
Billot, N.;
Boudou, N.;
Bourrion, O.;
Coiffard, G.;
Comis, B.;
D'Addabbo, A.;
Desert, F. -X.;
Doyle, S.;
Goupy, J.;
Kramer, C.;
Leclercq, S.;
Macias-Perez, J. F.;
Martino, J.;
Mauskopf, P.;
Mayet, F.;
Monfardini, A.;
Pajot, F.;
Pascale, E.;
Perotto, L.;
Reveret, V.;
Rodriguez, L.;
Savini, G.;
Schuster, K.;
Sievers, A.;
Tucker, C.;
Zylka, R.
Submitted: 2014-02-02, last modified: 2014-09-02
The New IRAM KID Array (NIKA) instrument is a dual-band imaging camera
operating with Kinetic Inductance Detectors (KID) cooled at 100 mK. NIKA is
designed to observe the sky at wavelengths of 1.25 and 2.14 mm from the IRAM 30
m telescope at Pico Veleta with an estimated resolution of 13\,arcsec and 18
arcsec, respectively. This work presents the performance of the NIKA camera
prior to its opening to the astrophysical community as an IRAM common-user
facility in early 2014. NIKA is a test bench for the final NIKA2 instrument to
be installed at the end of 2015. The last NIKA observation campaigns on
November 2012 and June 2013 have been used to evaluate this performance and to
improve the control of systematic effects. We discuss here the dynamical tuning
of the readout electronics to optimize the KID working point with respect to
background changes and the new technique of atmospheric absorption correction.
These modifications significantly improve the overall linearity, sensitivity,
and absolute calibration performance of NIKA. This is proved on observations of
point-like sources for which we obtain a best sensitivity (averaged over all
valid detectors) of 40 and 14 mJy.s$^{1/2}$ for optimal weather conditions for
the 1.25 and 2.14 mm arrays, respectively. NIKA observations of well known
extended sources (DR21 complex and the Horsehead nebula) are presented. This
performance makes the NIKA camera a competitive astrophysical instrument.
[6]
oai:arXiv.org:1312.3588 [pdf] - 1202213
Niobium Silicon alloys for Kinetic Inductance Detectors
Calvo, M.;
D'Addabbo, A.;
Monfardini, A.;
Benoit, A.;
Boudou, N.;
Bourrion, O.;
Catalano, A.;
Dumoulin, L.;
Goupy, J.;
Sueur, H. Le;
Marnieros, S.
Submitted: 2013-12-12
We are studying the properties of Niobium Silicon amorphous alloys as a
candidate material for the fabrication of highly sensitive Kinetic Inductance
Detectors (KID), optimized for very low optical loads. As in the case of other
composite materials, the NbSi properties can be changed by varying the relative
amounts of its components. Using a NbSi film with T_c around 1 K we have been
able to obtain the first NbSi resonators, observe an optical response and
acquire a spectrum in the band 50 to 300 GHz. The data taken show that this
material has very high kinetic inductance and normal state surface resistivity.
These properties are ideal for the development of KID. More measurements are
planned to further characterize the NbSi alloy and fully investigate its
potential.
[7]
oai:arXiv.org:1312.2842 [pdf] - 757114
Detection of the tSZ effect with the NIKA camera
Comis, B.;
Adam, R.;
Macías-Pérez, J. F.;
Adane, A.;
Ade, P.;
André, P.;
Beelen, A.;
Belier, B.;
Benoît, A.;
Bideaud, A.;
Billot, N.;
Boudou, N.;
Bourrion, O.;
Calvo, M.;
Catalano, A.;
Coiffard, G.;
D'Addabbo, A.;
Désert, F. -X.;
Doyle, S.;
Goupy, J.;
Kramer, C.;
Leclercq, S.;
Martino, J.;
Mauskopf, P.;
Mayet, F.;
Monfardini, A.;
Pajot, F.;
Pascale, E.;
Perotto, L.;
Pointecouteau, E.;
Ponthieu, N.;
Revéret, V.;
Rodriguez, L.;
Savini, G.;
Schuster, K.;
Sievers, A.;
Tucker, C.;
Zylka, R.
Submitted: 2013-12-10
We present the first detection of the thermal Sunyaev-Zel'dovich (tSZ) effect
from a cluster of galaxies performed with a KIDs (Kinetic Inductance Detectors)
based instrument. The tSZ effect is a distortion of the black body CMB (Cosmic
Microwave Background) spectrum produced by the inverse Compton interaction of
CMB photons with the hot electrons of the ionized intra-cluster medium. The
massive, intermediate redshift cluster RX J1347.5-1145 has been observed using
NIKA (New IRAM KIDs arrays), a dual-band (140 and 240 GHz) mm-wave imaging
camera, which exploits two arrays of hundreds of KIDs: the resonant frequencies
of the superconducting resonators are shifted by mm-wave photons absorption.
This tSZ cluster observation demonstrates the potential of the next generation
NIKA2 instrument, being developed for the 30m telescope of IRAM, at Pico Veleta
(Spain). NIKA2 will have 1000 detectors at 140GHz and 2x2000 detectors at
240GHz, providing in that band also a measurement of the linear polarization.
