Normalized to: Bonetti, J.
[1]
oai:arXiv.org:1502.00619 [pdf] - 1300145
Antenna-coupled TES bolometers used in BICEP2, Keck array, and SPIDER
Ade, P. A. R.;
Aikin, R. W.;
Amiri, M.;
Barkats, D.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Buder, I.;
Bullock, E.;
Chattopadhyay, G.;
Davis, G.;
Day, P. K.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hristov, V.;
Hui, H.;
Irwin, K. D.;
Jones, W. C.;
Karkare, K. S.;
Kaufman, J. P.;
Keating, B. G.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leduc, H. G.;
Leitch, E. M.;
Llombart, N.;
Lueker, M.;
Mason, P.;
Megerian, K.;
Moncelsi, L.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Orlando, A.;
Pryke, C.;
Rahlin, A. S.;
Reintsema, C. D.;
Richter, S.;
Runyan, M. C.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Sudiwala, R. V.;
Teply, G. P.;
Tolan, J. E.;
Trangsrud, A.;
Tucker, R. S.;
Turner, A. D.;
Vieregg, A. G.;
Weber, A.;
Wiebe, D. V.;
Wilson, P.;
Wong, C. L.;
Yoon, K. W.;
Zmuidzinas, J.
Submitted: 2015-02-02
We have developed antenna-coupled transition-edge sensor (TES) bolometers for
a wide range of cosmic microwave background (CMB) polarimetry experiments,
including BICEP2, Keck Array, and the balloon borne SPIDER. These detectors
have reached maturity and this paper reports on their design principles,
overall performance, and key challenges associated with design and production.
Our detector arrays repeatedly produce spectral bands with 20%-30% bandwidth at
95, 150, or 220~GHz. The integrated antenna arrays synthesize symmetric
co-aligned beams with controlled side-lobe levels. Cross-polarized response on
boresight is typically ~0.5%, consistent with cross-talk in our multiplexed
readout system. End-to-end optical efficiencies in our cameras are routinely
35% or higher, with per detector sensitivities of NET~300 uKrts. Thanks to the
scalability of this design, we have deployed 2560 detectors as 1280 matched
pairs in Keck Array with a combined instantaneous sensitivity of ~9 uKrts, as
measured directly from CMB maps in the 2013 season. Similar arrays have
recently flown in the SPIDER instrument, and development of this technology is
ongoing.
[2]
oai:arXiv.org:1106.3087 [pdf] - 659433
SPIDER: Probing the Early Universe with a Suborbital Polarimeter
Fraisse, A. A.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S.;
Burger, B.;
Chiang, H. C.;
Clark, C. N.;
Contaldi, C. R.;
Crill, B. P.;
Davis, G.;
Doré, O.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Gandilo, N. N.;
Golwala, S.;
Gudmundsson, J. E.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
O'Dea, D. T.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Wiebe, D.
Submitted: 2011-06-15, last modified: 2013-05-02
We evaluate the ability of SPIDER, a balloon-borne polarimeter, to detect a
divergence-free polarization pattern ("B-modes") in the Cosmic Microwave
Background (CMB). In the inflationary scenario, the amplitude of this signal is
proportional to that of the primordial scalar perturbations through the
tensor-to-scalar ratio r. We show that the expected level of systematic error
in the SPIDER instrument is significantly below the amplitude of an interesting
cosmological signal with r=0.03. We present a scanning strategy that enables us
to minimize uncertainty in the reconstruction of the Stokes parameters used to
characterize the CMB, while accessing a relatively wide range of angular
scales. Evaluating the amplitude of the polarized Galactic emission in the
SPIDER field, we conclude that the polarized emission from interstellar dust is
as bright or brighter than the cosmological signal at all SPIDER frequencies
(90 GHz, 150 GHz, and 280 GHz), a situation similar to that found in the
"Southern Hole." We show that two ~20-day flights of the SPIDER instrument can
constrain the amplitude of the B-mode signal to r<0.03 (99% CL) even when
foreground contamination is taken into account. In the absence of foregrounds,
the same limit can be reached after one 20-day flight.
