Normalized to: Bonati, M.
[1]
oai:arXiv.org:1504.02900 [pdf] - 1300165
The Dark Energy Camera
Flaugher, B.;
Diehl, H. T.;
Honscheid, K.;
Abbott, T. M. C.;
Alvarez, O.;
Angstadt, R.;
Annis, J. T.;
Antonik, M.;
Ballester, O.;
Beaufore, L.;
Bernstein, G. M.;
Bernstein, R. A.;
Bigelow, B.;
Bonati, M.;
Boprie, D.;
Brooks, D.;
Buckley-Geer, E. J.;
Campa, J.;
Cardiel-Sas, L.;
Castander, F. J.;
Castilla, J.;
Cease, H.;
Cela-Ruiz, J. M.;
Chappa, S.;
Chi, E.;
Cooper, C.;
da Costa, L. N.;
Dede, E.;
Derylo, G.;
DePoy, D. L.;
de Vicente, J.;
Doel, P.;
Drlica-Wagner, A.;
Eiting, J.;
Elliott, A. E.;
Emes, J.;
Estrada, J.;
Neto, A. Fausti;
Finley, D. A.;
Flores, R.;
Frieman, J.;
Gerdes, D.;
Gladders, M. D.;
Gregory, B.;
Gutierrez, G. R.;
Hao, J.;
Holland, S. E.;
Holm, S.;
Huffman, D.;
Jackson, C.;
James, D. J.;
Jonas, M.;
Karcher, A.;
Karliner, I.;
Kent, S.;
Kessler, R.;
Kozlovsky, M.;
Kron, R. G.;
Kubik, D.;
Kuehn, K.;
Kuhlmann, S.;
Kuk, K.;
Lahav, O.;
Lathrop, A.;
Lee, J.;
Levi, M. E.;
Lewis, P.;
Li, T. S.;
Mandrichenko, I.;
Marshall, J. L.;
Martinez, G.;
Merritt, K. W.;
Miquel, R.;
Munoz, F.;
Neilsen, E. H.;
Nichol, R. C.;
Nord, B.;
Ogando, R.;
Olsen, J.;
Palio, N.;
Patton, K.;
Peoples, J.;
Plazas, A. A.;
Rauch, J.;
Reil, K.;
Rheault, J. -P.;
Roe, N. A.;
Rogers, H.;
Roodman, A.;
Sanchez, E.;
Scarpine, V.;
Schindler, R. H.;
Schmidt, R.;
Schmitt, R.;
Schubnell, M.;
Schultz, K.;
Schurter, P.;
Scott, L.;
Serrano, S.;
Shaw, T. M.;
Smith, R. C.;
Soares-Santos, M.;
Stefanik, A.;
Stuermer, W.;
Suchyta, E.;
Sypniewski, A.;
Tarle, G.;
Thaler, J.;
Tighe, R.;
Tran, C.;
Tucker, D.;
Walker, A. R.;
Wang, G.;
Watson, M.;
Weaverdyck, C.;
Wester, W.;
Woods, R.;
Yanny, B.
Submitted: 2015-04-11
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of
view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on
Cerro Tololo near La Serena, Chile. The camera was designed and constructed by
the Dark Energy Survey Collaboration, and meets or exceeds the stringent
requirements designed for the wide-field and supernova surveys for which the
collaboration uses it. The camera consists of a five element optical corrector,
seven filters, a shutter with a 60 cm aperture, and a CCD focal plane of 250
micron thick fully-depleted CCDs cooled inside a vacuum Dewar. The 570 Mpixel
focal plane comprises 62 2kx4k CCDs for imaging and 12 2kx2k CCDs for guiding
and focus. The CCDs have 15 microns x15 microns pixels with a plate scale of
0.263 arc sec per pixel. A hexapod system provides state-of-the-art focus and
alignment capability. The camera is read out in 20 seconds with 6-9 electrons
readout noise. This paper provides a technical description of the camera's
engineering, construction, installation, and current status.
[2]
oai:arXiv.org:1309.3971 [pdf] - 1179244
CHIRON - A Fiber Fed Spectrometer for Precise Radial Velocities
Submitted: 2013-09-16
The CHIRON optical high-resolution echelle spectrometer was commissioned at
the 1.5m telescope at CTIO in 2011. The instrument was designed for high
throughput and stability, with the goal of monitoring radial velocities of
bright stars with high precision and high cadence for the discovery of low-mass
exoplanets. Spectral resolution of R=79,000 is attained when using a slicer
with a total (including telescope and detector) efficiency of 6% or higher,
while a resolution of R=136,000 is available for bright stars. A fixed spectral
range of 415 to 880 nm is covered. The echelle grating is housed in a vacuum
enclosure and the instrument temperature is stabilized to +-0.2deg. Stable
illumination is provided by an octagonal multimode fiber with excellent
light-scrambling properties. An iodine cell is used for wavelength calibration.
We describe the main optics, fiber feed, detector, exposure-meter, and other
aspects of the instrument, as well as the observing procedure and data
reduction.
