sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Blind, Nicolas

Normalized to: Blind, N.

31 article(s) in total. 295 co-authors, from 1 to 17 common article(s). Median position in authors list is 5,0.

[1]  oai:arXiv.org:1903.11903  [pdf] - 1857830
First direct detection of an exoplanet by optical interferometry; Astrometry and K-band spectroscopy of HR8799 e
Comments: published in A&A
Submitted: 2019-03-28
To date, infrared interferometry at best achieved contrast ratios of a few times $10^{-4}$ on bright targets. GRAVITY, with its dual-field mode, is now capable of high contrast observations, enabling the direct observation of exoplanets. We demonstrate the technique on HR8799, a young planetary system composed of four known giant exoplanets. We used the GRAVITY fringe tracker to lock the fringes on the central star, and integrated off-axis on the HR8799e planet situated at 390 mas from the star. Data reduction included post-processing to remove the flux leaking from the central star and to extract the coherent flux of the planet. The inferred K band spectrum of the planet has a spectral resolution of 500. We also derive the astrometric position of the planet relative to the star with a precision on the order of 100$\,\mu$as. The GRAVITY astrometric measurement disfavors perfectly coplanar stable orbital solutions. A small adjustment of a few degrees to the orbital inclination of HR 8799 e can resolve the tension, implying that the orbits are close to, but not strictly coplanar. The spectrum, with a signal-to-noise ratio of $\approx 5$ per spectral channel, is compatible with a late-type L brown dwarf. Using Exo-REM synthetic spectra, we derive a temperature of $1150\pm50$\,K and a surface gravity of $10^{4.3\pm0.3}\,$cm/s$^{2}$. This corresponds to a radius of $1.17^{+0.13}_{-0.11}\,R_{\rm Jup}$ and a mass of $10^{+7}_{-4}\,M_{\rm Jup}$, which is an independent confirmation of mass estimates from evolutionary models. Our results demonstrate the power of interferometry for the direct detection and spectroscopic study of exoplanets at close angular separations from their stars.
[2]  oai:arXiv.org:1808.02141  [pdf] - 1729246
GRAVITY chromatic imaging of Eta Car's core
GRAVITY Collaboration; Sanchez-Bermudez, J.; Weigelt, G.; Bestenlehner, J. M.; Kervella, P.; Brandner, W.; Henning, Th.; Müller, A.; Perrin, G.; Pott, J. -U.; Schöller, M.; van Boekel, R.; Abuter, R.; Accardo, M.; Amorim, A.; Anugu, N.; Ávila, G.; Benisty, M.; Berger, J. P.; Blind, N.; Bonnet, H.; Bourget, P.; Brast, R.; Buron, A.; Cantalloube, F.; Garatti, A. Caratti o; Cassaing, F.; Chapron, F.; Choquet, E.; Clénet, Y.; Collin, C.; Foresto, V. Coudé du; de Wit, W.; de Zeeuw, T.; Deen, C.; Delplancke-Ströbele, F.; Dembet, R.; Derie, F.; Dexter, J.; Duvert, G.; Ebert, M.; Eckart, A.; Eisenhauer, F.; Esselborn, M.; Fédou, P.; Garcia, P. J. V.; Dabo, C. E. Garcia; Lopez, R. Garcia; Gao, F.; Gendron, E.; Genzel, R.; Gillessen, S.; Haubois, X.; Haug, M.; Haussmann, F.; Hippler, S.; Horrobin, M.; Huber, A.; Hubert, Z.; Hubin, N.; Hummel, C. A.; Jakob, G.; Jochum, L.; Jocou, L.; Karl, M.; Kaufer, A.; Kellner, S.; Kendrew, S.; Kern, L.; Kiekebusch, M.; Klein, R.; Kolb, J.; Kulas, M.; Lacour, S.; Lapeyrère, V.; Lazareff, B.; Bouquin, J. -B. Le; Léna, P.; Lenzen, R.; Levêque, S.; Lippa, M.; Magnard, Y.; Mehrgan, L.; Mellein, M.; Mérand, A.; Moreno-Ventas, J.; Moulin, T.; Müller, E.; Müller, F.; Neumann, U.; Oberti, S.; Ott, T.; Pallanca, L.; Panduro, J.; Pasquini, L.; Paumard, T.; Percheron, I.; Perraut, K.; Petrucci, P. -O.; Pflüger, A.; Pfuhl, O.; Duc, T. P.; Plewa, P. M.; Popovic, D.; Rabien, S.; Ramirez, A.; Ramos, J.; Rau, C.; Riquelme, M.; Rodríguez-Coira, G.; Rohloff, R. -R.; Rosales, A.; Rousset, G.; Scheithauer, S.; Schuhler, N.; Spyromilio, J.; Straub, O.; Straubmeier, C.; Sturm, E.; Suarez, M.; Tristram, K. R. W.; Ventura, N.; Vincent, F.; Waisberg, I.; Wank, I.; Widmann, F.; Wieprecht, E.; Wiest, M.; Wiezorrek, E.; Wittkowski, M.; Woillez, J.; Wolff, B.; Yazici, S.; Ziegler, D.; Zins, G.
