Normalized to: Blondel, C.
[1]
oai:arXiv.org:1512.00305 [pdf] - 1449892
Fast-neutron induced background in LaBr3:Ce detectors
Kiener, J.;
Tatischeff, V.;
Deloncle, I.;
de Séréville, N.;
Laurent, P.;
Blondel, C.;
Chabot, M.;
Chipaux, R.;
Coc, A.;
Dubos, S.;
Gostojic, A.;
Goutev, N.;
Hamadache, C.;
Hammache, F.;
Horeau, B.;
Limousin, O.;
Ouichaoui, S.;
Prévot, G.;
Rodríguez-Gasén, R.;
Yavahchova, M. S.
Submitted: 2015-12-01
The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce
crystal to incident neutrons has been measured in the energy range En = 2-12
MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6
MeV with pulsed proton beams. Using the time-of-flight information between
target and detector, energy spectra of the LaBr3:Ce detector resulting from
fast neutron interactions have been obtained at 4 different neutron energies.
Neutron-induced gamma rays emitted by the LaBr3:Ce crystal were also measured
in a nearby Ge detector at the lowest proton beam energy. In addition, we
obtained data for neutron irradiation of a large-volume high-purity Ge detector
and of a NE-213 liquid scintillator detector, both serving as monitor detectors
in the experiment. Monte-Carlo type simulations for neutron interactions in the
liquid scintillator, the Ge and LaBr3:Ce crystals have been performed and
compared with measured data. Good agreement being obtained with the data, we
present the results of simulations to predict the response of LaBr3:Ce
detectors for a range of crystal sizes to neutron irradiation in the energy
range En = 0.5-10 MeV
[2]
oai:arXiv.org:1505.00976 [pdf] - 988459
Hard X-ray polarimetry with Caliste, a high performance CdTe based
imaging spectrometer
Antier, S.;
Ferrando, P.;
Limousin, O.;
Caroli, E.;
da Silva, R. M. Curado;
Blondel, C.;
Chipaux, R.;
Honkimaki, V.;
Horeau, B.;
Laurent, P.;
Maia, J. M.;
Meuris, A.;
Del Sordo, S.;
Stephen, J. B.
Submitted: 2015-05-05
Since the initial exploration of soft gamma-ray sky in the 60's, high-energy
celestial sources have been mainly characterized through imaging, spectroscopy
and timing analysis. Despite tremendous progress in the field, the radiation
mechanisms at work in sources such as neutrons stars and black holes are still
unclear. The polarization state of the radiation is an observational parameter
which brings key additional information about the physical process. This is why
most of the projects for the next generation of space missions covering the
tens of keV to the MeV region require a polarization measurement capability. A
key element enabling this capability is a detector system allowing the
identification and characterization of Compton interactions as they are the
main process at play. The hard X-ray imaging spectrometer module, developed in
CEA with the generic name of Caliste module, is such a detector. In this paper,
we present experimental results for two types of Caliste-256 modules, one based
on a CdTe crystal, the other one on a CdZnTe crystal, which have been exposed
to linearly polarized beams at the European Synchrotron Radiation Facility.
These results, obtained at 200-300 keV, demonstrate their capability to give an
accurate determination of the polarization parameters (polarization angle and
fraction) of the incoming beam. Applying a selection to our data set,
equivalent to select 90 degrees Compton scattered interactions in the detector
plane, we find a modulation factor Q of 0.78. The polarization angle and
fraction are derived with accuracies of approximately 1 degree and 5%. The
modulation factor remains larger than 0.4 when essentially no selection is made
at all on the data. These results prove that the Caliste-256 modules have
performances allowing them to be excellent candidates as detectors with
polarimetric capabilities, in particular for future space missions.
[3]
oai:arXiv.org:astro-ph/0310362 [pdf] - 60025
ISGRI: the INTEGRAL Soft Gamma-Ray Imager
Lebrun, F.;
Leray, J. -P.;
Lavocat, P.;
Cretolle, J.;
Arques, M.;
Blondel, C.;
Bonnin, C.;
Bouere, A.;
Cara, C.;
Chaleil, T.;
Daly, F.;
Desages, F.;
Dzitko, H.;
Horeau, B.;
Laurent, P.;
Limousin, O.;
Mathy, F.;
Mauguen, V.;
Meignier, F.;
Molinie, F.;
Poindron, E.;
Rouger, M.;
Sauvageon, A.;
Tourette, T.
Submitted: 2003-10-14
For the first time in the history of high energy astronomy, a large CdTe
gamma-ray camera is operating in space. ISGRI is the low-energy camera of the
IBIS telescope on board the INTEGRAL satellite. This paper details its design
and its in-flight behavior and performances. Having a sensitive area of 2621
cm$^2$ with a spatial resolution of 4.6 mm, a low threshold around 12 keV and
an energy resolution of $\sim$ 8% at 60 keV, ISGRI shows absolutely no signs of
degradation after 9 months in orbit. All aspects of its in-flight behavior and
scientific performance are fully nominal, and in particular the observed
background level confirms the expected sensitivity of 1 milliCrab for a 10$^6$s
observation.
[4]
oai:arXiv.org:astro-ph/0310096 [pdf] - 363040
In flight calibration of the ISGRI camera
Terrier, Regis;
Lebrun, F.;
Bazzano, A.;
Belanger, G.;
Bird, A. J.;
Blondel, C.;
David, P.;
Goldoni, P.;
Goldwurm, A.;
Gros, A.;
Laurent, P.;
Malaguti, G.;
Sauvageon, A.;
Segreto, A.;
Ubertini, P.
Submitted: 2003-10-03
ISGRI, the IBIS low energy camera (15 keV - 1 MeV) on board INTEGRAL, is the
first large CdTe gamma-ray imager in orbit. We present here an overview of the
ISGRI in-flight calibrations performed during the first months after launch. We
discuss the stability of the camera as well as the CdTe pixels response under
cosmic radiation. The energy calibra tions were done using lead and tungsten
fluorescence lines and the $\mathrm{^{22}Na}$ calibration unit. Thermal effects
and charge correction algorithm are discussed, and the resulting energy
resolution is presented. The ISGRI background spatial and spectral
non-uniformity is also described, and some image correction results are
presented.