Normalized to: Bongiorno, S.
[1]
oai:arXiv.org:1303.6666 [pdf] - 1165560
Characterization of Si Hybrid CMOS Detectors for use in the Soft X-ray
Band
Submitted: 2013-03-26
We report on the characterization of four Teledyne Imaging Systems HAWAII
Hybrid Si CMOS detectors designed for X-ray detection. Three H1RG detectors
were studied along with a specially configured H2RG. Read noise measurements
were performed, with the lowest result being 7.1 e- RMS. Interpixel capacitive
crosstalk (IPC) was measured for the three H1RGs and for the H2RG. The H1RGs
had IPC upper limits of 4.0 - 5.5 % (up & down pixels) and 8.7 - 9.7 % (left &
right pixels), indicating a clear asymmetry. Energy resolution is reported for
two X-ray lines, 1.5 & 5.9 keV, at multiple temperatures between 150 - 210 K.
The best resolution measured at 5.9 keV was 250 eV (4.2 %) at 150 K, with IPC
contributing significantly to this measured energy distribution. The H2RG, with
a unique configuration designed to decrease the capacitive coupling between
ROIC pixels, had an IPC of 1.8 +/- 1.0 % indicating a dramatic improvement in
IPC with no measurable asymmetry. We also measured dark current as a function
of temperature for each detector. For the detector with the lowest dark
current, at 150 K, we measured a dark current of 0.020 +/- 0.001 (e- sec-1
pix-1). There is also a consistent break in the fit to the dark current data
for each detector. Above 180 K, all the data can be fit by the product of a
power law in temperature and an exponential. Below 180 K the dark current
decreases more slowly; a shallow power law or constant must be added to each
fit, indicating a different form of dark current is dominant in this
temperature regime. Dark current figures of merit at 293 K are estimated from
the fit for each detector.
[2]
oai:arXiv.org:1207.6317 [pdf] - 1125125
Characterization of an x-ray hybrid CMOS detector with low interpixel
capacitive crosstalk
Submitted: 2012-07-26
We present the results of x-ray measurements on a hybrid CMOS detector that
uses a H2RG ROIC and a unique bonding structure. The silicon absorber array has
a 36{\mu}m pixel size, and the readout array has a pitch of 18{\mu}m; but only
one readout circuit line is bonded to each 36x36{\mu}m absorber pixel. This
unique bonding structure gives the readout an effective pitch of 36{\mu}m. We
find the increased pitch between readout bonds significantly reduces the
interpixel capacitance of the CMOS detector reported by Bongiorno et al. 2010
and Kenter et al. 2005.
[3]
oai:arXiv.org:1207.6058 [pdf] - 1125092
Recent Progress on Developments and Characterization of Hybrid CMOS
X-ray Detectors
Submitted: 2012-07-25
Future space-based X-ray telescope missions are likely to have significantly
increased demands on detector read out rates due to increased collection area,
and there will be a desire to minimize radiation damage in the interests of
maintaining spectral resolution. While CCDs have met the requirements of past
missions, active pixel sensors are likely to be a standard choice for some
future missions due to their inherent radiation hardness and fast, flexible
read-out architecture. One form of active pixel sensor is the hybrid CMOS
sensor. In a joint program of Penn State University and Teledyne Imaging
Sensors, hybrid CMOS sensors have been developed for use as X-ray detectors.
Results of this development effort and tests of fabricated detectors will be
presented, along with potential applications for future missions.
[4]
oai:arXiv.org:1104.4519 [pdf] - 1053536
A New TeV Binary: The Discovery of an Orbital Period in HESS J0632+057
Submitted: 2011-04-22, last modified: 2011-07-11
HESS J0632+057 is a variable, point-like source of Very High Energy ($>100$
GeV) gamma-rays located in the Galactic plane. It is positionally coincident
with a Be star, it is a variable radio and X-ray source, has a hard X-ray
spectrum, and has low radio flux. These properties suggest that the object may
be a member of the rare class of TeV/X-ray binary systems. The definitive
confirmation of this would be the detection of a periodic orbital modulation of
the flux at any wavelength. We have obtained {\it Swift} X-ray telescope
observations of the source from MJD 54857 to 55647 (Jan. 2009 - Mar. 2011) to
test the hypothesis that HESS J0632+057 is an X-ray/TeV binary. We show that
these data exhibit flux modulation with a period of $321 \pm 5$ days and we
evaluate the significance of this period by calculating the null hypothesis
probability, allowing for stochastic flaring. This periodicity establishes the
binary nature of HESS J0632+057.
[5]
oai:arXiv.org:0909.2898 [pdf] - 1017548
Measurements of Si Hybrid CMOS X-Ray Detector Characteristics
Submitted: 2009-09-15
The development of Hybrid CMOS Detectors (HCDs) for X-Ray telescope focal
planes will place them in con- tention with CCDs on future satellite missions
due to their faster frame rates, flexible readout scenarios, lower power
consumption, and inherent radiation hardness. CCDs have been used with great
success on the current generation of X-Ray telescopes (e.g. Chandra, XMM,
Suzaku, and Swift). However their bucket-brigade read-out architecture, which
transfers charge across the chip with discrete component readout electronics,
results in clockrate limited readout speeds that cause pileup (saturation) of
bright sources and an inherent susceptibility to radiation induced displacement
damage that limits mission lifetime. In contrast, HCDs read pixels with low
power, on-chip multiplexer electronics in a random access fashion. Faster frame
rates achieved with multi-output readout design will allow the next
generation's larger effective area telescopes to observe bright sources free of
pileup. Radiation damaged lattice sites effect a single pixel instead of an
entire row. Random access, multi-output readout will allow for novel readout
modes such as simultaneous bright-source-fast/whole-chip-slow readout. In order
for HCDs to be useful as X-Ray detectors, they must show noise and energy
resolution performance similar to CCDs while retaining advantages inherent to
HCDs. We will report on readnoise, conversion gain, and energy resolution
measurements of an X-Ray enhanced Teledyne HAWAII-1RG (H1RG) HCD and describe
techniques of H1RG data reduction.
[6]
oai:arXiv.org:0806.3749 [pdf] - 13812
A Pathfinder Instrument for Precision Radial Velocities in the
Near-Infrared
Submitted: 2008-06-23
We have designed and tested an in-plane echelle spectrograph configured to
investigate precision radial velocities from ground-based near-infrared
observations. The spectrograph operates across the spectral range of 0.9-1.7 mm
at a spectral resolution of R = 50,000, and uses a liquid nitrogen-cooled
HAWAII 1K detector. Repeated measurements of the Earth's rotation via
integrated Sunlight with two different instrument arrangements in the near
infrared Y band have produced radial velocities with ~10 m/s RMS over a period
of several hours. The most recent instrument configuration has achieved an
unbinned RMS of 7 m/s and suggests that infrared radial velocity precisions may
be able to approach those achieved at optical wavelengths.