Comments: 32 pages, 27 figures (14 in the main body, 13 in the appendices), accepted for publication in AA
Submitted: 2018-08-06
Eta Car is one of the most intriguing luminous blue variables in the Galaxy. Observations and models at different wavelengths suggest a central binary with a 5.54 yr period residing in its core. 2D and 3D radiative transfer and hydrodynamic simulations predict a primary with a dense and slow stellar wind that interacts with the faster and lower density wind of the secondary. The wind-wind collision scenario suggests that the secondary's wind penetrates the primary's wind creating a low-density cavity in it, with dense walls where the two winds interact. We aim to trace the inner ~5-50 au structure of Eta Car's wind-wind interaction, as seen through BrG and, for the first time, through the He I 2s-2p line. We have used spectro-interferometric observations with GRAVITY at the VLTI. Our modeling of the continuum allows us to estimate its FWHM angular size close to 2 mas and an elongation ratio of 1.06 +/- 0.05 over a PA = 130 +/- 20 deg. Our CMFGEN modeling helped us to confirm that the role of the secondary should be taken into account to properly reproduce the observed BrG and He I lines. Chromatic images across BrG reveal a southeast arc-like feature, possibly associated to the hot post-shocked winds flowing along the cavity wall. The images of He I 2s-2p served to constrain the 20 mas structure of the line-emitting region. The observed morphology of He I suggests that the secondary is responsible for the ionized material that produces the line profile. Both the BrG and the He I 2s-2p maps are consistent with previous hydrodynamical models of the colliding wind scenario. Future dedicated simulations together with an extensive interferometric campaign are necessary to refine our constraints on the wind and stellar parameters of the binary, which finally will help us predict the evolutionary path of Eta Car.
[3]  oai:arXiv.org:1807.09409  [pdf] - 1725096
Detection of the gravitational redshift in the orbit of the star S2 near the Galactic centre massive black hole
Comments: Accepted for publication in A&A Letters, 29 June 2018, 10 pages, 6 figures, corresponding author: F. Eisenhauer <eisenhau@mpe.mpg.de>
Submitted: 2018-07-24
The highly elliptical, 16-year-period orbit of the star S2 around the massive black hole candidate Sgr A* is a sensitive probe of the gravitational field in the Galactic centre. Near pericentre at 120 AU, ~1400 Schwarzschild radii, the star has an orbital speed of ~7650 km/s, such that the first-order effects of Special and General Relativity have now become detectable with current capabilities. Over the past 26 years, we have monitored the radial velocity and motion on the sky of S2, mainly with the SINFONI and NACO adaptive optics instruments on the ESO Very Large Telescope, and since 2016 and leading up to the pericentre approach in May 2018, with the four-telescope interferometric beam-combiner instrument GRAVITY. From data up to and including pericentre, we robustly detect the combined gravitational redshift and relativistic transverse Doppler effect for S2 of z ~ 200 km/s / c with different statistical analysis methods. When parameterising the post-Newtonian contribution from these effects by a factor f, with f = 0 and f = 1 corresponding to the Newtonian and general relativistic limits, respectively, we find from posterior fitting with different weighting schemes f = 0.90 +/- 0.09 (stat) +\- 0.15 (sys). The S2 data are inconsistent with pure Newtonian dynamics.
[4]  oai:arXiv.org:1711.00835  [pdf] - 1590655
Few-mode fibers and AO-assisted high resolution spectroscopy: coupling efficiency and modal noise mitigation
Comments: 10 pages, 5 figures. Proceeding of the AO4ELT5 conference
Submitted: 2017-11-02
NIRPS (Near Infra-Red Planet Searcher) is an AO-assisted and fiber-fed spectrograph for high precision radial velocity measurements that will operate in the YJH-bands. While using an AO system in such instrument is generally considered to feed a single-mode fiber, NIRPS is following a different path by using a small multi-mode fiber (more specifically called "few-mode fiber"). This choice offers an excellent trade-off by allowing to design a compact cryogenic spectrograph, while maintaining a high coupling efficiency under bad seeing conditions and for faint stars. The main drawback resides in a much more important modal-noise, a problem that has to be tackled for allowing 1m/s precision radial velocity measurements. We study the impact of using an AO system to couple light into few-mode fibers. We focus on two aspects: the coupling efficiency into few-mode fibers and the question of modal noise and scrambling. We show first that NIRPS can reach coupling >= 50% up to magnitude I=12, and offer a gain of 1-2 magnitudes over a single-mode solution. We finally show that the best strategy to mitigate modal noise with the AO system is among the simplest: a continuous tip-tilt scanning of the fiber core.
[5]  oai:arXiv.org:1707.01669  [pdf] - 1585582
Spectrographs for astrophotonics
Comments: 29 pages, 17 figures; accepted for publication in Optics Express, feature issue "Recent Advances in Astrophotonics"
Submitted: 2017-07-06
The next generation of Extremely Large Telescopes (ELT), with diameters up to 39 meters, is planned to begin operation in the next decade and promises new challenges in the development of instruments since the instrument size increases in proportion to the telescope diameter D, and the cost as D2 or faster. The growing field of astrophotonics (the use of photonic technologies in astronomy) could solve this problem by allowing mass production of fully integrated and robust instruments combining various optical functions, with the potential to reduce the size, complexity and cost of instruments. Astrophotonics allows for a broad range of new optical functions, with applications ranging from sky background filtering, high spatial and spectral resolution imaging and spectroscopy. In this paper, we want to provide astronomers with valuable keys to understand how photonics solutions can be implemented (or not) according to the foreseen applications. The paper introduces first key concepts linked to the characteristics of photonics technologies, placed in the framework of astronomy and spectroscopy. We then describe a series of merit criteria that help us determine the potential of a given micro-spectrograph technology for astronomy applications, and then take an inventory of the recent developments in integrated micro-spectrographs with potential for astronomy. We finally compare their performance, to finally draw a map of typical science requirements and pin the identified integrated technologies on it. We finally emphasize the necessary developments that must support micro-spectrograph in the coming years.
