Normalized to: Boix, J.
[1]
oai:arXiv.org:1909.09342 [pdf] - 1964756
Raman LIDARs for the atmospheric calibration along the line-of-sight of
CTA
Ballester, Otger;
Blanch, Oscar;
Boix, Joan;
Bregeon, Johan;
Brun, Patrick;
Colak, Merve;
Doro, Michele;
Da Deppo, Vania;
Font, Lluis;
Gabella, Omar;
Garcia, Rafael;
Gaug, Markus;
Maggio, Camilla;
Martinez, Manel;
Martinez, Oscar;
Adrover, Pere Munar;
Ramos, Raul;
Rivoire, Stephane;
Stanic, Samo;
Villar, David;
Vasileiadis, George;
Wang, Longlong;
Zavrtanik, Marko
Submitted: 2019-09-20
The Cherenkov Telescope Array (CTA) is the next generation ground based
observatory for gamma ray astronomy at very high energies. Employing more than
100 Imaging Atmospheric Cherenkov Telescopes in the northern and southern
hemispheres, it was designed to reach unprecedented sensitivity and energy
resolution. Understanding and correcting for systematic biases on the absolute
energy scale and instrument response functions will be a crucial issue for the
performance of CTA. The LUPM group and the Spanish/Italian/Slovenian
collaboration are currently building two Raman LIDAR prototypes for the online
atmospheric calibration along the line of sight of the CTA. Requirements for
such a solution include the ability to characterize aerosol extinction at two
wavelengths to distances of 30 km with an accuracy better than 5%, within time
scales of about a minute, steering capabilities and close interaction with the
CTA array control and data acquisition system as well as other auxiliary
instruments. Our Raman LIDARs have design features that make them different
from those used in atmospheric science and are characterized by large
collecting mirrors (2.5 m2), liquid light guides that collect the light at the
focal plane and transport it to the readout system, reduced acquisition time
and highly precise Raman spectrometers. The Raman LIDARs will participate in a
cross calibration and characterization campaign of the atmosphere at the CTA
North site at La Palma, together with other site characterization instruments.
After a one year test period there, an in depth evaluation of the solutions
adopted by the two projects will lead to a final Raman LIDAR design proposal
for both CTA sites.
[2]
oai:arXiv.org:1709.00239 [pdf] - 1587792
Light-Trap: A SiPM Upgrade for Very High Energy Astronomy and Beyond
Guberman, D.;
Cortina, J.;
Ward, J. E.;
Hahn, A.;
Mazin, D.;
Boix, J.;
Dettlaff, A.;
Fink, D.;
Gaweda, J.;
Haberer, W.;
Illa, J.;
Mundet, J.;
Vera, Y.;
Wetteskind, H.
Submitted: 2017-09-01
With the development of the Imaging Atmospheric Cherenkov Technique (IACT),
Gamma-ray astronomy has become one of the most interesting and productive
fields of astrophysics. Current IACT telescope arrays (MAGIC, H.E.S.S, VERITAS)
use photomultiplier tubes (PMTs) to detect the optical/near-UV Cherenkov
radiation emitted due to the interaction of gamma rays with the atmosphere. For
the next generation of IACT experiments, the possibility of replacing the PMTs
with Silicon photomultipliers (SiPMs) is being studied. Among the main
drawbacks of SiPMs are their limited active area (leading to an increase in the
cost and complexity of the camera readout) and their sensitivity to unwanted
wavelengths. Here we propose a novel method to build a relatively low-cost
pixel consisting of a SiPM attached to a PMMA disc doped with a wavelength
shifter. This pixel collects light over a much larger area than a single
standard SiPM and improves sensitivity to near-UV light while simultaneously
rejecting background. We describe the design of a detector that could also have
applications in other fields where detection area and cost are crucial. We
present results of simulations and laboratory measurements of a pixel prototype
and from field tests performed with a 7-pixel cluster installed in a MAGIC
telescope camera.