[3]
oai:arXiv.org:1208.1247 [pdf] - 1150545
Antenna-coupled TES bolometers for the Keck Array, Spider, and Polar-1
O'Brient, R.;
Ade, P. A. R.;
Ahmed, Z.;
Aikin, R. W.;
Amiri, M.;
Benton, S.;
Bischoff, C.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Burger, B.;
Davis, G.;
Day, P.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Grayson, J.;
Halpern, M.;
Hasselfield, M.;
Hilton, G.;
Hristov, V. V.;
Hui, H.;
Irwin, K.;
Kernasovskiy, S.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E.;
Lueker, M.;
Megerian, K.;
Moncelsi, L.;
Netterfield, C. B.;
Nguyen, H. T.;
Ogburn, R. W.;
Pryke, C. L.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z.;
Sudiwala, R.;
Teply, G.;
Tolan, J. E.;
Turner, A. D.;
Tucker, R. S.;
Vieregg, A.;
Wiebe, D. V.;
Wilson, P.;
Wong, C. L.;
Wu, W. L. K.;
Yoon, K. W.
Submitted: 2012-08-06
Between the BICEP2 and Keck Array experiments, we have deployed over 1500
dual polarized antenna coupled bolometers to map the Cosmic Microwave
Background's polarization. We have been able to rapidly deploy these detectors
because they are completely planar with an integrated phased-array antenna.
Through our experience in these experiments, we have learned of several
challenges with this technology- specifically the beam synthesis in the
antenna- and in this paper we report on how we have modified our designs to
mitigate these challenges. In particular, we discus differential steering
errors between the polarization pairs' beam centroids due to microstrip cross
talk and gradients of penetration depth in the niobium thin films of our
millimeter wave circuits. We also discuss how we have suppressed side lobe
response with a Gaussian taper of our antenna illumination pattern. These
improvements will be used in Spider, Polar-1, and this season's retrofit of
Keck Array.
[4]
oai:arXiv.org:1208.0857 [pdf] - 1150513
Optimization and sensitivity of the Keck Array
Kernasovskiy, S.;
Ade, P. A. R.;
Aikin, R. W.;
Amiri, M.;
Benton, S.;
Bischoff, C.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Burger, B.;
Davis, G.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hiltion, G.;
Hristov, V. V.;
Irwin, K.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E.;
Lueker, M.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Pryke, C. L.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z.;
Sudiwala, R.;
Teply, G.;
Tolan, J. E.;
Turner, A. D.;
Vieregg, A.;
Wiebe, D. V.;
Wilson, P.;
Wongg, C. L.
Submitted: 2012-08-03
The Keck Array (SPUD) began observing the cosmic microwave background's
polarization in the winter of 2011 at the South Pole. The Keck Array follows
the success of the predecessor experiments Bicep and Bicep2, using five on-axis
refracting telescopes. These have a combined imaging array of 2500
antenna-coupled TES bolometers read with a SQUID-based time domain multiplexing
system. We will discuss the detector noise and the optimization of the readout.
The achieved sensitivity of the Keck Array is 11.5 {\mu}K_(CMB)*sqrt{s} in the
2012 configuration.
[5]
oai:arXiv.org:1208.0844 [pdf] - 1150511
Optical Characterization of the Keck Array Polarimeter at the South Pole
Vieregg, A. G.;
Ade, P. A. R.;
Aikin, R.;
Bischoff, C.;
Bock, J. J.;
Bonetti, J. A.;
Bradford, K. J.;
Brevik, J. A.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Gordon, M. S.;
Halpern, M.;
Hilton, G.;
Hristov, V. V.;
Irwin, K.;
Kernasovskiy, S.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E.;
Lueker, M.;
Montroy, T.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Pryke, C.;
Ruhl, J. E.;
Runyan, M.;
Schwarz, R.;
Sheehy, C.;
Staniszewski, Z.;
Sudiwala, R.;
Teply, G.;
Tolan, J.;
Turner, A. D.;
Wilson, P.;
Wong, C. L.
