Normalized to: Blackburn, C.
[1]
oai:arXiv.org:1006.3102 [pdf] - 190657
The Fibre Multi-Object Spectrograph (FMOS) for Subaru Telescope
Kimura, Masahiko;
Maihara, Toshinori;
Iwamuro, Fumihide;
Akiyama, Masayuki;
Tamura, Naoyuki;
Dalton, Gavin B.;
Takato, Naruhisa;
Tait, Philip;
Ohta, Kouji;
Eto, Shigeru;
Mochida, Daisaku;
Elms, Brian;
Kawate, Kaori;
Kurakami, Tomio;
Moritani, Yuuki;
Noumaru, Junichi;
Ohshima, Norio;
Sumiyoshi, Masanao;
Yabe, Kiyoto;
Brzeski, Jurek;
Farrell, Tony;
Frost, Gabriella;
Gillingham, Peter R.;
Haynes, Roger;
Moore, Anna M.;
Muller, Rolf;
Smedley, Scott;
Smith, Greg;
Bonfield, David G.;
Brooks, Charles B.;
Holmes, Alan R.;
Lake, Emma Curtis;
Lee, Hanshin;
Lewis, Ian J.;
Froud, Tim R.;
Tosh, Ian A.;
Woodhouse, Guy F.;
Blackburn, Colin;
Dipper, Nigel;
Murray, Graham;
Sharples, Ray;
Robertson, David J.
Submitted: 2010-06-15
Fibre Multi-Object Spectrograph (FMOS) is the first near-infrared instrument
with a wide field of view capable of acquiring spectra simultaneously from up
to 400 objects. It has been developed as a common-use instrument for the F/2
prime-focus of the Subaru Telescope. The field coverage of 30' diameter is
achieved using a new 3-element corrector optimized in the near-infrared
(0.9-1.8um) wavelength range. Due to limited space at the prime-focus, we have
had to develop a novel fibre positioner called "Echidna" together with two
OH-airglow suppressed spectrographs. FMOS consists of three subsystems: the
prime focus unit for IR, the fibre positioning system/connector units, and the
two spectrographs. After full systems integration, FMOS was installed on the
telescope in late 2007. Many aspects of performance were checked through
various test and engineering observations. In this paper, we present the
optical and mechanical components of FMOS and show the results of our on-sky
engineering observations to date.
[2]
oai:arXiv.org:astro-ph/0609069 [pdf] - 260784
Cryogenic tests of volume-phase holographic gratings: results at 100 K
Submitted: 2006-09-04
We present results from cryogenic tests of Volume-Phase Holographic(VPH)
gratings at 100 K. The aims of these tests are to see whether the diffraction
efficiency as a function of wavelength is significantly different at a low
temperature from that at room temperature and to see how the performance of a
VPH grating is affected by a number of thermal cycles. We have completed 10
cycles between room temperature and 100 $K$, and find no clear evidence that
the diffraction efficiency changes with temperature or with successive thermal
cycle.
[3]
oai:arXiv.org:astro-ph/0311517 [pdf] - 61097
Cryogenic Tests of Volume-Phase Holographic Gratings: I. Results at 200
K
Submitted: 2003-11-22
We present results from cryogenic tests of a Volume-Phase Holographic (VPH)
grating at 200 K measured at near-infrared wavelengths. The aims of these tests
were to see whether the diffraction efficiency and angular dispersion of a VPH
grating are significantly different at a low temperature from those at a room
temperature, and to see how many cooling and heating cycles the grating can
withstand. We have completed 5 cycles between room temperature and 200 K, and
find that the performance is nearly independent of temperature, at least over
the temperature range which we are investigating. In future, we will not only
try more cycles between these temperatures but also perform measurements at a
much lower temperature (e.g., 80 K).