[3]
oai:arXiv.org:1611.09713 [pdf] - 1532879
Reconfigurable ASIC for a Low Level Trigger System in Cherenkov
Telescope Cameras
Gascon, David;
Barrio, Juan Abel;
Blanch, Oscar;
Boix, Joan;
Delagnes, Eric;
Delgado, Carlos;
Freixas, Lluís;
Guilloux, Fabrice;
López-Coto, Rubén;
Griffiths, Scott;
Martínez, Gustavo;
Martínez, Oscar;
Sanuy, Andreu;
Tejedor, Luis Ángel
Submitted: 2016-11-29
A versatile and reconfigurable ASIC is presented, which implements two
different concepts of low level trigger (L0) for Cherenkov telescopes: the
Majority trigger (sum of discriminated inputs) and the Sum trigger concept
(analogue clipped sum of inputs). Up to 7 input signals can be processed
following one or both of the previous trigger concepts. Each differential pair
output of the discriminator is also available as a LVDS output. Differential
circuitry using local feedback allows the ASIC to achieve high speed (500 MHz)
while maintaining good linearity in a 1 Vpp range. Experimental results are
presented. A number of prototype camera designs of the Cherenkov Telescope
Array (CTA) project will use this ASIC.
[5]
oai:arXiv.org:1307.5092 [pdf] - 1937899
The IFAE/UAB and LUPM Raman LIDARs for Cherenkov Telescope Array
Observatory
López-Oramas, A.;
Abril, O.;
Bigas, O. Blanch;
Boix, J.;
Da Deppo, V.;
Doro, M.;
Font, L.;
Garrido, D.;
Gaug, M.;
Martínez, M.;
Vasileiadis, G.
Submitted: 2013-07-18
The Cherenkov Telescope Array (CTA) is the next generation of Imaging
Atmospheric Cherenkov Telescopes. It will reach a sensitivity and an energy
resolution with no precendent in very high energy gamma-ray astronomy. In order
to achieve this goal, the systematic uncertainties derived from the atmospheric
conditions shall be reduced to the minimum. Different instruments may help
account for these uncertainties. The Barcelona IFAE/UAB (acronyms for Institut
de F\'isica d'Altes Energies and Universitat Aut\`onoma de Barcelona,
respectively) and the Montpellier LUPM (Laboratoire Univers et Particules de
Montpellier) groups are building Raman LIDARs, devices which can reduce the
systematic uncertainties in the reconstruction of the gamma-ray energies from
20$%$ down to 5$%$. The Raman LIDARs subject of this work have coaxial 1.8 m
mirrors with a Nd-YAG laser each. A liquid light-guide collects the light at
the focal plane and transports it to the readout system. We are developping a
monochromator with the purpose of testing the readout chain of both LIDARs.
This device is composed of a system of filters and a photomultiplier, and will
be used to study a particular elastic channel. After characterizing the system,
we will build a polychromator to collect also the sparse Raman signal and will
optimize it to reduce every possible loss of signal. We report on the current
status of the LIDARs development and also the latest results on the different
characterization tests.
[6]
oai:arXiv.org:1307.4545 [pdf] - 1941894
The NectarCAM camera project
Glicenstein, J-F.;
Barcelo, M.;
Barrio, J-A.;
Blanch, O.;
Boix, J.;
Bolmont, J.;
Boutonnet, C.;
Cazaux, S.;
Chabanne, E.;
Champion, C.;
Chateau, F.;
Colonges, S.;
Corona, P.;
Couturier, S.;
Courty, B.;
Delagnes, E.;
Delgado, C.;
Ernenwein, J-P.;
Fegan, S.;
Ferreira, O.;
Fesquet, M.;
Fontaine, G.;
Fouque, N.;
Henault, F.;
Gascón, D.;
Herranz, D.;
Hermel, R.;
Hoffmann, D.;
Houles, J.;
Karkar, S.;
Khelifi, B.;
Knödlseder, J.;
Martinez, G.;
Lacombe, K.;
Lamanna, G.;
LeFlour, T.;
Lopez-Coto, R.;
Louis, F.;
Mathieu, A.;
Moulin, E.;
Nayman, P.;
Nunio, F.;
Olive, J-F.;
Panazol, J-L.;
Petrucci, P-O.;
Punch, M.;
Prast, J.;
Ramon, P.;
Riallot, M.;
Ribó, M.;
Rosier-Lees, S.;
Sanuy, A.;
Siero, J.;
Tavernet, J-P.;
Tejedor, L. A.;
Toussenel, F.;
Vasileiadis, G.;
Voisin, V.;
Waegebert, V.;
Zurbach, C.
