sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Boiano, Alfonso

Normalized to: Boiano, A.

5 article(s) in total. 70 co-authors, from 1 to 4 common article(s). Median position in authors list is 9,0.

[1]  oai:arXiv.org:1910.00133  [pdf] - 1971509
Camera design and performance of the prototype Schwarzschild-Couder Telescope for the Cherenkov Telescope Array
Comments: ICRC 2019 Proceeding
Submitted: 2019-09-30
The Schwarzschild-Couder Telescope (SCT) is a candidate technology for a medium-sized telescope within the Cherenkov Telescope Array, the next generation ground based observatory for very high energy gamma ray astronomy. The SCT uses a novel two-mirror design and is expected to yield improvements in field of view and image resolution compared to traditional Cherenkov telescopes based on single-mirror-dish optics. To match the improved optical resolution, challenging requirements of high channel count and density at low power consumption must be overcome by the camera. The prototype camera, currently commissioned and tested on the prototype SCT, has been developed based on millimeter scale SiPM pixels and a custom high density digitizer ASIC, TARGET, to provide 1600 pixels spanning a 2.7 degree field of view while being able to sample nanosecond photon pulses. It is mechanically designed to allow for an upgrade to 11,328 pixels covering a field of view of 8 degrees and demonstrating the full potential of the technology. The camera was installed on the telescope in 2018. We will present its design and performance including first light data.
[2]  oai:arXiv.org:1909.11403  [pdf] - 1968539
Prototype Schwarzschild-Couder Telescope for the Cherenkov Telescope Array: Commissioning Status of the Optical System
Comments: 8 pages, PoS proceedings 36th ICRC 2019 Madison
Submitted: 2019-09-25
The Cherenkov Telescope Array (CTA), with more than 100 telescopes, will be the largest ever ground-based gamma-ray observatory and is expected to greatly improve on both gamma-ray detection sensitivity and energy coverage compared to current-generation detectors. The 9.7-m Schwarzschild-Couder telescope (SCT) is one of the two candidates for the medium size telescope (MST) design for CTA. The novel aplanatic dual-mirror SCT design offers a wide field-of-view with a compact plate scale, allowing for a large number of camera pixels that improves the angular resolution and reduce the night sky background noise per pixel compared to the traditional single-mirror Davies-Cotton (DC) design of ground-based gamma-ray telescopes. The production, installation, and the alignment of the segmented aspherical mirrors are the main challenges for the realization of the SCT optical system. In this contribution, we report on the commissioning status, the alignment procedures, and initial alignment results during the initial commissioning phase of the optical system of the prototype SCT.
[3]  oai:arXiv.org:1909.08361  [pdf] - 1963787
Development and operations of INFN optical modules for the SCT Telescope camera proposed for the Cherenkov Telescope Array Observatory
Comments: 8 pages, proceeding ICRC
Submitted: 2019-09-18
The Schwarzschild-Couder Telescope (SCT) is a proposal for the Medium Size Telescopes of the Cherenkov Telescope Array. Its concept is based on a two-mirror optical system designed to improve the telescope field of view and image resolution with respect to the single mirror Davies-Cotton solution. The SCT camera is planned to be instrumented with 177 photodetection modules, each composed of 64 Silicon Photomultiplier (SiPM) pixels. The third generation of $6 x 6~mm^2$ high density NUV SiPMs (NUV-HD3) produced by Fondazione Bruno Kessler (FBK) in collaboration with INFN has been used to equip optical units to be integrated on the upgrade of the camera of the SCT prototype (pSCT). Each optical unit is composed of an array of 16 NUV-HD3 SiPMs coupled with the front-end electronics, which is designed for full-waveform nanosecond readout and digitization using the TARGET-7 ASIC. Several optical units have been assembled and tested in the laboratories of INFN and have been integrated on the camera of the pSCT telescope, that is currently operating at the Fred Lawrence Whipple Observatory. In this contribution we report on the development, assembly and calibration of the optical units that are currently taking data on the pSCT camera.
[4]  oai:arXiv.org:1909.01682  [pdf] - 1955438
Front-end electronics for the GAPS tracker
Comments: 7 pages, 3 figures 36th International Cosmic Ray Conference -ICRC2019- July 24th - August 1st
Submitted: 2019-09-04
The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon-borne mission to indirectly search for dark matter through sensitive observation of cosmic antiparticles. The first flight is planned for late 2021. GAPS is the first experiment optimized specifically for detection of low-energy (< 0.25 GeV/n) antideuterons, which are recognized as distinctive signals from dark matter annihilation or decay in the Galactic halo. To achieve high sensitivity to cosmic antinuclei in this low-energy range, GAPS uses a novel particle identification method based on exotic atom capture and decay. The GAPS instrument consists of ten planes of 1440 10 cm-diameter, 2.5 mm-thick, 8-strip lithium drifted silicon (Si(Li)) detectors, which constitutes the tracker, surrounded by a plastic scintillator time-of-flight system. A new fabrication technique has been developed to satisfy the stringent requirements of the mission. In this contribution, we describe the front-end electronics of the tracker of GAPS. The system is composed of front-end ASICs and power supplies. The ASICs provide readout and digitization of the signal (with an 11-bit ADC) in a wide dynamic range (10 keV - 100 MeV). Every ASIC has 32 channels and performs the readout for 4 detectors, for a total amount of 11520 channels. The ASIC analog front-end is based on a dynamic compression technique to handle a large range of signal amplitudes and features a low noise performance, achieving the required 4 keV resolution at low energies. The power system supplies both bias voltages for the Si(Li) detectors and low voltages for the electronics. 36th
[5]  oai:arXiv.org:1612.08605  [pdf] - 1533876
Development of a SiPM Cherenkov camera demonstrator for the CTA observatory telescopes
Comments: XXV ECRS 2016 Proceedings - eConf C16-09-04.3
Submitted: 2016-12-24
The Cherenkov Telescope Array (CTA) Consortium is developing the new generation of ground observatories for the detection of ultra-high energy gamma-rays. The Italian Institute of Nuclear Physics (INFN) is participating to the R&D of a possible solution for the Cherenkov photon cameras based on Silicon Photomultiplier (SiPM) detectors sensitive to Near Ultraviolet (NUV) energies. The latest NUV-HD SiPM technology achieved by the collaboration of INFN with Fondazione Bruno Kessler (FBK) is based on $30\mu\mbox{m}\times30\mu\mbox{m}$ micro-cell sensors arranged in a $6\times6\;\mbox{mm}^2$ area. Single SiPMs produced by FBK have been tested and their performances have been found to be suitable to equip the CTA cameras. Currently, INFN is developing the concept, mechanics and electronics for prototype modules made of 64 NUV-HD SiPMs intended to equip a possible update of the CTA Prototype Schwarzschild-Couder Telescope (pSCT) telescope. The performances of NUV-HD SiPMs and the design and tests of multi-SiPM modules are reviewed in this contribution.