Normalized to: Billard, J.
[1]
oai:arXiv.org:2003.01046 [pdf] - 2057126
First germanium-based constraints on sub-MeV Dark Matter with the
EDELWEISS experiment
EDELWEISS Collaboration;
Arnaud, Q.;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Elkhoury, E.;
Fillipini, J. -B.;
Filosofov, D.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Lattaud, H.;
Marnieros, S.;
Misiak, D.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Oriol, C.;
Pari, P.;
Paul, B.;
Poda, D.;
Rozov, S.;
Salagnac, T.;
Sanglard, V.;
Siebenborn, B.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zolotarova, A.
Submitted: 2020-03-02
The EDELWEISS collaboration has performed a search for Dark Matter (DM)
particles interacting with electrons using a 33.4 g Ge cryogenic detector
operated underground at the LSM. A charge resolution of 0.53 electron-hole
pairs (RMS) has been achieved using the Neganov-Trofimov-Luke amplification
with a bias of 78 V. We set the first Ge-based constraints on sub-MeV/c$^{2}$
DM particles interacting with electrons, as well as on dark photons down to 1
eV/c$^2$. These are competitive with other searches. In particular, new limits
are set on the kinetic mixing of dark photon DM in a so far unconstrained
parameter space region in the 6 to 9 eV/c$^2$ mass range. These results
demonstrate the high relevance of cryogenic Ge detectors for the search of DM
interactions producing eV-scale electron signals.
[2]
oai:arXiv.org:1901.03588 [pdf] - 1871473
Searching for low-mass dark matter particles with a massive Ge bolometer
operated above-ground
Armengaud, E.;
Augier, C.;
Benoît, A.;
Benoit, A.;
Bergé, L.;
Billard, J.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapelier, M.;
Charlieux, F.;
Ducimetière, D.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
De Jésus, M.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Maisonobe, R.;
Marnieros, S.;
Misiak, D.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Oriol, C.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Siebenborn, B.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zolotarova, A.;
Kavanagh, B. J.
Submitted: 2019-01-11, last modified: 2019-04-02
The EDELWEISS collaboration has performed a search for dark matter particles
with masses below the GeV-scale with a 33.4-g germanium cryogenic detector
operated in a surface lab. The energy deposits were measured using a
neutron-transmutation-doped Ge thermal sensor with a 17.7~eV (RMS) baseline
heat energy resolution leading to a 60~eV analysis energy threshold. Despite a
moderate lead shielding and the high-background environment, the first sub-GeV
spin-independent dark matter limit based on a germanium target has been
achieved. The experiment provides the most stringent, nuclear recoil based,
above-ground limit on spin-independent interactions above 600~MeV/c$^{2}$. The
experiment also provides the most stringent limits on spin-dependent
interactions with protons and neutrons below 1.3~GeV/c$^{2}$. Furthermore, the
dark matter search results were studied in the context of Strongly Interacting
Massive Particles, taking into account Earth-shielding effects, for which new
regions of the available parameter space have been excluded. Finally, the dark
matter search has also been extended to interactions via the Migdal effect,
resulting for the first time in the exclusion of particles with masses between
45 and 150~MeV/c$^{2}$ with spin-independent cross sections ranging from
$10^{-29}$ to $10^{-26}$~cm$^2$.
[3]
oai:arXiv.org:1707.04308 [pdf] - 1622237
Optimizing EDELWEISS detectors for low-mass WIMP searches
EDELWEISS Collaboration;
Arnaud, Q.;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Maisonobe, R.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Siebenborn, B.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2017-07-11
The physics potential of EDELWEISS detectors for the search of low-mass
Weakly Interacting Massive Particles (WIMPs) is studied. Using a data-driven
background model, projected exclusion limits are computed using frequentist and
multivariate analysis approaches, namely profile likelihood and boosted
decision tree. Both current and achievable experimental performance are
considered. The optimal strategy for detector optimization depends critically
on whether the emphasis is put on WIMP masses below or above $\sim$ 5
GeV/c$^2$. The projected sensitivity for the next phase of the EDELWEISS-III
experiment at the Modane Underground Laboratory (LSM) for low-mass WIMP search
is presented. By 2018 an upper limit on the spin-independent WIMP-nucleon
cross-section of $\sigma_{SI} = 7 \times 10^{-42}$ cm$^2$ is expected for a
WIMP mass in the range 2$-$5 GeV/c$^2$. The requirements for a future
hundred-kilogram scale experiment designed to reach the bounds imposed by the
coherent scattering of solar neutrinos are also described. By improving the
ionization resolution down to 50 eV$_{ee}$, we show that such an experiment
installed in an even lower background environment (e.g. at SNOLAB) should allow
to observe about 80 $^8$B neutrino events after discrimination.
[4]
oai:arXiv.org:1706.01070 [pdf] - 1584219
Performance of the EDELWEISS-III experiment for direct dark matter
searches
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Maisonobe, R.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.;
Zolotarova, A.
Submitted: 2017-06-04
We present the results of measurements demonstrating the efficiency of the
EDELWEISS-III array of cryogenic germanium detectors for direct dark matter
searches. The experimental setup and the FID (Fully Inter-Digitized) detector
array is described, as well as the efficiency of the double measurement of heat
and ionization signals in background rejection. For the whole set of 24 FID
detectors used for coincidence studies, the baseline resolutions for the
fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the
baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM).
The response to nuclear recoils as well as the very good discrimination
capability of the FID design has been measured with an AmBe source. The surface
$\beta$- and $\alpha$-decay rejection power of $R_{\rm surf} < 4 \times
10^{-5}$ per $\alpha$ at 90% C.L. has been determined with a $^{210}$Pb source,
the rejection of bulk $\gamma$-ray events has been demonstrated using
$\gamma$-calibrations with $^{133}$Ba sources leading to a value of
$R_{\gamma{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels
of natural radioactivity measured in the detector array are shown as the rate
of single $\gamma$ background. The fiducial volume fraction of the FID
detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$
using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The
stability and uniformity of the detector response is also discussed. The
achieved resolutions, thresholds and background levels of the upgraded
EDELWEISS-III detectors in their setup are thus well suited to the direct
search of WIMP dark matter over a large mass range.
