Normalized to: Bolz, O.
[1]
oai:arXiv.org:0709.3729 [pdf] - 5265
Localising the H.E.S.S. Galactic Centre point source
Submitted: 2007-09-24
Observations by the H.E.S.S. system of imaging atmospheric Cherenkov
telescopes provide the most sensitive measurements of the Galactic Centre
region in the energy range 150 GeV - 30 TeV. The vicinity of the kinetic centre
of our galaxy harbours numerous objects which could potentially accelerate
particles to very high energies (VHE, > 100 GeV) and thus produce the Gamma-ray
flux observed. Within statistical and systematic errors, the centroid of the
point-like emission measured by H.E.S.S. was found to be in good agreement with
the position of the supermassive black hole Sgr A* and the recently discovered
PWN candidate G359.95-0.04. Given a systematic pointing error of about 30'', a
possible association with the SNR Sgr A East could not be ruled out with the
2004 H.E.S.S. data. In this contribution an update is given on the position of
the H.E.S.S. Galactic Centre source using 2005/2006 data. The systematic
pointing error is reduced to 6'' per axis using guiding telescopes for pointing
corrections, making it possible to exclude with high significance Sgr A East as
the source of the VHE Gamma-Rays.
[2]
oai:arXiv.org:astro-ph/0306123 [pdf] - 167007
The Technical Performance of the HEGRA System of Imaging Air Cherenkov
Telescopes
Submitted: 2003-06-05
Between early 1997 and late 2002, the HEGRA collaboration operated a
stereoscopic system of 4 (later 5) imaging atmospheric Cherenkov telescopes. In
this paper we present the calibration schemes which were developed for the
system, and report on the performance of the detector over the years. In
general, the telescope system was very well understood, regarding both the
absolute calibration and the slight changes in performance over the years. The
system had an energy threshold of 500 GeV for observations at zenith and under
optimum detector conditions. With the corresponding calibration schemes, a
systematic accuracy of 15 percent on the absolute energy scale has been
achieved. The continuous sensitivity monitoring provided a relative accuracy of
a few percent, and showed that the threshold did not exceed 600 GeV throughout
the entire operation time. The readout electronics and the imaging quality of
the dishes were well monitored and stable. The absolute pointing had an
accuracy of at least 25 arcsec; this number was guaranteed throughout the whole
lifetime of the experiment.