[6]  oai:arXiv.org:1705.02359  [pdf] - 1583169
Accretion-ejection morphology of the microquasar SS433 resolved at sub-au scale
Comments: Submitted for publication in A&A Letters, 4 pages + appendix, 4 figures. Comments welcome
Submitted: 2017-05-05
We present the first optical observation at sub-milliarcsecond (mas) scale of the microquasar SS 433 obtained with the GRAVITY instrument on the VLT interferometer. The 3.5 hour exposure reveals a rich K-band spectrum dominated by hydrogen Br$\gamma\ $ and \ion{He}{i} lines, as well as (red-shifted) emission lines coming from the jets. The K-band continuum emitting region is dominated by a marginally resolved point source ($<$ 1 mas) embedded inside a diffuse background accounting for 10\% of the total flux. The jet line positions agree well with the ones expected from the jet kinematic model, an interpretation also supported by the consistent sign (i.e. negative/positive for the receding/approaching jet component) of the phase shifts observed in the lines. The significant visibility drop across the jet lines, together with the small and nearly identical phases for all baselines, point toward a jet that is offset by less than 0.5 mas from the continuum source and resolved in the direction of propagation, with a typical size of 2 mas. The jet position angle of $\sim$80$^{\circ}$ is consistent with the expected one at the observation date. Jet emission so close to the central binary system would suggest that line locking, if relevant to explain the amplitude and stability of the 0.26c jet velocity, operates on elements heavier than hydrogen. The Br$\gamma\ $ profile is broad and double peaked. It is better resolved than the continuum and the change of the phase signal sign across the line on all baselines suggests an East-West oriented geometry alike the jet direction and supporting a (polar) disk wind origin.
[7]  oai:arXiv.org:1705.02351  [pdf] - 1996654
Sub-milliarcsecond Optical Interferometry of the HMXB BP Cru with VLTI/GRAVITY
Comments: Submitted to ApJ, 22 pages, 17 figures
Submitted: 2017-05-05
We observe the HMXB BP Cru using interferometry in the near-infrared K band with VLTI/GRAVITY. Continuum visibilities are at most partially resolved, consistent with the predicted size of the hypergiant. Differential visibility amplitude ($\Delta |V| \sim 5\%$) and phase ($\Delta \phi \sim 2 \deg$) signatures are observed across the HeI $2.059 \mu$m and Br$\gamma$ lines, the latter seen strongly in emission, unusual for the donor star's spectral type. For a baseline $B \sim 100$m, the differential phase RMS $\sim 0.2 \deg$ corresponds to an astrometric precision of $\sim 2 \mu$as. A model-independent analysis in the marginally resolved limit of interferometry reveals asymmetric and extended emission with a strong wavelength dependence. We propose geometric models based on an extended and distorted wind and/or a high density gas stream, which has long been predicted to be present in this system. The observations show that optical interferometry is now able to resolve HMXBs at the spatial scale at which accretion takes place, and therefore probe the effects of the gravitational and radiation fields of the compact object on its environment.
[8]  oai:arXiv.org:1705.02345  [pdf] - 1583163
First Light for GRAVITY: Phase Referencing Optical Interferometry for the Very Large Telescope Interferometer
GRAVITY Collaboration; Abuter, R.; Accardo, M.; Amorim, A.; Anugu, N.; Ávila, G.; Azouaoui, N.; Benisty, M.; Berger, J. P.; Blind, N.; Bonnet, H.; Bourget, P.; Brandner, W.; Brast, R.; Buron, A.; Burtscher, L.; Cassaing, F.; Chapron, F.; Choquet, É.; Clénet, Y.; Collin, C.; Foresto, V. Coudé du; de Wit, W.; de Zeeuw, P. T.; Deen, C.; Delplancke-Ströbele, F.; Dembet, R.; Derie, F.; Dexter, J.; Duvert, G.; Ebert, M.; Eckart, A.; Eisenhauer, F.; Esselborn, M.; Fédou, P.; Finger, G.; Garcia, P.; Dabo, C. E. Garcia; Lopez, R. Garcia; Gendron, E.; Genzel, R.; Gillessen, S.; Gonte, F.; Gordo, P.; Grould, M.; Grözinger, U.; Guieu, S.; Haguenauer, P.; Hans, O.; Haubois, X.; Haug, M.; Haussmann, F.; Henning, Th.; Hippler, S.; Horrobin, M.; Huber, A.; Hubert, Z.; Hubin, N.; Hummel, C. A.; Jakob, G.; Janssen, A.; Jochum, L.; Jocou, L.; Kaufer, A.; Kellner, S.; Kern, L.; Kervella, P.; Kiekebusch, M.; Klein, R.; Kok, Y.; Kolb, J.; Kulas, M.; Lacour, S.; Lapeyrère, V.; Lazareff, B.; Bouquin, J. -B. Le; Lèna, P.; Lenzen, R.; Lévêque, S.; Lippa, M.; Magnard, Y.; Mehrgan, L.; Mellein, M.; Mérand, A.; Moreno-Ventas, J.; Moulin, T.; Müller, E.; Müller, F.; Neumann, U.; Oberti, S.; Ott, T.; Pallanca, L.; Panduro, J.; Pasquini, L.; Paumard, T.; Percheron, I.; Perraut, K.; Perrin, G.; Pflüger, A.; Pfuhl, O.; Duc, T. Phan; Plewa, P. M.; Popovic, D.; Rabien, S.; Ramírez, A.; Ramos, J.; Rau, C.; Riquelme, M.; Rohloff, R. -R.; Rousset, G.; Sanchez-Bermudez, J.; Scheithauer, S.; Schöller, M.; Schuhler, N.; Spyromilio, J.; Straubmeier, C.; Sturm, E.; Suarez, M.; Tristram, K. R. W.; Ventura, N.; Vincent, F.; Waisberg, I.; Wank, I.; Weber, J.; Wieprecht, E.; Wiest, M.; Wiezorrek, E.; Wittkowski, M.; Woillez, J.; Wolff, B.; Yazici, S.; Ziegler, D.; Zins, G.
