[1]  oai:arXiv.org:1907.02661  [pdf] - 1913005
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Comments:
Submitted: 2019-07-04, last modified: 2019-07-08
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
[2]  oai:arXiv.org:gr-qc/0401017  [pdf] - 111424
Whispering Gallery Resonators and Tests of Lorentz Invariance
Comments: 21 pages, 6 figures, accepted for General Relativity and Gravitation (January, 2004). New version with slight changes following the referee's suggestions
Submitted: 2004-01-06, last modified: 2004-02-10
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We give a detailed description of microwave resonators operating in Whispering Gallery modes and then apply it to derive explicit models for Lorentz violating effects in our experiment. Models are calculated in the theoretical framework of Robertson, Mansouri and Sexl and in the standard model extension (SME) of Kostelecky and co-workers. We constrain the parameters of the Mansouri and Sexl test theory to $1/2 - \beta_{MS} + \delta_{MS} = (1.2 \pm 2.2) \times 10^{-9}$ and $\beta_{MS} - \alpha_{MS} - 1 = (1.6 \pm 3.0) \times 10^{-7}$ which is of the same order as the best results from other experiments for the former and represents a 70 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2.
[3]  oai:arXiv.org:astro-ph/0310112  [pdf] - 1591979
Cold Atom Clocks, Precision Oscillators and Fundamental Tests
Comments: 13 pages, 5 figures
Submitted: 2003-10-04
We describe two experimental tests of the Equivalence Principle that are based on frequency measurements between precision oscillators and/or highly accurate atomic frequency standards. Based on comparisons between the hyperfine frequencies of 87Rb and 133Cs in atomic fountains, the first experiment constrains the stability of fundamental constants. The second experiment is based on a comparison between a cryogenic sapphire oscillator and a hydrogen maser. It tests Local Lorentz Invariance. In both cases, we report recent results which improve significantly over previous experiments.
[4]  oai:arXiv.org:gr-qc/0306047  [pdf] - 111265
Tests of Lorentz Invariance Using a Microwave Resonator: An Update
Comments: 6 pages, 2 figures, to appear in Proc. of the 2003 joint IEEE FCS/EFTF meeting, to appear in Proc. of the 2003 Rencontres de Moriond
Submitted: 2003-06-11
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to $\delta - \beta + 1/2 \leq 3.4 \times 10^{-9}$ and $\beta - \alpha - 1 \leq 4.1 \times 10^{-7}$ which is of the same order as the best previous result for the former and represents a 50 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2. We describe the changes of the experiment, and show the new data that lead to that improvement.
[5]  oai:arXiv.org:physics/0212112  [pdf] - 119004
A Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Comments: 4 pages, 3 figures, 1 table submitted to Phys. Rev. Lett
Submitted: 2002-12-31
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of nuclear magnetic moments and the fine structure constant.