Submitted: 2012-08-03
The Keck Array (SPUD) is a set of microwave polarimeters that observes from
the South Pole at degree angular scales in search of a signature of Inflation
imprinted as B-mode polarization in the Cosmic Microwave Background (CMB). The
first three Keck Array receivers were deployed during the 2010-2011 Austral
summer, followed by two new receivers in the 2011-2012 summer season,
completing the full five-receiver array. All five receivers are currently
observing at 150 GHz. The Keck Array employs the field-proven BICEP/BICEP2
strategy of using small, cold, on-axis refractive optics, providing excellent
control of systematics while maintaining a large field of view. This design
allows for full characterization of far-field optical performance using
microwave sources on the ground. We describe our efforts to characterize the
main beam shape and beam shape mismatch between co-located
orthogonally-polarized detector pairs, and discuss the implications of measured
differential beam parameters on temperature to polarization leakage in CMB
analysis.
[6]
oai:arXiv.org:1208.0638 [pdf] - 1150486
BICEP2 and Keck Array operational overview and status of observations
Ogburn, R. W.;
Ade, P. A. R.;
Aikin, R. W.;
Amiri, M.;
Benton, S. J.;
Bischoff, C. A.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Bullock, E.;
Burger, B.;
Davis, G.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Fliescher, S.;
Golwala, S. R.;
Gordon, M.;
Halpern, M.;
Hasselfield, M.;
Hilton, G.;
Hristov, V. V.;
Hui, H.;
Irwin, K.;
Kaufman, J. P.;
Keating, B. G.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Leitch, E. M.;
Lueker, M.;
Montroy, T.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Orlando, A.;
Pryke, C. L.;
Reintsema, C.;
Richter, S.;
Ruhl, J. E.;
Runyan, M. C.;
Schwarz, R.;
Sheehy, C. D.;
Staniszewski, Z. K.;
Sudiwala, R. V.;
Teply, G. P.;
Thompson, K.;
Tolan, J. E.;
Turner, A. D.;
Vieregg, A. G.;
Wiebe, D. V.;
Wilson, P.;
Wong, C. L.
Submitted: 2012-08-02
The BICEP2 and Keck Array experiments are designed to measure the
polarization of the cosmic microwave background (CMB) on angular scales of 2-4
degrees (l=50-100). This is the region in which the B-mode signal, a signature
prediction of cosmic inflation, is expected to peak. BICEP2 was deployed to the
South Pole at the end of 2009 and is in the middle of its third year of
observing with 500 polarization-sensitive detectors at 150 GHz. The Keck Array
was deployed to the South Pole at the end of 2010, initially with three
receivers--each similar to BICEP2. An additional two receivers have been added
during the 2011-12 summer. We give an overview of the two experiments, report
on substantial gains in the sensitivity of the two experiments after
post-deployment optimization, and show preliminary maps of CMB polarization
from BICEP2.
[7]
oai:arXiv.org:1106.2507 [pdf] - 372118
Thermal architecture for the SPIDER flight cryostat
Gudmundsson, J. E.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
O'Dea, D.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Gandilo, N. N.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Helson, K. R.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.
Submitted: 2011-06-13
We describe the cryogenic system for SPIDER, a balloon-borne microwave
polarimeter that will map 8% of the sky with degree-scale angular resolution.
The system consists of a 1284 L liquid helium cryostat and a 16 L
capillary-filled superfluid helium tank, which provide base operating
temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption
refrigerators supply sub-Kelvin cooling power to multiple focal planes, which
are housed in monochromatic telescope inserts. The main helium tank is
suspended inside the vacuum vessel with thermally insulating fiberglass
flexures, and shielded from thermal radiation by a combination of two vapor
cooled shields and multi-layer insulation. This system allows for an extremely
low instrumental background and a hold time in excess of 25 days. The total
mass of the cryogenic system, including cryogens, is approximately 1000 kg.