Comments: Accepted for publication in A&A, 23 pages, 23 figures, corresponding author: F. Eisenhauer <eisenhau@mpe.mpg.de>
Submitted: 2017-05-05
GRAVITY is a new instrument to coherently combine the light of the European Southern Observatory Very Large Telescope Interferometer to form a telescope with an equivalent 130 m diameter angular resolution and a collecting area of 200 m$^2$. The instrument comprises fiber fed integrated optics beam combination, high resolution spectroscopy, built-in beam analysis and control, near-infrared wavefront sensing, phase-tracking, dual beam operation and laser metrology [...]. This article gives an overview of GRAVITY and reports on the performance and the first astronomical observations during commissioning in 2015/16. We demonstrate phase tracking on stars as faint as m$_K$ ~ 10 mag, phase-referenced interferometry of objects fainter than m$_K$ ~ 15 mag with a limiting magnitude of m$_K$ ~ 17 mag, minute long coherent integrations, a visibility accuracy of better than 0.25 %, and spectro-differential phase and closure phase accuracy better than 0.5{\deg}, corresponding to a differential astrometric precision of better than 10 microarcseconds ({\mu}as). The dual-beam astrometry, measuring the phase difference of two objects with laser metrology, is still under commissioning. First observations show residuals as low as 50 {\mu}as when following objects over several months. We illustrate the instrument performance with the observations of archetypical objects for the different instrument modes. Examples include the Galactic Center supermassive black hole and its fast orbiting star S2 for phase referenced dual beam observations and infrared wavefront sensing, the High Mass X-Ray Binary BP Cru and the Active Galactic Nucleus of PDS 456 for few {\mu}as spectro-differential astrometry, the T Tauri star S CrA for a spectro-differential visibility analysis, {\xi} Tel and 24 Cap for high accuracy visibility observations, and {\eta} Car for interferometric imaging with GRAVITY.
[9]  oai:arXiv.org:1703.02395  [pdf] - 1550532
Science cases for a visible interferometer
Comments: White Paper prospective. This book is dedicated to the memory of our colleague Olivier Chesneau who passed away at the age of 41. v2 includes some corrections to text
Submitted: 2017-03-07, last modified: 2017-03-21
High spatial resolution is the key for the understanding various astrophysical phenomena. But even with the future E-ELT, single dish instruments are limited to a spatial resolution of about 4 mas in the visible. For the closest objects within our Galaxy most of the stellar photosphere remains smaller than 1 mas. With the success of long baseline interferometry these limitations were soom overcome. Today low and high resolution interferometric instruments on the VLTI and CHARA offer an immense range of astrophysical studies. Combining more telescopes and moving to visible wavelengths broadens the science cases even more. With the idea of developing strong science cases for a future visible interferometer, we organized a science group around the following topics: pre-main sequence and main sequence stars, fundamental parameters, asteroseismology and classical pulsating stars, evolved stars, massive stars, active galactic nuclei (AGNs) and imaging techniques. A meeting was organized on the 15th and 16th of January, 2015 in Nice with the support of the Action Specific in Haute Resolution Angulaire (ASHRA), the Programme National en Physique Stellaire (PNPS), the Lagrange Laboratory and the Observatoire de la Cote d'Azur, in order to present these cases and to discuss them further for future visible interferometers. This White Paper presents the outcome of the exchanges. This book is dedicated to the memory of our colleague Olivier Chesneau who passed away at the age of 41.
[10]  oai:arXiv.org:1608.05731  [pdf] - 1531322
A near-infrared interferometric survey of debris-disc stars. V. PIONIER search for variability
Comments: A&A, in press
Submitted: 2016-08-19
Context: Extended circumstellar emission has been detected within a few 100 milli-arcsec around > 10% of nearby main sequence stars using near-infrared interferometry. Follow-up observations using other techniques, should they yield similar results or non-detections, can provide strong constraints on the origin of the emission. They can also reveal the variability of the phenomenon. Aims: We aim to demonstrate the persistence of the phenomenon over time scales of a few years and to search for variability of our previously detected excesses. Methods: Using VLTI/PIONIER in H band we have carried out multi-epoch observations of the stars for which a near-infrared excess was previously detected with the same observing technique and instrument. The detection rates and distribution of the excesses from our original survey and the follow-up observations are compared statistically. A search for variability of the excesses in our time series is carried out based on the level of the broadband excesses. Results: In 12 of 16 follow-up observations, an excess is re-detected with a significance of > 2 sigma, and in 7 of 16 follow-up observations significant excess (> 3 sigma) has been re-detected. We statistically demonstrate with very high confidence that the phenomenon persists for the majority of the systems. We also present the first detection of potential variability in two sources. Conclusions: We conclude that the phenomenon responsible for the excesses persists over time scales of a few years for the majority of the systems. However, we also find that variability intrinsic to a target can cause it to have no significant excess at the time of a specific observation.
[11]  oai:arXiv.org:1608.04888  [pdf] - 1458639
The metrology system of the VLTI instrument GRAVITY
Comments: 9 pages, 5 figures
Submitted: 2016-08-17
The VLTI instrument GRAVITY combines the beams from four telescopes and provides phase-referenced imaging as well as precision-astrometry of order 10 microarcseconds by observing two celestial objects in dual-field mode. Their angular separation can be determined from their differential OPD (dOPD) when the internal dOPDs in the interferometer are known. Here, we present the general overview of the novel metrology system which performs these measurements. The metrology consists of a three-beam laser system and a homodyne detection scheme for three-beam interference using phase-shifting interferometry in combination with lock-in amplifiers. Via this approach the metrology system measures dOPDs on a nanometer-level.
[12]  oai:arXiv.org:1608.01124  [pdf] - 1521282
Adaptive optics for high resolution spectroscopy: A direct application with the future NIRPS spectrograph
Comments: 9 pages, 5 figures, Proceeding 9909-142 of the SPIE Astronomical Telescopes + Instrumentation 2016
Submitted: 2016-08-03
Radial velocity instruments require high spectral resolution and extreme thermo-mecanical stability, even more difficult to achieve in near-infra red (NIR) where the spectrograph has to be cooled down. For a seeing-limited spectrograph, the price of high spectral resolution is an increased instrument volume, proportional to the diameter of the primary mirror. A way to control the size, cost, and stability of radial velocity spectrographs is to reduce the beam optical etendue thanks to an Adaptive Optics (AO) system. While AO has revolutionized the field of high angular resolution and high contrast imaging during the last 20 years, it has not yet been (successfully) used as a way to control spectrographs size, especially in the field of radial velocities. In this work we present the AO module of the future NIRPS spectrograph for the ESO 3.6 m telescope, that will be feed with multi-mode fibers. We converge to an AO system using a Shack-Hartmann wavefront sensor with 14x14 subapertures, able to feed 50% of the energy into a 0.4" fiber in the range of 0.98 to 1.8 $\mu m$ for M-type stars as faint as I=12.
