sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Bonnassieux, Etienne

Normalized to: Bonnassieux, E.

4 article(s) in total. 115 co-authors, from 1 to 2 common article(s). Median position in authors list is 5,5.

[1]  oai:arXiv.org:2003.06273  [pdf] - 2093231
Decoherence in LOFAR-VLBI Beamforming
Comments: 14 pages, 5 figures
Submitted: 2020-03-13
We show that the use of a superstation (a phased array created using multiple stations of an interferometric array) created in post-processing for LOFAR-VLBI observations introduces a direction-dependent loss of signal in the image. We show this effect using simulations and real data. Using the RIME formalism, we characterise it fully, and give limits under which this signal loss is negligible. Finally, we show that we are able to fully predict this effect. We close with guidelines for interferometric observers to avoid this effect in their observations, and a discussion of techniques which could limit this effect or do away with it entirely. The latter in particular will be relevant to the SKA should its long baselines be used to their fullest potential.
[2]  oai:arXiv.org:1911.08904  [pdf] - 2076737
New mysteries and challenges from the Toothbrush relic: wideband observations from 550 MHz to 8 GHz
Comments: Accepted for publication in A&A
Submitted: 2019-11-18, last modified: 2020-03-06
Radio relics are diffuse extended synchrotron sources that originate from shock fronts induced by galaxy cluster mergers. The actual particle acceleration mechanism at the shock fronts is still under debate. The galaxy cluster 1RXS J0603.3+4214 hosts one of the most intriguing examples of radio relics, known as the Toothbrush. We present new wideband radio continuum observations made with uGMRT and VLA. Our new observations, in combination with previously published data, allowed us to carry out a detailed high spatial resolution spectral and curvature analysis of the known diffuse radio emission sources, over a broad range of frequencies. The integrated spectrum of the Toothbrush follows closely a power law over close to 2 decades in frequency, with a spectral index of $-1.16\pm0.02$. We do not find any evidence of spectral steepening below 8 GHz. The subregions of the Toothbrush show an identical spectral slopes, suggesting that observed spectral index is rather set by the distribution of Mach numbers which may have a similar shape at different parts of the shock front. Indeed, numerical simulations show an intriguing similar spectral index, indicating that the radio spectrum is dominated by the average over the inhomogeneities within the shock, with most of the emission coming from the tail of the Mach number distribution. In contrast to the Toothbrush, the spectrum of the fainter relics show a high frequency steepening. The integrated spectrum of the halo follows a power law from 150 MHz to 3 GHz with a spectral index of $-1.16\pm0.04$. We do not find any evidence for spectral curvature, not even in subareas of the halo. This suggest a homogeneous acceleration throughout the cluster volume. Between the brush region of the Toothbrush and the halo, the color-color analysis revealed emission that was consistent with an overlap between the two different spectral regions.
[3]  oai:arXiv.org:1811.07926  [pdf] - 1789604
The LOFAR Two-metre Sky Survey - II. First data release
Shimwell, T. W.; Tasse, C.; Hardcastle, M. J.; Mechev, A. P.; Williams, W. L.; Best, P. N.; Röttgering, H. J. A.; Callingham, J. R.; Dijkema, T. J.; de Gasperin, F.; Hoang, D. N.; Hugo, B.; Mirmont, M.; Oonk, J. B. R.; Prandoni, I.; Rafferty, D.; Sabater, J.; Smirnov, O.; van Weeren, R. J.; White, G. J.; Atemkeng, M.; Bester, L.; Bonnassieux, E.; Brüggen, M.; Brunetti, G.; Chyży, K. T.; Cochrane, R.; Conway, J. E.; Croston, J. H.; Danezi, A.; Duncan, K.; Haverkorn, M.; Heald, G. H.; Iacobelli, M.; Intema, H. T.; Jackson, N.; Jamrozy, M.; Jarvis, M. J.; Lakhoo, R.; Mevius, M.; Miley, G. K.; Morabito, L.; Morganti, R.; Nisbet, D.; Orrú, E.; Perkins, S.; Pizzo, R. F.; Schrijvers, C.; Smith, D. J. B.; Vermeulen, R.; Wise, M. W.; Alegre, L.; Bacon, D. J.; van