[5]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[6]
oai:arXiv.org:1607.03367 [pdf] - 1497465
Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile
likelihood approach
EDELWEISS Collaboration;
Hehn, L.;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Heuermann, G.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-07-12, last modified: 2016-09-20
We report on a dark matter search for a Weakly Interacting Massive Particle
(WIMP) in the mass range $m_\chi \in [4, 30]\,\mathrm{GeV}/c^2$ with the
EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data
from eight selected detectors with the lowest energy thresholds leading to a
combined fiducial exposure of 496 kg-days. External backgrounds from $\gamma$-
and $\beta$-radiation, recoils from $^{206}$Pb and neutrons as well as detector
intrinsic backgrounds were modelled from data outside the region of interest
and constrained in the analysis. The basic data selection and most of the
background models are the same as those used in a previously published analysis
based on Boosted Decision Trees (BDT). For the likelihood approach applied in
the analysis presented here, a larger signal efficiency and a subtraction of
the expected background lead to a higher sensitivity, especially for the lowest
WIMP masses probed. No statistically significant signal was found and upper
limits on the spin-independent WIMP-nucleon scattering cross section can be set
with a hypothesis test based on the profile likelihood test statistics. The 90%
C.L. exclusion limit set for WIMPs with $m_\chi = 4\,\mathrm{GeV/}c^2$ is $1.6
\times 10^{-39}\,\mathrm{cm^2}$, which is an improvement of a factor of seven
with respect to the BDT-based analysis. For WIMP masses above
$15\,\mathrm{GeV/}c^2$ the exclusion limits found with both analyses are in
good agreement.
[7]
oai:arXiv.org:1503.03379 [pdf] - 1458536
Dark matter effective field theory scattering in direct detection
experiments
Schneck, K.;
Cabrera, B.;
Cerdeno, D. G.;
Mandic, V.;
Rogers, H. E.;
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Caldwell, D. O.;
Calkins, R.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D. M.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Roberts, A.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yang, X.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-03-11, last modified: 2016-08-16
We examine the consequences of the effective field theory (EFT) of dark
matter-nucleon scattering for current and proposed direct detection
experiments. Exclusion limits on EFT coupling constants computed using the
optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX,
and the necessity of combining results from multiple experiments in order to
determine dark matter parameters is discussed. We demonstrate that spectral
differences between the standard dark matter model and a general EFT
interaction can produce a bias when calculating exclusion limits and when
developing signal models for likelihood and machine learning techniques. We
also discuss the implications of the EFT for the next-generation (G2) direct
detection experiments and point out regions of complementarity in the EFT
parameter space.
[8]
oai:arXiv.org:1607.04560 [pdf] - 1438577
Measurement of the cosmogenic activation of germanium detectors in
EDELWEISS-III
The EDELWEISS Collaboration;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Heuermann, G.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-07-15
We present a measurement of the cosmogenic activation in the germanium
cryogenic detectors of the EDELWEISS III direct dark matter search experiment.
The decay rates measured in detectors with different exposures to cosmic rays
above ground are converted into production rates of different isotopes. The
measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H,
2.8 $\pm$ 0.6 for $^{49}$V, 4.6 $\pm$ 0.7 for $^{55}$Fe, and 106 $\pm$ 13 for
$^{65}$Zn. These results are the most accurate for these isotopes. A lower
limit on the production rate of $^{68}$Ge of 74 nuclei/kg/day is also
presented. They are compared to model predictions present in literature and to
estimates calculated with the ACTIVIA code.
[9]
oai:arXiv.org:1606.08097 [pdf] - 1507589
Signals induced by charge-trapping in EDELWEISS FID detectors:
analytical modeling and applications
The EDELWEISS Collaboration;
Arnaud, Q.;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Fourches, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Heuermann, G.;
De Jésus, M.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kéfélian, C.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-06-26, last modified: 2016-06-29
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge
detectors Fully covered with Inter-Digitized electrodes (FID). They are
operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence
charge-carrier trapping significantly affects both the ionization and heat
energy measurements. This paper describes an analytical model of the signals
induced by trapped charges in FID detectors based on the Shockley-Ramo theorem.
It is used to demonstrate that veto electrodes, initially designed for the sole
purpose of surface event rejection, can be used to provide a sensitivity to the
depth of the energy deposits, characterize the trapping in the crystals,
perform heat and ionization energy corrections and improve the ionization
baseline resolutions. These procedures are applied successfully to actual data.
[10]
oai:arXiv.org:1603.05120 [pdf] - 1403150
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
EDELWEISS Collaboration;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
De Jésus, M.;
Jin, Y.;
Jokisch, S.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D. V.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2016-03-16, last modified: 2016-05-09
We present the results of a search for elastic scattering from galactic dark
matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30
GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an
array of 800 g Germanium bolometers equipped with a set of interleaved
electrodes with full surface coverage. We searched specifically for $\sim
2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an
illustration the number of observed events in the search for 5 (resp. 20)
GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1
(resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times
10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering
cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a
41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP
search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints
of WIMP signals from some recent experiments, thus confirming results obtained
with different detection techniques.
[11]
oai:arXiv.org:1602.03781 [pdf] - 1384743
A review of the discovery reach of directional Dark Matter detection
Mayet, F.;
Green, A. M.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Gelmini, G. B.;
Gondolo, P.;
Kavanagh, B. J.;
Lee, S. K.;
Loomba, D.;
Monroe, J.;
Morgan, B.;
O'Hare, C. A. J.;
Peter, A. H. G.;
Phan, N. S.;
Vahsen, S. E.
Submitted: 2016-02-11, last modified: 2016-03-17
Cosmological observations indicate that most of the matter in the Universe is
Dark Matter. Dark Matter in the form of Weakly Interacting Massive Particles
(WIMPs) can be detected directly, via its elastic scattering off target nuclei.