[13]  oai:arXiv.org:1503.07303  [pdf] - 970999
GRAVITY: the VLTI 4-beam combiner for narrow-angle astrometry and interferometric imaging
Comments: 8 pages, 3 figures. Proceeding of the conference "Fiber optics in astronomy IV". The follwoing authors made significant contribution regarding the work on fibers reported in this paper (ordered by institute and alphabetical order): IPAG: L. Jocou, K. Perraut; LESIA: R. Dembet, P. Fedou, S. Lacour, G. Perrin; MPE: N. Blind, F. Eisenhauer, S. Gillessen,, Y. Kok, M. Lippa
Submitted: 2015-03-25
GRAVITY is the second generation Very Large Telescope Interferometer instrument for precision narrow-angle astrometry and interferometric imaging in the Near Infra-Red (NIR). It shall provide precision astrometry of order 10 microarcseconds, and imaging capability at a few milliarcsecond resolution, and hence will revolutionise dynamical measurements of celestial objects. GRAVITY is currently in the last stages of its integration and tests in Garching at MPE, and will be delivered to the VLT Interferometer (VLTI) in 2015. We present here the instrument, with a particular focus on the components making use of fibres: integrated optics beam combiners, polarisation rotators, fibre differential delay lines, and the metrology.
[14]  oai:arXiv.org:1501.05822  [pdf] - 925683
The GRAVITY instrument software / High-level software
Comments: 8 pages, 7 figures, published in Proc. SPIE 9146, Optical and Infrared Interferometry IV, 91462B
Submitted: 2015-01-23
GRAVITY is the four-beam, near- infrared, AO-assisted, fringe tracking, astrometric and imaging instrument for the Very Large Telescope Interferometer (VLTI). It is requiring the development of one of the most complex instrument software systems ever built for an ESO instrument. Apart from its many interfaces and interdependencies, one of the most challenging aspects is the overall performance and stability of this complex system. The three infrared detectors and the fast reflective memory network (RMN) recorder contribute a total data rate of up to 20 MiB/s accumulating to a maximum of 250 GiB of data per night. The detectors, the two instrument Local Control Units (LCUs) as well as the five LCUs running applications under TAC (Tools for Advanced Control) architecture, are interconnected with fast Ethernet, RMN fibers and dedicated fiber connections as well as signals for the time synchronization. Here we give a simplified overview of all subsystems of GRAVITY and their interfaces and discuss two examples of high-level applications during observations: the acquisition procedure and the gathering and merging of data to the final FITS file.
[15]  oai:arXiv.org:1501.04738  [pdf] - 923534
The GRAVITY metrology system: narrow-angle astrometry via phase-shifting interferometry
Comments: 11 pages, 7 figures
Submitted: 2015-01-20
The VLTI instrument GRAVITY will provide very powerful astrometry by combining the light from four telescopes for two objects simultaneously. It will measure the angular separation between the two astronomical objects to a precision of 10 microarcseconds. This corresponds to a differential optical path difference (dOPD) between the targets of few nanometers and the paths within the interferometer have to be maintained stable to that level. For this purpose, the novel metrology system of GRAVITY will monitor the internal dOPDs by means of phase-shifting interferometry. We present the four-step phase-shifting concept of the metrology with emphasis on the method used for calibrating the phase shifts. The latter is based on a phase-step insensitive algorithm which unambiguously extracts phases in contrast to other methods that are strongly limited by non-linearities of the phase-shifting device. The main constraint of this algorithm is to introduce a robust ellipse fitting routine. Via this approach we are able to measure phase shifts in the laboratory with a typical accuracy of lambda/2000 or 1 nanometer of the metrology wavelength.
[16]  oai:arXiv.org:1412.1696  [pdf] - 904702
The fiber coupler and beam stabilization system of the GRAVITY interferometer
Comments: 14 pages, 13 figures. Proceedings of the SPIE 9146 "Optical and Infrared Interferometry IV"
Submitted: 2014-12-04
We present the installed and fully operational beam stabilization and fiber injection subsystem feeding the 2nd generation VLTI instrument GRAVITY. The interferometer GRAVITY requires an unprecedented stability of the VLTI optical train to achieve micro-arcsecond astrometry. For this purpose, GRAVITY contains four fiber coupler units, one per telescope. Each unit is equipped with actuators to stabilize the telescope beam in terms of tilt and lateral pupil displacement, to rotate the field, to adjust the polarization and to compensate atmospheric piston. A special roof-prism offers the possibility of on-axis as well as off-axis fringe tracking without changing the optical train. We describe the assembly, integration and alignment and the resulting optical quality and performance of the individual units. Finally, we present the closed-loop performance of the tip-tilt and pupil tracking achieved with the final systems in the lab.
