Normalized to: Blais-Ouellette, S.
[1]
oai:arXiv.org:0911.4495 [pdf] - 1378526
Extreme faint flux imaging with an EMCCD
Submitted: 2009-11-23
An EMCCD camera, designed from the ground up for extreme faint flux imaging,
is presented. CCCP, the CCD Controller for Counting Photons, has been
integrated with a CCD97 EMCCD from e2v technologies into a scientific camera at
the Laboratoire d'Astrophysique Exp\'erimentale (LAE), Universit\'e de
Montr\'eal. This new camera achieves sub-electron read-out noise and very low
Clock Induced Charge (CIC) levels, which are mandatory for extreme faint flux
imaging. Data gathered with the camera suggests that through enhanced
manufacturing processes, which would avoid traps from being created, and with
the help of the clock shapes producible with CCCP, the CIC generated during the
vertical transfer could be virtually suppressed. The camera has been
characterized in laboratory and used on the Observatoire du Mont M\'egantic
1.6-m telescope. The performance of the camera is discussed and experimental
data with the first scientific data are presented.
[2]
oai:arXiv.org:0908.0528 [pdf] - 1003272
Extreme faint flux imaging with an EMCCD
Submitted: 2009-08-05
An EMCCD camera, designed from the ground up for extreme faint flux imaging,
is presented. CCCP, the CCD Controller for Counting Photons, has been
integrated with a CCD97 EMCCD from e2v technologies into a scientific camera at
the Laboratoire d'Astrophysique Experimentale (LAE), Universite de Montreal.
This new camera achieves sub-electron read-out noise and very low Clock Induced
Charge (CIC) levels, which are mandatory for extreme faint flux imaging. It has
been characterized in laboratory and used on the Observatoire du Mont Megantic
1.6-m telescope. The performance of the camera is discussed and experimental
data with the first scientific data are presented.
[3]
oai:arXiv.org:0807.0363 [pdf] - 14134
CCCP: A CCD Controller for Counting Photons
Submitted: 2008-07-02
CCCP, a CCD Controller for Counting Photons, is presented. This new
controller uses a totally new clocking architecture and allows to drive the CCD
in a novel way. Its design is optimized for the driving of EMCCDs at up to
20MHz of pixel rate and fast vertical transfer. Using this controller, the
dominant source of noise of EMCCDs at low flux level and high frame rate, the
Clock Induced Charges, were reduced to 0.001 - 0.0018 electron/pixel/frame
(depending of the electron multiplying gain), making efficient photon counting
possible. CCCP will be deployed in 2009 on the ESO NTT through the 3D-NTT1
project and on the SOAR through the BTFI project.
[4]
oai:arXiv.org:astro-ph/0606203 [pdf] - 82643
Faint flux performance of an EMCCD
Submitted: 2006-06-08
Thorough numerical simulations were run to test the performance of three
processing methods of the data coming out from an electron multiplying charge
coupled device (EMCCD), or low light level charge coupled device (L3CCD),
operated at high gain, under real operating conditions. The effect of read-out
noise and spurious charges is tested under various low flux conditions (0.001
event/pixel/frame < f < 20 events/pixel/frame). Moreover, a method for finding
the value of the gain applied by the EMCCD amplification register is also
developed. It allows one to determine the gain value to an accuracy of a
fraction of a percent from dark frames alone.
[5]
oai:arXiv.org:astro-ph/0411001 [pdf] - 68600
Accurate determination of the mass distribution in spiral galaxies III.
Fabry-Perot imaging spectroscopy of 6 spiral galaxies
Submitted: 2004-10-29
High resolution Fabry-Perot data of six spiral galaxies are presented. Those
data extend the previous sample of spiral galaxies studied with high resolution
3D spectroscopy to earlier morphological types. All the galaxies in the sample
have available HI data at 21 cm from the VLA or Westerbork. Velocity fields are
analyzed and Halpha rotation curves are computed and compared to HI curves. The
kinematics of NGC 5055 central regions are looked at more closely. Its peculiar
kinematics can be interpreted either as a bipolar outflow or as a
counter-rotating disk, possibly hosting a 9 pm 2 10^8 Msol compact object. Most
of the Halpha rotation curves present a significantly steeper inner slope than
their HI counterparts. The 21 cm data thus seems affected by moderate to strong
beam smearing. The beam smearing has an effect at higher
scale-length/beam-width than previously thought (up to 20 km/s at a ratio of
8.5).
[6]
oai:arXiv.org:astro-ph/0203501 [pdf] - 48522
LIFTS: an Imaging Fourier Transform Spectrograph for Astronomy
Submitted: 2002-03-27
We present the first astronomical observations of the Livermore Imaging
Fourier Transform Spectrograph for visible-band astronomy using the 3.5-meter
Apache Point Observatory.
[7]
oai:arXiv.org:astro-ph/0203146 [pdf] - 48167
Multiwavelength Rotation Curves to Test Dark Halo Central Shapes
Submitted: 2002-03-09
We use Fabry-Perot Halpha spectroscopy, complemented with published HI radio
synthesis observations to derive high resolution rotation curves of spiral
galaxies. We investigate precisely their inner mass distribution and compare it
to CDM simulations predictions. Having verified the existence of the so-called
core-cusp problem, we find that the dark halo density inner slope is related to
the galaxy masses. Dwarf galaxies with V_max < 100 km/s have halo density inner
slope 0 < \gamma < 0.7 while galaxies with V_max > 100 km/s are best fitted by
\gamma >= 1.