Most current direct detection experiments only measure the energy of the
recoiling nuclei. However, directional detection experiments are sensitive to
the direction of the nuclear recoil as well. Due to the Sun's motion with
respect to the Galactic rest frame, the directional recoil rate has a dipole
feature, peaking around the direction of the Solar motion. This provides a
powerful tool for demonstrating the Galactic origin of nuclear recoils and
hence unambiguously detecting Dark Matter. Furthermore, the directional recoil
distribution depends on the WIMP mass, scattering cross section and local
velocity distribution. Therefore, with a large number of recoil events it will
be possible to study the physics of Dark Matter in terms of particle and
astrophysical properties. We review the potential of directional detectors for
detecting and characterizing WIMPs.
[12]
oai:arXiv.org:1509.02448 [pdf] - 1371572
WIMP-Search Results from the Second CDMSlite Run
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Asai, M.;
Baker, W.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Roberts, A.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Underwood, R.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-09-08, last modified: 2016-03-09
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic
germanium detectors operated at a relatively high bias voltage to amplify the
phonon signal in the search for weakly interacting massive particles (WIMPs).
Results are presented from the second CDMSlite run with an exposure of 70 kg
days, which reached an energy threshold for electron recoils as low as 56 eV. A
fiducialization cut reduces backgrounds below those previously reported by
CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross
section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
[13]
oai:arXiv.org:1504.05871 [pdf] - 1293576
Improved WIMP-search reach of the CDMS II germanium data
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yang, X.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-04-22, last modified: 2015-10-13
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were
reprocessed with an improved charge-pulse fitting algorithm. Two new analysis
techniques to reject surface-event backgrounds were applied to the 612 kg days
germanium-detector WIMP-search exposure. An extended analysis was also
completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to
increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there
were zero candidate events above a deposited energy of 10 keV and 6 events in
the lower-threshold analysis. This yielded minimum WIMP-nucleon
spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and
$1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$
WIMPs, respectively. This improves the previous CDMS II result by a factor of
2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
[14]
oai:arXiv.org:1505.08061 [pdf] - 1279292
Readout strategies for directional dark matter detection beyond the
neutrino background
Submitted: 2015-05-29, last modified: 2015-09-18
The search for weakly interacting massive particles (WIMPs) by direct
detection faces an encroaching background due to coherent neutrino-nucleus
scattering. As the sensitivity of these experiments improves, the question of
how to best distinguish a dark matter signal from neutrinos will become
increasingly important. A proposed method of overcoming this so-called
'neutrino floor' is to utilize the directional signature that both neutrino and
dark matter induced recoils possess. We show that directional experiments can
indeed probe WIMP-nucleon cross-sections below the neutrino floor with little
loss in sensitivity due to the neutrino background. In particular we find at
low WIMP masses (around 6 GeV) the discovery limits for directional detectors
penetrate below the non-directional limit by several orders of magnitude. For
high WIMP masses (around 100 GeV), the non-directional limit is overcome by a
factor of a few. Furthermore we show that even for directional detectors which
can only measure 1- or 2-dimensional projections of the 3-dimensional recoil
track, the discovery potential is only reduced by a factor of 3 at most. We
also demonstrate that while the experimental limitations of directional
detectors, such as sense recognition and finite angular resolution, have a
detrimental effect on the discovery limits, it is still possible to overcome
the ultimate neutrino background faced by non-directional detectors.
[15]
oai:arXiv.org:1409.3270 [pdf] - 969775
First direct limits on Lightly Ionizing Particles with electric charge
less than $e/6$
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nelson, H.;
Nelson, R. H.;
Ogburn, R. W.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-09-10, last modified: 2015-02-03
While the Standard Model of particle physics does not include free particles
with fractional charge, experimental searches have not ruled out their
existence. We report results from the Cryogenic Dark Matter Search (CDMS II)
experiment that give the first direct-detection limits for
cosmogenically-produced relativistic particles with electric charge lower than
$e$/6. A search for tracks in the six stacked detectors of each of two of the
CDMS II towers found no candidates, thereby excluding new parameter space for
particles with electric charges between $e$/6 and $e$/200.
[16]
oai:arXiv.org:1411.5946 [pdf] - 1223294
Comparing readout strategies to directly detect dark matter
Submitted: 2014-11-21, last modified: 2015-01-22
Over the past decades, several ideas and technologies have been developed to
directly detect WIMP from the galactic halo. All these detection strategies
share the common goal of discriminating a WIMP signal from the residual
backgrounds. By directly detecting WIMPs, one can measure some or all of the
observables associated to each nuclear recoil candidates, such as their energy
and direction. In this study, we compare and examine the discovery potentials
of each readout strategies from counting only (bubble chambers) to directional
detectors (Time Projection Chambers) with 1d-, 2d-, and 3d-sensitivity. Using a
profile likelihood analysis, we show that, in the case of a large and
irreducible background contamination characterized by an energy distribution
similar to the expected WIMP signal, directional information can improve the
sensitivity of the experiment by several orders of magnitude. We also found
that 1d directional detection is only less effective than a full 3d directional
sensitivity by about a factor of 3, or 10 if we assume no sense recognition,
still improving by a factor of 2 or more if only the energy of the events is
being measured.
[17]
oai:arXiv.org:1410.1003 [pdf] - 975596
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Graham, M.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nelson, R. H.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-10-03
We report on the results of a search for a Weakly Interacting Massive
Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search
(CDMS~II) experiment using a maximum likelihood analysis. A background model is
constructed using GEANT4 to simulate the surface-event background from
$^{210}$Pb decay-chain events, while using independent calibration data to
model the gamma background. Fitting this background model to the data results
in no statistically significant WIMP component. In addition, we perform fits
using an analytic ad hoc background model proposed by Collar and Fields, who
claimed to find a large excess of signal-like events in our data. We confirm
the strong preference for a signal hypothesis in their analysis under these
assumptions, but excesses are observed in both single- and multiple-scatter
events, which implies the signal is not caused by WIMPs, but rather reflects
the inadequacy of their background model.