NIKA2 will be commissioned in 2015.
[8]
oai:arXiv.org:1310.5891 [pdf] - 756591
High speed readout electronics development for frequency-multiplexed
kinetic inductance detector design optimization
Submitted: 2013-10-22, last modified: 2013-11-12
Microwave Kinetic Inductance Detectors (MKID) are a promising solution for
spaceborne mm-wave astronomy. To optimize their design and make them
insensitive to the ballistic phonons created by cosmic-ray interactions in the
substrate, the phonon propagation in silicon must be studied. A dedicated fast
readout electronics, using channelized Digital Down Conversion for monitoring
up to 12 MKIDs over a 100MHz bandwidth was developed. Thanks to the fast ADC
sampling and steep digital filtering, In-phase and Quadrature samples, having a
high dynamic range, are provided at ~2 Msps. This paper describes the technical
solution chosen and the results obtained.
[9]
oai:arXiv.org:1212.4585 [pdf] - 1934839
Development of Lumped Element Kinetic Inductance Detectors for NIKA
Roesch, M.;
Benoit, A.;
Bideaud, A.;
Boudou, N.;
Calvo, M.;
Cruciani, A.;
Doyle, S.;
Leduc, H. G.;
Monfardini, A.;
Swenson, L.;
Leclercq, S.;
Mauskopf, P.;
Schuster, K. F.
Submitted: 2012-12-19
Lumped-element kinetic inductance detectors(LEKIDs) have recently shown
considerable promise as direct absorption mm-wavelength detectors for
astronomical applications. One major research thrust within the N\'eel Iram
Kids Array (NIKA) collaboration has been to investigate the suitability of
these detectors for deployment at the 30-meter IRAM telescope located on Pico
Veleta in Spain. Compared to microwave kinetic inductance detectors (MKID),
using quarter wavelength resonators, the resonant circuit of a LEKID consists
of a discrete inductance and capacitance coupled to a feedline. A high and
constant current density distribution in the inductive part of these resonators
makes them very sensitive. Due to only one metal layer on a silicon substrate,
the fabrication is relatively easy. In order to optimize the LEKIDs for this
application, we have recently probed a wide variety of individual resonator and
array parameters through simulation and physical testing. This included
determining the optimal feed-line coupling, pixel geometry, resonator
distribution within an array (in order to minimize pixel cross-talk), and
resonator frequency spacing. Based on these results, a 144-pixel Aluminum array
was fabricated and tested in a dilution fridge with optical access, yielding an
average optical NEP of ~2E-16 W/Hz^1/2 (best pixels showed NEP = 6E-17 W/Hz^1/2
under 4-8 pW loading per pixel). In October 2010 the second prototype of LEKIDs
has been tested at the IRAM 30 m telescope. A new LEKID geometry for 2
polarizations will be presented. Also first optical measurements of a titanium
nitride array will be discussed.
[10]
oai:arXiv.org:1201.5486 [pdf] - 469493
Kinetic inductance detectors for millimeter and submillimeter astronomy
/ D\'etecteurs \`a inductance cin\'etique pour l'astronomie millim\'etrique
et sub-millim\'etrique
Submitted: 2012-01-26, last modified: 2012-01-27
We present recent developments in Kinetic Inductance Detectors (KID) for
large arrays of detectors. The main application is ground-based millimeter wave
astronomy. We focus in particular, as a case study, on our own experiment: NIKA
(N\'eel IRAM KID Arrays). NIKA is today the best in-the-field experiment using
KID-based instruments, and consists of a dual-band imaging system designed for
the IRAM 30 meter telescope at Pico Veleta. We describe in this article, after
a general context introduction, the KID working principle and the readout
electronics, crucial to take advantage of the intrinsic KID multiplexability.
We conclude with a small subset of the astronomical sources observed
simultaneously at 2 mm and 1.4 mm by NIKA during the last run, held in October
2010.
Nous d\'ecrivons les r\'ecents d\'eveloppements concernant les grandes
matrices de d\'etecteurs \`a inductance cin\'etique (KID) dont l'application
principale est l'astronomie millim\'etrique au sol. Nous d\'etaillons en
particulier notre propre cam\'era : NIKA (N\'eel IRAM KID Arrays) qui est
aujourd'hui l'instrument le plus abouti mettant en oeuvre des KIDs. NIKA est
une cam\'era bi-bande con\c{c}ue pour le radiot\'elescope de 30 m\`etres de
l'IRAM \`a Pico Veleta. Apr\'es avoir d\'ecrit le contexte instrumental dans
lequel ils s'inscrivent, nous expliquerons le principe de fonctionnement des
KIDs et de leur \'electronique de lecture, cruciale pour pouvoir tirer parti de
leur potentiel de muliplexage. Pour finir, nous pr\'esentons quelques exemples
d'observations effectu\'ees par NIKA dans les bandes de 2 mm et 1,4 mm au cours
de la derni\`ere campagne d'observation en octobre 2010.