Normalized to: Bize, S.
[1]
oai:arXiv.org:1907.02661 [pdf] - 1913005
Search for transient variations of the fine structure constant and dark
matter using fiber-linked optical atomic clocks
Roberts, B. M.;
Delva, P.;
Al-Masoudi, A.;
Amy-Klein, A.;
Bærentsen, C.;
Baynham, C. F. A.;
Benkler, E.;
Bilicki, S.;
Bize, S.;
Bowden, W.;
Calvert, J.;
Cambier, V.;
Cantin, E.;
Curtis, E. A.;
Dörscher, S.;
Favier, M.;
Frank, F.;
Gill, P.;
Godun, R. M.;
Grosche, G.;
Guo, C.;
Hees, A.;
Hill, I. R.;
Hobson, R.;
Huntemann, N.;
Kronjäger, J.;
Koke, S.;
Kuhl, A.;
Lange, R.;
Legero, T.;
Lipphardt, B.;
Lisdat, C.;
Lodewyck, J.;
Lopez, O.;
Margolis, H. S.;
Álvarez-Martínez, H.;
Meynadier, F.;
Ozimek, F.;
Peik, E.;
Pottie, P. -E.;
Quintin, N.;
Sanner, C.;
De Sarlo, L.;
Schioppo, M.;
Schwarz, R.;
Silva, A.;
Sterr, U.;
Tamm, Chr.;
Targat, R. Le;
Tuckey, P.;
Vallet, G.;
Waterholter, T.;
Xu, D.;
Wolf, P.
Submitted: 2019-07-04, last modified: 2019-07-08
We search for transient variations of the fine structure constant using data
from a European network of fiber-linked optical atomic clocks. By searching for
coherent variations in the recorded clock frequency comparisons across the
network, we significantly improve the constraints on transient variations of
the fine structure constant. For example, we constrain the variation in alpha
to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a
possibility to search for dark matter, the mysterious substance hypothesised to
explain galaxy dynamics and other astrophysical phenomena that is thought to
dominate the matter density of the universe. At the current sensitivity level,
we find no evidence for dark matter in the form of topological defects (or,
more generally, any macroscopic objects), and we thus place constraints on
certain potential couplings between the dark matter and standard model
particles, substantially improving upon the existing constraints, particularly
for large (>~10^4 km) objects.
[2]
oai:arXiv.org:gr-qc/0401017 [pdf] - 111424
Whispering Gallery Resonators and Tests of Lorentz Invariance
Submitted: 2004-01-06, last modified: 2004-02-10
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are
compared to set new constraints on a possible violation of Lorentz invariance.
We give a detailed description of microwave resonators operating in Whispering
Gallery modes and then apply it to derive explicit models for Lorentz violating
effects in our experiment. Models are calculated in the theoretical framework
of Robertson, Mansouri and Sexl and in the standard model extension (SME) of
Kostelecky and co-workers. We constrain the parameters of the Mansouri and Sexl
test theory to $1/2 - \beta_{MS} + \delta_{MS} = (1.2 \pm 2.2) \times 10^{-9}$
and $\beta_{MS} - \alpha_{MS} - 1 = (1.6 \pm 3.0) \times 10^{-7}$ which is of
the same order as the best results from other experiments for the former and
represents a 70 fold improvement for the latter. These results correspond to an
improvement of our previously published limits [Wolf P. et al., Phys. Rev.
Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2.
[3]
oai:arXiv.org:astro-ph/0310112 [pdf] - 1591979
Cold Atom Clocks, Precision Oscillators and Fundamental Tests
Bize, S.;
Wolf, P.;
Abgrall, M.;
Cacciapuoti, L.;
Clairon, A.;
Gruenert, J.;
Laurent, Ph.;
Lemonde, P.;
Maksimovic, I.;
Mandache, C.;
Marion, H.;
Santos, F. Pereira Dos;
Rosenbusch, P.;
Santarelli, G.;
Sortais, Y.;
Vian, C.;
Zhang, S.;
Salomon, C.;
Luiten, A. N.;
Tobar, M. E.
Submitted: 2003-10-04
We describe two experimental tests of the Equivalence Principle that are
based on frequency measurements between precision oscillators and/or highly
accurate atomic frequency standards. Based on comparisons between the hyperfine
frequencies of 87Rb and 133Cs in atomic fountains, the first experiment
constrains the stability of fundamental constants. The second experiment is
based on a comparison between a cryogenic sapphire oscillator and a hydrogen
maser. It tests Local Lorentz Invariance. In both cases, we report recent
results which improve significantly over previous experiments.
[4]
oai:arXiv.org:gr-qc/0306047 [pdf] - 111265
Tests of Lorentz Invariance Using a Microwave Resonator: An Update
Submitted: 2003-06-11
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are
compared to set new constraints on a possible violation of Lorentz invariance.
We determine the variation of the oscillator frequency as a function of its
orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike
test) with respect to a preferred frame candidate. We constrain the
corresponding parameters of the Mansouri and Sexl test theory to $\delta -
\beta + 1/2 \leq 3.4 \times 10^{-9}$ and $\beta - \alpha - 1 \leq 4.1 \times
10^{-7}$ which is of the same order as the best previous result for the former
and represents a 50 fold improvement for the latter. These results correspond
to an improvement of our previously published limits [Wolf P. et al., Phys.
Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2. We describe the
changes of the experiment, and show the new data that lead to that improvement.
[5]
oai:arXiv.org:physics/0212112 [pdf] - 119004
A Search for Variations of Fundamental Constants using Atomic Fountain
Clocks
Marion, H.;
Santos, F. Pereira Dos;
Abgrall, M.;
Zhang, S.;
Sortais, Y.;
Bize, S.;
Maksimovic, I.;
Calonico, D.;
Gruenert, J.;
Mandache, C.;
Lemonde, P.;
Santarelli, G.;
Laurent, Ph.;
Clairon, A.;
Salomon, C.
Submitted: 2002-12-31
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb
atoms in their electronic ground state using several laser cooled 133Cs and
87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a
stringent upper bound to a possible fractional time variation of the ratio
between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16}
yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation
of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of
nuclear magnetic moments and the fine structure constant.