Normalized to: Blackhurst, E.
[1]
oai:arXiv.org:1904.09991 [pdf] - 1966719
First radial velocity results from the MINiature Exoplanet Radial
Velocity Array (MINERVA)
Wilson, Maurice L.;
Eastman, Jason D.;
Cornachione, Matthew A.;
Wang, Sharon X.;
Johnson, Samson A.;
Sliski, David H.;
Schap, William J.;
Morton, Timothy D.;
Johnson, John Asher;
McCrady, Nate;
Wright, Jason T.;
Wittenmyer, Robert A.;
Plavchan, Peter;
Blake, Cullen H.;
Swift, Jonathan J.;
Bottom, Michael;
Baker, Ashley D.;
Barnes, Stuart I.;
Berlind, Perry;
Blackhurst, Eric;
Beatty, Thomas G.;
Bolton, Adam S.;
Cale, Bryson;
Calkins, Michael L.;
Colón, Ana;
de Vera, Jon;
Esquerdo, Gilbert;
Falco, Emilio E.;
Fortin, Pascal;
Garcia-Mejia, Juliana;
Geneser, Claire;
Gibson, Steven R.;
Grell, Gabriel;
Groner, Ted;
Halverson, Samuel;
Hamlin, John;
Henderson, M.;
Horner, J.;
Houghton, Audrey;
Janssens, Stefaan;
Jonas, Graeme;
Jones, Damien;
Kirby, Annie;
Lawrence, George;
Luebbers, Julien Andrew;
Muirhead, Philip S.;
Myles, Justin;
Nava, Chantanelle;
Rivera-García, Kevin O;
Reed, Tony;
Relles, Howard M.;
Riddle, Reed;
Robinson, Connor;
de Saintonge, Forest Chaput;
Sergi, Anthony
Submitted: 2019-04-22, last modified: 2019-09-11
The MINiature Exoplanet Radial Velocity Array (MINERVA) is a dedicated
observatory of four 0.7m robotic telescopes fiber-fed to a KiwiSpec
spectrograph. The MINERVA mission is to discover super-Earths in the habitable
zones of nearby stars. This can be accomplished with MINERVA's unique
combination of high precision and high cadence over long time periods. In this
work, we detail changes to the MINERVA facility that have occurred since our
previous paper. We then describe MINERVA's robotic control software, the
process by which we perform 1D spectral extraction, and our forward modeling
Doppler pipeline. In the process of improving our forward modeling procedure,
we found that our spectrograph's intrinsic instrumental profile is stable for
at least nine months. Because of that, we characterized our instrumental
profile with a time-independent, cubic spline function based on the profile in
the cross dispersion direction, with which we achieved a radial velocity
precision similar to using a conventional "sum-of-Gaussians" instrumental
profile: 1.8 m s$^{-1}$ over 1.5 months on the RV standard star HD 122064.
Therefore, we conclude that the instrumental profile need not be perfectly
accurate as long as it is stable. In addition, we observed 51 Peg and our
results are consistent with the literature, confirming our spectrograph and
Doppler pipeline are producing accurate and precise radial velocities.
[2]
oai:arXiv.org:1401.4690 [pdf] - 780687
The QUIJOTE CMB Experiment: status and first results with the
multi-frequency instrument
López-Caniego, M.;
Rebolo, R.;
Aguiar, M.;
Génova-Santos, R.;
Gómez-Reñasco, F.;
Gutierrez, C.;
Herreros, J. M.;
Hoyland, R. J.;
López-Caraballo, C.;
Santos, A. E. Pelaez;
Poidevin, F.;
Rubiño-Martín, J. A.;
de la Rosa, V. Sanchez;
Tramonte, D.;
Vega-Moreno, A.;
Viera-Curbelo, T.;
Vignaga, R.;
Martínez-González, E.;
Barreiro, R. B.;
Casaponsa, B.;
Casas, F. J.;
Diego, J. M.;
Fernández-Cobos, R.;
Herranz, D.;
Ortiz, D.;
Vielva, P.;
Artal, E.;
Aja, B.;
Cagigas, J.;
Cano, J. L.;
de la Fuente, L.;
Mediavilla, A.;
Terán, J. V.;
Villa, E.;
Piccirillo, L.;
Battye, R.;
Blackhurst, E.;
Brown, M.;
Davies, R. D.;
Davis, R. J.;
Dickinson, C.;
Grainge, K.;
Harper, S.;
Maffei, B.;
McCulloch, M.;
Melhuish, S.;
Pisano, G.;
Watson, R. A.;
Hobson, M.;
Lasenby, A.;
Saunders, R.;
Scott, P.