Bemmel, I. M.; Beswick, R. J.; Bonafede, A.; Botteon, A.; Bourke, S.; Brienza, M.; Rivera, G. Calistro; Cassano, R.; Clarke, A. O.; Conselice, C. J.; Dettmar, R. J.; Drabent, A.; Dumba, C.; Emig, K. L.; Enßlin, T. A.; Ferrari, C.; Garrett, M. A.; Génova-Santos, R. T.; Goyal, A.; Gürkan, G.; Hale, C.; Harwood, J. J.; Heesen, V.; Hoeft, M.; Horellou, C.; Jackson, C.; Kokotanekov, G.; Kondapally, R.; Kunert-Bajraszewska, M.; Mahatma, V.; Mahony, E. K.; Mandal, S.; McKean, J. P.; Merloni, A.; Mingo, B.; Miskolczi, A.; Mooney, S.; Nikiel-Wroczyński, B.; O'Sullivan, S. P.; Quinn, J.; Reich, W.; Roskowiński, C.; Rowlinson, A.; Savini, F.; Saxena, A.; Schwarz, D. J.; Shulevski, A.; Sridhar, S. S.; Stacey, H. R.; Urquhart, S.; van der Wiel, M. H. D.; Varenius, E.; Webster, B.; Wilber, A.
Comments: 16 figures, 1 table and 22 pages. This paper is part of the LOFAR surveys data release 1 and has been accepted for publication in a special edition of A&A that will appear in Feb 2019, volume 622. The catalogues and images from the data release will be publicly available on lofar-surveys.org upon publication of the journal
Submitted: 2018-11-19
The LOFAR Two-metre Sky Survey (LoTSS) is an ongoing sensitive, high-resolution 120-168MHz survey of the entire northern sky for which observations are now 20% complete. We present our first full-quality public data release. For this data release 424 square degrees, or 2% of the eventual coverage, in the region of the HETDEX Spring Field (right ascension 10h45m00s to 15h30m00s and declination 45$^\circ$00$'$00$''$ to 57$^\circ$00$'$00$''$) were mapped using a fully automated direction-dependent calibration and imaging pipeline that we developed. A total of 325,694 sources are detected with a signal of at least five times the noise, and the source density is a factor of $\sim 10$ higher than the most sensitive existing very wide-area radio-continuum surveys. The median sensitivity is S$_{\rm 144 MHz} = 71\,\mu$Jy beam$^{-1}$ and the point-source completeness is 90% at an integrated flux density of 0.45mJy. The resolution of the images is 6$''$ and the positional accuracy is within 0.2$''$. This data release consists of a catalogue containing location, flux, and shape estimates together with 58 mosaic images that cover the catalogued area. In this paper we provide an overview of the data release with a focus on the processing of the LOFAR data and the characteristics of the resulting images. In two accompanying papers we provide the radio source associations and deblending and, where possible, the optical identifications of the radio sources together with the photometric redshifts and properties of the host galaxies. These data release papers are published together with a further $\sim$20 articles that highlight the scientific potential of LoTSS.
[4]  oai:arXiv.org:1711.00421  [pdf] - 1716957
On the variance of radio interferometric calibration solutions: Quality-based Weighting Schemes
Comments: 14 pages, 8 figures. Accepted
Submitted: 2017-11-01, last modified: 2018-02-06
This paper investigates the possibility of improving radio interferometric images using an algorithm inspired by an optical method known as "lucky imaging", which would give more weight to the best-calibrated visibilities used to make a given image. A fundamental relationship between the statistics of interferometric calibration solution residuals and those of the image-plane pixels is derived in this paper. This relationship allows us to understand and describe the statistical properties of the residual image. In this framework, the noise-map can be described as the Fourier transform of the covariance between residual visibilities in a new differential Fourier plane. Image-plane artefacts can be seen as one realisation of the pixel covariance distribution, which can be estimated from the antenna gain statistics. Based on this relationship, we propose a means of improving images made with calibrated visibilities using weighting schemes. This improvement would occur after calibration, but before imaging - it is thus ideally used between major iterations of self-calibration loops. Applying the weighting scheme to simulated data improves the noise level in the final image at negligible computational cost.