This enables conventional long duration balloon flights. We will discuss the
design, thermal analysis, and qualification of the cryogenic system.
[8]
oai:arXiv.org:1106.2158 [pdf] - 371654
SPIDER: a balloon-borne CMB polarimeter for large angular scales
Filippini, J. P.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S. A.;
Burger, B.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Doré, O.;
Farhang, M.;
Fissel, L. M.;
Gandilo, N. N.;
Golwala, S. R.;
Gudmundsson, J. E.;
Halpern, M.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
O'Dea, D. T.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.
Submitted: 2011-06-10
We describe SPIDER, a balloon-borne instrument to map the polarization of the
millimeter-wave sky with degree angular resolution. Spider consists of six
monochromatic refracting telescopes, each illuminating a focal plane of
large-format antenna-coupled bolometer arrays. A total of 2,624 superconducting
transition-edge sensors are distributed among three observing bands centered at
90, 150, and 280 GHz. A cold half-wave plate at the aperture of each telescope
modulates the polarization of incoming light to control systematics. Spider's
first flight will be a 20-30-day Antarctic balloon campaign in December 2011.
This flight will map \sim8% of the sky to achieve unprecedented sensitivity to
the polarization signature of the gravitational wave background predicted by
inflationary cosmology. The Spider mission will also serve as a proving ground
for these detector technologies in preparation for a future satellite mission.
[9]
oai:arXiv.org:1106.2173 [pdf] - 372068
Design and performance of the Spider instrument
Runyan, M. C.;
Ade, P. A. R.;
Amiri, M.;
Benton, S.;
Bihary, R.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Crill, B. P.;
Dore, O.;
O'Dea, D.;
Farhang, M.;
Filippini, J. P.;
Fissel, L.;
Gandilo, N.;
Golwala, S. R.;
Gudmundsson, J. E.;
Hasselfield, M.;
Halpern, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Morford, T. A.;
Montroy, T. E.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C. D.;
Ruhl, J. E.;
Schenker, M. A.;
Shariff, J.;
Soler, J. D.;
Trangsrud, A.;
Tucker, R. S.;
Tucker, C.;
Turner, A.
Submitted: 2011-06-10
Here we describe the design and performance of the Spider instrument. Spider
is a balloon-borne cosmic microwave background polarization imager that will
map part of the sky at 90, 145, and 280 GHz with sub-degree resolution and high
sensitivity. This paper discusses the general design principles of the
instrument inserts, mechanical structures, optics, focal plane architecture,
thermal architecture, and magnetic shielding of the TES sensors and SQUID
multiplexer. We also describe the optical, noise, and magnetic shielding
performance of the 145 GHz prototype instrument insert.
[10]
oai:arXiv.org:1104.5516 [pdf] - 350687
The Keck Array: a pulse tube cooled CMB polarimeter
Sheehy, C. D.;
Ade, P. A. R.;
Aikin, R. W.;
Amiri, M.;
Benton, S.;
Bischoff, C.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Burger, B.;
Dowell, C. D.;
Duband, L.;
Filippini, J. P.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hilton, G.;
Hristov, V. V.;
Irwin, K.;
Kaufman, J. P.;
Keating, B. G.;
Kovac, J. M.;
Kuo, C. L.;
Lange, A. E.;
Leitch, E. M.;
Lueker, M.;
Netterfield, C. B.;
Nguyen, H. T.;
Ogburn, R. W.;
Orlando, A.;
Pryke, C. L.;
Reintsema, C.;
Richter, S.;
Ruhl, J. E.;
Runyan, M. C.;
Staniszewski, Z.;
Stokes, S.;
Sudiwala, R.;
Teply, G.;
Thompson, K. L.;
Tolan, J. E.;
Turner, A. D.;
Wilson, P.;
Wong, C. L.