[18]
oai:arXiv.org:1409.0050 [pdf] - 1182794
Solar neutrino physics with low-threshold dark matter detectors
Submitted: 2014-08-29
Dark matter detectors will soon be sensitive to Solar neutrinos via two
distinct channels: coherent neutrino-nucleus scattering and neutrino electron
elastic scattering. We establish an analysis method for extracting Solar model
properties and neutrino properties from these measurements, including the
possible effects of sterile neutrinos which have been hinted at by some reactor
experiments and cosmological measurements. Even including sterile neutrinos,
through the coherent scattering channel a 1 ton-year exposure with a
low-threshold Germanium detector could improve on the current measurement of
the normalization of the $^8$B Solar neutrino flux down to 3% or less.
Combining with the elastic scattering data will provide constraints on both the
high and low energy survival probability, and will improve on the uncertainty
on the active-to-sterile mixing angle by a factor of two. This sensitivity to
active-to-sterile transitions is competitive and complementary to forthcoming
dedicated short baseline sterile neutrino searches with nuclear decays.
[19]
oai:arXiv.org:1408.3581 [pdf] - 1216325
Complementarity of dark matter detectors in light of the neutrino
background
Submitted: 2014-08-15
Direct detection dark matter experiments looking for WIMP-nucleus elastic
scattering will soon be sensitive to an irreducible background from neutrinos
which will drastically affect their discovery potential. Here we explore how
the neutrino background will affect future ton-scale experiments considering
both spin-dependent and spin-independent interactions. We show that combining
data from experiments using different targets can improve the dark matter
discovery potential due to target complementarity. We find that in the context
of spin-dependent interactions, combining results from several targets can
greatly enhance the subtraction of the neutrino background for WIMP masses
below 10 GeV/c$^2$ and therefore probe dark matter models to lower
cross-sections. In the context of target complementarity, we also explore how
one can tune the relative exposures of different target materials to optimize
the WIMP discovery potential.
[20]
oai:arXiv.org:1402.7137 [pdf] - 841566
Search for Low-Mass WIMPs with SuperCDMS
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Beaty, J.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cherry, M.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
DeVaney, D.;
Di Stefano, P. C. F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Hansen, S.;
Harris, H. R.;
Hertel, S. A.;
Hines, B. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kenany, S.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Nelson, R. H.;
Novak, L.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Platt, M.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Resch, R. W.;
Ricci, Y.;
Ruschman, M.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schmitt, R. L.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Serfass, B.;
Shank, B.;
Speller, D.;
Tomada, A.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-02-28, last modified: 2014-03-12
We report a first search for weakly interacting massive particles (WIMPs)
using the background rejection capabilities of SuperCDMS. An exposure of 577
kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region
blinded. Eleven events were observed after unblinding. We set an upper limit on
the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2.
This result is in tension with WIMP interpretations of recent experiments and
probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6
GeV/c2.
[21]
oai:arXiv.org:1305.2360 [pdf] - 776422
In situ measurement of the electron drift velocity for upcoming
directional Dark Matter detectors
Billard, J.;
Mayet, F.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Richer, J. P.;
Riffard, Q.;
Santos, D.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2013-05-10, last modified: 2014-01-28
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection and it requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence needed as it is a way to avoid bias in the 3D track reconstruction. We
present a dedicated method for the measurement of the electron drift velocity
with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3.
The latter has been chosen for the MIMAC detector as we expect that adding CHF3
to pure CF4 will lower the electron drift velocity. This is a key point for
directional Dark Matter as the track sampling along the drift field will be
improved while keeping almost the same Fluorine content of the gas mixture. We
show that the drift velocity at 50 mbar is reduced by a factor of about 5 when
adding 30% of CHF3.
[22]
oai:arXiv.org:1307.5458 [pdf] - 1172869
Implication of neutrino backgrounds on the reach of next generation dark
matter direct detection experiments
Submitted: 2013-07-20, last modified: 2014-01-19
As direct dark matter experiments continue to increase in size, they will
become sensitive to neutrinos from astrophysical sources. For experiments that
do not have directional sensitivity, coherent neutrino scattering (CNS) from
several sources represents an important background to understand, as it can
almost perfectly mimic an authentic WIMP signal. Here we explore in detail the
effect of neutrino backgrounds on the discovery potential of WIMPs over the
entire mass range of 500 MeV to 10 TeV. We show that, given the theoretical and
measured uncertainties on the neutrino backgrounds, direct detection
experiments lose sensitivity to light (~10 GeV) and heavy (~100 GeV) WIMPs with
a spin-independent cross section below 10^{-45} cm^2 and 10^{-49} cm^2,
respectively.
[23]
oai:arXiv.org:1401.1009 [pdf] - 766735
Measurement of the electron drift velocity for directional dark matter
detectors
Mayet, F.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Richer, J. P.;
Riffard, Q.;
Santos, D.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2014-01-06
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection. It requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence a way to avoid bias in the 3D track reconstruction. We present a
dedicated method for the measurement of the electron drift velocity with the
MIMAC detector. It is tested on two gas mixtures : $\rm CF_4$ and $\rm
CF_4+CHF_3$. We also show that adding $\rm CHF_3$ allows us to lower the
electron drift velocity while keeping almost the same Fluorine content of the
gas mixture.
[24]
oai:arXiv.org:1312.7737 [pdf] - 1934991
Profile likelihood ratio analysis techniques for rare event signals
Submitted: 2013-12-30
The Cryogenic Dark Matter Search (CDMS) II uses crystals operated at
milliKelvin temperature to search for dark matter. We present the details of
the profile likelihood analysis of 140.2 kg-day exposure from the final data
set of the CDMS II Si detectors that revealed three WIMP-candidate events. We
found that this result favors a WIMP+background hypothesis over the
known-background-only hypothesis at the 99.81% confidence level. This paper is
dedicated to the description of the profile likelihood analysis dedicated to
the CDMSII-Si data and discusses such analysis techniques in the scope of rare
event searches.