Submitted: 2013-07-17
In the framework of the next generation of Cherenkov telescopes, the
Cherenkov Telescope Array (CTA), NectarCAM is a camera designed for the medium
size telescopes covering the central energy range of 100 GeV to 30 TeV.
NectarCAM will be finely pixelated (~ 1800 pixels for a 8 degree field of view,
FoV) in order to image atmospheric Cherenkov showers by measuring the charge
deposited within a few nanoseconds time-window. It will have additional
features like the capacity to record the full waveform with GHz sampling for
every pixel and to measure event times with nanosecond accuracy. An array of a
few tens of medium size telescopes, equipped with NectarCAMs, will achieve up
to a factor of ten improvement in sensitivity over existing instruments in the
energy range of 100 GeV to 10 TeV. The camera is made of roughly 250
independent read-out modules, each composed of seven photo-multipliers, with
their associated high voltage base and control, a read-out board and a
multi-service backplane board. The read-out boards use NECTAr (New Electronics
for the Cherenkov Telescope Array) ASICs which have the dual functionality of
analogue memories and Analogue to Digital Converter (ADC). The camera trigger
to be used will be flexible so as to minimize the read-out dead-time of the
NECTAr chips. We present the camera concept and the design and tests of the
various subcomponents. The design includes the mechanical parts, the cooling of
the electronics, the readout, the data acquisition, the trigger, the monitoring
and services.
[7]
oai:arXiv.org:1307.4565 [pdf] - 1937883
The Cherenkov Telescope Array Large Size Telescope
Ambrosi, G.;
Awane, Y.;
Baba, H.;
Bamba, A.;
Barceló, M.;
de Almeida, U. Barres;
Barrio, J. A.;
Bigas, O. Blanch;
Boix, J.;
Brunetti, L.;
Carmona, E.;
Chabanne, E.;
Chikawa, M.;
Colin, P.;
Conteras, J. L.;
Cortina, J.;
Dazzi, F.;
Deangelis, A.;
Deleglise, G.;
Delgado, C.;
Díaz, C.;
Dubois, F.;
Fiasson, A.;
Fink, D.;
Fouque, N.;
Freixas, L.;
Fruck, C.;
Gadola, A.;
García, R.;
Gascon, D.;
Geffroy, N.;
Giglietto, N.;
Giordano, F.;
Grañena, F.;
Gunji, S.;
Hagiwara, R.;
Hamer, N.;
Hanabata, Y.;
Hassan, T.;
Hatanaka, K.;
Haubold, T.;
Hayashida, M.;
Hermel, R.;
Herranz, D.;
Hirotani, K.;
Inoue, S.;
Inoue, Y.;
Ioka, K.;
Jablonski, C.;
Kagaya, M.;
Katagiri, H.;
Kishimoto, T.;
Kodani, K.;
Kohri, K.;
Konno, Y.;
Koyama, S.;
Kubo, H.;
Kushida, J.;
Lamanna, G.;
Flour, T. Le;
López-Moya, M.;
López, R.;
Lorenz, E.;
Majumdar, P.;
Manalaysay, A.;
Mariotti, M.;
Martínez, G.;
Martínez, M.;
Mazin, D.;
Miranda, J. M.;
Mirzoyan, R.;
Monteiro, I.;
Moralejo, A.;
Murase, K.;
Nagataki, S.;
Nakajima, D.;
Nakamori, T.;
Nishijima, K.;
Noda, K.;
Nozato, A.;
Ohira, Y.;
Ohishi, M.;
Ohoka, H.;
Okumura, A.;
Orito, R.;
Panazol, J. L.;
Paneque, D.;
Paoletti, R.;
Paredes, J. M.;
Pauletta, G.;
Podkladkin, S.;
Prast, J.;
Rando, R.;
Reimann, O.;
Ribó, M.;
Rosier-Lees, S.;
Saito, K.;
Saito, T.;
Saito, Y.;
Sakaki, N.;
Sakonaka, R.;
Sanuy, A.;
Sasaki, H.;
Sawada, M.;
Scalzotto, V.;
Schultz, S.;
Schweizer, T.;
Shibata, T.;
Shu, S.;
Sieiro, J.;
Stamatescu, V.;
Steiner, S.;
Straumann, U.;
Sugawara, R.;
Tajima, H.;
Takami, H.;
Tanaka, S.;
Tanaka, M.;
Tejedor, L. A.;
Terada, Y.;
Teshima, M.;
Totani, T.;
Ueno, H.;
Umehara, K.;
Vollhardt, A.;
Wagner, R.;
Wetteskind, H.;
Yamamoto, T.;
Yamazaki, R.;
Yoshida, A.;
Yoshida, T.;
Yoshikoshi, T.