Submitted: 2011-04-28
The Keck Array is a cosmic microwave background (CMB) polarimeter that will
begin observing from the South Pole in late 2010. The initial deployment will
consist of three telescopes similar to BICEP2 housed in ultra-compact, pulse
tube cooled cryostats. Two more receivers will be added the following year. In
these proceedings we report on the design and performance of the Keck cryostat.
We also report some initial results on the performance of antenna-coupled TES
detectors operating in the presence of a pulse tube. We find that the
performance of the detectors is not seriously impacted by the replacement of
BICEP2's liquid helium cryostat with a pulse tube cooled cryostat.
[11]
oai:arXiv.org:1102.0559 [pdf] - 1051855
Spider Optimization II: Optical, Magnetic and Foreground Effects
O'Dea, D. T.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bonetti, J. A.;
Bryan, S.;
Burger, B.;
Chiang, H. C.;
Clark, C. N.;
Contaldi, C. R.;
Crill, B. P.;
Davis, G.;
Dore, O.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Gandilo, N. N.;
Golwala, S.;
Gudmundsson, J. E.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K.;
Jones, W. C.;
Kuo, C. L.;
MacTavish, C. J.;
Mason, P. V.;
Montroy, T. E.;
Morford, T. A.;
Netterfield, C. B.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Schenker, M. A.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Wiebe, D.
Submitted: 2011-02-02
Spider is a balloon-borne instrument designed to map the polarization of the
cosmic microwave background (CMB) with degree-scale resolution over a large
fraction of the sky. Spider's main goal is to measure the amplitude of
primordial gravitational waves through their imprint on the polarization of the
CMB if the tensor-to-scalar ratio, r, is greater than 0.03. To achieve this
goal, instrumental systematic errors must be controlled with unprecedented
accuracy. Here, we build on previous work to use simulations of Spider
observations to examine the impact of several systematic effects that have been
characterized through testing and modeling of various instrument components. In
particular, we investigate the impact of the non-ideal spectral response of the
half-wave plates, coupling between focal plane components and the Earth's
magnetic field, and beam mismatches and asymmetries. We also present a model of
diffuse polarized foreground emission based on a three-dimensional model of the
Galactic magnetic field and dust, and study the interaction of this foreground
emission with our observation strategy and instrumental effects. We find that
the expected level of foreground and systematic contamination is sufficiently
low for Spider to achieve its science goals.
[12]
oai:arXiv.org:1009.3685 [pdf] - 1040693
Antenna-coupled TES Bolometer Arrays for BICEP2/Keck and SPIDER
Orlando, A.;
Aikin, R. W;
Amiri, M.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J. A.;
Burger, B.;
Chattopadthyay, G.;
Day, P. K.;
Filippini, J. P.;
Golwala, S. R.;
Halpern, M.;
Hasselfield, M.;
Hilton, G. C.;
Irwin, K. D.;
Kenyon, M.;
Kovac, J. M.;
Kuo, C. L.;
Lange, A. E.;
LeDuc, H. G.;
Llombart, N.;
Nguyen, H. T.;
Ogburn, R. W.;
Reintsema, C. D.;
Runyan, M. C.;
Staniszewski, Z.;
Sudiwala, R.;
Teply, G.;
Trangsrud, A. R.;
Turner, A. D.;
Wilson, P.
Submitted: 2010-09-19
BICEP2/Keck and SPIDER are cosmic microwave background (CMB) polarimeters
targeting the B-mode polarization induced by primordial gravitational waves
from inflation. They will be using planar arrays of polarization sensitive
antenna-coupled TES bolometers, operating at frequencies between 90 GHz and 220
GHz. At 150 GHz each array consists of 64 polarimeters and four of these arrays
are assembled together to make a focal plane, for a total of 256
dual-polarization elements (512 TES sensors). The detector arrays are
integrated with a time-domain SQUID multiplexer developed at NIST and read out
using the multi-channels electronics (MCE) developed at the University of
British Columbia. Following our progress in improving detector parameters
uniformity across the arrays and fabrication yield, our main effort has focused
on improving detector arrays optical and noise performances, in order to
produce science grade focal planes achieving target sensitivities. We report on
changes in detector design implemented to optimize such performances and
following focal plane arrays characterization. BICEP2 has deployed a first 150
GHz science grade focal plane to the South Pole in December 2009.