[25]
oai:arXiv.org:1309.3259 [pdf] - 779590
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted
Calorimetric Ionization Detection in the SuperCDMS Experiment
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-09-12, last modified: 2013-12-20
SuperCDMS is an experiment designed to directly detect Weakly Interacting
Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in
the Universe. In this paper, we present WIMP-search results using a
calorimetric technique we call CDMSlite, which relies on voltage- assisted
Luke-Neganov amplification of the ionization energy deposited by particle
interactions. The data were collected with a single 0.6 kg germanium detector
running for 10 live days at the Soudan Underground Laboratory. A low energy
threshold of 170 eVee (electron equivalent) was obtained, which allows us to
constrain new WIMP-nucleon spin-independent parameter space for WIMP masses
below 6 GeV/c2.
[26]
oai:arXiv.org:1304.4279 [pdf] - 732067
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-04-15, last modified: 2013-10-11
We report results of a search for Weakly Interacting Massive Particles
(WIMPS) with the silicon detectors of the CDMS II experiment. This blind
analysis of 140.2 kg-days of data taken between July 2007 and September 2008
revealed three WIMP-candidate events with a surface-event background estimate
of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds
from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90%
confidence level, respectively. The exposure of this analysis is equivalent to
23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10
GeV/c2. The probability that the known backgrounds would produce three or more
events in the signal region is 5.4%. A profile likelihood ratio test of the
three events that includes the measured recoil energies gives a 0.19%
probability for the known-background-only hypothesis when tested against the
alternative WIMP+background hypothesis. The highest likelihood occurs for a
WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
[27]
oai:arXiv.org:1310.0214 [pdf] - 764776
A review on the discovery reach of Dark Matter directional detection
Submitted: 2013-10-01
Directional detection of galactic Dark Matter offers a unique opportunity to
identify Weakly Interacting Massive Particle (WIMP) events as such. Depending
on the unknown WIMP-nucleon cross section, directional detection may be used to
: exclude Dark Matter, discover galactic Dark Matter with a high significance
or constrain WIMP and halo properties. We review the discovery reach of Dark
Matter directional detection.
[28]
oai:arXiv.org:1306.4173 [pdf] - 681293
Dark Matter directional detection with MIMAC
Riffard, Q.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Mayet, F.;
Muraz, J. -F.;
Richer, J. -P.;
Santos, D.;
Lebreton, L.;
Maire, D.;
Busto, J.;
Brunner, J.;
Fouchez, D.
Submitted: 2013-06-18
Directional detection is a promising direct Dark Matter (DM) search strategy.
The angular distribution of the nuclear recoil tracks from WIMP events should
present an anisotropy in galactic coordinates. This strategy requires both a
measurement of the recoil energy with a threshold of about 5 keV and 3D recoil
tracks down to few millimeters.
The MIMAC project, based on a \textmu-TPC matrix, with $CF_4$ and $CHF_3$, is
being developed. In June 2012, a bi-chamber prototype was installed at the LSM
(Laboratoire Souterrain de Modane). A preliminary analysis of the first four
months data taking allowed, for the first time, the observation of recoils from
the $\mathrm{^{222}Rn}$ progeny.
[29]
oai:arXiv.org:1304.2255 [pdf] - 1165808
MIMAC: A micro-tpc matrix for dark matter directional detection
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, C.;
Guillaudin, O.;
Lamblin, J.;
Muraz, J. F.;
Mayet, F.;
Richer, J. P.;
Riffard, Q.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2013-04-08
The dark matter directional detection opens a new field in cosmology bringing
the possibility to build a map of nuclear recoils that would be able to explore
the galactic dark matter halo giving access to a particle characterization of
such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers)
collaboration has developed in the last years an original prototype detector
based on the direct coupling of large pixelized micromegas with a devoted fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The discovery potential of this search strategy is
discussed and illustrated. In June 2012, the first bi-chamber prototype has
been installed at Modane Underground Laboratory (LSM) and the first underground
background events, the gain stability and calibration are shown.
[30]
oai:arXiv.org:1207.1050 [pdf] - 1124595
Is a co-rotating Dark Disk a threat to Dark Matter Directional Detection
?
Submitted: 2012-07-04, last modified: 2013-01-12
Recent N-Body simulations are in favor of the presence of a co-rotating Dark
Disk that might contribute significantly (10%-50%) to the local Dark Matter
density. Such substructure could have dramatic effect on directional detection.
Indeed, in the case of a null lag velocity, one expects an isotropic WIMP
velocity distribution arising from the Dark Disk contribution, which might
weaken the strong angular signature expected in directional detection. For a
wide range of Dark Disk parameters, we evaluate in this Letter the effect of
such dark component on the discovery potential of upcoming directional
detectors. As a conclusion of our study, using only the angular distribution of
nuclear recoils, we show that Dark Disk models as suggested by recent N-Body
simulations will not affect significantly the Dark Matter reach of directional
detection, even in extreme configurations.
[31]
oai:arXiv.org:1205.0973 [pdf] - 1123165
Low energy electron/recoil discrimination for directional Dark Matter
detection
Submitted: 2012-05-04, last modified: 2012-07-11
Directional detection is a promising Dark Matter search strategy. Even though
it could accommodate to a sizeable background contamination, electron/recoil
discrimination remains a key and challenging issue as for direction-insensitive
detectors. The measurement of the 3D track may be used to discriminate
electrons from nuclear recoils. While a high rejection power is expected above
20 keV ionization, a dedicated data analysis is needed at low energy. After
identifying discriminant observables, a multivariate analysis, namely a Boosted
Decision Tree, is proposed, enabling an efficient event tagging for Dark Matter
search. We show that it allows us to optimize rejection while keeping a rather
high efficiency which is compulsory for rare event search.With respect to a
sequential analysis, the rejection is about 20 times higher with a multivariate
analysis, for the same Dark Matter exclusion limit.
[32]
oai:arXiv.org:1207.1053 [pdf] - 1513462
Directional detection of galactic dark matter
Submitted: 2012-07-04
Directional detection is a promising Dark Matter search strategy. Taking
advantage on the rotation of the Solar system around the galactic center
through the Dark Matter halo, it allows to show a direction dependence of WIMP
events that may be a powerful tool to identify genuine WIMP events as such.