[17]  oai:arXiv.org:1409.6143  [pdf] - 892035
A near-infrared interferometric survey of debris-disc stars. IV. An unbiased sample of 92 southern stars observed in H-band with VLTI/PIONIER
Comments: 20 pages, 16 figures, 4 tables, updated references and minor changes to the text, accepted for publication in A&A
Submitted: 2014-09-22, last modified: 2014-09-25
Context. Detecting and characterizing circumstellar dust is a way to study the architecture and evolution of planetary systems. Cold dust in debris disks only traces the outer regions. Warm and hot exozodiacal dust needs to be studied in order to trace regions close to the habitable zone. Aims. We aim to determine the prevalence and to constrain the properties of hot exozodiacal dust around nearby main-sequence stars. Methods. We search a magnitude limited (H < 5) sample of 92 stars for bright exozodiacal dust using our VLTI visitor instrument PIONIER in the H-band. We derive statistics of the detection rate with respect to parameters such as the stellar spectral type and age or the presence of a debris disk in the outer regions of the systems. We derive more robust statistics by combining our sample with the results from our CHARA/FLUOR survey in the K-band. In addition, our spectrally dispersed data allows us to put constraints on the emission mechanism and the dust properties in the detected systems. Results. We find an over-all detection rate of bright exozodiacal dust in the H-band of 11% (9 out of 85 targets) and three tentative detections. The detection rate decreases from early type to late type stars and increases with the age of the host star. We do not confirm the tentative correlation between the presence of cold and hot dust found in our earlier analysis of the FLUOR sample alone. Our spectrally dispersed data suggest that either the dust is extremely hot or the emission is dominated by the scattered light in most cases. The implications of our results for the target selection of future terrestrial planet finding missions using direct imaging are discussed.
[18]  oai:arXiv.org:1409.6105  [pdf] - 892034
Searching for faint companions with VLTI/PIONIER. II. 92 main sequence stars from the Exozodi survey
Comments: Accepted for publication in A&A
Submitted: 2014-09-22
The Exozodi survey aims to determine the occurrence rate of bright exozodiacal discs around nearby main sequence stars using infrared interferometry. Although the Exozodi survey targets have been carefully selected to avoid the presence of binary stars, the results of this survey can still be biased by the presence of unidentified stellar companions. Using the PIONIER data set collected within the Exozodi survey, we aim to search for the signature of point-like companions around the Exozodi target stars. We use both the closure phases and squared visibilities collected by PIONIER to search for companions within the ~100 mas interferometric field of view. The presence of a companion is assessed by computing the goodness of fit to the data for a series of binary models with various separations and contrasts. Five stellar companions are resolved for the first time around five A-type stars: HD 4150, HD 16555, HD 29388, HD 202730, and HD 224392 (although the companion to HD 16555 was independently resolved by speckle interferometry while we were carrying out the survey). In the most likely case of main sequence companions, their spectral types range from A5V to K4V. Three of these stars were already suspected to be binaries from Hipparcos astrometric measurements, although no information was available on the companions themselves so far. In addition to debiasing the statistics of the Exozodi survey, these results can also be used to revise the fraction of visual binaries among A-type stars, suggesting that an extra ~13% A-type stars are visual binaries in addition to the ones detected in previous direct imaging surveys. We estimate that about half the population of nearby A-type stars could be resolved as visual binaries using a combination of state-of-the-art interferometry and single-aperture imaging, and we suggest that a significant fraction of these binaries remains undetected to date.
[19]  oai:arXiv.org:1408.1217  [pdf] - 861951
Astrophotonic micro-spectrographs in the era of ELTs
Comments: 9 pages. 2 figures. Proceeding of SPIE 9147 "Ground-based and Airborne Instrumentation for Astronomy V"
Submitted: 2014-08-06
The next generation of Extremely Large Telescopes (ELT), with diameters up to 39 meters, will start opera- tion in the next decade and promises new challenges in the development of instruments. The growing field of astrophotonics (the use of photonic technologies in astronomy) can partly solve this problem by allowing mass production of fully integrated and robust instruments combining various optical functions, with the potential to reduce the size, complexity and cost of instruments. In this paper, we focus on developments in integrated micro-spectrographs and their potential for ELTs. We take an inventory of the identified technologies currently in development, and compare the performance of the different concepts. We show that in the current context of single-mode instruments, integrated spectrographs making use of, e.g., a photonic lantern can be a solution to reach the desired performance. However, in the longer term, there is a clear need to develop multimode devices to improve overall the throughput and sensitivity, while decreasing the instrument complexity.
[20]  oai:arXiv.org:1407.6669  [pdf] - 861906
The GRAVITY metrology system: modeling a metrology in optical fibers
Comments: 20 pages, 19 figures. Proceeding of SPIE 9146 "Optical and Infrared Interferometry IV"
Submitted: 2014-07-24
GRAVITY is the second generation VLT Interferometer (VLTI) instrument for high-precision narrow-angle astrometry and phase-referenced interferometric imaging. The laser metrology system of GRAVITY is at the heart of its astrometric mode, which must measure the distance of 2 stars with a precision of 10 micro-arcseconds. This means the metrology has to measure the optical path difference between the two beam combiners of GRAVITY to a level of 5 nm. The metrology design presents some non-common paths that have consequently to be stable at a level of 1 nm. Otherwise they would impact the performance of GRAVITY. The various tests we made in the past on the prototype give us hints on the components responsible for this error, and on their respective contribution to the total error. It is however difficult to assess their exact origin from only OPD measurements, and therefore, to propose a solution to this problem. In this paper, we present the results of a semi-empirical modeling of the fibered metrology system, relying on theoretical basis, as well as on characterisations of key components. The modeling of the metrology system regarding various effects, e.g., temperature, waveguide heating or mechanical stress, will help us to understand how the metrology behave. The goals of this modeling are to 1) model the test set-ups and reproduce the measurements (as a validation of the modeling), 2) determine the origin of the non-common path errors, and 3) propose modifications to the current metrology design to reach the required 1nm stability.
[21]  oai:arXiv.org:1407.6660  [pdf] - 861905
GRAVITY: the Calibration Unit
Comments: 12 pages, 11 figures. Proceeding of SPIE 9146 "Optical and Infrared Interferometry IV"
Submitted: 2014-07-24
We present in this paper the design and characterisation of a new sub-system of the VLTI 2nd generation instrument GRAVITY: the Calibration Unit. The Calibration Unit provides all functions to test and calibrate the beam combiner instrument: it creates two artificial stars on four beams, and dispose of four delay lines with an internal metrology. It also includes artificial stars for the tip-tilt and pupil guiding systems, as well as four metrology pick-up diodes, for tests and calibration of the corresponding sub-systems. The calibration unit also hosts the reference targets to align GRAVITY to the VLTI, and the safety shutters to avoid the metrology light to propagate in the VLTI-lab. We present the results of the characterisation and validtion of these differrent sub-units.