Submitted: 2013-07-17
The two arrays of the Very High Energy gamma-ray observatory Cherenkov
Telescope Array (CTA) will include four Large Size Telescopes (LSTs) each with
a 23 m diameter dish and 28 m focal distance. These telescopes will enable CTA
to achieve a low-energy threshold of 20 GeV, which is critical for important
studies in astrophysics, astroparticle physics and cosmology. This work
presents the key specifications and performance of the current LST design in
the light of the CTA scientific objectives.
[8]
oai:arXiv.org:1307.3386 [pdf] - 1937869
Development of the Photomultiplier-Tube Readout System for the CTA Large
Size Telescope
Kubo, H.;
Paoletti, R.;
Awane, Y.;
Bamba, A.;
Barcelo, M.;
Barrio, J. A.;
Blanch, O.;
Boix, J.;
Delgado, C.;
Fink, D.;
Gascon, D.;
Gunji, S.;
Hagiwara, R.;
Hanabata, Y.;
Hatanaka, K.;
Hayashida, M.;
Ikeno, M.;
Kabuki, S.;
Katagiri, H.;
Kataoka, J.;
Konno, Y.;
Koyama, S.;
Kishimoto, T.;
Kushida, J.;
Martinez, G.;
Masuda, S.;
Miranda, J. M.;
Mirzoyan, R.;
Mizuno, T.;
Nagayoshi, T.;
Nakajima, D.;
Nakamori, T.;
Ohoka, H.;
Okumura, A.;
Orito, R.;
Saito, T.;
Sanuy, A.;
Sasaki, H.;
Sawada, M.;
Schweizer, T.;
Sugawara, R.;
Sulanke, K. -H.;
Tajima, H.;
Tanaka, M.;
Tanaka, S.;
Tejedor, L. A.;
Terada, Y.;
Teshima, M.;
Tokanai, F.;
Tsuchiya, Y.;
Uchida, T.;
Ueno, H.;
Umehara, K.;
Yamamoto, T.
Submitted: 2013-07-12
We have developed a prototype of the photomultiplier tube (PMT) readout
system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two
thousand PMTs along with their readout systems are arranged on the focal plane
of each telescope, with one readout system per 7-PMT cluster. The Cherenkov
light pulses generated by the air showers are detected by the PMTs and
amplified in a compact, low noise and wide dynamic range gain block. The output
of this block is then digitized at a sampling rate of the order of GHz using
the Domino Ring Sampler DRS4, an analog memory ASIC developed at Paul Scherrer
Institute. The sampler has 1,024 capacitors per channel and four channels are
cascaded for increased depth. After a trigger is generated in the system, the
charges stored in the capacitors are digitized by an external slow sampling ADC
and then transmitted via Gigabit Ethernet. An onboard FPGA controls the DRS4,
trigger threshold, and Ethernet transfer. In addition, the control and
monitoring of the Cockcroft-Walton circuit that provides high voltage for the
7-PMT cluster are performed by the same FPGA. A prototype named Dragon has been
developed that has successfully sampled PMT signals at a rate of 2 GHz, and
generated single photoelectron spectra.
[9]
oai:arXiv.org:1307.3169 [pdf] - 1937868
An Analog Trigger System for Atmospheric Cherenkov Telescopes
Submitted: 2013-07-11
Arrays of Cherenkov telescopes typically use multi-level trigger schemes to
keep the rate of random triggers from the night sky background low. At a first
stage, individual telescopes produce a trigger signal from the pixel
information in the telescope camera. The final event trigger is then formed by
combining trigger signals from several telescopes. In this poster, we present a
possible scheme for the Cherenkov Telescope Array telescope trigger, which is
based on the analog pulse information of the pixels in a telescope camera.
Advanced versions of all components of the system have been produced and
working prototypes have been tested, showing a performance that meets the
original specifications. Finally, issues related to integrating the trigger
system in a telescope camera and in the whole array will be dealt with.