[13]
oai:arXiv.org:1006.3874 [pdf] - 934286
Modeling and characterization of the SPIDER half-wave plate
Bryan, Sean A.;
Ade, Peter A. R.;
Amiri, Mandana;
Benton, Steve;
Bihary, Richard;
Bock, James J.;
Bond, J. Richard;
Bonetti, Joseph A.;
Chiang, H. Cynthia;
Contaldi, Carlo R.;
Crill, Brendan P.;
O'Dea, Daniel;
Dore, Olivier;
Farhang, Marzieh;
Filippini, Jeffrey P.;
Fissel, Laura;
Gandilo, Natalie;
Golwala, Sunil;
Gudmundsson, Jon E.;
Hasselfield, Matthew;
Halpern, Mark;
Helson, Kyle R.;
Hilton, Gene;
Holmes, Warren;
Hristov, Viktor V.;
Irwin, Kent D.;
Jones, William C.;
Kuo, Chao Lin;
MacTavish, Carrie J.;
Mason, Peter;
Morford, Tracy;
Montroy, Thomas E.;
Netterfield, C. Barth;
Rahlin, Alexandra S.;
Reintsema, Carl D.;
Riley, Daniel;
Ruhl, John E.;
Runyan, Marcus C.;
Schenker, Matthew A.;
Shariff, Jamil;
Soler, Juan Diego;
Trangsrud, Amy;
Tucker, Rebecca;
Tucker, Carole;
Turner, Anthony
Submitted: 2010-06-19
Spider is a balloon-borne array of six telescopes that will observe the
Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the
instrument will make a polarization map of the CMB with approximately one-half
degree resolution at 145 GHz. Polarization modulation is achieved via a
cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have
measured millimeter-wave transmission spectra of the sapphire at room and
cryogenic temperatures. The spectra are consistent with our physical optics
model, and the data gives excellent measurements of the indices of A-cut
sapphire. We have also taken preliminary spectra of the integrated HWP, optical
system, and detectors in the prototype Spider receiver. We calculate the
variation in response of the HWP between observing the CMB and foreground
spectra, and estimate that it should not limit the Spider constraints on
inflation.
[14]
oai:arXiv.org:0908.1464 [pdf] - 27202
Antenna-coupled TES bolometer arrays for CMB polarimetry
Kuo, C. L.;
Bock, J. J.;
Bonetti, J. A.;
Brevik, J.;
Chattopadhyay, G.;
Day, P. K.;
Golwala, S.;
Kenyon, M.;
Lange, A. E.;
LeDuc, H. G.;
Nguyen, H.;
Ogburn, R. W.;
Orlando, A.;
Trangsrud, A.;
Turner, A.;
Wang, G.;
Zmuidzinas, J.
Submitted: 2009-08-11
We describe the design and performance of polarization selective
antenna-coupled TES arrays that will be used in several upcoming Cosmic
Microwave Background (CMB) experiments: SPIDER, BICEP-2/SPUD. The fully
lithographic polarimeter arrays utilize planar phased-antennas for collimation
(F/4 beam) and microstrip filters for band definition (25% bandwidth). These
devices demonstrate high optical efficiency, excellent beam shapes, and
well-defined spectral bands. The dual-polarization antennas provide
well-matched beams and low cross polarization response, both important for
high-fidelity polarization measurements. These devices have so far been
developed for the 100 GHz and 150 GHz bands, two premier millimeter-wave
atmospheric windows for CMB observations. In the near future, the flexible
microstrip-coupled architecture can provide photon noise-limited detection for
the entire frequency range of the CMBPOL mission. This paper is a summary of
the progress we have made since the 2006 SPIE meeting in Orlando, FL.