[22]  oai:arXiv.org:1405.4648  [pdf] - 825155
A PIONIER View on Mass-Transferring Red Giants
Comments: Report for the ESO Messenger June issue
Submitted: 2014-05-19
Symbiotic stars display absorption lines of a cool red giant together with emission lines of a nebula ionized by a hotter star, indicative of an active binary star system in which mass transfer is occurring. PIONIER at the VLT has been used to combine the light of four telescopes at a time to study in unprecedented detail how mass is transferred in symbiotic stars. The results of a mini-survey of symbiotic stars with PIONIER are summarised and some tentative general results about the role of Roche lobe overflow are presented.
[23]  oai:arXiv.org:1402.1798  [pdf] - 820769
Roche-lobe filling factor of mass-transferring red giants - the PIONIER view
Comments: A&A, in press
Submitted: 2014-02-07
Using the PIONIER visitor instrument that combines the light of the four Auxiliary Telescopes of ESO's Very Large Telescope Interferometer, we measure precisely the diameters of several symbiotic and related stars: HD 352, HD 190658, V1261 Ori, ER Del, FG Ser, and AG Peg. These diameters - in the range of 0.6 to 2.3 milli-arcseconds - are used to assess the filling factor of the Roche lobe of the mass-losing giants and provide indications on the nature of the ongoing mass transfer. We also provide the first spectroscopic orbit of ER Del, based on CORAVEL and HERMES/Mercator observations. The system is found to have an eccentric orbit with a period of 5.7 years. In the case of the symbiotic star FG Ser, we find that the diameter is changing by 13% over the course of 41 days, while the observations of HD 352 are indicative of an elongation. Both these stars are found to have a Roche filling factor close to 1, as is most likely the case for HD 190658 as well, while the three other stars have factors below 0.5-0.6. Our observations reveal the power of interferometry for the study of interacting binary stars - the main limitation in our conclusions being the poorly known distances of the objects.
[24]  oai:arXiv.org:1207.2285  [pdf] - 1124711
PIONIER: a status report
Comments: To appear in the proceedings of the 2012 SPIE Conference "Astronomical Telescopes and Instrumentation"
Submitted: 2012-07-10
The visitor instrument PIONIER provides VLTI with improved imaging capabilities and sensitivity. The instrument started routinely delivering scientific data in November 2010, that is less than 12 months after being approved by the ESO Science and Technical Committee. We recall the challenges that had to be tackled to design, built and commission PIONIER. We summarize the typical performances and some astrophysical results obtained so far. We conclude this paper by summarizing lessons learned.
[25]  oai:arXiv.org:1112.1514  [pdf] - 967228
An incisive look at the symbiotic star SS Leporis -- Milli-arcsecond imaging with PIONIER/VLTI
Comments: 11 pages, 5 figures, published in A&A Appendix presenting reduced data and extracted parameters Reduced data can be found on the CDS
Submitted: 2011-12-07
Context. Determining the mass transfer in a close binary system is of prime importance for understanding its evolution. SS Leporis, a symbiotic star showing the Algol paradox and presenting clear evidence of ongoing mass transfer, in which the donor has been thought to fill its Roche lobe, is a target particularly suited to this kind of study. Aims. Since previous spectroscopic and interferometric observations have not been able to fully constrain the system morphology and characteristics, we go one step further to determine its orbital parameters, for which we need new interferometric observations directly probing the inner parts of the system with a much higher number of spatial frequencies. Methods. We use data obtained at eight different epochs with the VLTI instruments AMBER and PIONIER in the H- and K-bands. We performed aperture synthesis imaging to obtain the first model-independent view of this system. We then modelled it as a binary (whose giant is spatially resolved) that is surrounded by a circumbinary disc. Results. Combining these interferometric measurements with previous radial velocities, we fully constrain the orbit of the system. We then determine the mass of each star and significantly revise the mass ratio. The M giant also appears to be almost twice smaller than previously thought. Additionally, the low spectral resolution of the data allows the flux of both stars and of the dusty disc to be determined along the H and K bands, and thereby extracting their temperatures. Conclusions. We find that the M giant actually does not stricto sensus fill its Roche lobe. The mass transfer is more likely to occur through the accretion of an important part of the giant wind. We finally rise the possibility for an enhanced mass loss from the giant, and we show that an accretion disc should have formed around the A star.
[26]  oai:arXiv.org:1109.1918  [pdf] - 1083951
PIONIER: a 4-telescope visitor instrument at VLTI
Comments:
Submitted: 2011-09-09
PIONIER stands for Precision Integrated-Optics Near-infrared Imaging ExpeRiment. It combines four 1.8m Auxilliary Telescopes or four 8m Unit Telescopes of the Very Large Telescope Interferometer (ESO, Chile) using an integrated optics combiner. The instrument has been integrated at IPAG starting in December 2009 and commissioned at the Paranal Observatory in October 2010. It provides scientific observations since November 2010. In this paper, we detail the instrumental concept, we describe the standard operational modes and the data reduction strategy. We present the typical performance and discuss how to improve them. This paper is based on laboratory data obtained during the integrations at IPAG, as well as on-sky data gathered during the commissioning at VLTI. We illustrate the imaging capability of PIONIER on the binaries deltaSco and HIP11231. PIONIER provides 6 visibilities and 3 independent closure phases in the H band, either in a broadband mode or with a low spectral dispersion (R=40), using natural light (i.e. unpolarized). The limiting magnitude is Hmag=7 in dispersed mode under median atmospheric conditions (seeing<1", tau0>3ms) with the 1.8m Auxiliary Telescopes. We demonstrate a precision of 0.5deg on the closure phases. The precision on the calibrated visibilities ranges from 3 to 15% depending on the atmospheric conditions. PIONIER has been installed and successfully tested as a visitor instrument for the VLTI. It permits high angular resolution imaging studies at an unprecedented level of sensitivity. The successful combination of the four 8m Unit Telescopes in March 2011 demonstrates that VLTI is ready for 4-telescope operation.