Directional detection strategy requires the simultaneous measurement of the
energy and the 3D track of low energy recoils, which is a common challenge for
all current projects of directional detectors.
[33]
oai:arXiv.org:1202.3372 [pdf] - 498921
Three-dimensional track reconstruction for directional Dark Matter
detection
Submitted: 2012-02-15, last modified: 2012-04-11
Directional detection of Dark Matter is a promising search strategy. However,
to perform such detection, a given set of parameters has to be retrieved from
the recoiling tracks : direction, sense and position in the detector volume. In
order to optimize the track reconstruction and to fully exploit the data of
forthcoming directional detectors, we present a likelihood method dedicated to
3D track reconstruction. This new analysis method is applied to the MIMAC
detector. It requires a full simulation of track measurements in order to
compare real tracks to simulated ones. We conclude that a good spatial
resolution can be achieved, i.e. sub-mm in the anode plane and cm along the
drift axis. This opens the possibility to perform a fiducialization of
directional detectors. The angular resolution is shown to range between
20$^\circ$ to 80$^\circ$, depending on the recoil energy, which is however
enough to achieve a high significance discovery of Dark Matter. On the
contrary, we show that sense recognition capability of directional detectors
depends strongly on the recoil energy and the drift distance, with small
efficiency values (50%-70%). We suggest not to consider this information either
for exclusion or discovery of Dark Matter for recoils below 100 keV and then to
focus on axial directional data.
[34]
oai:arXiv.org:1110.6079 [pdf] - 498884
Assessing the discovery potential of directional detection of Dark
Matter
Submitted: 2011-10-27, last modified: 2012-02-03
There is a worldwide effort toward the development of a large TPC (Time
Projection Chamber) devoted to directional Dark Matter detection. All current
projects are being designed to fulfill a unique goal : identifying weakly
interacting massive particle (WIMP) as such by taking advantage of the expected
direction dependence of WIMP-induced events toward the constellation Cygnus.
However such proof of discovery requires a careful statistical data treatment.
In this paper, the discovery potential of forthcoming directional detectors is
adressed by using a frequentist approach based on the profile likelihood ratio
test statistic. This allows us to estimate the expected significance of a Dark
Matter detection. Moreover, using this powerful test statistic, it is possible
to propagate astrophysical and experimental uncertainties in the determination
of the discovery potential of a given directional detection experiment. This
way, we found that a 30 kg.year CF$_4$ directional experiment could reach a
3$\sigma$ sensitivity at 90% C.L. down to $10^{-5}$ pb and $3.10^{-4}$ pb for
the WIMP-proton axial cross section in the most optimistic and pessimistic
scenario respectively.
[35]
oai:arXiv.org:1201.6150 [pdf] - 498917
Probing neutralino dark matter in the MSSM & the NMSSM with directional
detection
Submitted: 2012-01-30
We investigate the capability of directional detectors to probe neutralino
dark matter in the Minimal Supersymmetric Standard Model and the
Next-to-Minimal Supersymmetric Standard Model with parameters defined at the
weak scale. We show that directional detectors such as the future MIMAC
detector will probe spin dependent dark matter scattering on nucleons that are
beyond the reach of current spin independent detectors. The complementarity
between indirect searches, in particular using gamma rays from dwarf spheroidal
galaxies, spin dependent and spin independent direct search techniques is
emphasized. We comment on the impact of the negative results on squark searches
at the LHC. Finally, we investigate how the fundamental parameters of the
models can be constrained in the event of a dark matter signal.
[36]
oai:arXiv.org:1111.1566 [pdf] - 435178
MIMAC: A micro-tpc matrix project for directional detection of dark
matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-11-07
Directional detection of non-baryonic DarkMatter is a promising search
strategy for discriminating WIMP events from background ones. This strategy
requires both a measurement of the recoil energy down to a few keV and 3D
reconstruction of tracks down to a few mm. The MIMAC project, based on a
micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first
results of a chamber prototype of this matrix, on low energy nuclear recoils
(1H and 19F) obtained with mono-energetic neutron fields are presented. The
discovery potential of this search strategy is illustrated by a realistic case
accessible to MIMAC.
[37]
oai:arXiv.org:1110.4348 [pdf] - 437252
Data acquisition electronics and reconstruction software for real time
3D track reconstruction within the MIMAC project
Submitted: 2011-10-19, last modified: 2011-11-02
Directional detection of non-baryonic Dark Matter requires 3D reconstruction
of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with
either 3He, CF4 or C4H10 has been developed within the MIMAC project. A
dedicated acquisition electronics and a real time track reconstruction software
have been developed to monitor a 512 channel prototype. This autotriggered
electronic uses embedded processing to reduce the data transfer to its useful
part only, i.e. decoded coordinates of hit tracks and corresponding energy
measurements. An acquisition software with on-line monitoring and 3D track
reconstruction is also presented.
[38]
oai:arXiv.org:1110.5999 [pdf] - 1085189
Directional Detection of Dark Matter with MIMAC
Submitted: 2011-10-27
Directional detection is a promising search strategy to discover galactic
Dark Matter. We present a Bayesian analysis framework dedicated to Dark Matter
phenomenology using directional detection. The interest of directional
detection as a powerful tool to set exclusion limits, to authentify a Dark
Matter detection or to constrain the Dark Matter properties, both from particle
physics and galactic halo physics, will be demonstrated. However, such results
need highly accurate track reconstruction which should be reachable by the
MIMAC detector using a dedicated readout combined with a likelihood analysis of
recoiling nuclei.
[39]
oai:arXiv.org:1110.0955 [pdf] - 1084648
Track reconstruction with MIMAC
Submitted: 2011-10-05
Directional detection of Dark Matter is a promising search strategy. However,
to perform such kind of detection, the recoiling tracks have to be accurately
reconstructed: direction, sense and position in the detector volume. In order
to optimize the track reconstruction and to fully exploit the data from the
MIMAC detector, we developed a likelihood method dedicated to the track
reconstruction. This likelihood approach requires a full simulation of track
measurements with MIMAC in order to compare real tracks to simulated ones.