Submitted: 2014-01-19, last modified: 2014-02-05
The QUIJOTE (Q-U-I JOint Tenerife) CMB Experiment is designed to observe the
polarization of the Cosmic Microwave Background and other Galactic and
extragalactic signals at medium and large angular scales in the frequency range
of 10-40 GHz. The first of the two QUIJOTE telescopes and the multi-frequency
(10-20 GHz) instrument have been in operation since November 2012. In 2014 a
second telescope and a new instrument at 30GHz will be ready for commissioning,
and an additional instrument at 40 GHz is in its final design stages. After
three years of effective observations, the data obtained by these telescopes
and instruments will have the required sensitivity to detect a primordial
gravitational-wave component if the tensor-to-scalar ratio is larger than r =
0.05. At the moment, we have completed half of the wide Galactic survey with
the multi-frequency instrument covering 18 000 square degrees of the Northern
hemisphere. When we finish this survey in early 2014, we shall have reached
approximately 14{\mu}K per one degree beam at 11, 13, 17 and 19 GHz, in both Q
and U.
[3]
oai:arXiv.org:1310.7129 [pdf] - 1180262
The C-Band All-Sky Survey (C-BASS): Design and implementation of the
northern receiver
King, O. G.;
Jones, Michael E.;
Blackhurst, E. J.;
Copley, C.;
Davis, R. J.;
Dickinson, C.;
Holler, C. M.;
Irfan, M. O.;
John, J. J.;
Leahy, J. P.;
Leech, J.;
Muchovej, S. J. C.;
Pearson, T. J.;
Stevenson, M. A.;
Taylor, Angela C.
Submitted: 2013-10-26, last modified: 2013-12-03
The C-Band All-Sky Survey (C-BASS) is a project to map the full sky in total
intensity and linear polarization at 5 GHz. The northern component of the
survey uses a broadband single-frequency analogue receiver fitted to a 6.1-m
telescope at the Owens Valley Radio Observatory in California, USA. The
receiver architecture combines a continuous-comparison radiometer and a
correlation polarimeter in a single receiver for stable simultaneous
measurement of both total intensity and linear polarization, using
custom-designed analogue receiver components. The continuous-comparison
radiometer measures the temperature difference between the sky and
temperature-stabilized cold electrical reference loads. A cryogenic front-end
is used to minimize receiver noise, with a system temperature of $\approx
30\,$K in both linear polarization and total intensity. Custom cryogenic notch
filters are used to counteract man-made radio frequency interference. The
radiometer $1/f$ noise is dominated by atmospheric fluctuations, while the
polarimeter achieves a $1/f$ noise knee frequency of 10 mHz, similar to the
telescope azimuthal scan frequency.