[27]  oai:arXiv.org:1106.1384  [pdf] - 369699
A PIONIER and incisive look at the interacting binary SS Lep
Comments: 6 pages, 4 figures. Proceeding of the ESO workshop "Evolution of Compact Binaries" (Vina del Mar, Chile, march 2011), ASP Conf. Series
Submitted: 2011-06-07
Symbiotic stars are eccellent laboratories to study a broad range of poorly understood physical processes, such as mass loss of red giants, accretion onto compact objects, and evolution of nova-like outbursts. As their evolution is strongly influenced by the mass transfer episodes, understanding the history of these systems requires foremost to determine which process is at play: Roche lobe overflow, stellar wind accretion, or some more complex mixture of both. We report here an interferometric study of the symbiotic system SS Leporis, performed with the unique PIONIER instrument. By determining the binary orbit and revisiting the parameters of the two stars, we show that the giant does not fill its Roche lobe, and that the mass transfer most likely occurs via the accretion of an important part of the giant's wind.
[28]  oai:arXiv.org:1104.1934  [pdf] - 1053278
Optimized fringe sensors for the VLTI next generation instruments
Comments: 18 pages, 11 figures. Accepted in Astronomy and Astrophysics
Submitted: 2011-04-11
Context. With the arrival of the next generation of ground-based imaging interferometers combining from 4 to possibly 6 telescopes simultaneously, there is also a strong need for a new generation of fringe trackers able to cophase such arrays. These instruments have to be very sensitive and to provide robust operations in quickly varying observational conditions. Aims. We aim at defining the optimal characteristics of fringe sensor concepts operating with 4 or 6 telescopes. The current detector limitations impose us to consider solutions based on co-axial pairwise combination schemes. Methods. We independently study several aspects of the fringe sensing process: 1) how to measure the phase and the group delay, and 2) how to combine the telescopes in order to ensure a precise and robust fringe tracking in real conditions. Thanks to analytical developments and numerical simulations, we define the optimal fringe-sensor concepts and compute the expected performance of the 4-telescope one with our dedicated end-to-end simulation tool sim2GFT. Results. We first show that measuring the phase and the group delay by obtaining the data in several steps (i.e. by temporally modulating the optical path difference) is extremely sensitive to atmospheric turbulence and therefore conclude that it is better to obtain the fringe position with a set of data obtained simultaneously. Subsequently, we show that among all co-axial pairwise schemes, moderately redundant concepts increase the sensitivity as well as the robustness in various atmospheric or observing conditions. Merging all these results, end-to-end simulations show that our 4-telescope fringe sensor concept is able to track fringes at least 90% of the time up to limiting magnitudes of 7.5 and 9.5 for the 1.8- and 8.2-meter VLTI telescopes respectively.
[29]  oai:arXiv.org:1009.1797  [pdf] - 1034836
Estimating the phase in ground-based interferometry: performance comparison between single-mode and multimode schemes
Comments: 9 pages (+ 11 online material appendices) -- 8 Figures. Accepted in A&A
Submitted: 2010-09-09
In this paper we compare the performance of multi and single-mode interferometry for the estimation of the phase of the complex visibility. We provide a theoretical description of the interferometric signal which enables to derive the phase error in presence of detector, photon and atmospheric noises, for both multi and single-mode cases. We show that, despite the loss of flux occurring when injecting the light in the single-mode component (i.e. single-mode fibers, integrated optics), the spatial filtering properties of such single-mode devices often enable higher performance than multimode concepts. In the high flux regime speckle noise dominated, single-mode interferometry is always more efficient, and its performance is significantly better when the correction provided by adaptive optics becomes poor, by a factor of 2 and more when the Strehl ratio is lower than 10%. In low light level cases (detector noise regime), multimode interferometry reaches better performance, yet the gain never exceeds 20%, which corresponds to the percentage of photon loss due to the injection in the guides. Besides, we demonstrate that single-mode interferometry is also more robust to the turbulence in both cases of fringe tracking and phase referencing, at the exception of narrow field of views (<1 arcsec).
[30]  oai:arXiv.org:1008.5352  [pdf] - 1034577
PIONIER: a visitor instrument for the VLTI
Comments: Proceedings of SPIE conference Optical and Infrared Interferometry II (Conference 7734) San Diego 2010
Submitted: 2010-08-31
PIONIER is a 4-telescope visitor instrument for the VLTI, planned to see its first fringes in 2010. It combines four ATs or four UTs using a pairwise ABCD integrated optics combiner that can also be used in scanning mode. It provides low spectral resolution in H and K band. PIONIER is designed for imaging with a specific emphasis on fast fringe recording to allow closure-phases and visibilities to be precisely measured. In this work we provide the detailed description of the instrument and present its updated status.
[31]  oai:arXiv.org:1008.4267  [pdf] - 218996
The Planar Optics Phase Sensor: a study for the VLTI 2nd Generation Fringe Tracker
Comments:
Submitted: 2010-08-25
In a few years, the second generation instruments of the Very Large Telescope Interferometer (VLTI) will routinely provide observations with 4 to 6 telescopes simultaneously. To reach their ultimate performance, they will need a fringe sensor capable to measure in real time the randomly varying optical paths differences. A collaboration between LAOG (PI institute), IAGL, OCA and GIPSA-Lab has proposed the Planar Optics Phase Sensor concept to ESO for the 2nd Generation Fringe Tracker. This concept is based on the integrated optics technologies, enabling the conception of extremely compact interferometric instruments naturally providing single-mode spatial filtering. It allows operations with 4 and 6 telescopes by measuring the fringes position thanks to a spectrally dispersed ABCD method. We present here the main analysis which led to the current concept as well as the expected on-sky performance and the proposed design.