Finally, we found that the MIMAC detector should have the required performance
to perform a competitive directional detection of Dark Matter.
[40]
oai:arXiv.org:1110.0951 [pdf] - 1084646
Exclusion, Discovery and Identification of Dark Matter with Directional
Detection
Submitted: 2011-10-05
Directional detection is a promising search strategy to discover galactic
Dark Matter. We present a Bayesian analysis framework dedicated to data from
upcoming directional detectors. The interest of directional detection as a
powerful tool to set exclusion limits, to authentify a Dark Matter detection or
to constrain the Dark Matter properties, both from particle physics and
galactic halo physics, will be demonstrated.
[41]
oai:arXiv.org:1110.1056 [pdf] - 483350
Directional detection of Dark Matter
Submitted: 2011-10-05
Directional detection is a promising Dark Matter search strategy. Taking
advantage on the rotation of the Solar system around the galactic center
through the Dark Matter halo, it allows to show a direction dependence of WIMP
events. It requires the simultaneous measurement of the energy and the 3D track
of low energy recoils, which is a common challenge for all current projects of
directional detectors. The third CYGNUS workshop on directional dark matter
detection has brought together the scientific community working on both
theoretical and experimental aspects of the subject. In this paper, we give an
introductory revue of directional detection of Dark Matter, focusing on the
main recent progresses.
[42]
oai:arXiv.org:1109.2002 [pdf] - 478078
Dedicated front-end and readout electronics developments for real time
3D directional detection of dark matter with MIMAC
Submitted: 2011-09-09, last modified: 2011-09-19
A complete dedicated electronics, from front-end to back-end, was developed
to instrument a MIMAC prototype. A front end ASIC able to monitor 64 strips of
pixels and to provide their individual "Time Over Threshold" information has
been designed. An associated acquisition electronics and a real time track
reconstruction software have been developed to monitor a 512 channel prototype.
This auto-triggered electronic uses embedded processing to reduce the data
transfer to its useful part only, i.e. decoded coordinates of hit tracks and
corresponding energy measurements. The electronic designs, acquisition software
and the results obtained are presented.
[43]
oai:arXiv.org:1109.1675 [pdf] - 1083919
Micromegas detector developments for MIMAC
Ferrer-Ribas, E.;
Attié, D.;
Calvet, D.;
Colas, P.;
Druillole, F.;
Giomataris, Y.;
Iguaz, F. J.;
Mols, J. P.;
Pancin, J.;
Papaevangelou, T.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-09-08, last modified: 2011-09-12
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a
directional TPC. The recent Micromegas efforts towards building a large size
detector will be described, in particular the characterization measurements of
a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout
plane. Track reconstruction with alpha particles will be shown.
[44]
oai:arXiv.org:1012.3960 [pdf] - 347830
Markov Chain Monte Carlo analysis to constrain Dark Matter properties
with directional detection
Submitted: 2010-12-17, last modified: 2011-04-01
Directional detection is a promising dark matter search strategy. Indeed,
weakly interacting massive particle (WIMP)-induced recoils would present a
direction dependence toward the Cygnus constellation, while background-induced
recoils exhibit an isotropic distribution in the Galactic rest frame. Taking
advantage of these characteristic features and even in the presence of a
sizeable background, it has recently been shown that data from forthcoming
directional detectors could lead either to a competitive exclusion or to a
conclusive discovery, depending on the value of the WIMP-nucleon cross section.
However, it is possible to further exploit these upcoming data by using the
strong dependence of the WIMP signal with : the WIMP mass and the local WIMP
velocity distribution. Using a Markov chain Monte Carlo analysis of recoil
events, we show for the first time the possibility to constrain the unknown
WIMP parameters, both from particle physics (mass and cross section) and
Galactic halo (velocity dispersion along the three axis), leading to an
identification of non-baryonic dark matter.
[45]
oai:arXiv.org:1102.3265 [pdf] - 399526
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-02-16
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with CF4 and CHF3. The first results on low energy nuclear recoils (H, F)
obtained with a low mono-energetic neutron field are presented. The discovery
potential of this search strategy is discussed and illustrated by a realistic
case accessible to MIMAC.
[46]
oai:arXiv.org:1101.2750 [pdf] - 1051418
Directional detection of Dark Matter with MIMAC: WIMP identification and
track reconstruction
Submitted: 2011-01-14
Directional detection is a promising Dark Matter search strategy. Indeed,
WIMP-induced recoils present a direction dependence toward the Cygnus
constellation, while background-induced recoils exhibit an isotropic
distribution in the galactic rest frame. Taking advantage on these
characteristic features and even in the presence of a sizeable background, we
show for the first time the possibility to constrain the WIMP properties, both
from particle and galactic halo physics, leading to an identification of
non-baryonic Dark Matter. However, such results need highly accurate track
reconstruction which should be reachable by the MIMAC detector using a
dedicated readout combined with a likelihood analysis of recoiling nuclei.
[47]
oai:arXiv.org:1012.1166 [pdf] - 955699
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Allaoua, A.;
Golabek, C.;
Lebreton, L.
Submitted: 2010-12-06
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H
and 19F) obtained with a low mono-energetic neutron field are presented. The
discovery potential of this search strategy is discussed and illustrated by a
realistic case accessible to MIMAC.
[48]
oai:arXiv.org:1009.5568 [pdf] - 232779
Identification of Dark Matter with directional detection
Submitted: 2010-09-28
Directional detection is a promising search strategy to discover galactic
Dark Matter. Taking advantage on the rotation of the Solar system around the
Galactic center through the Dark Matter halo, it allows to show a direction
dependence of WIMP events. Data of directional detectors are composed of energy
and a 3D track for each recoiling nuclei. Here, we present a Bayesian analysis
method dedicated to data from upcoming directional detectors. However, we focus
only on the angular part of the event distribution, arguing that the energy
part of the background distribution is unknown. Two different cases are
considered: a positive or a null detection of Dark Matter. In the first
scenario, we will present a map-based likelihood method allowing to recover the
main incoming direction of the signal and its significance, thus proving its
Galactic origin. In the second scenario, a new statistical method is proposed.