[4]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[5]
oai:arXiv.org:1001.4608 [pdf] - 33147
Noise Properties of the Planck-LFI Receivers
Meinhold, P.;
Leonardi, R.;
Aja, B.;
Artal, E.;
Battaglia, P.;
Bersanelli, M.;
Blackhurst, E.;
Butler, C. R.;
Cuevas, L. P.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R.;
de la Fuente, M. L.;
Frailis, M.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gregorio, A.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Leutenegger, P.;
Lowe, S. R.;
Malaspina, M.;
Mandolesi, R.;
Maris, M.;
Martínez-González, E.;
Mendes, L.;
Mennella, A.;
Miccolis, M.;
Morgante, G.;
Roddis, N.;
Sandri, M.;
Seiffert, M.;
Salmón, M.;
Stringhetti, L.;
Poutanen, T.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Varis, J.;
Valenziano, L.;
Villa, F.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) radiometers have been tested
extensively during several dedicated campaigns. The present paper reports the
principal noise properties of the LFI radiometers.
[6]
oai:arXiv.org:1001.4743 [pdf] - 33184
Design, development and verification of the 30 and 44 GHz front-end
modules for the Planck Low Frequency Instrument
Davis, R. J.;
Wilkinson, A.;
Davies, R. D.;
Winder, W. F.;
Roddis, N.;
Blackhurst, E. J.;
Lawson, D.;
Lowe, S. R.;
Baines, C.;
Butlin, M.;
Galtress, A.;
Shepherd, D.;
Aja, B.;
Artal, E.;
Bersanelli, M.;
Butler, R. C.;
Castelli, C.;
Cuttaia, F.;
D'Arcangelo, O.;
Gaier, T.;
Hoyland, R.;
Kettle, D.;
Leonardi, R.;
Mandolesi, N.;
Mennella, A.;
Meinhold, P.;
Pospieszalski, M.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zonca, A.
Submitted: 2010-01-26
We give a description of the design, construction and testing of the 30 and
44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the
Planck mission to be launched in 2009. The scientific requirements of the
mission determine the performance parameters to be met by the FEMs, including
their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in
which the signal from the sky is compared with a 4-K blackbody load. The Low
Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High
Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel
phase-switch design which gives excellent amplitude and phase match across the
band.
The noise temperature requirements are met within the measurement errors at
the two frequencies. For the most sensitive LNAs, the noise temperature at the
band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively.
For some of the FEMs, the noise temperature is still falling as the ambient
temperature is reduced to 20 K. Stability tests of the FEMs, including a
measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all
critical aspects. The most sensitive LNAs have reached new limits of noise
temperature for HEMTs at their band centres. The FEMs have well-defined linear
polarization characteristcs.
[7]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.
[8]
oai:arXiv.org:astro-ph/0307116 [pdf] - 57829
Advanced pseudo-correlation radiometers for the Planck-LFI instrument
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Maino, D.;
Mandolesi, N.;
Morgante, G.;
Valenziano, L.;
Villa, F.;
Gaier, T.;
Seiffert, M.;
Levin, S.;
Lawrence, C.;
Meinhold, P.;
Lubin, P.;
Tuovinen, J.;
Varis, J.;
Karttaavi, T.;
Hughes, N.;
Jukkala, P.;
Sjman, P.;
Kangaslahti, P.;
Roddis, N.;
Kettle, D.;
Winder, F.;
Blackhurst, E.;
Davis, R.;
Wilkinson, A.;
Castelli, C.;
Aja, B.;
Artal, E.;
de la Fuente, L.;
Mediavilla, A.;
Pascual, J. P.;
Gallegos, J.;
Martinez-Gonzalez, E.;
de Paco, P.;
Pradell, L.
Submitted: 2003-07-07
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is
constituted by an array of radiometric detectors actively cooled at 20 K in the
30-70 GHz frequency range in the focal plane of the Planck telescope. In this
paper we present an overview of the LFI instrument, with a particular focus on
the radiometer design. The adopted pseudo-correlation scheme uses a software
balancing technique (with a tunable parameter called gain modulation factor)
which is effective in reducing the radiometer susceptibility to amplifier
instabilities also in presence of small non-idealities in the radiometric chain
components, provided that the gain modulation factor is estimated with an
accuracy of the order of 0.2%. These results have been recently confirmed by
experimental laboratory measurements conducted on the LFI prototype radiometers
at 30, 70 and 100 GHz.