[8]
oai:arXiv.org:astro-ph/0107489 [pdf] - 43860
HST Imagery and CFHT Fabry-Perot 2-D Spectroscopy in Halpha of the
Ejected Nebula M1-67: Turbulent Status
Submitted: 2001-07-25
With HST-WFPC2 we have obtained a deep, H-alpha image of the WR nebula M1-67.
With the interferometer of the Universite Laval (Quebec, Canada), we have
obtained complementary Fabry-Perot H-alpha data using CFHT MOS/SIS. On the deep
H-alpha image we have performed continuous wavelet transforms to isolate
stochastic structures of different characteristic size and look for scaling
laws. Small-scale wavelet coefficients show that the density field of M1-67 is
remarkably structured in chaotically oriented filaments. We draw attention to a
short, marginally inertial range at the smallest scales (6.7-15.0 X 10^{-3}
pc), which can be attributed to turbulence in M1-67, and a strong scale break
at larger scales. Using our Fabry-Perot interferograms, we also present an
investigation of the statistical properties of fluctuating gas motions using
structure functions traced by H-alpha emission-line centroid velocities. We
find that there is a clear correlation at scales 0.02-0.22 pc between the mean
quadratic differences of radial velocities and distance over the surface of the
nebula. This implies that the velocity field shows an inertial range likely
related to turbulence. The first and second order moments of the velocity
increments are found to scale as <|Delta v(r)|> ~ r^{0.5} and <|Delta v(r)|^2>
\~ r^{0.9}. The former scaling law strongly suggests that compressible
turbulence is at play in M1-67, on the other hand, the latter scaling law
agrees very well with Larson-type laws for velocity turbulence. Examination of
the structure functions for different orders shows that the turbulent regime is
slightly intermittent and highly multifractal with universal multifractal
indexes alpha ~ 1.90-1.92 and C_1 ~ 0.04 \pm 0.01.
[9]
oai:arXiv.org:astro-ph/0006449 [pdf] - 36829
Accurate Determination of the Mass Distribution in Spiral Galaxies: II.
Testing the Shape of Dark Halos
Submitted: 2000-06-30, last modified: 2001-02-24
New high resolution CFHT Fabry-Perot data, combined with published VLA 21 cm
observations are used to determine the mass distribution of NGC 3109 and IC
2574. The multi-wavelength rotation curves allow to test with confidence
different dark halo functional forms from the pseudo-isothermal sphere to some
popular halo distributions motivated by N-body simulations. It appears that
density distribution with an inner logarithmic slope <= -1 are very hard to
reconcile with rotation curves of late type spirals. Modified Newtonian
Dynamics (MOND) is also considered as a potential solution to missing mass and
tested the same way. The new higher resolution data show that MOND can
reproduce in details the rotation curve of IC 2574 but confirm its difficulty
to fit the kinematics of NGC 3109.
[10]
oai:arXiv.org:astro-ph/9911223 [pdf] - 109351
Accurate Parameters of the Mass Distribution in Spiral Galaxies: 1.
Fabry - Perot Observations of NGC 5585
Submitted: 1999-11-12
Using the example of the Sd galaxy NGC 5585, it is shown that high resolution
2-D HII kinematical data are necessary to determine accurately the parameters
of the mass distribution in spirals. New CFHT Fabry-Perot Halpha observations
are combined with low resolution (20") Westerbork HI data to study its mass
distribution. Using the combined rotation curve and best fit models, it can be
seen that M/L of the luminous disk goes from 0.3 using only the HI rotation
curve, to 0.8 using both the optical and the radio data. This reduces the
dark-to-luminous mass ratio in NGC 5585 by ~30% through increasing the dark
matter halo core radius by nearly the same amount. This shows the importance of
the inner, rising part of the rotation curve for the accurate determination of
the parameters of the global mass (luminous & dark) distribution and suggests
that such a fine tuning of the rotation velocities using high resolution 2-D
HII kinematics is necessary to look at correlations between the parameters of
the dark matter component and other properties of galaxies.
[11]
oai:arXiv.org:astro-ph/9812396 [pdf] - 104503
A massive object in the core of NGC 5055?
Submitted: 1998-12-21
In a global kinematical study of NGC 5055 using high resolution Fabry-Perot,
intriguing spectral line profiles have been observed in the center of the
galaxy. These profiles seem to indicate a rapidly rotating disk with a radius
near 365 pc and tilted 50 $\deg$ with respect to the major axis of the galaxy.
In the hypothesis of a massive dark object, a naive keplerian estimate gives a
mass around $10^7.2$ to $10^7.5 M_\odot$. The limited spectral domain of the
Fabry-Perot leaves some ambiguity on the exact movement and velocity of this
H$\alpha$ emission. 2-D spectroscopy with a larger spectral range (eg.: TIGRE,
OASIS) is thus required.
[12]
oai:arXiv.org:astro-ph/9811142 [pdf] - 103768
Necessity for High Accuracy Rotation Curves in Spiral Galaxies
Submitted: 1998-11-09
In the last 20 years, rotation curves derived from H I kinematics obtained on
radio synthesis instruments were used to probe the dark matter distribution in
spiral and dwarf irregular galaxies. It is shown, with the aid of the Sd galaxy
NGC 5585, that high resolution 2--D H II kinematics is necessary to determine
accurately the mass distribution of spirals. New CFHT Fabry--Perot Hff
observations are combined with low resolution Westerbork H I data to study its
mass distribution. Using the combined rotation curve and best fit models, it
can be seen that the (M/LB) of the luminous disk goes from 0.3, using only the
H I rotation curve, to 0.8, using both the optical and the radio data. This
reduces the dark--to--luminous mass ratio by 30%.