It is based on an extended likelihood in order to set robust and competitive
exclusion limits. This method has been compared to two other methods and has
been shown to be optimal in any detector configurations. Eventually, prospects
for the MIMAC project are presented in the case of a 10 kg CF4 detector with an
exposition time of 3 years.
[49]
oai:arXiv.org:1008.4712 [pdf] - 228441
Directional detection of non-baryonic dark matter with MIMAC
Grignon, C.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Ferrer, E.;
Giomataris, I.;
Mols, J. P.
Submitted: 2010-08-27, last modified: 2010-09-17
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating genuine WIMP events from background ones. However,
carrying out such a strategy requires both a precise measurement of the energy
down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve
this goal, the MIMAC project has been developed: it is based on a gaseous
micro-TPC matrix, filled with 3He, CF4 and/or C4H10. Firsts results of low
energy nuclei recoils obtained with a low energy neutron field are presented.
[50]
oai:arXiv.org:1006.3513 [pdf] - 227157
Exclusion limits from data of directional Dark Matter detectors
Submitted: 2010-06-17, last modified: 2010-09-06
Directional detection is a promising search strategy to discover galactic
Dark Matter. Taking advantage on the rotation of the Solar system around the
Galactic center through the Dark Matter halo, it allows to show a direction
dependence of WIMP events. Even though the goal of directional search is to
identify a WIMP positive detection, exclusion limits are still needed for very
low exposure with a rather large background contamination, such as the one
obtained with prototype experiments. Data of directional detectors are composed
of energy and 3D track of recoiling nuclei. However, to set robust exclusion
limits, we focus on the angular part of the event distribution, arguing that
the energy part of the WIMP distribution is featureless and may even be mimic
by the background one. Then, as the angular distributions of both background
and WIMP events are known, a Bayesian approach to set exclusion limits is
possible. In this paper, a statistical method based on an extended likelihood
is proposed, compared to existing ones and is shown to be optimal. Eventually,
a comprehensive study of the effect of detector configuration on exclusion
limits is presented. It includes the effect of having or not sense recognition,
a finite angular resolution, taking into account energy threshold as well as
some astrophysical uncertainties.
[51]
oai:arXiv.org:0911.4086 [pdf] - 902498
Directional detection as a strategy to discover Galactic Dark Matter
Submitted: 2009-11-20, last modified: 2010-06-28
Directional detection of Galactic Dark Matter is a promising search strategy
for discriminating genuine WIMP events from background ones. Technical progress
on gaseous detectors and read-outs has permitted the design and construction of
competitive experiments. However, to take full advantage of this powerful
detection method, one need to be able to extract information from an observed
recoil map to identify a WIMP signal. We present a comprehensive formalism,
using a map-based likelihood method allowing to recover the main incoming
direction of the signal and its significance, thus proving its galactic origin.
This is a blind analysis intended to be used on any directional data.
Constraints are deduced in the ($\sigma_n, m_\chi$) plane and systematic
studies are presented in order to show that, using this analysis tool,
unambiguous dark matter detection can be achieved on a large range of exposures
and background levels.
[52]
oai:arXiv.org:1004.2365 [pdf] - 148607
Directional detection of Dark Matter
Submitted: 2010-04-14
Directional detection of galactic Dark Matter is a promising search strategy
for discriminating genuine WIMP events from background ones. However, to take
full advantage of this powerful detection method, one need to be able to
extract information from an observed recoil map to identify a WIMP signal. We
present a comprehensive formalism, using a map-based likelihood method allowing
to recover the main incoming direction of the signal, thus proving its galactic
origin, and the corresponding significance. Constraints are then deduced in the
(sigma_n, m_chi) plane.
[53]
oai:arXiv.org:1001.2983 [pdf] - 32880
Directional detection of galactic Dark Matter
Mayet, F.;
Billard, J.;
Bernard, G.;
Bosson, G.;
Bourrion, O.;
Grignon, C.;
Guillaudin, O.;
Koumeir, C.;
Richer, J. P.;
Santos, D.;
Colas, P.;
Ferer, E.;
Giomataris, I.;
Allaoua, A.;
Lebreton, L.
Submitted: 2010-01-18
Directional detection of galactic Dark Matter is a promising search strategy
for discriminating geniune WIMP events from background ones. We present
technical progress on gaseous detectors as well as recent phenomenological
studies, allowing the design and construction of competitive experiments.
[54]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[55]
oai:arXiv.org:0909.0654 [pdf] - 901600
A prototype of a directional detector for non-baryonic dark matter
search: MIMAC (Micro-TPC Matrix of Chambers)
Grignon, C.;
Bernard, G.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Koumeir, C.;
Mayet, F.;
Santos, D.;
Colas, P.;
Ferrer, E.;
Giomataris, I.;
Allaoua, A.;
Lebreton, L.
Submitted: 2009-09-03, last modified: 2009-10-30
We have developed a micro-tpc using a pixelized bulk micromegas coupled to
dedicated acquisition electronics as a read-out allowing to reconstruct the
three dimensional track of a few keV recoils. The prototype has been tested
with the Amande facility at the IRSN-Cadarache providing monochromatic
neutrons. The first results concerning discrimination of a few keV electrons
and proton recoils are presented.
[56]
oai:arXiv.org:0905.4800 [pdf] - 24752
Dark matter directional detection with MIMAC
Grignon, C.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Koumeir, C.;
Mayet, F.;
Santos, D.;
Colas, P.;
Ferrer, E.;
Giomataris, I.
Submitted: 2009-05-29
MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for
direct detection of non-baryonic dark matter. Measurement of both track and
ionization energy will allow the electron-recoil discrimination, while access
to the directionnality of the tracks will open a unique way to distinguish a
geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV
electrons are presented as a proof of concept.