sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Bongiorno, S.

Normalized to: Bongiorno, S.

6 article(s) in total. 20 co-authors, from 1 to 5 common article(s). Median position in authors list is 2,5.

[1]  oai:arXiv.org:1303.6666  [pdf] - 1165560
Characterization of Si Hybrid CMOS Detectors for use in the Soft X-ray Band
Comments: 19 pages, 12 figures, 4 tables, accepted for publication in Nuclear Inst. and Methods in Physics Research, A
Submitted: 2013-03-26
We report on the characterization of four Teledyne Imaging Systems HAWAII Hybrid Si CMOS detectors designed for X-ray detection. Three H1RG detectors were studied along with a specially configured H2RG. Read noise measurements were performed, with the lowest result being 7.1 e- RMS. Interpixel capacitive crosstalk (IPC) was measured for the three H1RGs and for the H2RG. The H1RGs had IPC upper limits of 4.0 - 5.5 % (up & down pixels) and 8.7 - 9.7 % (left & right pixels), indicating a clear asymmetry. Energy resolution is reported for two X-ray lines, 1.5 & 5.9 keV, at multiple temperatures between 150 - 210 K. The best resolution measured at 5.9 keV was 250 eV (4.2 %) at 150 K, with IPC contributing significantly to this measured energy distribution. The H2RG, with a unique configuration designed to decrease the capacitive coupling between ROIC pixels, had an IPC of 1.8 +/- 1.0 % indicating a dramatic improvement in IPC with no measurable asymmetry. We also measured dark current as a function of temperature for each detector. For the detector with the lowest dark current, at 150 K, we measured a dark current of 0.020 +/- 0.001 (e- sec-1 pix-1). There is also a consistent break in the fit to the dark current data for each detector. Above 180 K, all the data can be fit by the product of a power law in temperature and an exponential. Below 180 K the dark current decreases more slowly; a shallow power law or constant must be added to each fit, indicating a different form of dark current is dominant in this temperature regime. Dark current figures of merit at 293 K are estimated from the fit for each detector.
[2]  oai:arXiv.org:1207.6317  [pdf] - 1125125
Characterization of an x-ray hybrid CMOS detector with low interpixel capacitive crosstalk
Comments: contribution to proceedings of SPIE Astronomical Telescopes & Instrumentation 2012
Submitted: 2012-07-26
We present the results of x-ray measurements on a hybrid CMOS detector that uses a H2RG ROIC and a unique bonding structure. The silicon absorber array has a 36{\mu}m pixel size, and the readout array has a pitch of 18{\mu}m; but only one readout circuit line is bonded to each 36x36{\mu}m absorber pixel. This unique bonding structure gives the readout an effective pitch of 36{\mu}m. We find the increased pitch between readout bonds significantly reduces the interpixel capacitance of the CMOS detector reported by Bongiorno et al. 2010 and Kenter et al. 2005.
[3]  oai:arXiv.org:1207.6058  [pdf] - 1125092
Recent Progress on Developments and Characterization of Hybrid CMOS X-ray Detectors
Comments: contribution to proceedings of SPIE Astronomical Telescopes & Instrumentation 2012
Submitted: 2012-07-25
Future space-based X-ray telescope missions are likely to have significantly increased demands on detector read out rates due to increased collection area, and there will be a desire to minimize radiation damage in the interests of maintaining spectral resolution. While CCDs have met the requirements of past missions, active pixel sensors are likely to be a standard choice for some future missions due to their inherent radiation hardness and fast, flexible read-out architecture. One form of active pixel sensor is the hybrid CMOS sensor. In a joint program of Penn State University and Teledyne Imaging Sensors, hybrid CMOS sensors have been developed for use as X-ray detectors. Results of this development effort and tests of fabricated detectors will be presented, along with potential applications for future missions.
[4]  oai:arXiv.org:1104.4519  [pdf] - 1053536
A New TeV Binary: The Discovery of an Orbital Period in HESS J0632+057
Comments: 12 pages, 3 figures, accepted to ApJ Letters
Submitted: 2011-04-22, last modified: 2011-07-11
HESS J0632+057 is a variable, point-like source of Very High Energy ($>100$ GeV) gamma-rays located in the Galactic plane. It is positionally coincident with a Be star, it is a variable radio and X-ray source, has a hard X-ray spectrum, and has low radio flux. These properties suggest that the object may be a member of the rare class of TeV/X-ray binary systems. The definitive confirmation of this would be the detection of a periodic orbital modulation of the flux at any wavelength. We have obtained {\it Swift} X-ray telescope observations of the source from MJD 54857 to 55647 (Jan. 2009 - Mar. 2011) to test the hypothesis that HESS J0632+057 is an X-ray/TeV binary. We show that these data exhibit flux modulation with a period of $321 \pm 5$ days and we evaluate the significance of this period by calculating the null hypothesis probability, allowing for stochastic flaring. This periodicity establishes the binary nature of HESS J0632+057.
[5]  oai:arXiv.org:0909.2898  [pdf] - 1017548
Measurements of Si Hybrid CMOS X-Ray Detector Characteristics
Comments: 11 pages, 10 figures
Submitted: 2009-09-15
The development of Hybrid CMOS Detectors (HCDs) for X-Ray telescope focal planes will place them in con- tention with CCDs on future satellite missions due to their faster frame rates, flexible readout scenarios, lower power consumption, and inherent radiation hardness. CCDs have been used with great success on the current generation of X-Ray telescopes (e.g. Chandra, XMM, Suzaku, and Swift). However their bucket-brigade read-out architecture, which transfers charge across the chip with discrete component readout electronics, results in clockrate limited readout speeds that cause pileup (saturation) of bright sources and an inherent susceptibility to radiation induced displacement damage that limits mission lifetime. In contrast, HCDs read pixels with low power, on-chip multiplexer electronics in a random access fashion. Faster frame rates achieved with multi-output readout design will allow the next generation's larger effective area telescopes to observe bright sources free of pileup. Radiation damaged lattice sites effect a single pixel instead of an entire row. Random access, multi-output readout will allow for novel readout modes such as simultaneous bright-source-fast/whole-chip-slow readout. In order for HCDs to be useful as X-Ray detectors, they must show noise and energy resolution performance similar to CCDs while retaining advantages inherent to HCDs. We will report on readnoise, conversion gain, and energy resolution measurements of an X-Ray enhanced Teledyne HAWAII-1RG (H1RG) HCD and describe techniques of H1RG data reduction.
[6]  oai:arXiv.org:0806.3749  [pdf] - 13812
A Pathfinder Instrument for Precision Radial Velocities in the Near-Infrared
Comments: 18 pages, 8 figures, accepted for publication in PASP
Submitted: 2008-06-23
We have designed and tested an in-plane echelle spectrograph configured to investigate precision radial velocities from ground-based near-infrared observations. The spectrograph operates across the spectral range of 0.9-1.7 mm at a spectral resolution of R = 50,000, and uses a liquid nitrogen-cooled HAWAII 1K detector. Repeated measurements of the Earth's rotation via integrated Sunlight with two different instrument arrangements in the near infrared Y band have produced radial velocities with ~10 m/s RMS over a period of several hours. The most recent instrument configuration has achieved an unbinned RMS of 7 m/s and suggests that infrared radial velocity precisions may be able to approach those achieved at optical wavelengths.