[3]
oai:arXiv.org:1111.4717 [pdf] - 1934714
DECam integration tests on telescope simulator
Soares-Santos, M.;
Annis, J.;
Bonati, M.;
Buckley-Geer, E.;
Cease, H.;
DePoy, D.;
Derylo, G.;
Diehl, H. T.;
Elliott, A.;
Estrada, J.;
Finley, D.;
Flaugher, B.;
Frieman, J.;
Hao, J.;
Honscheid, K.;
Karliner, I.;
Krempetz, K.;
Kuehn, K.;
Kuhlmann, S.;
Kuk, K.;
Lin, H.;
Merrit, W.;
Neilsen, E.;
Scott, L.;
Serrano, S.;
Shaw, T.;
Schultz, K.;
Stuermer, W.;
Sypniewski, A.;
Thaler, J.;
Walker, A.;
Walton, J.;
Wester, W.;
Yanny, B.
Submitted: 2011-11-20
The Dark Energy Survey (DES) is a next generation optical survey aimed at
measuring the expansion history of the universe using four probes: weak
gravitational lensing, galaxy cluster counts, baryon acoustic oscillations, and
Type Ia supernovae. To perform the survey, the DES Collaboration is building
the Dark Energy Camera (DECam), a 3 square degree, 570 Megapixel CCD camera
which will be mounted at the Blanco 4-meter telescope at the Cerro Tololo
Inter- American Observatory. DES will survey 5000 square degrees of the
southern galactic cap in 5 filters (g, r, i, z, Y). DECam will be comprised of
74 250 micron thick fully depleted CCDs: 62 2k x 4k CCDs for imaging and 12 2k
x 2k CCDs for guiding and focus. Construction of DECam is nearing completion.
In order to verify that the camera meets technical specifications for DES and
to reduce the time required to commission the instrument, we have constructed a
full sized telescope simulator and performed full system testing and
integration prior to shipping. To complete this comprehensive test phase we
have simulated a DES observing run in which we have collected 4 nights worth of
data. We report on the results of these unique tests performed for the DECam
and its impact on the experiments progress.
[4]
oai:arXiv.org:astro-ph/0608323 [pdf] - 84200
The Automated Palomar 60-Inch Telescope
Cenko, S. Bradley;
Fox, Derek B.;
Moon, Dae-Sik;
Harrison, Fiona A.;
Kulkarni, S. R.;
Henning, John R.;
Guzman, C. Dani;
Bonati, Marco;
Smith, Roger M.;
Thicksten, Robert P.;
Doyle, Michael W.;
Petrie, Hal L.;
Gal-Yam, Avishay;
Soderberg, Alicia M.;
Anagnostou, Nathaniel L.;
Laity, Anastasia C.
Submitted: 2006-08-15
We have converted the Palomar 60-inch telescope (P60) from a classical night
assistant-operated telescope to a fully robotic facility. The automated system,
which has been operational since September 2004, is designed for moderately
fast (t <~ 3 minutes) and sustained (R <~ 23 mag) observations of gamma-ray
burst afterglows and other transient events. Routine queue-scheduled
observations can be interrupted in response to electronic notification of
transient events. An automated pipeline reduces data in real-time, which is
then stored on a searchable web-based archive for ease of distribution. We
describe here the design requirements, hardware and software upgrades, and
lessons learned from roboticization. We present an overview of the current
system performance as well as plans for future upgrades.
[5]
oai:arXiv.org:astro-ph/0601684 [pdf] - 79542
Optical and Near-Infrared Observations of the Peculiar Type Ia Supernova
1999ac
Phillips, Mark M.;
Krisciunas, Kevin;
Suntzeff, Nicholas B.;
Abraham, R. G.;
Beckett, M. G.;
Bonati, M.;
Candia, P.;
Corwin, T. M.;
Depoy, D. L.;
Espinoza, J.;
Firth, A. E.;
Freedman, W. L.;
Galaz, G.;
Germany, L.;
Gonzalez, D.;
Hamuy, M.;
Hastings, N. C.;
Hungerford, A. L.;
Ivanov, V. D.;
Labbe, E.;
Marzke, R. O.;
McCarthy, P. J.;
McMahon, R. G.;
McMillan, R.;
Muena, C.;
Persson, S. E.;
Roth, M.;
Ruiz, M. T.;
Smith, R. C.;
Smith, R.;
Strolger, L. -G.;
Stubbs, C.
Submitted: 2006-01-30
We present 39 nights of optical photometry, 34 nights of infrared photometry,
and 4 nights of optical spectroscopy of the Type Ia SN 1999ac. This supernova
was discovered two weeks before maximum light, and observations were begun
shortly thereafter. At early times its spectra resembled the unusual SN 1999aa
and were characterized by very high velocities in the Ca II H and K lines, but
very low velocities in the Si II 6355 A line. The optical photometry showed a
slow rise to peak brightness but, quite peculiarly, was followed by a more
rapid decline from maximum. Thus, the B- and V-band light curves cannot be
characterized by a single stretch factor. We argue that the best measure of the
nature of this object is not the decline rate parameter Delta m_15 (B). The B-V
colors were unusual from 30 to 90 days after maximum light in that they evolved
to bluer values at a much slower rate than normal Type Ia supernovae. The
spectra and bolometric light curve indicate that this event was similar to the
spectroscopically peculiar slow decliner SN 1999aa.